Executive Engineer Elect BSNL Aurangabad
II nd floor Chikalthana Telephone Exchange Mukundwadi Aurangabad
Rate Contract for Repairing and replacement of faulty components of Water Pumps Compound Lights Electrical fittings Electrical Switchgears Service Cables at various TE Bldgs and BTS under BA Head Nanded
2022_BSNL_122180_1
08e/EEE-BSNL/AGB/2022-23
Open Tender
Miscellaneous Services
Item Rate
365 days
Nanded BA
Please refer Tender documents.
19 documents required · 19 mandatory
₹590
Yes
A O Cash GMT BSNL Aurangabad
₹7,023
Yes
4 Aug 2022
13 Jul 2022
28 Jul 2022
14 Jul 2022
26 Jul 2022
14 Jul 2022
14 Jul 2022 - 25 Jul 2022
Amount
A) Pumps Sets : Dismantling of existing Monobloc/ pump motor set of capacity 2 to 5 HP from pipe lines from existing foundation by using tripot and chain pulley block for repairing and servicing. Also reinstallation of the same on foundation and connecting pipe lines by using tripot and chain pulley block after repairing etc complete as required.
Dismantling of existing Submersible pump 1.5 to 2 HP from pipe lines from bore well by using tripot and chain pulley block for repairing and servicing. Also reinstallation of the same on in bore well and connecting pipe lines by using tripot and chain pulley block after repairing etc complete as required.
Repair and Servicing of following Capacity water pumps by replacement of following faulty components.
a) Rewinding of 2.0 to 3.0 HP motor with copper wire etc complete as required.
b) Rewinding of 5.0 HP motor with copper wire etc complete as required.
c) Rewinding of 1.5 HP to 2 HP submersible pump set etc complete as required.
d) 3" PVC Foot valve (75 mm dia)
e) Suction Hose Pipe 2 Inch/50 mm Green colour
f ) HDPE Bend 2"
g) HDPE Gate valve 15 mm dia
h) MK01 Pump Starter suitable up to 5 HP motor pump set
i) Ball Bearing
B) E.I. & COMPOUND LIGHTS : Visit charges for finding & attending fault including arranging special tools like ladder, drill machine etc as for rectification fault in electrical installation etc as required ( Within Muncipal Corporation )
Rectification of fault & repairing/attending of faulty points/MCBDB fault/wiring fault/cable fault including restore the supply as it required (1 Job includes attending fault and restore supply time to time whenever required) ( Out side Muncipal Corporation )
Repair of compound light, light fittings by replacement of following faulty components.
a) (i) Replacement of faulty fittings by Bajaj Cool White 36W LED Street Light, IP66, 220 V etc complete as required.
a) (ii) Supply and fixing of 30/36 watt LED lamp with ceramic holder in existing fitting after modification as required
b) 36 watt Tube rod
c) Electronic Ballast Choke
d) 5/6 Amp piano type switch
e) 5/6 Amp 5 pin univesal type Socket
f) 15 Amp piano type switch
g) 15/5Amp 5 pin universal type Socket
h) Supply & Fixing of 72 w/50 W LED compound light fitting Driver 240 V including conection testing etc as required.
Reparing of faulty Celing / exhaust fans at different location i/c rewinding of rotor and replacing of faulty bearing etc as required.
Replacement of following capacity electrical switchgears and accessories etc complete as required.
a) 100 Amp MCCB 3 Pole DU 125 MCCB
b) 100 Amp MCCB 4 Pole DU 125 MCCB
c) 63A TP MCB
d) 32 Amp SPN MCB
f) 5/6 Amp SP MCB
Replacement of following sizes faulty service cable including laying / fixing with suitable supports etc complete as required.(ISI mark)
a) 3 core x 10 Sq. MM double insulated unarmoured Aluminum Conductor Cable including laying / fixing with suitable protection etc complete as required.
b) 4 core x 10 Sq. MM double insulated unarmoured Aluminum Conductor Cable including laying / fixing with suitable protection etc complete as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing 63 amps. rating, 415V, 4 pole, front operated on load changeover switch in sheet steel enclosure on existing wall including making interconnections, testing & commissioning with dismantling the Existing burnt faulty change over switch witn supply disconnection etc. complete as required.
Replacement of faulty 63A, 2-pole,230 V, off load, with handle front operated with metal sheet enclosure Changeover switch on the existing wall with new one i/c making interconnection , Testing commissioning etc as reqd. i/c dismentling of existing faulty switch, disconnecting cables etc complete as required
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required
a) 1 x 1.5 sq. mm
b) 2 x 1.5 sq. mm
c) 3 x 1.5 sq. mm
d) 2 x 2.5 sq. mm
e) 3 x 2.5 sq. mm
Prashant Electricals & Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .