Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC PLOT NO D 2 COAL DEPOT FOSBERY ROAD SEWRI E MUMBAI 400 015 | MUMBAI | MUMBAI | MAHARASHTRA | 400015 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹8.9 L+₹5,925 (0.67%)Rejected-Finance G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA 390 002 | VADODARA | VADODARA | GUJARAT | 390002 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹9.1 L+₹27,486 (3.11%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTER SARU SECTION ROAD JAMNAGAR 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹9.8 L+₹94,965 (10.7%)Rejected-Finance | L4 | Rejected-Finance Being L4 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
9 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIR AND MAINT OF STREET/SECURITY LIGHTS AND ITS CONNECTED ITEMS AT MAKARPURA AF STN BARODA
2021_MES_420511_1
8607/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹19,000
Yes
6 Apr 2021
9 Feb 2021
11 Mar 2021
9 Feb 2021
9 Mar 2021
24 Feb 2021
11 Feb 2021 - 15 Feb 2021
60 days
Amount
Comprehensive maintenance (labour only) of street light fittings comprising of 4x24 W T5 Fitting 150W /250W /400W HPSV Fittings/400W MH lamp fittings / LED Street light fitting/Solar Street light fitting of any make any model fitted on the pole at any height with any type of fixing arrangement by replacing the ignitor, ballasts, capacitor, copper wire/Al wire two core 2.5 sqmm/4sqmm, drivers, clamps, nuts and bolts and lugs all as directed by Engineer-in-Charge (Comprehensive maintenanace also includes taking down street light fitting of any capacity from any height from the steel tubular pole/wall and increase or decrease the height of the fixing arrangement by removing the bent pipe and clamps and refixing it at the proper height and removing all the hanging wires, cables, PVC pipes, old rusted clamps, hanging aluminium wires etc and tightening of all nuts, bolts, clamps and fixing of the street light at proper direction to the satisfaction of Engineer in charge.) Note : (i) T&P including ladder for repair works shall be arranged by the contractor at his own cost. (ii) Spares to be raplaced under Comprehensive Maint shall be measured and paid Seprately under respective supply only items. However, quoted rate is deemed to include for fixing element of supply only items.
Supply only following spares for light fittings:- Note for supply only item Nos 2.01 to 2.08: Supply only items shall be deposited by contractor first in store yard of AGE E/M (AF) Makarpura and same shall be issued by the department to the contractor/his authorised rep on daily basis as per nature and as required at site. A register shall be maintained by the contractor or his authorised rep for the stores / materials supplied by the contractor to the department and then issued by the department to the contractor on daily basis. The register shall be kept in the custody of concerned JE. However payment shall be alowed only after fixing the item in proper location.
Supply only in replacement lamp T5 High efficency 24 Watts FTL double end Slim tube type all as directed. MAKE:HAVELLS Cat No, LHST27124699 or equivalent in Philips,
Supply only in replacement electronic Ballast T5 2x 24 watt FTL complete all as directed.
Supply only in replacement T5 lamp side holder suitable for T5 security light fitting 1x 24 watt complete all as directed. Make : CG, Philips,Havells
Supply only in replacement lamp suitable for metal halide luminous suitable for 400 Watts single and tubular type all as directed.
Supply only in replacement Electronic ignitor for suitable for 150W/250W/400W HPSV/HPMV lamp all as directed.
Supply only in replacement Electronic capacitor suitable for 400 Watt MH lamp all as directed.
Supply only in replacement open construction heavy duty VPIT copper ballast for metal halide luminous of 400 watt MH all as directed.
Supply only in replacement LED driver (control Gear) suitable for LED security light 70/75 watt, Input 100V to 400 V, 50 Hz 500 ma, 380 v cut off out put (Vdc) 70 - 75 V at PF 0.9 at IP 65 complete all as specified and directed by engineer in charge.
Disconnecting /taking out old defective PVC cable from wall/poles and supply and fix new copper conductor cable of size 2 core 2.5 sqmm PVC insulated, unsheathed, 1100 V grade with suitable cable glands/lugs fixed on wall/poles or passing through pipe as required at site complete all as specified and directed.
Taking down existing unserviceable brackets of light fittings including FI clamps of any description and in any position and supplying and fixing new brackets made out of 20 mm dia light grade GI pipe 1.50 mtr long bent to shape and size fixed on location using new 30x5mm FI clamps made to shape, nuts, bolts & washers complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out existing PVC boxes of any description and in any position on poles or fixed in the plinth of poles and supplying and fixing in position new street light box of PVC consisting of 01 No MCB 10Amps, 10 Ka capacity and 4 Nos ebonite insulators (3 phase and neutral) including aluminium strip for incoming and outgoing cable with necessary connection, clamps, nuts,bolts, lugs, duly fixed on the pole with suitable size of MS clamp as approved and directed by Engineer-in-Charge. Make : Sintex
S&F in repair High efficency LED street light fitting of 75 Watt with aluminium pressure die cast housing toughened glass in the front and Peanuts lens for bat wing light distribution including suitable Bracket Made up of GI pipe of 25 mm dia light grade with 4 Nos of Fastners for Fixing LED fitting Street /Security light on pole / Wall at any height and Necessary Electrical connection complete all as specified and directed Make : Halonix Cat No . HLSLD-ML04-75-CWL / Orient Cat No LSFS-080-C / C & S Cat No LTESS 30x 2.5 HPLED/LS
Supply and fix in repair energy saving environmental friendly long life asthetically designed with symmetrical distribution with high power LED light post top lantern fitting 25 watt complete all as specified and directed Make : Havells Cat No RUBYPT25WLED757PSYMTOPC / Orient Cat No LLOP-30-C / Halonix Cat No HLPT04-25-CW
S&F in repair High efficency IP 66 integral type mid power LED flood light fitting of 60 Watt made of pressure die cast aluminium housing with toughened glass10 Kv SPD w/o lens complete all as specified and directed. Make. Halonix Cat No. HLFLD-ML-17-60-CW / Orient Cat No LFGM-060-C / C & S Cat No LTEF 60WHPLED.
Supply and fix in repair GI tubing 40 mm dia bore light grade for protection of cable at wall/trench with fixing accessories including cutting on road or walls and making good the surface with plaster or PCC 1:2:4 complete as required at site all as directed By Engineer in Charge.
Supply and Laying PVC insulated armoured heavy duty LT UG electric cable 4 core x 16 sqmm with aluminium conductor 1100 volts grade with suitable cable glands and lugs laid in trenches/fixed on walls/poles or passing through pipe etc complete all as specified and directed.
S&F in repair MCCB 4 pole 63 Amps, 415 volts, 10 Ka complete all as specified and directed
S&F in repair MCB, SP, 06-32 Amps, 230 volts, 10 Ka complete all as specified and directed.
Repair/servicing of unserviceable/jammed motor operated swivelling type high intensive search cum flood light control gear motor and fiber based rotating disc of revolving mechanism motor, inbuilt speed reduction unit (5-10 RPM) speed control unit with reverse/forward facility and all motor over oiling, servicing for free movement of equipment complete all as directed by Engr-in-charge at site.
Disconnecting/dismantling and removing unserviceable time switch of any description from panel and supply, fixing, connecting and testing new Multifunctional digital time switch supply voltage 215-240 volts AC, 50 Hz complete all as specified and directed. Make : SCHNEIDER cat part No CCT15720 or equivalent of make LEGRAND/ L & T
M&L for preparation of existing old painted surfaces of LT/HT steel tubular electric pole/struts of any height and of any description and painting complete including bracing clamps and cross arms/channel clamp etc with one coat of aluminium paint and painting in white/blue alternative strips of 30 cm width each all around the poles up to 1.5M height from ground level/top of PCC copping including writting pole numbers/letters in capital stencil cut decorative manner on pole using fluorescent paint complete all as directed. Note: i) Pole painting will be measured only after completion of writting of Pole number as specified by engineer in charge at site. ii) Details of Pole numbers i.e., starting and finishing numbers in various locations shall be as briefed by JE E/M.
Trimming of branches on tree top up to 2.5m long and n.exc 50 mm dia coming in contact with street light poles/security light irrespective of the size of the tree and cleaning all around the poles for grassses etc by using necessary tools and ladders complete all as directed by engineer in charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft/loose soil for lying of cables etc complete all as specified and directed by Engineer-in-Charge
Removing surplus excavated soil to a distance not exc 50m and depositing where directed at level n. exc 1.5m above the starting point complete all as specified and directed.
Returning filling excavated soil in trenches including spreading, leveling watering and well ramming in layers not exceeding 25cm thick each all as directed by Engineer-in-Charge.
M&L for sand cushioning to cables with using clean dry and natural river sand and gently punning below/around cable complete all as specified and directed. Note : Punned thickness shall only be measured for payment.
M&L for well burnt bricks sub class ‘B’ as in protection of cable laid dry, flat abutting each other width wise complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B2 using 20mm graded stone aggregate as in coping of poles using necessary form work including dismantling existing broken coping complete all as specified and directed.
M&L for cutting chases in hard standing road/path/drain making holes in concrete wall etc for passing through of cable and making good surfaces as existing by using PCC (1:3:6) type C-2 using 40 mm graded stone aggregate complete all as specified and directed.
City Light
M/s SK Traders
Shiv Kripa Tradimg
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .