Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC | L1 | Accepted-AOC Due to lowest accepted | |
| 2 | L2₹6.3 L+₹22,603.98 (3.70%)Rejected-Finance 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹6.9 L+₹82,956.01 (13.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹8.2 L+₹2.1 L (34.9%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
26 Aug 2022, 6:00 pmClosed
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge CG Complex Ludhiana-141001
REPAIR/REPLACEMENT TO STREET LIGHTS/SECURITY LIGHTS AND CONNECTED E/M ITEMS AT CG COMPLEX DORAHA AND PHILLOUR UNDER GE LUDHIANA
2022_MES_542239_1
GE/LDH-31/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CG Complex Doraha Phillaur Under GE Ludhiana
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹20,000
Yes
13 Sept 2022
30 Jul 2022
27 Aug 2022
30 Jul 2022
26 Aug 2022
13 Aug 2022
30 Jul 2022 - 12 Aug 2022
Amount
Taking down existing street light fittings of any type/size/capacity fixed in any position i.e. on wall/ pole/ watch tower fixing the fitting in its original position after repairs complete all as specified and directed by Engineer- in-Charge . (Note:-Spares shall be measured and paid separately)
S & F in replacement LED street light luminaire of 45 watt in epoxy powder coated pressure die-cast aluminium housing of standard size, BIS marked electronic driver of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficacy 100 lumens/watt all as specified and directed by Engineer- in-Charge.Brand name should be embossed on fixture to ensure Indian brand only.
S & F in replacement LED street light luminaire of 60 watt in epoxy powder coated pressure die-cast aluminium housing of standard size, BIS marked electronic driver of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficacy 100 lumens/watt all as specified and directed by Engineer- in-Charge.Brand name should be embossed on fixture to ensure Indian brand only.
S & F in replacement LED street light luminaire of 90 watt in epoxy powder coated pressure die-cast aluminium housing of standard size, BIS marked electronic driver of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficacy 100 lumens/watt all as specified and directed by Engineer- in-Charge.Brand name should be embossed on fixture to ensure Indian brand only.
S & F for LED flood light fitting of 120 watt in epoxy powder coated pressure die-cast aluminium housing with, BIS marked electronic driver duly enclosed of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening of 5 KV minimum with IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficacy 100 lumens/watt all as specified and directed by Engineer- in-Charge.
S & F for LED flood light fitting of 150 watt in epoxy powder coated pressure die-cast aluminium housing with, BIS marked electronic driver duly enclosed of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening of 5 KV minimum with IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficacy 100 lumens/watt all as specified and directed by Engineer- in-Charge. .
S & F for LED flood light fitting of 200 watt in epoxy powder coated pressure die-cast aluminium housing with, BIS marked electronic driver duly enclosed of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening of 5 KV minimum with IP-66, protection for LED and control gear compartments with high power LED chips suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficacy 100 lumens/watt all as specified and directed by Engineer- in-Charge. .
Supply & fixing for LED post top lantern 40 W e-top with aluminium die cast housing cum heat sink with PMHA diffuser in IP 65 including taking down existing light fittings etc complete all as specified and directed by Engineer-in-Charge. Note for Srl No. 2 to 8 :- (i) All LED fittings shall have supporting LM-79 & LM-80 test certificate from govt approved NABL accredited Lab showing all the parameters duly signed by the local office bearer of manufacturer. (ii) All LED fittings shall have 2 years written Warranty from local office bearer of manufacturer.
Supply and fixing for 1100 volt grade heavy duty single core cable PVC insulated PVC sheathed with stranded copper conductor wire FRLS of size 2 x 1.5 Sqmm and 1 x 1.5 sqmm for connection purpose, ISI marked drawing through 20mm dia PVC pipe / conduit complete all as specified and directed by the Engr-in-Charge.Note:- Three run cable shall be measured in one unit.
Taking up/down worn out/damaged/unserviceable PVC insulated underground cable armoured, heavy duty with aluminium conductors of any size, 1100V grade from trench/duct/pole/wall/pipes/rooftops etc. complete all as specified and directed by Engr-in-Charge. Note:- Excavation and earth work shall be measured and paid separetely.
Supply and laying for XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded alumimium conductor of size 10 Sqmm 2 core etc complete all as specified and directed by Engr-in-Charge.
Supply and laying for XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded alumimium conductor of size 10 Sqmm 4 core complete all as specified and directed by Engr-in-Charge.
Supply and laying for XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded alumimium conductor of size 16 Sqmm 4 core complete all as specified and directed by Engr-in-Charge.
Supply and laying for XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded alumimium conductor of size 25 Sqmm 4 core complete all as specified and directed by Engr-in-Charge.
Supply and laying for XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded alumimium conductor of size 35 Sqmm 4 core complete all as specified and directed by Engr-in-Charge.
Excavating in trenches in soft/ loose soil not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundation for pipes, walls, cesspits, manholes, pier holes, cables etc not exceeding 10 Sqm on plan and not exceeding 1.50 m in depth and getting out complete all as specified and directed by Engr-in-Charge.
Returning, filling in, spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified and directed by Engr-in-Charge.
Removal of excavated spoil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified and directed by Engr-in-Charge.. Notes: (i) Excavation and earth work to be measured and paid for separately (ii) Thickness of 18 cms after punning shall be considered for payment.
Material and labour for old size sub class ‘B’ bricks laid flat in trenches over the cable with length of brick perpendicular to the direction of cable, adjacent/ abutting each other, complete all as specified and directed by Engr-in-Charge.. Note: Excavation and earth work to be measured and paid for separately.
Supply and fixing in replacement of driver suitable for any type of street light 20W/45 watt complete all as specified and directed by Engineer- in-Charge.
Supply and fixing in replacement of driver suitable for any type of street light 60watt/90 W,120W,150/200 W complete all as specified and directed by Engineer- in-Charge.
Supply and fixing in replacement of Surge protection device suitable for any type of street light 20watt/45W complete all as specified and directed by Engineer- in-Charge.
Supply and fixing in replacement of Surge protection device suitable for any type of street light 60watt/90W,120/150/200 W, complete all as specified and directed by Engineer- in-Charge.
S&F in replacement of Polycarbonate ASTA CPRI approved OEM made street light junction box .The junction box IP 66 weather proof & enclousers for outdoor installation with knockouts for cable entry of size 10-16 sqmm etc complete all as specified and directed by Engineer- in-Charge.
S&F in replacement of Polycarbonate ASTA CPRI approved OEM made street light junction box .The junction box IP 66 weather proof & enclousers for outdoor installation with knockouts for cable entry of size 10-25 sqmm etc complete all as specified and directed by Engineer- in-Charge.
M & L for inreplacement MCCB 63 Amps, 4 pole, with adjustable thermal adjustable magnetic release, ICS=ICU=100%, 415 volts, 50 HZ, 25 KA complete all as specified & directed by Engineer-in- charge.
M & L for inreplacement MCCB 100 Amps, 4 pole, with adjustable thermal adjustable magnetic release, ICS=ICU=100%, 415 volts, 50 HZ, 25 KA complete all as specified & directed by Engineer-in- charge.
M & L for inreplacement TPN MCB,4 pole 415 Volts, 50 Hz, having rupturing capacity 10 KA, of rating 40 to 100 Amps complete all as specified & directed by Engineer-in- charge.
M & L for inreplacement MCB SPN , 240 Volts, 50 Hz, having rupturing capacity 10 KA, of rating 32 Amps complete all as specified & directed by Engineer-in- charge.
M&L for MCB SP 6 TO 32 Amps, 10 KA, C-curve complete all as specified & directed by Engineer-in- charge.
Material & Labour for demolition of cement concrete of any description and in any position complete all as specified and directed by Engr-in-Charge.
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of electric poles, struts, PCC block including necessary form work and fair finish to exposed surfaces without using extra cement etc. complete all as specified and directed by Engineer- in-Charge.
M & L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in foundation filling upto ground level etc. complete all as specified and directed by Engineer- in-Charge.
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping of poles etc. with slightly rounded or chamfered angles including necessary form work and fair finishing the exposed surface without using extra cement complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for automatic Street Light Switch using Nature switch for automatic switching of street lights based on LUX level of Natural light. The Infrared Sensor based Nature Switch along of capacity of 5 KW, three phase, with suitable Power Contactor(AC 3) 20-32 Amps and MCBs SP (Input-Output) 32 Amps on each phase at incoming and out going connections fully enclosed in pole/wall mountable enclosure, weather and vermin proof having front hinged shutter, rust proof, termite proof and FR grade SMC junction box having to IP 54 protection, pre-wired complete with suitable wire PVC insulated FRLS type copper conductor with suitable copper thimbles/lugs etc complete all as specified and directed by Engr-in-Charge. Make of Nature Switch : Kakatiya Energy Systems Pvt Ltd Hyderabad/ Bajaj/Healer. Make of Contactor : BCH/L&T/Schneider. Make of MCB : Hager/Schneider/L&T/BCH. Make of copper wire : Finolex/Polycab/RR Kable. Make of junction box : Hensel/Schneider/Rittal
M & L for supply,erecting and fixing in position 8.5 metre long steel tubular swaged pole type 410 SP-22 complete with cast iron base plate, final taper plug, bolts, nuts & screws conforming to IS-2713 (Part- I & III) of 1980 and painting the pole with two coats of aluminum paint over a coat of primer including black and white strips 30cm each upto 1.5 metre from top of PCC foundation block and numbering of poles in 80mm high white letter using synthetic enamel paint over base etc including taking down old existing pole all as specified & directed by Engineer-in- charge.
M & L for supply,erecting and fixing in position pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1978 including disconnecting and reconnecting ACSR conductor, painting of poles with two coats of synthetic enamel paint over a coat of primer with black and white strips 30cm each up to 1.5 metre height from top of PCC foundation block and numbering of poles with synthetic enamel paint white in 80mm high letters over 150mm x 230mm yellow base etc including taking down old existing pole complete all as specified and directed by Engr - in - Charge. (PCC for foundation and earth work shall be measured and paid for separately).
M&L for painting of cement concrete poles with junction box,clump and bracket any type of size externally above foundation with two coats of synthetic enamel paint over a coat of primer after scraping/cleaning well the existing surface with black and white strips 30cm each up to 1.5 metre height from top of PCC foundation block and numbering of poles with synthetic enamel paint white in 80mm high letters over 150mm x 230mm yellow base complete all as specified and directed by Engr - in - Charge.
M&L for painting of LT Steel tubular pole with junction box,clump and bracket any type of size externally above foundation with two coat of almn paint over a coat of red oxide primer after scraping/cleaning well the existing surface incl painting of bottom with black white or yellow color strip 30cm each upto 1.5 mtr high from top of PCC foundation block and numbring of pole with synthetic enamel paint white in 80mm high letter over 150mmx230mm yellow base complete all as specified and directed by Engr - in - Charge.
Supply and fixing for galvanised pipe light grade of ISI marked 50 mm bore for passing of cable fixed to poles/walls/lay under floor complete with and including fittings as required compete all as specified and directed by Engr-in-charge.
M&L for trimming / cutting/prooning of the tree branches / bushes which falls within a clear distance of 3 meter from all sides from the HT / LT over head conductor & within line of conductors, and shifting waste to nearby waste depot & cleaning area etc complete all as specified and directed by Engr-in-Charge. Note :- Horizontal distance of tree touching to the over head lines shall be measured for the purpose of payment
Supply and fixing in replacement of PVC spacer/separators on LT OH line conductor for 4 wire including necessary nuts, bolts and fixing properly on ACSR conductor complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement,bracket made out of 40 mm dia galvanized steel tubing medium grade 1.5 m long including bending if required as direct ,02 nos clamps made out of MS flat iron 40X6mm of suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts complete all as specified and directed by Engr-in-Charge.(Rates quoted by the contractor shall deemed to include for nut and bolts).
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:3:6) type C-1 and CI cover with frame, 150 mm,filling of black cotton soil in earth pit up to ground level PCC chamber recessed for including RCC cover including all necessary Exacavation &earth work ,earth wire connected to O/H continous earth wire on pole ,testing the earthing after completion all as shown in MES Schedule (Part-I) including dismantling existing earthing complete all as specified and directed by Engr-in-Charge. Notes :- (i) Outer edge of earth pit will be 1.50 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slantling position (iv) Earth wire and protection pipe upto 7.50m length is icluded in the unit rate
Supply only insulation LT tape size normal width 20mm Length 25 Mtr Thickness 0.125mm
SUN MANN ENGINEERS
TESLA ENGINEERS & BUILDERS
GLOBAL ENGINEERS AND INNOVATORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .