Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-AOC 354 SIRAJ MONDAL ROAD KANCHRAPARA 24 PGS N | KANCHRAPARA | NORTH 24 PARGANAS | WEST BENGAL | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.7 L+₹815 (0.12%)Rejected-Finance 2 NO SIDDHESWARI LANE KANCHRAPARA 24 PARGANAS N WEST BENGAL 743145 | KANCHRAPARA | NORTH 24 PARGANAS | WEST BENGAL | 743145 | L2 | Rejected-Finance Being L2 Bidder. | |
| 3 | L3₹6.9 L+₹22,498.97 (3.36%)Rejected-Finance 000 RATH TALA UKHRA UKHRA UKHRA BARDHAMAN WEST BENGAL 713363 | PASCHIM BARDHAMAN | WEST BENGAL | 713363 | L3 | Rejected-Finance Being L3 Bidder. | |
| 4 | L4₹7.4 L+₹66,802 (9.96%)Rejected-Finance 139 3 A PO KHAGRA DIST MURSHIDABAD PIN 742103 | KHAGRA | MURSHIDABAD | WEST BENGAL | 742103 | L4 | Rejected-Finance Being L4 Bidder. | |
| 5 | L5₹7.5 L+₹82,295 (12.3%)Rejected-Finance 1260 GANGAPUR GROUND FLOOR MANDIRTALA DUTTAPUKUR NORTH 24 PARGANAS WEST BENGAL 743248 | 24 PARAGANAS NORTH | WEST BENGAL | 743248 | L5 | Rejected-Finance Being L5 Bidder. |
Tender Value
Refer Docs
EMD Value
₹15,847
Closing Date
1 Aug 2022, 11:00 amClosed
EXECUTIVE ENGINEER, P.W.D, N 24 Prg El Divn.
TOP FLOOR, MECHANICAL COMPLEX, BAGUIATI, KOLKATA 700 059
Replacement of old, damaged SV fittings by LED Street light and fixing of tube and fan fittings at RMSA building with other works at Govt. Basic- cum -Multipurpose School, North 24 Parganas, Project ID-ES212250746S000.
2022_WBPWD_390582_1
WBPWD/EE/N24PRG/ELEC/NIT- 08/22-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Banipur
Please refer Tender documents.
5 documents required · 5 mandatory
₹15,847
TOP FLOOR, MECHANICAL COMPLEX,BAGUIATI, KOL-59
27 Dec 2022
18 Jul 2022
3 Aug 2022
18 Jul 2022
1 Aug 2022
26 Jul 2022
25 Jul 2022
Amount
Laying and Jointing PVC Pipe. Heading
Supply of PVC/A AI. Cable (Make-KEI/Gloster/Havells/Polycab/RR) i) 2 core 6 sq.mm. (for existing SPNDB connection in new RMSA building , Auditorium metal, & Comopund Light ).
Laying of cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. i) 2 core 6 sq.mm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of said XLPE/PVC armoured cables. i) 2 core 6 sq.mm
Finishing the end of following PVC armoured cables by crimping method incl. supplying and fixing solderless socket(Dowels make), tapes, anticorrosive paste & jointing materials :(2nos-SPNDB, 12 nos- compound light Loop box) i) 2 core 6 sq.mm
Supply and fixing of 24 hrs digital timer in the existing timer DB with necessary connection and repairing work.(for existing main building timer DB)
SITC of 250V Timer DB in 8 way SPNDB concelaed in wall of size double door sheet metal enclosure with neutral bar DIN rail with 1no. 20/25 A DPMCB, 1 No. 24 hrs programmable digital timer switch and 1no 18/25 AQ contractor (L&T) single phase motor starter (compact 25A min) complete with internal wiring with suitable size of copper wire incl. 1no auto manual bypass change over switch and provision for e/a. incl. LED indicating light with locking arrangement as per direction of EIC(compound light control in RMSA Building from existing PBDB) (Make-Legrand/Crabtree/L&T/Hagar)
Supplying and Fixing of (250x250x100)mm GI water proof looping cable box havinghinged GI Top Cover having 4 mm thick with rubber gasketlining, railway type mechanical locking arrangement, earthingterminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL onporcelain insulator etc. (4nos for RMSA Building 3 nos for Auditorium)
Supply and Drawing 2x2.5 sqmm + 1x1.5 Sqmm single core standard FR PVC insulated and unsheathed copper wire in 19 mm bore 3mm thick polythene pipe through pole as per GS (for compound light connection from loop box.)
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make-Havells/Finolex/Polycab/RR/KEI/Gloster) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm)
S & F of street light luminaries 72 watt LED fitting (make: philips/Crompton/Bajaj/Havells/Wipro) ,model- Bajaj ZELA P 86L WH PO TG SD/Equivalent ) complete with all accessories in existing compound light pole. .
Supply & fixing of outdoor flood LED luminaries 80 W outdoor fittings (Make: philips/Crompton/Bajaj/Havells/Wipro) Cat No-Bajaj Praze F 96L WH NB-A5 TG SD/Equivalent) complete with all accessories as required for Compound Illumination from the parapet with the help of fastner arrangement.
S & Fixing of 18W single LED poly carbonate Tube light fitting(Make-make: philips/Crompton/Bajaj/Havells/Wipro) with 1 no LED tube lamp( Model-BLRB-DB 118 & BLRB 18W CW LED/Equivalent) by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 2 mt. length with 1.5 ft downrod in the RMSA building .
S & Fixing of 18W twin LED poly carbonate Tube light fitting(Make- philips/Crompton/Bajaj/Havells/Wipro) with 2 no LED tube lamp( Model-BLRB-DB 218 & BLRB 18W CW LED/Equivalent) by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 2 mt. length in the existing downrod in the Auditorium.
Supply & Fixing of 1200mm, 240V AC ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. (make:- CG High speed/Usha Stricker Galaxy/Orient Quasar Ornamental)
S & Fixing of 12W LED lamp in existing batten point in toilet & entrance gate. (Make- philips/Crompton/Bajaj/Havells/Wipro).
S & F of 9” sweep AC Exhaust fan on wall with nuts & bolts as required with louver shutter as per GS (Make EPC Heavy duty/Bajaj/Crompton)
S & Fixing of 120W LED flood light fittings in Auditorium with proper fixing arrangement with angle iron frame from the ceiling .(Make: Make- philips/Crompton/Bajaj/Havells/Wipro) model-Bajaj Praze F 144L WH NB-A5 TG SD/equivalent) (For Auditorium)
Disconnecting and lowering the above said existing tube fittings & fan fittings as per direction of EIC.
Supply of 20 ft Al bi folding good quality (Make-as per direction of EIC) ladder to change the light & fan fittings for Auditorium building maintenance work
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe.
Glow Signage
SITC of LED illumination sign board fabricated by 18’ (ft)×4.5’ (ft) × 5 (inch) depth ACP box supported with 1.5'’×1.5'’ MS hollow square pipe as per design approved by EIC with 18 swg all around. The 3 mm ACP facial should be provided with Laser cutting 6 mm thick acrylic letters out of which 3 mm rising from the surface of the ACP board. 6 mm letters should be fixed on another 3 mm acrylic sheet on back side of the ACP facial. Border line of the front portion and back portion should be covered by 1.5” SS channel as per the direction of EIC. The sign board should be glow from back side of letters by 1.5W/2.0 LED 2/ 3 / 4 module cool white in colour including 12V 750W power supply and LED must be covered in box made of 3 mm thick sun board. 4” with part of the four side of board should be covered by ACP after bending excess part from front side. Back side of the board also should be covered by aforesaid ACP board. The sign board should be fixed on existing position of the premises with suitable supporting arrangement on existing frame by required 40x40x5 mm angle iron frame with cross and radial support with suitable three nos cross angle support weldded with 4 nos angle hook in equal space for fixing on the structure with all necessary welding & fabrication and mending good damages as per direction of EIC. The structure shall rest in both sides with proper angle iron structure of 4.5 ft height as per direction of EIC. Colour of APC & letter will be as per direction of EIC. The cost of transportation and scaffolding charges are included. The sign board should be as per the following inscription as per direction of EIC – Probably to be provided (I) national emblem or State logo. etc. beside these the probable (actual as per authority approval) matter would be as follows:- national emblem--10x10 inch. Government of West Bengal----10" each Govt. Basic-Cum-Multipurpose School---12'' each Banipur, North 24 Parganas, Pin- 743233, ESTD-1948 ----8'' each
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (approved make) in 20mm size PVC rigid conduit 'FR' (Precision make) on wall incl. necy. fittings as required necy. fittings as per GS as required :-(Finolex/polycab/mescab/Polycab/RR/Gloster) i) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC).
II) 2 x 1.5 sqmm + 1 x 1.5 sqmm ECC
Supplying and Fixing of (250x250x100)mm GI water proof looping cable box havinghinged GI Top Cover having 4 mm thick with rubber gasketlining, railway type mechanical locking arrangement, earthingterminal with lug etc. of the following sizes as indicated below,Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL onporcelain insulator etc.
Supply and delivery of high speed 400 mm full metal body Pedestal fan (Make: Crompton/EPC Heavy duty/ Orient) (Model- Crompton PF Sstrom 2/Equivalent )
SUNLIGHT CONSTRUCTION
MAA TARA ENTERPRISE
SUBRATA GHOSH
S D ENTERPRISE
TECHNO FAITH
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .