Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-Finance | ₹11.8 L | L1 | Accepted-Finance approved |
| 2 | L2₹13.8 LAccepted-Finance | ₹13.8 L | L2 | Accepted-Finance approved |
| 3 | L3₹14.3 LAccepted-Finance | ₹14.3 L | L3 | Accepted-Finance approved |
| 4 | L4₹14.5 LAccepted-Finance | ₹14.5 L | L4 | Accepted-Finance approved |
| 5 | L5₹14.7 LAccepted-Finance | ₹14.7 L | L5 | Accepted-Finance approved |
Tender Value
₹20.1 L
EMD Value
₹40,170
Closing Date
20 Feb 2026, 3:00 pmClosed
Sh. Vivek Verma
Executive Engineer, Education Maintenance Division, Central and New Delhi, PWD (GNCTD), I.P. Estate, New Delhi
EOR Work at SBBV C C Colony Civil Lines Delhi School ID 1309001 SH Renovation of CWSN Toilet Uplift work of main Gate ic provision of Ramp Stair case Toilet Path Signages
2026_PWD_286872_1
19(Modified)/EE(Edu.)/M./C ND/PWD/2025-26
Open Tender
Civil Works
30 days
work
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹40,170
21 Feb 2026
13 Feb 2026
20 Feb 2026
13 Feb 2026
20 Feb 2026
13 Feb 2026
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 sqm
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand)
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 15 mm nominal dia Pipes
20 mm nominal dia Pipes
25 mm nominal dia Pipes
Providing and fixing brass bib cock of approved quality : 15 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Grading roof for water proofing treatment with Cement mortar 1:4 (1cement : 4 coarse sand)
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
Less DSR 2023 correction factor i.e.(1- 0.973) on existing items of DSR 2023 (i.e. Item no 1 to 29)
Add cost index @ -0.09% on DSR 2023
Providing and laying building entrance/tactile layout/emergency evacuation layout on the wall or with any other required structure with provision of multilingual text integral with 4 mm thick blue acrylic base plate with min 0.5 mm aluminium sheet at the back with upper case san serif words made of white acrylic non glare cut out letters of height 15 mm raised above base plate be not less then 0.8 mm and the equivalent words written in Hindi/any language as required with same specifications with grade 1 Braille to be integral with the sign face and should be raised 0.5 above acrylic base plate. Each signboard as per the harmonized guidelines & space standards for barrier free built environment for persons with disability, issued by MOLD. Govt of India. as per approved drawings and complete as per the direction of Engineer-in-Charge. ii) Size of the signboards shall be proportional to the layout plan of the perticular building, min size of the above signboards shall not be less than 1200 mm x 750 mm
Providing and fixing signage on the wall or with any other required structure, with provision of multilingual text integral with 4 mm thick blue acrylic base plate with min 0.5 mm aluminium sheet at the back with upper case sasb serif words made of white acrylic non glare cut letters of height 15 mm, raides above base plate by not less than 0.8 mm and the equivalent words wrtitten in Hindi/ any language as required with some specifications with grade 1 Brailke to be integral with the sign face should be raised 0.5 mm above acrylic base plate. Each signboards for barrier free buikt environment for persons with disability, issued by MOUD. Govt of India. and as per approved drawings and complete as per the direction of Engineer-in-charge. Note i) Payment for strructure, if required, shall be paid seperatelly. ii) The above nomeneclature shall be applicable for all types of signage like. a) Identification signage (For E.g. Room names/toilet facility/drinking water/staircase/Entry/Exit/ Lift etc) of the size 150 mmx 230 mm of 200 x 200 mm). b) Floor directions (singboard placed near the Lift/Staircase/Entry to the perticular floor indicating the facilities on that floor. These are normally also called as directioned signage). Min size of these boards shall not be less than 450 mm x 450 mm). c) Emergency exit sign boards (Generally used text as "in case of emergency, Do not use the lift". "Emergency Exit" etc.)
Providing and laying Tactile tile (for vision impaired persons as per standards) of size 300x300x60 mm having with water absorption less than 0.5% and conforming to 1S:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc, laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
Providing and fixing High strength adhesive tape and durable waterproof anti skid tape of size (50 mm wide) for steps outdoor and indoor usage prevents slip on your slippery surfaces. You can put anti slip traction tape an wood, tile, ladder, deck ramp, patio stair which require extra foot traction Anti skid tape for steps outdoor helps create a safer environment for walking, working, stepping and standing. complete in all respect to the entire satisfaction of Engineer-in-Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.54 MB
Tendernotice_1.pdf
Tender Documents • 1.54 MB
BOQ_379935.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid