Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC MANDI PILIBANGA HANUMANGARH RAJ | HANUMANGARH | RAJASTHAN | 335063 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹25.8 L+₹3,860 (0.15%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹26.6 L+₹89,701 (3.49%)Rejected-Finance HOUSE NO 8 589 BEHIND PHC HOSPITAL OLD BUS STAND KORBA KORBA CHHATTISGARH 495678 | 495678 | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹27.0 L+₹1.2 L (4.85%)Rejected-Finance SPECIAL 1 INDUSTRIAL ESTATE NEW POWER HOUSE ROAD JODHPUR 342003 | JODHPUR | RAJASTHAN | 342003 | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L6₹31.4 L+₹5.7 L (22.2%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L6 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹36.8 L
EMD Value
₹73,560
Closing Date
24 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Banar
Garrison Engineer, Banar, Jodhpur-342027
SPL REPAIR TO LT CABLES AND ACCESSORIES OF PERIMETER AND INSIDE DEPOT AREA AT AA BANAR UNDER GE BANAR
2022_MES_545656_2
8822/32/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Banar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer, Banar
₹73,560
Yes
6 Oct 2022
3 Sept 2022
26 Sept 2022
3 Sept 2022
24 Sept 2022
10 Sept 2022
Amount
Supply, laying,testing, commissioning in replacement of LT under ground cables of 1100 volts grade XLPE insulated, PVC sheathed heavy duty armured with multi stranded aluminum conductors with IS-7098 Pat I marked laid in trenches or fixed to wall/ poles, passing through pipe, of cross sectional area 16 Sqmm x 2 Core complete all as specified. Note : (i) The heavy duty lugs/thimbles to crimp the LT cable shall deemed to be included in the quoted rate. (ii) Excavation & earth work shall be measured & paid separately.
Taking down old unservieable LT UG cable and Supply, laying,testing, commissioning in replacement of LT under ground cables of 1100 volts grade XLPE insulated, PVC sheathed heavy duty armured with multi stranded aluminum conductors with IS-1554 marked laid in trenches or fixed to wall/ poles, passing through pipe, of cross sectional area 25 Sqmm 4 Core complete all as specified. Note : (i) The heavy duty lugs/thimbles to crimp the LT cable shall deemed to be included in the quoted rate. (ii) Excavation & earth work shall be measured & paid separately.
All as per item No-02 above but 35 sq mm 3.5 core
All as per item No-02 above but 70 sq mm 3.5 core
Supply and errecting in replacement of Prestressed concrete pole, 9.0 metre long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 including painting alternative black & white strips of 30 cm width upto 1.5 mtr above ground level and including dismantling and taking out the damaged/old PCC pole and setting aside within 50 mtr distance and dismantling the street light bracket/crossarms with connected items including street light fitting from old pole and refixing the same on new pole all as required at site and directed by Engr-in-charge.
S&F in replacement of 40 mm dia GI pipe bracket (light grade) bent to shape of length not less than 1.2 mtr including fixing on wall/pole using flat iron clamps of suitable size ,nuts,bolts,washers etc includig painting with two coats of aluminium paint over one coat of red oxide primer all as specified and directed by Engr-in-charge.
Supply and Fixing in replacement of loop-in/loop-out box of outer minimum size 300x200x120mm made out of FRP body (hot moulded type) with IP-66 protection and locking with screws comprising of aluminum bus bar rating 100 Amp, 4 strips for 3 phase and neutral along with 6 Amp rating MCB SP-1 No and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and outgoing cables and embossing /painting of danger notice of size not less than 10cmx7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of box body complete all as specified.
Supply and Fixing in replacement of Rigid non-metallic PVC conduit 20 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends andfixing accessoriessuch as couplers, locknuts, saddles, pipe hooks etc on steel tubular/PCC/RCC Poles complete all as specified and directed.
Supply and installation, testing and commissioning LT feeder pillar box in replacement suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC Supply System confirming to IS:8623/93, outdoor type floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 400A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The feeder pillar box shall be front and rear opening and having inner & outer shells. The inner shell duly compartmented for each control gear, including Powder coating internal & external surfaces. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 60 cm from the ground level made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears (Note: (i) The size of Feeder pillar box should not be less than 1100x1050x450mm, (ii) Cost of PCC platform 50mm thick 1:2:4 Type B-1 over 75mm thick sub base 1:5:10 type E-2 using 40mm graded stone aggregate is inclusive in the rate quoted for this item. (iii) Drawing of LT Panel shall be submitted by the contractor for approval of Accepting Officer before placing order. (iv) The gap of bus bar to bus bar should not be less than 40mm and bus bat to panel body should not be less than 50mm. INCOMING (a) MCCB 4 Pole 415 Volts thermal adjustable type 36 KA 250 Amp rating -01 No (b) Ammeter 0 to 300 Amp digital type with suitable ratio of CT's. (c) Voltmeter 0 to 500 volts digital type having arrangement to check phase to phase, phase to neutral (d) RYB LED indicating lamp panel mounting type (Set of three) - 01 No. (e) Bus bar chamber having insulated aluminum bus bar 400 Amp and neutral. (f) Chamber of suitable size for incoming and out going cablees with arrnging of suitable size cable glands. OUTGOING (a) MCCB 4 Pole 415 Volts thermal adjustable type 36 KA 160 Amp rating-01 No (b)MCCB 4 Pole 415 Volts thermal adjustable type 16 KA 100 Amp rating -01 No (c) Isolator TPN, 415 Volts 16 KA 63 Amp rating-02 No
Supply and installation, testing and commissioning LT feeder pillar box in replacement suitable for 415 Volts ,3 Phase 4 Wire, 50 Hz AC Supply System confirming to IS:8623/93, outdoor type floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3.15 mm thick having Aluminium bus bar of rating 300 A, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The feeder pillar box shall be front and rear opening and having inner & outer shells. The inner shell duly compartmented for each control gear, including Powder coating internal & external surfaces. All the covers shall be provided with suitable locking arrangements, mounted on angle iron stand fixed at 60 cm from the ground level made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, and comprising of the following controls gears (Note: (i) The size of Feeder pillar box should not be less than 1100x1050x450mm, (ii) Cost of PCC platform 50mm thick 1:2:4 Type B-1 over 75mm thick sub base 1:5:10 type E-2 using 40mm graded stone aggregate is inclusive in the rate quoted for this item. (iii) Drawing of LT Panel shall be submitted by contractor for approved of Accepting Officer before placing order. (iv) The gap of bus bar to bus bar should not be less than 40mm and bus bat to panel body should not be less than 50mm. INCOMING (a) MCCB 4 Pole 415 Volts thermal adjustable type 36 KA 160 Amp rating -01 No (b) Ammeter 0 to 300 Amp digital type with suitable ratio of CT's. (c) Voltmeter 0 to 500 volts digital type having arrangement to check phase to phase, phase to neutral (d) RYB LED indicating lamp panel mounting type (Set of three) - 01 No. (e) Bus bar chamber having insulated aluminum bus bar 300 Amp and neutral. (f) Chamber of suitable size for incoming and out going cablees with arrnging of suitable size cable glands. OUT GOING (a) MCCB 4 Pole 415 Volts thermal adjustable type 16 KA 100 Amp rating -02 No (b) MCCB 4 Pole 415 Volts thermal adjustable type 16 KA 63 Amp rating -01 No (c) Isolator TPN, 415 Volts 16 KA 63 Amp ratingP-02 No
S&F LED Security light fitting in replacement made out of pressure die cast aluminium powder coated housing high impact resistant 4mm thick toughened glass cover and matrix of power LEDs inbuilt electronic driver up to 10 KV surge protection fitted with adjustable pole adapter to enable on site tilt angle setting depending on road geometry CCT 5700-6000 CRI greater than 70, IP 66, PF >0.95,THD < 5%,input power 60 W system with 100 lumens per watt output operating voltage 160-260V with connection by three core PVC insulated multistaranded copper conductor sheathed cable of size 1.0 SQMM fixed with & including bracket made of GI Pipe 40mm bore light grade , 1.5 Mtr long bent to shape required with 2 Nos MS clamps of suitable size and length, nuts & bolts complete all as specified and as directed.
S&F LED Security light fitting in replacement made out of pressure die cast aluminium powder coated housing high impact resistant 4mm thick toughened glass cover and matrix of power LEDs inbuilt electronic driver up to 10 KV surge protection fitted with adjustable pole adapter to enable on site tilt angle setting depending on road geometry CCT 5700-6000 CRI greater than 70, IP 66, PF >0.95,THD < 5%,input power 90 W system with 100 lumens per watt output operating voltage 160-260V with connection by three core PVC insulated multistaranded copper conductor sheathed cable of size 1.0 SQMM fixed with & including bracket made of GI Pipe 40mm bore light grade , 1.5 Mtr long bent to shape required with 2 Nos MS clamps of suitable size and length, nuts & bolts complete all as specified and as directed.
M&L for earthing complete in repairs with galvanised steel earth plate electrode size 600x600x6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead wire 4.0 mm dia means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering pipe with funnel, wire mesh, common salt, charcoal, necessary excavation and earth work and PCC cover with handle, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.
Earthing complete in repairs with Galvanised Steel earthplate of size 60x60cmx6mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, connected to earth test terminal point all as specified or as indicated including testing on completion (Rates inclusive of neccessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing). Note: Testing of earthing shall be carried out after completion of earthing.Payment for earthing shall be admissible after satisfactory test result.
Supply and connecting in replacement PVC wire 4 sqmm nominal area 2 Core multi stranded aluminum conductor PVC sheathed and weather proof round/flat shape and drawn through PVC conduit and connecting to Street light fittings on PCC/RCC/Steel pole all as specified.
Supply and fixing in replacement GI Pipe medium grade 80 mm dia with necessary accessories/ fittings bracing with pol/wall by FI clamps made with 32x6mm for cable protections/pole for crossing of culverts/nallah and all as specified.
All as per ser item No 16 above but of size 50 mm dia
M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching with the surroundings complete all as directed.
Material and labour plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in base of the pole as a foundation or in any situation all as specified.
Material and labour plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of the pole by demolition of existing /broken coping with taking out the LT cables and GI pipe Etc and refixing in new coping or in any situation all as specified.
Excavation in trenches in soft/ loose soil n.exc 1.5mtr wide and not exc 1.5mtr in depth and getting out complete all as specified and directed.
All as per item No 21 here in before but exc 1.5 mtr or part there of in depth beyond the first 1.5 mtr depth complete all as specified and directed by Engineer-in-Charge..
Material and labour for Sand cushioning/ Sand covering using Tibba sand for underground cable protection complete all as specified and directed by Engineer-in-Charge. Note :- For the purpose of payment, only punned thickness which comes out 18 cm will be measured.
Supply and laying reinforced precast concrete cable cover, class LV, Type 1, flat, size 250mmx150mmx40mm laid perpendicular to cable length in trench air gap should not more than 5mm to each other after sand cushioning to cable and all as specified.
Returning, filling, in including spreading, leveling , watering and well ramming in layers n.exc 25 cm in soil complete all as specified.
Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified.
M/s Vishaka Enterprises
M/s Bhagwati Construction Company
INDO CONSTRUCTION
Anil Builders
Shri Electrical Enterprises
NISHA CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .