Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99,000Accepted-AOC | L1 | Accepted-AOC The Lowest Tenderer | |
| 2 | L2₹1.1 L+₹11,000 (11.1%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-Finance Not a Lowest Bid | |
| 3 | L3₹1.3 L+₹28,000 (28.3%)Rejected-Finance | L3 | Rejected-Finance Not a Lowest Bid |
Tender Value
Refer Docs
Closing Date
16 Sept 2023, 9:00 amClosed
Maj Anshuman Singh Chauhan
GE MH AND RH KHADKI
SHIFTING OF HIGH MAST LIGHT AT CSD DEPOT KHADKI STORAGE SHED
2023_MES_617391_1
3300/Q/05/E3
Limited
Miscellaneous Services
Supply
50 days
GE MH AND RH KHADKI
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
Exempted
7 Oct 2023
6 Sept 2023
19 Sept 2023
6 Sept 2023
16 Sept 2023
7 Sept 2023
SHIFTING OF HIGH MAST LIGHT AT CSD DEPOT KHADKI STORAGE SHED 1. Dismantling of Galvanized steel high mast lighting system of 16 meter high (Make- Bajaj electricals Ltd) carefully and stay at site for reinstalling in new location with 2/3 wire rope system and its accessories by disconnecting the electric connection of the high mast light from starter timmer panel, taking down the flood lights-06 Nos from the pole of height 16 mtr, unscrewing the foundation bolts of the hight mast pole and dismantling the structure with help of hydra crane, dismantling the electric panel complete and making good the damaged surface of the hard standing. Note :- (i) Quoted rates is to be inclusive of T&P charges of Crane/Hydra, ropes, JCB, Gas cutter and labours. (ii) All safety measures should be taken into account while completing the job done. (iii) Any loss or damage to the govt property made during execution of the job will be make good by the contractor itself at his own cost. (Qty -01, Rate 25950.00- RA attached). 2. Refixing the high mast light to new location nearly about 20-30 mtr distance by laying the foundation of the highmast pole as per the OEM's recommendation and drawing, fixing the high mast pole and refixing the LED flood lights back to its original position and making electrical connection to the lights. Note :- (i) The rates are all inclusive of excavation works in any type of soil/strata upto the depth and size as recommended by OEM (Bajaj Electricals Ltd). (ii) The rates of PCC for foundation of High mast pole along with Nut bolts (As per the OEM's recommendations) are included in the quoted rates. (iii) Quoted rates is to be inclusive of T&P charges of Crane/Hydra and labours.(Qty - 1.00, Rate - 41500 - RA Attached). 3. Dismantling old control panel of high mast light along with MS stand, cleaning it with blower and shifting it to new location as specified on site with proper relaying of the cabling work and PCC work for foundation of the panel. (Qty - 01. Rate -3245/- , RA Attached). 4. Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable of size 25 Sqmm 4 Core with stranded aluminium conductor 1100 volts grade confirming to IS-7098 (Part-I-1988) laid in trenches/duxts/wall/floor/pipes/poles including cable glands and aluminium lugs of appropriate size, pvc sleeve etc complete all as directed by Engineer-in-Charge. (Qty - RM-35, Rate 249.04, Amount - 8716.40, SSR -19242). 5. Dismantling the lighting conuctor rod from the high mast pole of 16 mtr height along with earthing strip and fixing it again to the high mast pole at new location and connecting the earthing strip to the nearest earthing complete all as specified and directed. (Qty - 01, Rate - 3630/-, RA Attached). 6. Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation of poles stays laying of electric cables, pipes etc and getting out in soft/loose soil complete all as specified and directed. (Qty-5.41 Rate - 383.7, Total Amount - 2075.82, SSR-3006). 7. Ditto item No 6 but in hard/dense soil (Qty-2.15 Rate - 675/- Total Amount - 1451.25, SSR-3006). 8. Removing excavated material soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. (Qty- 2.55, Rate - 320.4/-, Total Amount 816.38, SSR - 3029). 9. Returning, filling in, including spreading, levelling watering and well ramming in layers anot exceeding 25cm in soft/loose soil complete all as specified and directed. (Qty- 5.01, Rate - 139.1/-, Total Amount 697.17, SSR - 3009). 10. M & L for riddled earth for cushioning to under ground electric cable including spreading, levelling and hand punning complete all as directed, Note - Punned thickness shall only be measured & paid. (Qty- 2.27, Rate - 300/-, Total Amount 680.40, CA No GE (MH&RH)/KKE/22/2022-2023). 11. M &L for road cutting and boring of road without damage surface and inserts GI pipe and cable without damage of any size making good with PCC 1:3:6 type C-2 (using 40mm graded stone aggragate) of 150mm X 100mm in respect of width and thickness complete all as directed by Engr-in-Charge (Qty-RM - 6, Rate - 150/-, Total Amount 900, Assd) 12. Supply and laying un-reinforced precast concrete cable cover LV, Type I, flat, size 250mm X 150mm X 40mm for under ground cable all as specified and directed. (Qty- 187, Rate - 44.20/-, Total Amount 8250.67, SSR - 19222).
SKS Electricals
M/S EAGLE ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .