| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC L1 HENCE AWARDED |
| 2 | L2₹1.4 Cr+₹3.0 L (2.15%)Rejected-Finance | ₹1.4 Cr+₹3.0 L (2.15%) | L2 | Rejected-Finance REJECTED |
| 3 | L3₹1.5 Cr+₹6.9 L (4.91%)Rejected-Finance 2 SHANTI NAGAR SECTOR 3 HIRAN MARGI UDAIPUR 313002 | UDAIPUR | UDAIPUR | RAJASTHAN | 313002 | ₹1.5 Cr+₹6.9 L (4.91%) | L3 | Rejected-Finance REJECTED |
| 4 | L4₹1.5 Cr+₹12.7 L (9.09%)Rejected-Finance | ₹1.5 Cr+₹12.7 L (9.09%) | L4 | Rejected-Finance REJECTED |
| 5 | L5₹1.7 Cr+₹26.2 L (18.8%)Rejected-Finance | ₹1.7 Cr+₹26.2 L (18.8%) | L5 | Rejected-Finance REJECTED |
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
23 Sept 2019, 6:00 pmClosed
AGM EE
Asst. General Manager (Engg-Elect), AAI, Trichy Airport.
Construction of 10 nos Parking bays, One Isolation bay and GSE area including taxi tracks at Trichy Airport. SH Electrical works
2019_AAI_31682_1
CMP-01/TRY/19-20
Open Tender
Electrical Works
Works
120 days
Trichy
As per NIT
9 documents required · 9 mandatory
₹1,180
AAI
₹3.2 L
29 Jun 2021
11 Sept 2019
27 Sept 2019
11 Sept 2019
23 Sept 2019
12 Sept 2019
11 Sept 2019 - 12 Sept 2019
Amount
Supply of 1X6 Sqmm, 5 KV grade single core, stranded copper conductor PVC insulated and PVC sheathed unarmoured underground Airfield Lighting Cable generally confirming to IS 1554 Part II with upto date amendments as required. (Make: As per AAI list of approved makes)
Supply of following sizes of XLPE insulated & PVC sheathed, armoured, aluminium conductor under ground cable of 1.1KV grade as per IS 7098:1988 Part-I with upto date amendments complete as required. (Make: As per AAI list of approved makes)
3.0 Core X 25 Sqmm
4.0 Core X 25 Sq.mm
Supply of Elevated Omni-directional , Medium Intensity Light Fittings suitable for Taxiway Edge Lighting use with LED complete with all accessories, breakable coupling, gaskets, two pin secondary leads, base plate with 6 nos M-10 stainless steel bolts, spring washers and other accessories with Omni directional blue lens, LED lamp and other accessories etc. complete as required meetng the requirement of ICAO Annex-14 and Aerodrome Design Manual Part-IV. (Make: As per AAI list of approved makes)
Supply of 115-120W LED Floodlight luminaire with IP66 protection , secondary lens for optimised light distribution and mounting arrangement etc complete as required.(Make: Havells Model No. JETAIRISFLS120WLED757SYMLTG / Make: Bajaj Model No. BJFL 120W LED I, Make: Philips Model. BVP122 LED 115 CW HE NB FG XTFCL S4 or its equivallent as per AAI technical Specifications))
Supply of following 5 KV grade 50 Hz series type isolating transformers, encapsulated in polyester resin, finally moulded with neoprene type rubber with primary and secondary connections meeting ICAO requirement as per IS/IEC etc. complete as required. (Secondary lead should be suitable for plug in connection to the secondary lead of the fittings offered) (Make: As per AAI list of approved makes)
15W 6.6A/6.6A Isolating Transformers
100W 6.6A/6.6A Isolating Transformers
200W 6.6A/6.6A Isolating Transformers (for Taxiway Circuits)
Supply of 6 sqmm 5 KV grade plug and receptacle of type I class B connector, suitable for field attachment with 5 KV grade PVC insulated PVC sheathed single core copper conductor cable of following size as required and confirming to the relevant IS meeting ICAO requirement. (Make: As per AAI list of approved makes)
Supply of following capacity indoor type air cooled Constant Current Regulator of Thyristor control electronic type, suitable for use on Input supply voltage as mentioned below, 50Hz, output power with tapping and output current as details below with 5 steps current variation suitable for local and remote control operation with 24V/48VDC control supply with complete digital output ammeter (0-30 or 0-10Amps) over current, open circuit, earth fault protections, earth leakage Meter & positive back indication equipments with complete 5kV grade current transformer 20/10/1Amps and relay contacts as required and as per AAI specification. (Make: As per AAI list of approved makes)
4KW, 6.6/6.6Amps, 240V AC CCR
7.5KW, 6.6/6.6Amps, 240V AC CCR
ITC of following capacity indoor type air cooled Constant Current Regulator of Thyristor control electronic type CCR.
4KW, 6.6/6.6Amps, 240V AC CCR
7.5KW, 6.6/6.6Amps, 240V AC CCR
Supply of Slim Type Edge lit guidance sign boards having various sizes (as per ICAO standard) made of reinforced 2mm thick anodized aluminium profile with suitable angle support with 1.5mm thick aluminum back cover. Signage sheet shall be 2mm thick, long life imported onon-specular surface polycarbonate and the letters & symbols made out form 3M film pasted from inside with required. coloring for mandatory / information guidance sign. Suitable solid state circuit and mechanism shall be made to function of CCR circuits. Suitable arrangment shall be made for IP 67 water proof protection. Sign boards shall be informly internally illuminated with IP 67 grade LEDs and 4mm thick light guide panels to achieve required even illumination level, operated on input sources of 2.5Amps to 6.6Amps constant current its supporting frangible legs, base frame etc., complete as per latest ICAO/FAA requirment specification.
Installation, testing and commissioning of operational guidance /mandatory signages of various sizes at various location at operational area of Airport. The signages should be installed in 1:2:4 grade cement concrete of 400X400X500mm (for legs) and a total base of 150mm thick which extends all around the board with the distance of 1500mm (front, back and both sides). The concrete base and leg foundation should be on the same level and 20-25mm above the ground level etc., complete as required as per the Annexure 14.
Supplying and laying of 50 mm Dia (outer dia) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 5 KV/1.1KV grade of Upto 35 Sqmm in the existing RCC/HUME/STONE WARE/METAL/DWC-HDPE pipe as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV/5 KVgrade of Upto 35 Sqmm in the existing masonry open duct as required
Laying and fixing of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of Upto 35 sq. mm (clamped with 1mm thick saddle) on cable tray as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (Make: As per AAI list of approved makes)
3.0 X 25 Sqmm (25mm)
4.0 X 25 Sqmm (28mm)
Making field connections by crimping plug and receptacle type essna connectors for 6/16 sqmm core copper conductor cable of 5 KV grade including applying corrosion inhibiting compound (crimping paste), PVC taping and water seal taping etc., complete as required.
Installation, testing and commissioning of elevated type MIRL on the existing transformer housing boxes including, installation of transformers, lens, filters, lamps and other accessories alignment, levelling and making secondary lead connections to transformer & fittings earth connections etc. complete as required.
Excavation of the cable trenches in hard rock not exceeding 1.5 mtr in width, and lift upto 1.5mtr, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50mtrs.
Supply and fixing of outdoor type weather proof, vermin proof, sintex junction box of size 350 X 250 X 150mm (outer dimension) generally confirming to IP-55 alongwith GI pipe, anchor bolts, frangible coupling, including civil works (foundation), grouting, sign writing and painting etc. complete as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub main wiring/ cable as required.
Supply, Installation of 1mtr GI pole of 40mm dia with the Frangible legs on concrete base with suitable bolts etc., as required and mounting arrangements for the installation of 100W-120W LED flood light for the isolation bay including supply and installation of out door type weather proof sintex box IP 55 of size outer dimension 280X180X60mm with 6Amps, SP MCB, and 20Amps 4way connector.
Modification of existing ALCMS for incorporating the additional apron flood light controls and additional CCR's etc., complete as required
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 4.0 Core X 25 Sq.mm of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required (Make: As per AAI list of approved makes)
Provision of 150 mm dia. horizontal bore well for Taxi roads crossing job including provision of HDPE heavy duty pipe along with accessories in entire bore well hole etc., suitable for cable laying complete as required.
CHENNAI ENGINEERING SERVICES
MPC ELECTRICALS AND ENGINEERS
Shantha ELectricals and Engineers Pvt Ltd
KR POWER INFRA INDIA PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .