Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.9 LAccepted-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹74.3 L+₹3.9 L (5.49%)Rejected-AOC H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | L2 | Rejected-AOC Rejected | |
| 3 | Rejected-Technical SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | - | Rejected-Technical Enlistment letter not uploaded |
Tender Value
₹59.9 L
EMD Value
₹1.2 L
Closing Date
3 Sept 2024, 6:00 pmClosed
CWE Dehradun
HQ CWE Dehradun
REPAIR AND REPLACEMENT OF OVER HEAD LINE, CABLES, VCBS, PANEL, TRANSFORMERS AND CONNECTED ITEMS AT GARHI CANTT AREA UNDER AGE E/M-II OF GE DEHRADUN
2024_MES_661447_1
9934/DDN/E8
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
GE Dehradun
₹1.2 L
Yes
30 Apr 2025
22 Jun 2024
5 Sept 2024
22 Jun 2024
3 Sept 2024
13 Jul 2024
Amount
M &L disconnecting and taking out old unserviceable damaged/burn out cable of any size & make and supplying, laying, jointing and testing LT underground cable, heavy duty cable of size 10 Sqmm 4 Core, 1100 Volts, XLPE insulated and PVC sheathed, armoured, multi-stranded aluminium conductor cable conforming to IS , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly protected in galvanised steel pipe of suitable sizes all bare conductor of cable including cable gland and lugs etc at both ends incl disconnecting and taking out unserviceable damaged cable complete all as specified and directed. Note : Exc, earth work, cable sand cushioning & cable protection shall be measured separately under relevant items of this schedule.
All as per item No 1 here -in- before but 16 Sq mm,4 core
All as per item No 1 here -in- before but 25 Sq mm, 4 core
All as per item No 1 here -in- before but 50 Sq mm, 3.5 core
All as per item No 1 here -in- before but 95 Sqmm 3.5Core
All as per item No 1 here -in- before but 120 Sqmm 3.5Core
All as per item No 1 here -in- before but 150 Sqmm 3.5Core
All as per item No 1 here -in- before but 185 Sqmm 3.5Core
All as per item No 1 here -in- before but 300 Sqmm 3.5Core
Excavation in trenches in any type of soil not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for laying of cable, foundation etc and getting out complete all as specified and directed.
Sand cushioning & covering of UG cable using crushed metal sand in trenches for cable protection complete all as specified & directed.
Bricks, old size sub class `B' laid in trenches with width wise along the alignment of the cable as protection complete.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and directed
Removing excavated material not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified.
M&L for laying reinforced precast concrete cable cover (For HT Cable Only), Class LV, Type I, flat, size 250x150x40mm to U/G cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exc. 10mm over UG cable for cable protection in trenches all as specified and directed by Engineer-in-Charge.
Laying retrieved PCC cover , during the excavation for the replacement of fault cable (For HT Cable Only), laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over UG cable for cable protection in trenches all as specified and directed by Engineer-in-Charge.
Cutting existing road/hardstand of any type by using crow bar chisel upto a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Taking out of HT cable 95 to185 Sqmm 3 core of any size from ground or poles etc and testing for serviceability and kept aside for reuse incl proper rolling, loading unloading, transportation etc complete all as specified and directed. Note:- Earth work for the same shall be measured and paid separately.
Laying only HT Cables in ground including unrolling, unloading, transportation etc testing connections complete all as specified and directed. (a) Existing serviceable cable 95 to185 Sqmm 3 core in ground retrieved against item No 18. (b) Cables issued on Sch 'B' from store through Gate Pass/store Indent
M & L for under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts (earthed) grade copper sheet wrapped cross sectional area 95 sqmm 3 core including taking down of old unserviceable cable complete all as specified and directed.
All as per above item No 20 here-in-above but 120 Sqmm 3 core.
All as per above item No 20 here-in-above but 185 Sqmm 3 core
M & L for cable end jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 sqmm incl testing after jointing complete all as specified & directed.
All as per Item No 23 here-in-before but 11 KV 240 to 300 Sqmm
M & L for cable end jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 sqmm including testing after jointing complete all as specified & directed.
M & L for straight through cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 sqmm including testing after jointing complete all as specified & directed.
S&F station class type lightning arrestor suitable for 33 KV discharge current 65 KA fixed on existing steel structure including connection with earth strip conforming IS 3070 (Part -3) 1983 Class 'A' complete all as specified and directed including taking down existing old unserviceable complete all as specified and directed.
M & L for lightning arresters silicone rubber type 12 KV grade complete with all fittings, station class, discharge capacity 65 Kilo Amps complete all as specified and as directed including taking down old u/s lightning arresters complete all as specified and directed.
S&F of Insulator pin type porcelain vitreous, white brown or green 150mm height and 150mm dia including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut for conductor working pressure 33000 volt grade complete all as directed including disconnection and taking down existing lightning arrestor complete all as specified and directed.
M&L for replacement of old u/s HT studs of transformer any type or size including taking out transformer oil opening up of top lid and replacement of unserviceable studs including top up of oil replacement of gasket etc and making transformer leak proof complete all as specified and directed.
M&L for replacement of old u/s LT studs of transformer any type or size including taking out transformer oil opening up of top lid and replacement of unserviceable studs including top up of oil replacement of gasket etc and making transformer leak proof complete all as specified and directed.
M&L for servicing 33 KV yard structure complete with following works (a) Replacement u/s jumper, sleeves vice type conductor, bolt nut and washers connecting lugs/thimble knife contact. (b) Applying petroleum jelly to the moving as well as fixed contacts (c) Tightening all the connection for its smooth functioning (d) Preparing old painted surface of this structure such as poles, cross arms, bracing supports, clamp and back plate complete painting of two coats of anti corrosive weather proof heat resistant aluminium paints over a coat of red oxide zinc chrome primer and providing Red/Yellow and Black paint including writing SM/MES NO or all other direction/marker/ code etc. with grey/black paint on boards etc. not less then 40mm height & 10mm thick complete all as specified and directed. Note: No extra payment will made for the spares required to keep the yard structure in satisfactory functional throughout contract period other than given in schedule for once in 3 month.
S&F in replacement following equipment/electrical parts of MRS Yard 33KV Substation all as specified and directed by Engr -in-Charge (a) ACSR conductor sleeves insulated HT 33 KV(Panther/Dog) as per sample should be collected from MCM/JE E&M - 300 Mtr (b) Clamping N Connector - 50 Nos (c) Clamping T Connector - 50 Nos (d) Nuts, Bolts, washer - As per site requirement
Supplying in replacement of existing unserviceable control cable including laying or fixing with saddles or cable tie etc, jointing and testing LT PVC insulated copper conductor armoured electric power cable ISI marked with multi stranded copper conductor heavy duty 1100 volts grade of 2.5 Sq mm 4 core complete all as specified and directed. (Purchase voucher and Test certificate to be subitted)
All as per item No 34 here -in-before but 2.5 Sqmm 6 core complete all as specified.
Supply & filling the new transformer oil of rupturing capacity 50KV for 60 Sec for topping up to required level of transformer complete all as specified and directed. Note :- Separate register should opened for record of following data & submit to Engr-in-Charge before RAR/payment ; (a) Location (b) SM/MES/ Manufacture Number (c) Capacity (d) Date and time of Job (e) Qty of oil before top up (f) Qty of Oil poured into the transformer (g) Signature of MCM, JE E&M, Engr-in-Charge and user.
S&F transformer breathers transparent of standard size suitable for 5 MVA transformers 33/11 KV volts cast alluminium transparent type including removing the existing unserviceable one complete all as specified and directed.
M&L Filtration/dehydration of the existing transformer oil at site of any make of transformer and capacity up to required dielectric strength as per IE rules and refilling in the transformer up to required level complete all as specified and directed. Note :- The dielectric strength shall not be less than 65 KV for 33 KV Tfr & 45KV for 11 KV tfr after filtration process) Note :- Separate register should opened for record of following data & submit to Engr-in-Charge before RAR/payment ; (a) Location (b) SM/MES/ Manufacture Number (c) Capacity (d) Date & time of Job (e) Qty of oil before top up (f) Qty of Oil poured into the transformer (g) Signature of MCM, JE E&M, Engr-in-Charge and user. (h) Test cetificate of Oil before and after dehydration each transformer
M&L for transformer cable boxes or LT panel board cover/panel doors etc made out of 3.0 mm CRCA sheet duly powder coated complete to make the system safe and secure complete including making hole nut bolts washer etc all as per site requirement complete all as specified and directed.
Dismantling and taking out old unserviceable cross arms and M&L for cross arms, bracing, supports clamps back plates, gantry bay structure etc fabricated from structural steel section such as suitable I section channel ISMC angle iron and flat iron GI nut, bolt & Washers with welding, cutting, drilling hole etc for insulator bolts clamps in any shape and size including one coat of red oxide and two coats of epoxy heat resistant paint all complete all as specified and directed.
Dismantling existing steel poles/ struts, any size carefully for reuse including necessary excavation demolition of concrete shifting cost etc. and removing the old unserviceable rubbish etc complete all as specified and directed.
Fixing only of steel poles of any length and dia retrieved against respective item of demolition/dismantling including loading, shifting unloading erection in true vertical position complete all as specified and directed.
S&F disc type insulator (single disc assembly) porcelain vitreous, white brown or green 145 mm height and 255 mm dia ball and socket type with tension clamp galvanized iron nut for conductors working pressure 11000 volt grade complete including disconnection and taking down existing insulator complete all as specified and directed.
S&F Insulator pin type porcelain vitreous, white brown or green 150mm height and 150mm dia including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut for conductor working pressure 11000 volt grade complete including disconnection and taking down existing insulator complete all as specified and directed.
Taking down of GOD vertical/Horizantal mounted including insulator and opening mechanism for servicing repair or replacement to existing GOD switch with DO fuse of any size complete all as specified and directed.
M & L for switch Air break gang operated triple pole out door type 11 KV 50 cycle AC(GOD) suitable for current rating upto 200 Amps mechanically operated mounted on silicon rubber insulators (12 insulators) and frame with operating mechanism from ground level with earth switch and including locking arrangement complete all as directed.
M&L for fixing only of existing GOD any type or size after repair incl replacement of blades bushings etc complete all as specified
M&L for Trimming/ pruning of tree branches up to 5 meters above & below and both sides to obtain clearance all around the LT over head lines / HT over head lines conductor upto 5 mtr from furthest conductor between Each adjuscent Pole including removing of cut branches and cleaning of site complete all as specified and directed.
M&L for painting to existing 4 pole structure including pole, cross arm, bracing clamps, GO DO fuse etc with 2 coat of heat resistance aluminium paint above coping complete all as specified and directed.
M&L for painting to steel pole including pole, cross arm, bracing clamps, etc with 2 coat of heat resistance aluminium paint above coping complete all as specified and directed.
All as per item No 49 here -in-before but 2 pole structure complete all as specified.
M&L for spraying of agricultural based chemical inside the installation to control the growth of unwanted herb, shrubs etc including cutting, removing the vegetation growth & surface dressing all around the installation yard/ transformer /LT panel Board area external only to keep installation always clean and tidy condition complete all as specified and directed. Note:- (a) All the installation yards/area shall be kept clean throughout contract period by repeatedly removing the grass / shrubs as many times required depending on the growth of grass (b) measurement will be measured & paid time to time whenever requested by the Engr-in-Charge as per growth of grass/shurbs/creapers and any event/inspection/visit of high official.
S & F in replacement MCCB 3/4Pole, 400 Amps, 36 KA, 415 V , with adjustable thermal & adjustable magnetic setting Ics=100% Icu complete all as specified and directed.
All as per item No 53 here in above but MCCB 4Pole, 320 Amps, 36 KA, 415 V
All as per item No 53 here in above but, MCCB 4Pole 250 Amps, 36 KA, 415 V ,
All as per item No 53 here in above but MCCB 4Pole, 200 Amps, 25 KA, 415 V
All as per item No 53 here in above but MCCB 4Pole, 160 Amps, 25 KA, 415 V
All as per item No 53 here in above but MCCB 4 Pole, 125 Amps, 25 KA, 415 V
All as per item No 53 here in above but MCCB 4 Pole, 100 Amps, 25 KA, 415 V
All as per item No 53 here in above but MCCB 4Pole, 63 Amps, 25 KA, 415 V
Supply and lay in trenches fixed to poles wall laid in floor GI steel tubing 80mm bore (dia) medium grade of following bore including fitting bolt, nut & washers etc or wooden rubber bushing at the ends of complete all as specified and directed incl disconnection and taking down existing tubing complete.
All as per item No 61 but 40mm bore (dia)
Taking down existing connection from LT Panel/Bus Bar Chamber/Feeder Piller/ Electric Poles/ Building carefully (any capacity ,any type) carrying out repair work at site including replacement of unserviceable/ defective screw/nut & bolts/ Washers/Lugs/ Spreaders/Hinges of doors/Repair to Locks & handles/ Indication Lamps/meters/Cable glands/Bus Bar (Copper/Aluminium) etc, refixing the fittings in its original position, testing and commissioning, including removal of bushes, creapers and trimming of branches around the LT Panel/Bus Bar Chamber/Feeder Piller/ Electric Poles at site complete all as specified and directed . Note: (i) If any major repair is required, attending complaints and replacement of any nature in LT Power network at any point and time, the items shall be replaced and paid seperately under relevant item of sch 'A' (ii) Tools, ladder, vehicle required to carry out the work shall be provided by the contractor. (iii) Contractor will ensure the safety of the workers employed at his own risk. (iv) Contractor shall provided Skilled ITI Electrician and Produce the Certificate before the commencment of work. (v) Contractor should ensure to rendering completion of all attended complaints to respective JEs/Engr-in Charge as day to day basis .
Supply and fix, cable jointing kit for straight through heat shrinkable type joint with jointing material and all connected accessories suitable for XLPE armoured aluminium conductor cable 1100 volts grade of size 3.5 core 240 to 300 sqmm including taking down of old existing joint complete all as specified,and as directed.
All as per item No 64 here in above but cable jointing kit of size 150 to 185 sqmm
All as per item No 64 here in above but cable jointing kit of size 70 to 120 sqmm
All as per item No 64 here in above but cable jointing kit of size 25 to 50 sqmm
All as per item No 64 here in above but cable jointing kit of size 6 to 16 sqmm
S & F in replacement LED indication Lamps (RYB) complete all as directed.
M&L for earthing complete with GI or steel earth plate electrode 60cm x 60cm x 6mm connected to galvanized iron strip 25x4 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer nuetral/body/ Lt panel etc. and testing on completion, complete all as specified & directed by Engr-in-Charge.
All as per item No 71 here-in-above but earthing with GI Srip of sixe 32x 6mm, complete all as specified & directed by Engr-in-Charge.
S&F insulator pin type porcelain vitreous white, brown or green LT 1100 Volt including 01 galvanized M.S.spindle, two galvanised iron washers and one galvanised. iron nut of size 100mmx65mm all as specified and directed by E-in-charge including disconnection and taking down existing insulator complete all as specified and directed.
S&F shackle type insulator porcelain vitreous LT 1100 Volt 100x115mm including G.I. mild steel strip at 31 x 6 mm 12mm dia insulator bolts, washers, nuts suitable for working pressure 1.1KV including disconnection and taking down existing insulator complete all as specified and directed.
S&F of oval shape min 65 mm dia or higher size cable route indicators HT or LT made out of cast iron and fixed on 25 mm equal angle of 45 cm long complete including grouting the same in PCC complete all as specified and directed.
M&L for shifting of LT Panel/Bus Bar Chamber/Feeder Piller from the foundation duly disconnectig existing inoming/out going connection carefully (any capacity ,any type) and re-installed where ever directed by Engr-in-Charge, duly necessary connection and PCC foundation and earth work etc complete all as specified and directed
Taking down/dismantling LT Panel/Bus Bar Chamber/Feeder Piller from the foundation duly disconnectig existing inoming/out going connection carefully (any capacity ,any type) for caryout repair all as specified and directed.
S&F Rolled mild steel sections as in framing for panel board , stand, cladding, glazing and the like fixed with angle cleats and connecting plates, etc. and fixing conforming to Fe-410-W (Gde-E-250) quality A complete all as specified and directed.
M&L for fabricating MS CRCA sheet of 3mm thick, the inner shell duly compartmented for each control gear, including Powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements welded with exisiting panel complet all as specified.
M&L for fabricating and fixing alluminium bus bars of exisiting gauge/size duly connected with existing incoming/outgoing connections complete all as specified.
S&F Cable glands of size 10 to 16 Sqmm duly connected with existing incoming/outgoing connections complete all as specified.
S&F Cable glands of size 25 to 35 Sqmm duly connected with existing incoming/outgoing connections complete all as specified.
S&F Cable glands of size 50 to 70 Sqmm duly connected with existing incoming/outgoing connections complete all as specified.
S&F Cable glands of size 95 to 120 Sqmm duly connected with existing incoming/outgoing connections complete all as specified.
S&F Cable glands of size 150 to 185 Sqmm duly connected with existing incoming/outgoing connections complete all as specified.
S&F Cable glands of size 220 to 300 Sqmm duly connected with existing incoming/outgoing connections complete all as specified.
S&F Cable glands of size 400 Sqmm duly connected with existing incoming/outgoing connections complete all as specified.
M&L for painting of LT Panel/Bus Bar Chamber/Feeder Pillar box of any type & size, apply 2 coat of synthetic enamell smoke gray paint over a coat of red oxide primer surface complete all as specified.
M&L for replacement of old U/S CCTV camera system at MRS GarhiCant with following equipmets and accessories ; (a) DVR (b) 10 Nos of Camera (c) UPS suitable capacity (d) LED TV32 of Make Samsung, LG, Sony (e) Wire for connection of camera and DVR - 300 mtr (f) Software should be enable with Mobile application , including wifi connection all complete all as specified. Note :- (i) Wifi conecction of reputed company with sufficient speed and data to be provide by the contractor and monthly paid bill should be sumitted to to this office before 5th day every month. (ii) Wifi subscription to be paid the contractor till the final of said contract. (ii) The contractor should install the CCTV and all connected job within 10 days from date work order.
M&L for fault detection in UG HT cable of any size or type at any depth with fault locator including material T&P required for the same and testing complete all as specified and directed. Note :- 1. Joint, excavation laying only of cable shall be measured and paid separately. 2. Each fault shall be treated as one job and contractor have to address the said fault immediately.
M&L for attending fault/ breakdown in Over Head line /Breaking UG Cable due to any reason like falling of tree branches, Bird hits, Cracking of Pin/ Disc insulator, breaking Over Head conductor complete including patrolling of LT line, Meggering, removing of fault, replacement of insulator any type, replacement of fuses and restoring the feeder complete all as specified and directed for following areas :- Notes : (i) All T&P & Man Power required to complete job is included in unit rate. (ii) Unit rates also included the conveyance & communication facilities required to complete the job. Note :- (a) Complaints slip Book will issue from the deparment and all the complaint will written the slip and to be submitted to the office at the time RAR/Bill and dor audit purpose. (b) Comlaint slip should be entered the nature of complaints and materials used and quantity of material which all are utilised for rectifying the complaint to be mentioned properly. (c) Complaint slip should signed by MCM/JE E&M and obtain user signatures on completion of job. (d) All the Complaint will be entered complaint slip and slip number should be entered on measurement book MB for RAR/Bill payment.
(a) MH feeder (Approximate 8 KM)
(b) New Cantt feeder (Approximate 12 KM)
(c) Upper Camp feeder (Approximate 10 KM)
(d) Mall Road feeder (Approximate 6 KM)
(e) RIMC feeder (Approximate 5KM)
(f) Birpur feeder (Approximate 9 KM)
(g) Ganghora feeder (Approximate 3 KM)
Taking out transformer from its position from location under GE Dehradun for repair/ servicing/ rewinding of following capacity with OLTC, 11/.415KV ,disconnecting/ opening HV, LV electrical, earthing connections
(a) 100 to 200 KVA
(b) 250 to 400 KVA
(c) 500 to 630 KVA
Transporation of transformer to authorized workshop (UPCL autorised company) by making necessary arrangements of T&P (crane, recovery, vehicle etc.) for the following capacities.
(a) 100 to 200 KVA
(b) 250 to 400 KVA
(c) 500 to 630 KVA
M&L for Opening of transformer top cover by extraction, removing of serviceable/ unserviceable nuts bolts and washers etc . Note : Contractor should carried Pre-inspection of transformer at the Company and obtain necessary photos and certificate of Coil cutting from the company duty signed by Inspecting officer and Forman/Engr-in-charge of the Company.
(a) 100 to 200 KVA
(b) 250 to 400 KVA
(c) 500 to 630 KVA
M&L for Draining out of transformer oil after taking proper shut down and disconnection of all electric connections.
M&L Lifting primary (HT) and secondary coil (LT) , dismantaling of transformer complete part by part carefully & display all the parts without damaging any portion for inspection.
(a) 100 to 200 KVA
(b) 250 to 400 KVA
(c) 500 to 630 KVA
M&L labour transformer winding including taking out and testing for serviceability and rewinding the same with fresh copper wire or strip including insulation paper bobins etc and keeping the same into the hot air oven till the moisture will remove and insultating resisitance improves to the satisfaction level, refixing the same in original position all as specified and directed by Engr-in-Charge (Old copper scrap will be retained by contractor, rate to quote for Note :- (a) Transformer issued to the contractor through issue voucher and gate pass. (b) Inspection of transformer to be carried out before lifting the transformer and signature to be obtainted from Contractor , JE E&M, and Engr-in Chage as per inspection report. (c) Transformer oil to be drained out and kept with MES store yard/MRS before despatch to the company (d) Transformer should be rewinded through authorised dealer of manufacturer company and authorisation certificate and bills of cost of rewinding to be submitted before payment. (e) Contractor should be applied throough letter "before & after inspection" at the factory and copper/ alluminium winding should be cut/break and necessary photograph tob obtained. (f) Contrator and inspecting officer mentioned the quantity/weight of old copper/alluminuim winding on the inspection note. (g) Test certificate, Warranty certificate, Copy of Job order to be submitted before payment. (h) New oil as per to be fill up on tranformer and quantiy to be measured and paid seperately on relevant item. (j) The dielectric strength transformer oil shall not be less than 50 KV. (k) All the unserviceable and retrieved parts of transformer during the winding , shall be procuced at MRS Garhi Cantt and issued to contractor as schedule credit through issue voucher and gate pass the number IV & Gate pass number shall be entered on th MB.
M&L for Replacement of Press Board & Insulation
(a) 100 to 200 KVA
(b) 250 to 400 KVA
(c) 500 to 630 KVA
M&L for Replacement of Gasket & washer
(a) 100 to 200 KVA
(b) 250 to 400 KVA
(c) 500 to 630 KVA
M&L for Replacement of Silica Gel Breather (Main Tank + OLTC Tank)
(a) 100 to 200 KVA
(b) 250 to 400 KVA
(c) 500 to 630 KVA
M&L for Complete overhauling of On Load Tap Changer (OLTC) and including replacement of wiring cunductors, connectores including wiring of control cable connections and connection , all specified and directed
(a) 100 to 200 KVA
(b) 250 to 400 KVA
(c) 500 to 630 KVA
Replace ment of HV & LV Termination
(a) 100 to 200 KVA
(b) 250 to 400 KVA
(c) 500 to 630 KVA
Replacement of sundry items like Tapes, Sleeves, Bakellite, Nut & Bolts wherever required.
(a) 100 to 200 KVA
(b) 250 to 400 KVA
(c) 500 to 630 KVA
Heating, Drying & Meggar Improvement
(a) 100 to 200 KVA
(b) 250 to 400 KVA
(c) 500 to 630 KVA
Reassembling the transformer complete with all existing serviceable parts and new parts as per requirement i.e. Repair labour charges
(a) 100 to 200 KVA
(b) 250 to 400 KVA
(c) 500 to 630 KVA
Return back from OEM Workshop with Placement of transformer to its position at location under GE Dehradun after repair/ servicing/ rewinding of capacity 11/0.433 KV Reconnecting HV, LV electrical connections, earthing connections along with following other works like checking & testing of HT line / HT Cable, HT Switchgear etc. Note:- (a) All routine tests will be carried out at manufacturer works (b) Transformer will have warranty period of 6 months from the date of re-fixing at site. (c) UPCL authorised delaers/representative should be available at the time of commissioning of transformer. (d) Any other work required to carryout above job in inclusive.
(a) 100 to 200 KVA
(b) 250 to 400 KVA
(c) 500 to 630 KVA
M&L for callibration & servicing of HT RMU 11/12KV, 400 /630 Amps complete with repair & replacement of followoing componets complete all as specified and directed. (a) SF6 filling Pressure of insulating Gas - 1.2bar.abs , Min 1.1 bar abs (b) Switch Fuse unit :- Rated current 200Amp, Propspective fault withstand - 20kA rms (c) Bushings Series 400 (DIN 47632)with adapted lin-in-line bolted connecttion - 630 Amp (d) Gas density gauge (e) Rubber isulated boots for terminals (incoming & outgoing) (f) Necessary nuts , bolts, washers to replaced where ever needed for the instruments. Note : 1. No extra payment will made for the spares required to keep the yard structure in satisfactory functional throughout contract period other than given in schedule for once in 3 month. 2. Contractor will place work/Job order to ABB and make ensure only respresentaive shall be conducted inspection and all callibratio/servicing. 3. Bill should submitted to the before RAR/Payment.
Supply & erect 4 pole structure on 11 meter steel tubular pole consisting of pole with anti-climbing device, PCC foundation, cross arms, 4 Nos of GODs Assy (with 12 insulators) etc for 1 incoming and 3 out going all as specified and directed.
Supply & erect 2 pole structure on 11 meter steel tubular pole consisting of pole with anti-climbing device, PCC foundation, cross arms, 2 Nos of GODs Assy (with 12 insulators), etc for one incoming and 3 out going all as specified and directed.
Dismatling of Transformer of any size/capacity from 2/4 Pole structure, duly disconnecting exisiting cable carefully and re-connect after the mounting to the PCC foundation and HT Poles and accessories should be deposited to MES store for re - installation complete all as specified and directed
M&L for Loose filling with aggregates of gauge 40 to 80 mm in surrounding of Transformer permisses all specified and directed
M&L for Shifting of transformer from any site on necessary transportation and lifting arrangements and place whereever directed by Engr-in-Charge
PCC 1:5:10 type E-2 using 40mm graded stone aggregate for foundation of poles stays etc as in mass concrete all as spd and directed
PCC 1:4:8 type D-2 using 40mm graded stone aggregate for foundation of poles/stays etc as in mass concrete all as spd and directed
PCC1:2:4 type B-1 using 20mm graded stone aggregate as in coping for poles/ stays etc incl necessary form work complete all as as spd and directed
Rendering cement plaster 15 mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 finishing the surface even and fair without using extra cement complete and all as specified
Demolition of concrete of any description and in any position not otherwise specially provided for Complete all as specified and directed
Brick work with sub class B bricks straight or curved on plan not exceeding 06 mtr mean radius built in cement mortar 1:6 complete all as spd and directed
M & L rolled mild steel section 50 x 50 x 6mm/ 40 x 40 x 6mm or 25 x 25x 6mm angle iron fixed indepnedently without connecting plates etc. (cut to dead length up to and incl 20mm of the length indicated or directed), mild steel shallbe grade Fe-310-0 or Fe-410-0 complete all as specified and directed.
M & L for expanded metal cut to length bent to shape required with and incl annealed mild steel not less than 0.9mm dia or fixed with galvanised steel staples or welded with supporting steel memebrs. Weight XPM not less than 3.15 kg/sqm complete all as specified.
S&F Sheet metal enclosures with socket plug top and MCB' SPN enclosure with a two pin and earth plug and socket complete with one single pole 20 A MCB
S&F DB VTPN 6 way 415 Volts, 50 Hz indoor type double door Sheet metal enclosure IP-43 DB's flush mounted with 250 Amp Copper busbar for each phase with two neutral bar & two earthbar and cable ties for cable managenment including mounting arrangement including and fixing of MCCB 4 pole 415 volts as incomer including connection terminal strip complete pre wired with suitable size copper conductor. The DB's should hold type test certificate (CPRI) as per IEC 61439-3 complete all as specified and directed by Engr-in-charge,
S & F sheet metal enclosure DB SPN when MCB's to be used 12 way with 200 amps bus bar and double door complete all as specified and directed.
S&F MCB SPN 240 Volt 10 KA 40 Amp conforming to IS complete all as specified & directed.
S&F MCB SP 6 to 32A
M&L for submain wiring with 3 runs(N+P+E) of 1.5 Sqmm single core,PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 volts grade drawn through and including concealed/surface PVC conduit pipe of medium duty not less than 15 mm dia including necessary PVC conduit specials and connecting with suitable size thimble complete all as specified and directed. Note:-3 runs of 1.5 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
All as per item No 121 but with 3 runs(N+P+E) of 2.5 Sqmm single core copper FRLS conductor . Note:-3 runs of 2.5 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
All as per item No 121 but with 3 runs(N+P+E) of 4 Sqmm single core copper FRLS conductor .Note:-3 runs of 4 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
All as per item No 121 but with 5 runs(3 runs P+N+ 1 run Earth) of 6 Sqmm single core copper FRLS conductor and PVC conduit not less than 24 mm dia. Note:-5 runs of 6 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
M&L for under ground pneumatic horizontal drilling of holes (HDD) under road , more than 110 mm dia, pavement, hard standing as required length at site by trenchless technology using ultra sound technique with necessary horizontal direction drilling machine . The contractor shall be conduct under ground scanning to detect existing HT/LT cable line , sewage line, OFC Cable etc to avoid damage. The entry/exist hole must be large enough to fit the drilling tool and the operator in it so they can aim the tool. The hole also must be deep enough that as the tool compacts the ground and the surface to be remain undisturbed. The depth of the starting bore pit depends on the type of the soil that is being worked in and how well it compacts. The operator shall aim the tool to the desire exit point and allow it to perform it function creating a bore hole under the ground without disturbing surfaces. The operator also should monitor the surface to make sure that, it is undisturbed. As the tool near to the exit point it is slowed down and the exit pit should be dug to locate both the tool and the bore. As the tool enters the exit pit the operator should choose either dig up the tool to retrieve it or reverses the tool back into the first bore pit to retrieve it including connected earth work, complete all as specified and directed. Note :- Drilling should be executed at various places as directed by Engr-in-Charge
Supply & Laying of High density polyethylene pipes (HDPE) of pressure rating HDPE Pipes PN 6 size 110mm (4") laid in trenches for the protection of HT UG Cable all as specified and directed
Supply ,Installation, commissioning & testing of factory made ,any CPRI approved ,LT switched gear panel board,IP-54(outdoor type) ,415 voils,50 Hz,AC supply,three phase and neutral (4 wie) ,450 Amps aluminium busbars 4 pole ,duly insulted with heat shrinkable sleeve as per colour code supported on epoxy insulatators,having independent compartment for insulated busbar ,incoming feeder & each outgoing feeder ie cubical type ,made out of 3.15 mm thick CRCA sheet,rigid mild steel angle iron frame of 50mmx50mmx6mm with 900mm long extended legs grouting in PCC 1:3:6 type C2 block of size 300mmx200mmx300mm ,duly epoxy powder coated internally & externally with approved shade ,rubber gasket,hinged front & back openable doors with proper locking arrangements for dust and vermin proof ,complete including suitable size cable alley,lugs,cable glands,common earth bar of GI strip 32x6mm at bottom and making connections with MCCB spreaders/wiring with suitable size of single core PVC copper conductor cable ,locking arrangements 65mm size and lock with keys,earth work and excavation comprising the following : Make of Panel : ABB/Seimens/Schenider/L&T Incomer :- 250 Amps 4P, 35 KA ,Adjustable tharmal & fixed magnetic setting, Ics=100% of Icu with spreader link - 01 Nos. Meter set : Digital voltmeter,Ammeter + CT : 400/5,RYB Indicating Lamp LED type 240 V ,MCB SP 6A, KWH Meter : CT/PT operated Trivector Energy with TOD Meter,3 Phase 4 wire for measuring of LT Instanteneous & Intigrating Parameters with bright LCD Display Outgoing :- 100 Amp FP,25 KA,,Adj tharmal & fixed magnetic setting,Ics=100% of Icu with spreader link MCCB- 02 Nos. 63 Amp FP,16 KA,Adj tharmal & fixed magnetic setting, Ics=100% of Icu with spreader link MCCB- 02 Nos.
All as per item No 4 here-in above but LT Panel with following switch gear complete all as specified. Incoming :- (a) Insulation epoxy painted high conductivity copper bus bar 250 Amps for 3 phase and neutral complete all as specified and directed. (b) Digital Voltmeter 0 to 500 Volts - 01 set (c) Digital Ampere meter 0 to 200 Amps capacity - 01 Set (d) Indicating lamps Neon type for RYB - 01 set (e) MCCB 4 Pole 415 volts 125 Amps, 16 KA as incoming - 01 Nos. Out Going :- (a) MCCB 4 Pole 415 volts 63 Amps, 16 KA as incoming - 03Nos.
bharat contrectors (BID ID -3074085)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .