Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹32.8 LAccepted-AOC GAIRKATA ROAD WARD NO 03 PO PS DHUPGURI DIST JALPAIGURI W B PIN 735210 | JALPAIGURI | WEST BENGAL | 735210 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹34.4 L+₹26,120.60 (0.76%)Rejected-Finance 24B JYOTISH ROY ROAD KOLKATA 700053 | KOLKATA | WEST BENGAL | 700053 | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹37.4 L+₹3.3 L (9.60%)Rejected-Finance BIRPARA LANKA ROAD PO BIRPARA DISTT JALPAIGURI PIN 735204 | BIRPARA | JALPAIGURI | WEST BENGAL | 735204 | L-3 | Rejected-Finance Being L-3 | |
| 4 | L-4₹38.6 L+₹4.5 L (13.0%)Rejected-Finance GOKUL APARTMENT PANJABIPARA DISTT JALPAIGURI SILIGURI 734401 WB | DARJEELING | WEST BENGAL | 734401 | L-4 | Rejected-Finance Being L-4 | |
| 5 | Rejected-Technical BLOCK B WARD NO 34 SURYASEN COLONY HARI MANDIR ROAD PO SILIGURI TOWN PS NEW JALPAIGURI DIST JALPAIGURI W B PIN 734004 | DARJEELING | WEST BENGAL | 734004 | - | Rejected-Technical Rejected due to not enlisted with appropriate category b (i). |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH BINNAGURI
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
COMPREHENSIVE MAINTENANCE TO CERTAIN BUILDING UNDER BDE HQs AND NORTH ZONE SHOPPING COMPLEX IN NORTH ZONE AND REPAIR/REPLACEMENT OF LT ELECTRICAL DISTRIBUTION SYSTEM AND ALLIED WORKS AT SOUTH ZONE UNDER GE (NORTH) BINNAGURI
2023_MES_611906_1
NIT No. 8701 / 23 / 2023-24 / 09 / E8
Open Tender
Civil Works
Item Rate
270 days
BINNAGURI CANTONMENT
Class D Category a (i) b (i)
8 documents required · 8 mandatory
₹500
GE NORTH BINNAGURI
₹90,000
Yes
20 Oct 2023
3 Aug 2023
6 Sept 2023
3 Aug 2023
4 Sept 2023
19 Aug 2023
Amount
Taking down chowkats or frames exc 1.5 sqm but n.exc 4 sqm (without taking off shutter from the frame) each and removing from the site including dismantling brick work for hold fasts etc complete all as specified and as directed.
Taking down chowkats or frames n.exc 1.5 sqm (without taking off shutter from the frame) each and removing from the site including dismantling brick work for hold fasts etc complete all as specified and as directed.
Taking down shutters of any description exc 1 Sqm and n.exc 2.00Sqm each and removing from site complete all as specified and as directed.
S&F factory made Pressed steel frames confirming to IS , having profile of size 105 x 60 mm, 1.25 mm thick MS Sheet for doors with one or more rebates including necessary supply and fixing lugs, lock strike plate, etc 100 mm size hinges, with one shop coat of zinc chromate primer and fixing complete all as specified and as directed.
M&L for PCC type C-1, 1:3:6 using 20mm graded aggregate as in bed block for fixing of hold fast, filling concrete in frame filling , gaps in between glazed & fly proof steel window, cills, railing up to 60 cm in height etc including necessary form work as required complete all as specified and as directed.
S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick plain colour printed PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and as directed.
M&L factory made solid panel PVC plain colour door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat molded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side &as gap insert for top rail & bottom rail paneling of wood grain printed PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed to gathers with solvent cement supplying & fixing the frame at site complete all as specified and as directed.
S&F of 35mm thick 2nd class hard wood factory made, plain, framed, paneled shutter (two panel) with lock rails and panel of 9mm BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces. The size of rail and style as per IS-1003 Part-I klin seasoned and chemically pressure treated complete all as specified and as directed.
S&F for factory made 35mm thick 2nd class hard wood gauged and skeleton shutter open rebated and prepared to received gauge etc (without sash bars) for fly proof door shutter, edges of framing plain, chamfered or rounded, fitted with cut of any mitered beads for securing gauge etc, size of members of shutter as specified in SSR Part-I section 8 clause No. 8.23(a) and fitted to chowkats complete all as specified and as directed.
M&L taking down and refixing of shutter of any description n.exc 1 Sqm and n.exc 2 Sqm each of same opening doing resecuring or easing & adjusting complete all as specified and as directed.
S&F aluminium (die cast body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed.
S&F of Stainless Steel butt hinges, medium weight cold rolled of size 100mm complete all as specified and as directed.
S&F 150 mm long Aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S&F 150 mm long Mild steel pressed handles, oval type, stove enameled black complete all as specified and as directed.
S&F 150 mm long MS barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S&F aluminium anodised extruded fabricated type handle 150mm long complete all as specified and as directed.
S&F aluminium alloy anodised sliding door bolt 250 mm long with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section complete all as specified and as directed.
S&F factory made pressed steel windows of standard size and section as shown on HQ CE Siliguri Zone Drg No CESZ/2018/TD-07, Sheet 1/3 to 3/3 with double shutter i.e glazed & wire gauged shutter including all fittings and fixture like MS hold fast, box hinges, handles, MS tower bolts, stoppers, MS guard bar/grill etc complete including one shop coat of zinc chrome primer complete all as specified and as directed. Notes:- (a) Rate quoted shall be deemed to be including of all fittings fixtures. (b) Glass, wire mesh, MS Guard bar/grill and painting shall be measured and paid separately under relevant items of this schedule. (c) The drawings referred above are available in the office of Engr-in-Charge and can be referred in the office working hourse if required. (d) PCC (1:3:6) type C1 to be filled in chowkats frame and paid under relevant item of schedule.
S&F factory made pressed steel windows of standard size and section as shown on HQ CE Siliguri Zone Drg No CESZ/2018/TD-07, Sheet 1/3 to 3/3 with single shutter with glazing bars including all fittings and fixture like MS hold fast, box hinges, handles, MS tower bolts, stoppers, MS stay with long screw, MS spring latch, MS guard bar/grill etc complete with glazing bars including one shop coat of zinc chrome primer complete all as specified and as directed. Notes:- (a) Rate quoted shall be deemed to be including of all fittings fixtures. (b) Glass, wire mesh, MS Guard bar/grill and painting shall be measured and paid separately under relevant items of this schedule. (c) The drawings referred above are available in the office of Engr-in-Charge and can be referred in the office working hourse if required. (d) PCC (1:3:6) type C1 to be filled in chowkats frame and paid under relevant item of schedule.
S&F steel ventilator top hung shutter including hinges, steel peg stay, fixing lugs etc complete with or without glazing bars including taking down of old steel ventilators of any size complete all as specified and as directed.
M&L for mild steel framed work such as grills, guard bars, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
M&L for Rolled mild steel in post Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc of grade Fe 410-W (Gde-E-250 quality A) complete all as specified and as directed.
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
M&L for preparation or new of previously untreated steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Hacking out old broken unserviceable glass panes (any thickness, size, quality or description) for metal frame including punching or drilling out old glazing pins/spring clips and providing & fixing new one complete all as specified and as directed.
S&F of 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane complete all as specified and as directed.
S&F 3 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 Sqm in each pane complete all as specified and as directed.
S&F for 5.5mm thick sheet glass ordinary quality and glazing in square exc. 0.5 Sqm in each pane as in aluminium door & windows including supplying and fixing of necessary aluminium cleats, rubber gaskets etc and making good complete all as specified and as directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Demolition of brickwork built in cement mortar including all quions, arches, pillars etc complete all as specified and as directed.
M&L for brick work with fly ash bricks old size straight or curved on plain exc mean radius built in cement mortar 1:6 complete all as specified and as directed.
All as item No. 33 here in before but except bricks complete all as specified and as directed.
Taking down cement plaster on wall of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for 20 mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm & 10mm) mixed with water proofing compound in top layer 200 ml per beg of cement or as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately as supply only.
M&L for rendering 5 mm thick cement plaster on ceiling surfaces with cement mortar (1:3) complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surface finished fair and even (without using extra cement) complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for preparation of newly plastered surface of wall and applying two coats of colour wash to match the colour of existing adjacent surface complete all as specified and directed.
M&L for preparation of newly ceiling plastered surfaces and applying three coats of white wash on wall as specified as directed.
M&L for preparation of new internal wall surfaces with one coat wall putty and applying two coats of distemper oil emulsion complete all as specified and as directed.
M&L for preparing of old surfaces of walls and applying one coat of distemper oil emulsion complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises including taking down cement plaster complete all as specified and as directed.
M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but n. exc. 0.18 Sqm, in floors etc. set and jointed in neat cement slurry over 15mm thick screed bed or bedding layer in CM (1:6) as in floor and pointed in white or coloured cement to match as in floor complete all as specified and as directed.
M&L for coloured non skid ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc set and jointed in neat cement slurry over 15mm thick screed bed or bedding layer in CM (1:6) as in floor and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms, corner shelf, flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 15 mm thick cement plaster (1:4) including rounding the exposed surfaces of granite complete all as specified and as directed.
M&L pre-polished and chemically treated smooth finish exterior grade coloured chequered tile of size 300 mm x 300 mm x 25mm thick, set, jointed and pointed in neat cement slurry in floors including 15mm thick screed bed or bedding layer in cement mortar (1:6) as in path complete all as specified and as directed.
M&L for coloured machine pressed precast concrete interlocking paver block (ISI marked) with grey cement and no pigment any shape and size conforming to IS 15658-2006 of 60 mm thickness M-35 Grade complete all as specified and as directed. Note: Sand cushioning shall be measured and paid separately.
M&L for fine aggregate (sand) spreading and leveling in layers n.exc 50mm thick under paver block for cushioning complete all as specified and as directed.
M&L for glazed ceramic tiles/digital elevation tile as in vertical surfaces 300 x 600 x 7mm/450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed white or colour cement to match over 10mm thick backing coat in CM 1:4 complete all as specified and as directed.
Demolition of cement concrete (un-reinforced ) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for 75mm thick PCC (1:3:6), type C-2 (using 40 mm graded crushed stone aggregate ) as in plinth protection; etc laid in bays / panels not exc. 2.00 Sqm each including construction joints at suitable interval and each corner and filled with bituminous mastic filling (1 part bitumen & 3 part sand) and finished the surface even and smooth without using extra cement complete all as specified.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 15 mm bore complete all as specified and as directed.
S&F of Tubes medium grade 15mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and as directed.
Refixing of old steel tubing and connections in new or old position (wall, ceiling, floors, etc) of 15 mm bore complete all as specified and as directed.
M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing etc., and making good, cutting not exceeding 10 cm girth in brick walls complete all as specified and as directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 20 mm bore complete all as specified and as directed.
S&F of Tubes, medium grade, 20 mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete all as specified and as directed.
Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc) complete all as specified and as directed.
Dismantling water tank exc 500 & 1000 ltr capacity and removing to store complete all as specified and as directed.
S&F of PVC water storage tank 500 ltr capacity HDPE double layered, cylindrical type fixed and hoisted in position on roof at any height complete with inlet/outlet of 20 mm GI Pipe connection including locking arrangement, including supplying & fixing of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm dia and (Minimum weight 20 mm - 210 gms). Note:- GI inlet, outlet & wash out pipe will be measured paid for separately.
S&F of PVC water storage tank 1000 ltr capacity HDPE double layered, cylindrical type fixed and hoisted in position on roof at any height complete with inlet/outlet of 20 mm GI Pipe connection including locking arrangement, including supplying & fixing of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20 mm dia and (Minimum weight 20 mm - 210 gms ). Note:- GI inlet, outlet & wash out pipe will be measured paid for separately.
S&F in repairs 15 mm dia Bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F in repair concealed stop cock CP, cast copper alloy fancy type for 15mm pipe complete all as specified and as directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
S&F in repair 15mm bore Stop cock of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 90gms) complete all as specified and as directed.
S&F in repairs of swivel shower of PTMT any coloured for fixing with 15mm pipe (Minimum weight 40 gms) complete all as specified and as directed.
S&F in repairs Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size including CP waste coupling, PVC connection 450 mm long, waste pipe & removing the existing Basin, cutting for and pinning ends of brackets or erecting stand complete all as specified and as directed.
S&F in repairs 15 mm bore pillar taps, capstan head, screwed down high pressure with or without lettered ‘HOT’ or ‘COLD’ long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F vitreous china squatting pan "Orissa" pattern size 580x440mm white with integral foot rests(excluding flushing cistern and flush pipe) with 'P' or 'S" trap from or back inlet etc including connection to trap tand flushing pipe and provision of cement concrete bedding complete all as specified and as directed in repairs including demolition of existing one.
S&F in repairs vitreous china wash down water closet pedestal pattern white excluding fixing bolts, flushing cistern and flush pipe complete but including PVC seat cover with aluminium/PVC hinging devices & EWC Jet chromium plated with 1.00 mtr long PVC connection pipe etc complete all as specified and as directed.
S&F in repairs PVC low level flushing cistern 10 ltr capacity sleek including PVC bend, supporting brackets with accessories white colour complete all as specified and as directed.
S&F in repair Vitreous China Urinal, Half stall type, white with flush pipe, connecting pipe & waste pipe, CP urinal spreader complete all as specified and as directed.
S&F in repair Vitreous China Urinal partition white of size 310 x 700 mm complete all as specified and as directed.
S&F in repair 15 mm dia brass chromium plated angle cock with flange complete all as specified and as directed.
S&F grating doom 125mm dia with waste hole of PTMT (min wt 40 gms) complete all as specified and as directed.
Taking down PVC/AC pipe of any dia & any description including all fittings complete all as specified and as directed.
S&F 110 mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall or laid in floors complete all as specified.
S&F 75 mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall or laid in floors complete all as specified and as directed.
S&F 110mm dia PVC SWR bends of any radius with out access door complete all as specified and as directed
S&F 110mm dia PVC (SWR) junction single 'T' equal or unequal with access door complete all as specified and as directed.
S&F 110mm dia PVC (SWR) branch piece, single ‘Y‘ equal or unequal complete all as specified and as directed.
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for RCC type B1 (1:2:4) using 20 mm graded stone aggregate as in fins, fascias, louvres, parapets, chajja/sunshade, shelves and railings, newels, balustrade & the like complete all as specified and as directed.
Formwork to fins, fascias, louvres, parapets, chajja/sunshade, shelves and railings , newels, balustrade & the like for fair finished surfaces of concrete flat complete all as specified and as directed.
M&L for mild steel TMT bars 6mm to 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and as directed.
Taking down tar felt with cement plaster from roof surfaces and lowering and removing the same to a distance exc. 50m and n. exc. 100m including roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed.
M&L for 10mm thick screed bed or bedding layer in cement mortar (1:4) mixed with WPC in order to maintain proper slope over existing roof surfaces for laying water proof treatment finished even and smooth without using extra cement complete all as specified and as directed. Note: WPC will be measured and paid separately.
M&L for providing, cement concrete type B1 1:2:4 using 20 mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges, padding to roof etc complete all as specified and as directed.
M&L for waterproofing Coating with polyurethane based water proofing liquid membrane of approved make to be applied by brush with multi coats with minimum dry film thickness of 1mm and shall be cured by reaction with atmospheric moisture to give a tough elastomeric waterproof membrane complete all as specified and as directed. Note:- The above treatment will be carried out by authorised applicator of approved firm/company.
S&F Powder coated aluminium window sliding type three track (2 glazed & one gauze shutter) aluminium sections weighing not less than 1.67kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazing cleats, rubber packing, screws, handle, locking arrangement and 5.5mm thick plain/tinted glass and aluminium mosquito proof gauge including taking down of old existing steel window and making good disturbed surface of wall complete all as specified and as directed.
S&F powder coated anodized aluminium door made out hollow extruded aluminium sections as mentioned below. Each door having 02 Nos disk or D type handles of 200mm long, 02 Nos aluminium tower bolt of 200mm size, 1 no mortice lock of six levers with key in duplicate regulated by double action hydraulic floor door spring (Make Sandhu /Titz or equivalent as approved by the GE) shutter to be paterly glazed with 5mm thick tinned glass and partly paneled with 12mm thick prelaminated particle board fixed with glazing clips rubber beading /gasket anodized aluminium beading screws complete including taking down old unserviceable shutter with frame complete all as specified and as directed. (a) Chowkat frame : 100 x44 x1.60 mm (b) Shutter vertical style : 100 x44 x1.60 mm (c) Shutter lock rail : 150 x44 x1.60 mm (d) Shutter Top rail : 100 x44 x1.60 mm (e) Shutter bottom rail : 200 x44 x1.60 mm
M&L for preparation of old decorative surface of wall and applying two coats of colour/white wash to match the colour of existing surface complete all as specified and as directed.
M&L for washing, rubbing down and scraping of old decorated surface and preparation of old ceiling plastered surfaces for applying one coat of white wash complete all as specified and as directed.
M&L for washing, rubbing down and scraping of old decorated surface and preparation of old wall plastered surfaces for applying one coat of white/colour wash on wall complete all as specified and as directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
S&F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof/to wall/ridges fixed with self tapping screws complete all as specified and as directed.
S&F in repair CP health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook in including making connections and fixed in position complete all as specified and as directed.
S&F for brass chromium plated fancy type towel rail 600 mm long complete all as specified and as directed.
INTERNAL ELECTRIFICATION Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten/ conduit/ gutties/ wooden boards/ switches/ sockets/ regulators/ light fittings etc and separating the serviceable items like fan regulators and light fittings for re-use under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and as directed.
M&L for concealed conduit point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including PVC conduit of adequate size with all accessories (including cutting chases & making good the disturbed surface to its original specification) including MS sunk box, 3mm thick hylum sheet top cover fixed by means of brass machine screw and cap washer including size 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches/DB's or common earth dolly for one light point controlled by one, one way switch complete all as specified and directed.
All as per item No 104 here in before but for one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and as directed.
All as per item No 104 here in before but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and as directed.
All as per item No 104 here in before but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and as directed.
All as per item No 104 here in before but for light point controlled by two way switch Amps complete all as specified and as directed.
All as per item No 104 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
S&F switch piano single pole flush type 5 amps, 230 volts one way complete all as specified and as directed.
S&F switch piano single pole flush type 5 amps, 230 volts two way complete all as specified and as directed.
S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and as directed.
S&F socket 2 in 1, 5 Pin, 5/15 amps, white ivory finish flash type complete all as specified and as directed.
S&F switch piano single pole flush type 15 amps, 230 volts one way complete all as specified and as directed.
S&F Switch socket combination 2 in 1 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish with complete all as specified and as directed.
S&F switch socket combination 2 in 1 multipurpose 3/5 pin 5/15 amps flush type complete all as specified and as directed.
S&F in repair ceiling rose, Bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed.
S&F in repair lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and as directed.
S&F LED white glass Lamp 1x9 Watt 230V Base-22 complete all as specified and as directed.
S&F in deluxe fan Electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 130 mm x 180 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 120 mm x 170 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 230 mm x 280 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour round type of size 80 mm dia including taking down existing unserviceable complete all as specified and as directed.
S&F IP 20, Class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and as directed.
S&F Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete including removal of old unsv fitting complete all as specified and as directed.
S&F IP 20, Class I, LED Mirror light fitting 1 x 9 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified and as directed.
S&F Recess round shape LED ceiling light 12 Watt fitting (6'' outer dia) for armstrong/ grid ceiling, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness SMD LEDs etc complete with all accessories internally prewired and necessary mounting arrangements, including necessary connection and taking down old one complete all as specified and as directed.
S&F Post top lanterns 15 watt LED light fitting ,new generation, energy saving, environmental friendly, long life with symmetrical light distribution, spun aluminium landscape luminaries with high power LEDs as light source, spun aluminium canopy, with opal/clear acrylic diffuser and complete with all accessories internally prewired including connecting up with three core twisted flexible copper conductor cable up to ceiling rose and necessary mounting arrangements and taking down old one complete all as specified and as directed.
S&F Recess mounting flat panel 34 Watt LED fitting (2'X2') for grid of false ceiling, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness SMD LEDs etc complete with all accessories internally prewired and necessary mounting arrangements, including necessary connection and taking down old one complete all as specified and as directed.
S&F of Bulk head luminaire with B22 base holder suitable for 9 Watt LED inverter type bulb light IP66 grade, with and including 9 watt LED (or nearest next higher wattage) lamp (LED Bulb with B22 base 900 Lumens in normal mode and 450 lumens in power back up mode, charging time 8-10 Hrs and around 4 Hrs Power backup with inbuilt surge protection of 3 KV) (or nearest next higher wattage) and connecting up with and including PVC insulated 3 core of size 0.75 Sqmm copper conductor from ceiling rose to terminal block of light fitting including necessary taking down the old unserviceable fitting complete all as specified and as directed.
M&L for sub main wiring with 2 run of 6.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 6.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in 25mm dia PVC rigid non- metallic concealed conduit with and including taking down unsv sub main, complete all as specified and as directed. Note : Two runs of sub main wiring cable along with one run of earth wire with and including PVC conduit pipe shall be measured as one unit length.
M&L for sheet metal enclosure fabricated out of 2.0 mm thick CRCA sheet, totally enclosed type, dust & vermin proof, with suitable sized supporting MS angles & suitable openings at top & bottom for entry of outgoing / incoming cables, fixed with nuts & bolts & front side openable with hinged shutter with suitable locking arrangement duly painted with 2 coats of powder coated paint over a coat of red oxide primer (spray paint) with minimum dimensions (90 x 75 x 20 cm ) flush to wall for incorporating 01 No TPN DB, 04 Nos electronic meters etc including taking down old one complete all as specified and as directed.
S&F sheet metal enclosure MCB DB TPN 4 way with 200 amps rated bus bar 415 volts double door with magnetic locking system complete including removal of old unsv sheet metal enclosure complete all as specified and as directed.
S&F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 8 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, earth link earthling studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface including removal of old unsv sheet metal enclosure complete all as specified and as directed.
S&F MCB, Triple pole & neutral 63 amps, 240 volts, ‘C’ curve, 10KA including taking down old one complete all as specified and as directed.
S&F MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one as specified and as directed.
S&F MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete with and including taking down old unsv one as specified and as directed.
S&F Single pole and neautral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 240 Volts, including necessary connection complete all as specified including taking down old one.
EXTERNAL ELECTRIFICATION Taking out old unserviceable cable of any size carefully from trenches ofter disconnecting electric connection, GI pipe protection, with and including separating serviceable bricks & set aside and removing un-serviceable bricks from site complete all as specified and as directed. Note : The Excavation and earth work shall be measured and paid separately under relevant item of Schedule.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 2 core with and including all fixing & connecting accessories such as Aluminum cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. Note: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A'.
All as per ser item No 141 above but of cross sectional area 16 sqmm 4 core complete all as specified and as directed.
All as per ser item No 141 above but of cross sectional area 25 sqmm 4 core complete all as specified and as directed.
All as per ser item No 141 above but of cross sectional area 35 sqmm 3.5 core complete all as specified and as directed.
All as per ser item No 141 above but of cross sectional area 50 sqmm 3.5 core complete all as specified and as directed.
All as per ser item No 141 above but of cross sectional area 120 sqmm 3.5 core complete all as specified and as directed.
All as per ser item No 141 above but of cross sectional area 240 sqmm 3.5 core complete all as specified and as directed.
Digging out incoming and outgoing cables of any sizes from loops near junction box/ feeder pillar box in trenches, cutting burnt out uninsulated portion of cable and relaying /refixing in trenches & returning, refilling the excavated soil and connecting the cables with bus bars including provision of suitable size of aluminium lugs complete all as specified and as directed.
Relaying in trenches or passing through pipe, 1100 volts grade, LT electric power UG cables, of any type/Size with and including all fixing & connecting accessories such as Aluminum cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. Note; Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A'.
S&F of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 63 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
S&F of moulded case circuit breaker (MCCB) four pole Microprocessor release type 415 volt, 50 Cycles, 100 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
S&F of moulded case circuit breaker (MCCB) four pole Microprocessor release 415 volt, 50 Cycles, 160 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
S&F of moulded case circuit breaker (MCCB) four pole Microprocessor release type 415 volt, 50 Cycles, 200 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
S&F of moulded case circuit breaker (MCCB) four pole Microprocessor release type 415 volt, 50 Cycles, 250 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
S&F of moulded case circuit breaker (MCCB) four pole Microprocessor release type 415 volt, 50 Cycles, 400 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
S&F in replacement MCB, Triple pole & neutral 63 Amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed.
M&L for Heat shrinakable straight through joint for 3.5 / 4 core cable 25 Sqmm to 50 Sqmm complete all as specified and as directed.
M&L for Heat shrinakable straight through joint for 3.5 / 4 core cable 70 Sqmm to 120 Sqmm complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exc. 1.5 meter wide and not exc. 1.5 meter in depth and getting out for taking up / laying under ground electric cable complete all as specified and as directed.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cms in depth complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed.
Supply and laying sub class B bricks of size 25cmx12.5cmx7.5cm (+/-10% tolerance) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed.
Laying only Old bricks for protection of LT UG cable complete all as specified and as directed. Note: The serviceable bricks obtained from dismantling taking down shall be reused.
M&L for horizontal boring across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed. Notes:- (a) Removal of surplus soil shall be deemed to be include in the unit Rate. (b) GI pipe will be measured and paid separately under relevant item of Sch 'A'.
M&L for 50 mm bore steel tubing light grade for protection of cable including necessary joints complete all as specified and as directed.
M&L 80 mm bore steel tubing light grade for protection of cable including necessary joints complete all as specified and as directed.
S&F aluminium bus bar of size 400 mm X 40 mm X 6mm wrapped with PVC sleeves with maintaining the colour code and provision of holes as required with nuts, bolts & washers for cable connections including hydrographic insulators with nuts & bolts at both ends including taking out old unserviceable bus bar complete all as specified and as directed.
S&F aluminium bus bar of size 600 mm X 20 mm X 6mm wrapped with PVC sleeves with maintaining the colour code and provision of holes as required with nuts, bolts & washers for cable connections including hydrographic insulators with nuts & bolts at both ends including taking out old unserviceable bus bar complete all as specified and as directed.
Dismantling of old unserviceable LT feeder pillar box/LT junction box including foundation after disconnecting of all electrical connection complete all as specified and as directed.
Supply, fabrication, installation and testing of LT out door type factory made, junction box of size 900mmX600mmX400mm (over all dimension) made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 25X25X5mm vertical frame and legs with mild steel flat iron 25X5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrangement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of size 0.80m X 0.6m X 0.90m depth (0.30m below ground level and 0.60m above ground level ) and connections of all outgoing / incoming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories complete all as specified and as directed. (a) Copper bus bar of size 600 Amp wrapped with PVC sleeves with maintained the colour code and provision of making holes as required with nuts, bolts & washers for cable connections including hydrographic insulators with nuts & bolts at both ends = 04 nos. (b) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
Supply, fabrication, installation, testing and commissioning of LT 3 Phase 4 wire 450 Volts system, factory made water and vermin proof protection pedestal type feeder pillar box of minimum size 1200 mm x 800 mm x 500 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation arrangement including provision of cable looping box of size 800 x 450 x 400 mm . Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The panel shall be complete painted with Powder Coated paint of approved shade. "U" type gas ket shall be used to make the inner shell completely vermin proof to accommodate incomers/outgoing MCCBs. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN coppe bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size "F" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shall be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.80 m x 0.60 m x 1.05 m depth (45 cm below ground level and 60 cm above ground level) as in foundation in cement mortar 1:6 and plastering the same in cement mortar 1 : 6 finished even and smooth with out using extra cement complete including necessary excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in trenches complete all as specified and as directed along with and including comprising of the following accessories : - Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) the schematic dig of LT panels shall be approved by GE before procurement. (a) Incoming Copper bulbar 600 Amps capacity including insulator with nuts & bolts-04 Nos. (b) Outgoing Copper bulbar 400 Amps capacity including insulator with nuts & bolts-04 Nos. (c) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ices=100% Ice, neutral adjustment 100% of rating 250 amps including all fixing accessories with both ends spreader links (Incoming -01 Nos). (d) Enameled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door/shutter of FPB for LT -01 No.
M&L for preparation of the old decorated existing external steel surface of feeder pillar boxes/LT panels /JBs of any size and description in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopping required and applying two coats of Asian aspa paint (Mahindra Grade) by using spray painting machine on old prepared surface including marking of Sub Stn No, Feeder No and feeding area/Bldg with applying synthetic enamel paint (1st grade) complete all as specified and as directed.
S&F in repairs LED indicating RED lamp, including necessary connection complete all as specified and as directed.
S&F in repairs LED indicating YELLOW lamp, including necessary connection complete all as specified and as directed.
S&F in repairs LED indicating BLUE lamp, including necessary connection complete all as specified and as directed.
S&F in repairs CT coil 100/5 Amps including necessary connection complete all as specified and as directed.
S&F in repairs danger notice board / plate of size 20 cm x 15 cm, made out of 1.6 mm thickness mild sheet, vitreous enameled white letters, figure and conventional skull and bones in Red colour and fixed with nuts and bolts for 1100 volts current complete all as specified and as directed.
Cutting unaxious green growth and wild grass by manual labour or by machine at Electrical Installation Premises around pole, around panel board along boundaries fencing, removing runnish material from work site and depositing where directed not exc. 100 meter from the starting point complete all as specified and as directed. Note: The item shall be operated maximum 2 (Two) times in the entire period of the Contract period and measurement will be taken every time independently for payment.
S&F aluminium strip of size 25x3.15 mm for earth continuity conductor fixed on PCC block complete all as specified as directed complete all as specified and as directed.
S&F copper strip of size 20x3.15 mm for earth continuity conductor fixed on PCC block complete all as specified as directed complete all as specified and as directed.
Dismantling of existing unserviceable loose/disturbed aluminum strip/GI Strip/Termination rod of any sizes on roof/down conductor fixed on wooden guities /directly on roof including screws etc complete all as specified and as directed.
S&F in repairs for 32 x 6 mm galvanised iron strip, earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or fixed to poles or roof with saddle and screw current complete all as specified and as directed.
S&F porcelain insulator of size 65x31 mm and height 30mm with three nos hole including GI bolts and nuts of required size and two nos washer on PCC, fixing strip complete all as specified and as directed.
S&F air termination single pointed aluminium rod 12mm dia and 300 mm height complete all as specified and as directed.
M&L for PCC work by providing PCC type B2 (1 : 2 : 4) with 20 mm graded stone aggregate in foundation for panel and finishing the surface even and smooth without using extra cement including breaking of old PCC complete all as specified and as directed.
Disconnecting electric connection and Taking down of all UG cable from LT Panel/JB of any capacity and model removing of unserviceable spares / accessories for repair/replacement of the same including reconnection of all UG Cable connection with suitable lugs ,nuts & bolts etc. to existing LT Panel/JB and testing complete all as directed. The unit Rate shall be deemed to be included for the following nature of work:- (i) Contractor shall provide one Electrician and two helper along with tools. (ii) Spares/Parts for repair will be measured and paid separately as supply only under relevant item of this schedule.
M&L for Earthing complete with Copper earth plate electrode 600x600x3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to Copper earth strip 20x3 mm dia by means of bolts, nuts, check nuts and washers of brass/copper all as shown in electrical plate No 3 of SSR Part-I 2009 connected to lightening conductor all as specified and testing on completion including. Necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade, for protection of earth strip complete all as specified and directed. Note: Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate complete all as specified and as directed.
M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or of steel all as shown in electrical plate No 3 of SSR part-I 2009 connected to pole/LT Panel all as specified and testing on completion including. Necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade, for protection of earth strip complete all as specified and directed. Note: Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate complete all as specified and as directed.
M/S SINHA ENTERPRISE
S.N. GHOSH AND CO.
ANIL ENGINEERING CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .