| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.3 LAdmitted-Finance | +0.00% | ₹7.3 L | L1 | Admitted-Finance |
| 2 | L2₹8.4 LAdmitted-Finance | +13.88% | ₹8.4 L | L2 | Admitted-Finance |
Tender Value
₹7.3 L
EMD Value
₹14,700
Closing Date
26 Jun 2026, 6:00 pmClosed
Executive Engineer PWD Electrical Div. Ist Jodhpur
Executive Engineer PWD Electrical Div. Ist Jodhpur
Replacement of 315 KVA Transformers for IDI lab at KNCH hospital Jodhpur
2026_CEPWD_569804_2
NIT No.12/2026-27 of EE PWD Elect.Dn.I Jodhpur
Open Tender
Electrical Works
25 days
Executive Engineer PWD Electrical Div. Ist Jodhpur
Please refer Tender documents
3 documents required · 3 mandatory
₹500
Secretary, RREIS Executive Engineer PWD Electrica
₹14,700
Yes
Executive Engineer PWD Electrical Div. Ist Jodhpur
29 Jun 2026
20 Jun 2026
27 Jun 2026
20 Jun 2026
26 Jun 2026
20 Jun 2026
22 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S I T C of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 ( Correspnding level as per BIS amended upto date of receipt of tender) & BIS approved as per IS 2026- 1977 & losses as defined as per 2014 (Fourth Revision) Level-1 including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, undirectional rollers as required including carrying of pre-commission Testing & Charging of Transformer complete in all respect .
Factory Tests : The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) in OEM's own lab and same shall be witnessed by Department engineer.
Site Tests : Following tests shall be carried out on each transformer at site by OEM engineer in presence of department's site engineer:- a) Ratio test on each tapping.b) Resistance of windings at principal and all tapings.c) Insulation resistance of the winding between HV to earth / HV to LV / LV to earth.d) Vector group test.e) Magnetic Balance test.
Transformer shall be tested from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor) | - | - | - | - |
| 3 | 315 KVA with Off -LTC (+5% to - 10% @ 2.5%) with % impedance 4.5 | 1 | Set | 7,15,795.08 | ₹7,15,795.08 |
| 4 | Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 including testing etc. as required of following sizes. | - | - | - | - |
| 5 | 11 KV End Termination Kit Indoor type | - | - | - | - |
| 6 | 3 core 50/70/95 Sq.mm | 2 | Each | 4,189 | ₹8,378 |
| 7 | 11 KV End Termination Kit Outdoor type | - | - | - | - |
| 8 | 3 core 50/70/95 Sq.mm | 2 | Each | 5,226.22 | ₹10,452.44 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
Tendernotice_2.pdf
PDF • 0.28 MB
Tendernotice_3.pdf
PDF • 1.91 MB
BOQ_1013931.xls
BOQ • 0.22 MB
Download all tender documents and submit your bid