Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹43.6 L+₹3.2 L (7.80%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹44.4 L+₹4.0 L (9.86%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹47.0 L+₹6.6 L (16.4%)Rejected-AOC HQ CE SC PUNE | PUNE | MAHARASHTRA | 410301 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹51.0 L+₹10.6 L (26.2%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
31 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
PROVISION OF AGE B/R OFFICE AT INAZ VILLAGE VERAVAL UNDER GE I CG PORBANDAR
2021_MES_493402_1
8679
Open Tender
Civil Works
Item Rate
180 days
Veraval
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE I CG Porbandar
₹82,000
Yes
8 Feb 2022
9 Dec 2021
1 Jan 2022
9 Dec 2021
31 Dec 2021
23 Dec 2021
9 Dec 2021 - 22 Dec 2021
60 days
Amount
SCHEDULE 'A'
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out In hard / dense Soil.
Excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. and getting out any type of soil.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and depth exc., 1.5 m and n. exc., and getting out in soft/ loose soil, complete all as specified and directed.
M&L Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area.
M&L Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface
M&L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
M&L for PCC 1:4:8 type D2 (using 40mm graded aggregate) in foundations, filling and mass concrete, complete all as specified and as directed by Engr-in-Charge.
M&L RCC M-30, using 20 mm graded stone aggregate for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed.
Use and waste of formwork to the sides of concrete footing, base of columns, plinth beams and similar work for vertical or to batter rough finished surfaces of concrete .
M&L RCC M-30, using 20 mm graded stone aggregate, as in Columns, pillars, piers, posts and struts, complete all as specified and directed.
Use and waste of formwork to the sides of rectangular columns for rough finished surfaces of concrete.
M&L RCC M-30, using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed.
Use and waste of formwork to sides and soffits of beams, bands and the like for rough finished surface of concrete.
M&L RCC M-30, using 20 mm graded stone aggregate, as in chajja & canopy, complete all as specified and directed.
M&L RCC M-30, using 20 mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Mild steel CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips
Mild steel CRS TMT bars 6mm to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for slabs, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips, complete all as specified and directed.
All as per item No. 5 here-in-before, but but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm as in soft/loose soil.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering
Removal of excavated soil to a distance exc. 500m but n.exc 1000 mtr and depositing where directed at level n exc. 1.5M above the starting point. all as specified.
M & L Porbandar stone masonry, well bonded, bedded and solidly hearted built in CM 1:6 all as specified and as directed by Engineer-in-charge.
M&L for rendering 15mm thick, cement plaster, in cement mortar (1:4) mixed with integral water proofing compound as per manufactures instruction, on roof slab surfaces finished even and smooth without using extra cement,complete all as specified and directed. Note:- Water proofing compound shall be measured and paid separately)
Supply only liquid water proofing compound as per manufacturer's instructions and as directed by Engr-in-Charge.
M&L for rendering 10 mm thick on fair face of brick work or concrete surfaces in CM 1:6 finished even and smooth wiithout using extra cement.
M&L for rendering 5mm thick cement plaster in cement mortar 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement on ceiling in any height complete all as specified and directed.
M&L preparation of surfaces and applying three coats of white wash on new plastered surfaces of wall complete all as specified and as directed.
M&L preparation of surfaces and applying three coats of white wash on new plastered surfaces of ceiling complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as per the manufacturers instructions, complete all as specified and directed by Engr-in-charge.
M&L for preparation of newly plastered surfaces of wall and applying two coats of OBD over a coat of chalk white primer, complete all as specified and directed.
M&L for preparing new wooden surfaces of any description, not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer of approved shade all as specified and directed.
S&F For 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed, complete all as specified and directed.
M&L for Preparing surfaces of wooden work of any description and girth, not otherwise described, and treated with tar or coal tar black paint, complete all as specified and directed.
S&F 35 mm thick flush shutters solid core construction with block board core and pre-laminated on both sides, complete all as specified and directed.
S&F powder coated aluminium anodised three track sliding window shutter and frame including jointing cleat for fixing frame/chowkhat of window as per JINDAL section code (frame 20831), shutter (20846) including glazing with 4mm thick tinted glass (02 shutters) & SS wire mesh (01 Shutter) necessary fittings, rubber packing, suitable handles, rollers for shutters etc complete all as specified and as directed.
S&F Anodized aluminium grills of type Doco grill DG 104 or equivelent with Aluminium section of size 7.5mm x 6 mm with necessary channels and clips all as specified & directed.
S& F factory made slid PVC door frame of size 50mmx47mm made out of 5mm wood grain printed, decorative PVC sheet reinforced with MS square tube and edges painted to match with printed sheet complete all as specified and directed by Engr-in-charge .
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tube for top & bottom rail. MS frame shall be covered with heat moulded PVC”C” channel having a PVC steel strip of 20mm width stuck inside with solvent cement for style and plain coloured PVC sheet for top rail lock rail &bottom rail on either side &as gap insert for top rail and bottom rail paneling of plain coloured PVC sheet to be fitted in MS frame welded / sealed to style &rails with suitable PVC sheet beading and jointed together with solvent cement, supplying and fixing in the frames at site as per specification & drawing.
M&L for 200 mm long 10 mm dia Aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed.
M&L for 150 mm long 10 mm dia Aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed.
M&L for 150 mm extruded aluminium alloy handles, fabricated type, anodised, complete all as specified.
M&L for 100mm long stainless steel Butt hinges, best quality, complete all as specified and directed.
M&L for MS work such as Bands, Straps, Hold fast, Clamps, Hooks & similar Fe-410-O or Fe-310-O, complete all as specified and directed by Engr-in-Charge.
S&F 200 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed by Engr-in-Charge.
S&F for Harrison rails, aluminium alloy with fixing brackets, stops, rollers etc., complete all as specified and directed by Engr-in-Charge.
M&L For Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M&L for 100 mm thick PCC (1:3:6) type C2 using 40 mm graded aggregate as in sub bases of flooring, complete all as specified and directed.
M&L For 75mm Thick PCC (1:3:6) type C2 using 40 mm graded aggregate, as in plinth protection, complete all as specified and directed by Engr-in-Charge.
M&L 18mm to 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over screed bed or bedding layer of 15 mm thick 1:6 etc. complete all as specified and as directed by Engr-in-Charge
M & L Glazed coloured ceramic tiles in vertical surface 350x250x7mm/ 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles, complete all as specified and as directed.
M&L For Non - skid Ceramic Coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15 mm thick screed bed in C M 1:6 for laying floor finishes etc complete all as specified and directed.
Ditto all as above Item but for work on vertical surfaces such as skirting, dados and risers to steps etc complete.
M&L For Non - skid Ceramic Coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15 mm thick screed bed in C M 1:6 for laying floor finishes etc complete all as specified and directed.
S&F vitreous china wash down water closet (pedestal pattern) with plastic seat and cover including PVC low level flushing cistern 10 ltrs capacity complete as directed by Engr-in-Charge.
S&F Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern
S&F Stop valves, chromium plated, cast copper alloy, screwed down, high pressure, fancy type, screwed both ends for iron pipe or for unions and fixed for 20 mm bore pipes, complete all as specified and directed by Engr-in-Charge.
S&F PVC connections 15mm size with PTMT nuts of length 600mm
S&F Fancy Type C.P. Bib taps, cast copper alloy, screwed down, screwed for iron pipe or for brass ferrule and fixed.
S&F S.S. body health faucet
S&F Toilet paper holder, vitreous China,box type
S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)
S&F Bottle trap of PTMT having minimum water seal of 25mm. (Minimum weight 32mm-260gms/ 40mm-270 gms), complete all as specified and directed by Engr-in-Charge.
Supplying and laying of CPVC pipes of size 25 mm outer dia SDR-11 & Plain CPVC SDR 11 fittings fixed complete to walls, ceilings or in floors. complete all as specified and as directed.
Supplying and laying of CPVC pipes of size 20 mm outer dia SDR-11 & Plain CPVC SDR 11 fittings fixed complete to walls, ceilings or in floors. complete all as specified and as directed.
S&F Vitreous China wash basin, angle back, size 600mmx480mm white, excluding taps, waste, chain and plug and orcelain stopper but including brackets
S&F 15 mm fancy type, Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and directed by Engr-in-Charge.
Gun metal globe or gate valves of 20 mm dia with iron wheel head screwed both ends for iron pipe, complete all as specified.
S&F HDPE pipes or pressure rating 6kgf/sqcm of 40 mm dia fixed/concealed on walls or floors all as directed by Engr-in-Charge.
S&F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats(Minimum weight 190gms)
S&F rotational moulded polythylene water storage tanks of capacity 500 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified and as directed.
S&F 25 mm bore, Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
S&F 110 mm PVC (SWR) pipes double socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F 110 mm PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls
S&F 75 mm PVC (SWR) pipes double socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F 75 mm PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to walls
S&F PVC (SWR) vent cowl 110mm
M&L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement.
S&F PVC (SWR) bends any radius 110mm
S&F PVC (SWR) branch piece 110mm single (single Y) equal or unequal, with access door.
S&F PVC (SWR) bends any radius 75mm
S&F PVC (SWR) floor trap with grating incl jointing to waste pipe with dia of outlet 75mm.
Excavating in trenches, n exc. 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil, complete all as specified and directed.
M&L for PCC (1:3:6) type C2 using 40 mm graded aggregate as in flooring, complete all as specified and directed.
M&L for PCC (1:2:4) type B1 using 20 mm graded aggregate as in flooring, complete all as specified and directed.
Forming contraction /dummy joints of 65mmx10mm wide primed & filed with sealing compound of bitumen ((VG-30) & sand in 1:3 Mix, complete all as specified and directed by E-in-C
M&L for spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green, complete all as specified and directed.
M&L for Cement concrete 1:2:4, type B1 (using 20mm graded aggregate) in benching for manholes including necessary form work and finishing of exposed surfaces of concrete all as specified and as directed by Engr-in-Charge.
M&L for precast cement concrete (1:2:4) type B1 (using 20mm graded aggregate) as in cover slabs for manholes etc including necessary form work and set in CM 1:4, complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required, complete all as specified and directed.
M&L for 75mm thick Plain Cement concrete 1:3:6, type C-2 (using 40mm graded aggregate) as in sub base of floors all as specified
M&L for laying machine pressed precast conctete interlocking reflective coloured pavers block any shape and size confirming to IS 15658-2006 of 55mm to 60mm thick, M-35 Grade, including interstices filling with fine sand etc., complete all as specified and directed by Engr-in-Charge at site.
M&L for 25mm thick sand layer for laying interlocking paver blocks all as specified and directed by Engr-in-Charge at site.
M&L cement concrete type B-1 (1:2:4) using 20 mm graded stone aggregate as in coping, moulded or chamferred edges and like complete.
M&L cement concrete type B-1 1:2:4 (using 20mm graded stone agg) in surface channels and drain.
M&L for Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire suitable for modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:-
One light /fan point controlled by one, one way switch
One 3 pin 6 Amps socket outlet on same board
One 3 pin 6 Amps socket outlet on independent board .
M&L for Point wiring complete with 2.5 Sq mm single core PVC insulated but unsheathed multistrand copper conductor FRLS cabeI 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISi marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 2.5 Sq mm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board, suitable for modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets with required modules all as specified.
Supply & fix modular switch 1 way, 6 Amps, 1 modular (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
Supply & fix modular switch 1 way, 16 Amps, 1 modular (ISI marked).complete all as specified and as directed.
Supply & fix modular socket, 6 Amps, 2/3 pin combind 2 module (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
Supply & fix modular socket, 6/16 Amps, 2/3 pin combind 2 module (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
Supply & fix modular fan regulator, 120 watt, 2 moduler (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
Supply & fix ceiling rose, surface bakelite, 65 x 17 mm three terminals (ISI Marked) complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
Supply and fix modular cover plate with frame, 2 module. Make : Legrand / Anchor (Roma)/ L&T
Supply and fix modular cover plate with frame, 3 module. Make : Legrand / Anchor (Roma)/ L&T
Supply and fix modular cover plate with frame, 8 module. Make : Legrand / Anchor (Roma)/ L&T
Supply and fix modular metal flush box 1/2 module. Make : Legrand / Anchor (Roma)/ L&T
Supply and fix modular metal flush box 3 module. Make : Legrand / Anchor (Roma)/ L&T
Supply and fix modular metal flush box 8 module. Make : Legrand / Anchor (Roma)/ L&T
S & F in of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed. Make Wipro - CAT PT No- LL20-281-XXX-65AL1** or equivalent to Bajaj/Havells
S & F in of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed. Make Wipro - CAT PT No- LL20-111-XXX-65NE3* or equivalent to Bajaj/Havells
Supply & fix BEE star rated Ceiling fan 1200 mm sweep and connecting up to and including provision of 23/0.0076 flexible three core PVC insulated copper conductor cable from ceiling rose to fan etc complete all as specified and as directed. make: Orient, CG, Havells, Usha
Supply and fix Exhaust fan 300 mm sweep 240 V AC metal body fixed as per maufacturers instruction, connecting with and including 2 core x 0.5 Sqmm copper coduct PVC insulated and PVC sheathed three core cable complete or equivalent. make: Orient, CG, Havells, Usha
M&L for sub main wiring with two single core 4 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit with all accessories, PVC insulated 2.5 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
M&F for MCB DB made of sheet steel phosphatised, powder painted with bus bar 200A, neutral link, with double door, 415 volts TPN 4 way, IP-43-IK-09 with metal door including concealed, cutting chases exc 10 cm but not exc 20 cm girth for DB and making good disturbed surfaces complete all as specified and as directed. Make : Legrand/ Havells/ ABB
S & F MCB TPN 63 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity complete all as specified. Make : Legrand/ Havells/ ABB
S & F of MCB DB 8 way SPN, double door, vertical type, IP - 53 with 200 Amps rated bus bar, Concealed and connecting up complete all as specified. Make : Legrand/ Havells/ ABB
S & F of MCB SPN, 240 volt, 32 Amps complete all as specified. Make : Legrand/ Havells/ ABB
S & F of MCB SP, 240 volt, 6 to 32 Amps complete all as specified. Make : Legrand/ Havells/ ABB
S & F of Earthed metal clad socket outlet with earthed plug top 20 Amps capacity with sheet metal enclosure and one 20 Amps MCB SPN all as specified and directed. Make : Legrand/ Havells/ ABB
Supply, laying and jointing GI tubes 25 mm bore medium grade in any lengths with screwed and socket joints, together with all galvanised steel fitting such as sockets, elbows, bends, tees, reducers, unions, cap plugs, nipple, short pieces etc fixed complete by means of and including clips, wall hook etc or laid in trenches all as specified and directed. Make - Tata/Jindal/Surya Prakash
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
S & F Gun metal gate valve of size 25 mm dia with iron wheel head screwed both ends for iron pipes complete all as specified and directed.
M & L for cutting of existing DI/CI Pipe in position for inserting CI Tee complete with 50 mm dia union, nipple, etc all as directed for taking 25 mm GI branch line complete all as specified and directed.
M & L for Construction of new valve chamber of size 900 X 900 X 900 mm including necessary earth work in any type of soil, PCC foundation C-2 1:3:6 in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 6 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made-out of 40 X 40 X 6 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all metal works & two coats of white wash on all plastered surfaces of valve chambers complete all as specified and directed by EIC.
Supply and laying of XLPE insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 25 Sqmm 4 Core laid in trenches/along the wall/pole including making good the disturbed surfaces of walls/floor etc all connections complete as required at site and as directed. Make : Polycab / Havells/ RR Kabel
S & F of GI steel tubing light grade 32 mm dia for laying in ground and road crossing along the pole in coping etc for cable protection including necessary fittings, clamps for supports, etc., including making good the disturbed surfaces of walls/floor etc all as specified and directed. Make - Tata/Jindal/Surya Prakash
Supply and lay 50 /38 mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables, laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge. Make : Rex / Poly/ Gemini
M&L for cutting existing road/hard standing not exc 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil complete all as specified and directed.
Supply and Fix MCCB Metal enclosures, MCCB FP 63/100 Amps 415 Volts 16 KA fixing in Metal enclosure, in wall mounted type concealed/ Surface mounted and making good the disturbed surfaces of walls/ceiling/floor etc. complete with all accessories, main switch and connecting the cables with proper all as specified and directed by Engineer in Charge. Conforming to Cat No - 5078 01 & 4200 13 of Legrand or Equivalent from ABB/Havells/Schneider
M&L for bore Earthing, 150 mm bore for earthing with maintenance free chemical earthing using copper electrode of size 19 mm dia - 01 No, 3 m long, Copper earth strip, excavation and earth work, back fill with compound (Chemical for earth enhancer gel 2 x 25Kg) - 01 set. all as directed, shall be deemed to be included in the unit rate. Note: (i) IR Value should be less than 1.0 ohm. (ii) Copper earth stip of size 25 x 3 mm including installation 7.5 m (Copper purity not less than 99%) is deemed to be included in the unit rate. (iii) Suitable FRP Chamber should be included in the unit rate.
RAJESH ENTERPRISE
Gatral Construction Co.
K B N TRADERS
V D JADEJA
Bharat Enterprise
JAY BHARAT METAL SUPPLIERS
roxy enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .