Executive Engineer, Electric (R&B) Division, Rajkot
A&A to E.I. , LED Tubelight & BLDC Ceiling Fan in Tagore and Markoni Boys Hostel of AVPTI College at Rajkot.
364225
11 of 2026-27
Open
Electrical Works
Works
Rajkot
8 documents required · 8 mandatory
₹900
Executive Engineer, Electric (R&B) Division, Rajkot.
₹11,000
6 Nov 2026
6 Nov 2026
6 Nov 2026
20 Nov 2026
6 Nov 2026
90 days
Name of work: A&A to E.I. , LED Tubelight & BLDC Ceiling Fan in Tagore and Markoni Boys Hostel of AVPTI College at
Item Quantities estimated but Item of work Tendered Rate Total amount
Item Quantities estimated but Item of work Tendered Rate Total amount
No. may be more or less according to
Qty. Unit estiamted
Replacing Old & u/s by Point wiring for Light / Bell with 2-
1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 kV grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length , in below type of pipe erected with
6A Modular type switch / bell push & accessories and earth
continuity of following type, erected on PVC /
1 220.00 Pt. Metallic/Wooden box, single mounting base frame covered 539.34
with textured/metallic/white front plate modules erected on / in
wall / ceiling as per pipe erected, with necessary Lamp
holder/ceiling rose / H.D.Connector as directed (a) with
medium class Rigid PVC pipe and accessories erected flushed
on wall/ceiling complete Cat-III
9.00 Pt. Light Point ( Bathroom , Toilet , Washarea ) 269.67
Replacing Old & u/s by Point wiring for FAN with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (Green) both are of .ISI
marked 1.1 KV Grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type of pipe erected
with 6A Modular type switch and hum free EME step type
electronic fan regulator mounted and accessories with earth
2 101.00 Pt. continuity of following type erected on PVC / 765.58
Metallic/Wooden box, single mounting base frame covered
with textured/metallic/white front plate modules erected on / in
wall / ceiling as per pipe erected. with necessary ceiling rose /
H.D.Connector as directed (a) with medium class Rigid PVC
pipe and accessories erected flushed on wall/ceiling complete
Replacing Old & u/s by Point wiring for Individual Plug with
& earth wire of 1.5 sq.mm (Green) both are of ISI marked
kV grade FRLS PVC insulated multi strand copper wires up to
10 mtr length, in below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate front plate
modules erected on / in wall / ceiling as per pipe erected with
following type of accessories. [I] For 6A Plug and 6 a switch
with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db
board (a) with medium class Rigid PVC pipe and accessories
erected flushed on wall/ceiling complete Cat. III
[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu.
Wire from mcb db board.(a) with medium class Rigid PVC
pipe and accessories erected flushed on wall/ceiling complete
Replacing Old & u/s by Point wiring for on board Looped Plug
with 6A Modular type switch & 5 pin socket erected on PVC /
Metallic/Wooden box, single mounting base frame covered
with textured / metallic/white front plate modules erected on /
in wall / ceiling with following type accessories Cat. III
Point wiring for Two Way Controlled Light Point with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (green) both are of .ISI
marked 1.1 kV grade FRLS PVC insulated multi strand copper
wires erected in below type of pipe with 6A Modular type
switches and following type of accessories erected on PVC /
Metallic/Wooden box, single mounting base frame covered
with textured / metallic/white front plate modules erected on /
in wall / ceiling as per pipe erected. with necessary
batten/angle holder or ceiling rose or H.D.Connector as
directed (a) with medium class Rigid PVC pipe and accessories
erected flushed on wall/ceiling complete Cat. III
Providing & erecting PVC Corrugated Flexible Conduit with
6 250.00 Mtr. required nos. of coupling, PVC bushes, Check-nuts etc. 21.21
complete of following sizes.(2) 25 mm
Replacing Old & u/s by Providing and erecting Mains with
kV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected
concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour
for earth continuity of following size (A) With medium class
Rigid PVC pipe and accessories (b) 2 wire 2.5 sq. mm
Item Quantities estimated but Item of work Tendered Rate Total amount
Item Quantities estimated but Item of work Tendered Rate Total amount
No. may be more or less according to
Qty. Unit estiamted
Replacing Old & u/s by providing and erecting Mains with
kV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected in / on
8 505.00 Mtr. wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC 184.83
insulated stranded wire of green colour for earth continuity of
following size (A) with medium class Rigid PVC pipe and
accessories (b) 2 wire 6 sq. mm
Replacing Old & u/s by Supplying and erecting LED indoor
fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled
on single MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS: 513/CRCA/
aluminium die cast powder coated and high U.V. & corrosion
resistance with diffuser with company mark/name 160V to
270V, Power Factor more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
9 237.00 Ea. Luminaire efficacy> 85 lumens/watt ,LED 535.30
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.) (A) Tube Light with integral driver
(v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet Cat-lll
Replacing Old & u/s by Supplying and erecting LED street
light / Flood light fittings with High power White LEDs
wattage of 3 Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %.( fittings required
LM-79 & LM-80 certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity between the
ranges shown.) (A) Street Light (IP-65), Surge protection -4KV
integral and ,Light must have 440VAC line supply with over-
voltage protection. (iv) 90 - 119 watts Cat-lll
Replacing Old & u/s by providing and erecting Miniature
circuit breaker single pole 6A to 25A suitable to operate on
11 96.00 Ea V A.C. system and having breaking capacity 10 KA to be 123.22
erected in existing box. confirming to IS 8828/1996 with ISI
Replacing Old & u/s by Providing and erecting Sheet Steel
powder coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link, earth bar and DIN rail,
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to
house appropriate nos. of MCBs.(The DBs should be used of
same company of MCB to be used) suitable for (A) single
phase incoming and horizontal single phase outgoing (b) sheet
steel double door (IP-43) (iv)12 way
Providing & erecting 240 V MCB double pole switch for
lighting Load (B Curve) having 10 KA breaking capacity &
confirms to IS : 8828 in existing box having following capacity
(B) 40 Amp. Cat.III
providing and erecting Approved make RCCBs conforming to
IS: 12640 and having sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for operation on
14 12.00 Ea single phase 240 V,50Hz. having characteristic of quick action 2458.34
& tripping with all advance feature & do not incorporate any
electronic component. for following Max. rating erected as
directed (ii) 40Amps. DP Cat. III
Supplying & erecting earth pit of minimum bore dia.150mm
size approved make Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 50mm having 80-
200 Micron galvanising, Inner pipe dia of 25 mm having 200-
250 Micron galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for following
type of applications with chamber and heavy duty cover.
(A)(approved make OEM has to submit test certificate
including value of earth resistance of installation duly stamped
and signed by agency and officer Incharge has to ensure the
value of earthing resistane mentioned in test Certificate) &
having back filling compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC
62561-2017, Voltage drop:- < 1 volt at no load & dry form,
Sulphar content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency.
Item Quantities estimated but Item of work Tendered Rate Total amount
Item Quantities estimated but Item of work Tendered Rate Total amount
No. may be more or less according to
Qty. Unit estiamted
(a) For Electrical Installation up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
Replacing Old & u/s by Supply, Installation, Testing and
Commissioning of suitable sweep, BEE 5 Star rated, Ceiling
fan with Brush Less Direct Current (BLDC) permanent ferrite
magnet Motor, class of insulation: B, Rust free
nos.Aluminium blades, 2 nos. canopies, shackle kit with
earthing provision, copper winding, Power factor not < 0.9,
Service Value (CMM/W) minimum 6.85, Air delivery
minimum 215 CMM, 350 RPM,230v (tolerance as per IS : 374-
16 101.00 Ea 2019), THD < 10%, compitible with electronic regulator unit 2629.03
for Speed Control and all remaining accessories including
safety pin, nut bolts, washers, temperature rise = 75 °C (Max.),
suitable for 140 to 285 Voltage and rectifier circuit with surge,
over current and overload protection , 50 Hz, Single phase AC
Supply, earthing etc. Complete as required.[ Make shall be
approved by Engineer in Charge] (A) 1200 mm Sweep (48")
Item Quantities estimated but Item of work Tendered Rate Total amount
Item Quantities estimated but Item of work Tendered Rate Total amount
No. may be more or less according to
Qty. Unit estiamted
Supplying and erecting 19 / 20 mm. nominal bore Medium
Class M.S. Pipe down rod erected duly painted for fan
complete with proper insulation without leakage and earthing.
Note:- The Credit of dismentalled materials for Rs.38232.00 shall be recovered from the First R.A. bill payable to the contrator and
there after the dismentalled materials shall be the property of the contractor.
I/We am/are willing to carry out the work at__________________% above/below (in
figures)_____________________________________percent Above / below (in words) the estimated rates mentioned above amount of my\our
tender works out as under :-
Estimated amount put to Tender Rs. _________
Deduct________% below Rs. _________
Net Amount Rs. _________
Estimated amount put to Tender Rs. _________
Net Amount Rs. _________
A I/We hereby declare that I/we have visited the site and fully acquainted my self / our selves with the local situation
regarding material,labour and other factors pertaining to the work before submitting this tender.
B I/We hereby declare that I/we carefully studied the conditions of contract, detailed technical specifications and other
tender documents of this work and agree to execute the same accordingly.
C Any Excess in Tender Item/Extra Item if Needs to be Execute. Contractors has to carry out work on the instruction of
Competant Authority on Tender Submitted rate,No Excuse will be Accepted.Hence Contractor are Requested to quote
the rate considering this condition.
D Contractor are requested to quote the Tender by considering that payment will be made after availibility of
grant.Contractor has to start the work immediately after issue of Work Order and as per instruction of Engineer-in-
Charge irrespective of availibility of grant.
E "This estimate has been prepared on the new SOR wich is exclusive of GST hence GST additional will be paid to the
agency as per existing guidelines."
(Signature of the Contractor)
Note 1 Please strike out whichever is not applicable.
2 In the case of tendered amount being quoted incorrectly the quoted pered percentage Below/Above will be considered
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
ANNEXURE-A (2).pdf
DM (5).pdf
MAKE FOR ELECTRICAL ITEM (3).pdf
SCH-B (3).pdf
SBD.pdf
Contractor_Registration_Paripatra__1_.pdf
EMD GR.pdf
GR for single Tender.pdf
ONLINE_NOTICE(R-2)(dn).pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .