Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
17 Mar 2021, 11:30 amClosed
EEEANDMWSCN
EEEANDMWSCN NEAR KANHIYA NAGAR METRO STATION DELHI-35
Repairing/Renovation of internal/external electrification system at water emergency Gulabi Bagh
2021_DJB_201386_1
NIT NO. 22(2020-2021)
Open Tender
Miscellaneous Services
Item Wise
30 days
EEEANDMWSCN
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
THROUGH DJB OFFICIAL WEBSITE IN LINK TENDER
Exempted
23 Mar 2021
11 Mar 2021
17 Mar 2021
11 Mar 2021
17 Mar 2021
11 Mar 2021
Providing of Endura Linear NEO Surface and wall mounted LED batten, extruded aluminum housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver 20 W LED Make: Havells /Bajaj/ Philips/Crompton/ Wipro/DJB approved
Providing of Ceiling fan 1200mm sweep. Make: orient/Havells /Bajaj/ Philips/DJB approved.
Providing of 300mm exhaust fan 1400 RPM Make: Havells /Bajaj/ Philips/Crompton/DJB approved.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. DSR-18, item code-1.41
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C, DSR-18, Item code - 1.10.3
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. DSR-18, Item code - 1.12
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm +1 X 2.5 sq. mm earth wire. DSR-18, Item code - 1.14.2
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. DSR-18, Item No.- 1.31
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. DSR-18, Item code - 1.32
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. DSR-18, Item code-1.44
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing and commissioning etc. as required upto 450mm.
Supply and fixing of two modules steeped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required DSR-18, Item code-1.25
Supply and fixing of 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connections etc. as required DSR-18, item Code- 1.33
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a.) 6 way, Double door DSR-18, Item Code- 2.3.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole. DSR-18, Item code - 2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole. DSR-18, Item code - 2.10.3
Supply of TP MCB 32 Amps Make - L&T/ Schnieder/ Havells/DJB Approved
Supply of TP MCB 63 Amps Make - L&T/ Schnieder/ Havells/ DJB Approved
Supply of TP MCCB 100 Amps, 16KA Make - L&T/ Schnieder/ Havells/ DJBApproved
Supply of FRLS PVC insulated single core copper conductor of 1.5 Sq.mm Make - Polycab/ Havells/ Any other DJB Approved Length 90 meter
Supply of FRLS PVC insulated single core copper conductor of 2.5 Sq.mm Make - Polycab/ Havells/ Any other DJB Approved Length 90 meter
Supply of FRLS PVC insulated single core copper conductor of 4 Sq.mm Make - Polycab/ Havells/ Any other DJB Approved Length 90 meter
Providing of LED street light of 45 watt complete IP66 protection and impact resistance of 1K07 Make:- Havells/ Bajaj/Crompton/Phillips/wipro.
Providing of 2X 10 Sq mm PVC insulated and PVC sheathed Aluminum armored cable.Make :- Universal/ Standard/ Havells DJB approved
Supply of pole mounted cable junction box of size having IP 65 protection with complete accessories as per site requirement.Make:- sintex/ Hensel/DJB approved.
Supply and fixing if 32mm dia. 02 Mtrs. long G.I pipe (medium class) bracket for mounting of fluorescent/ HPMV/HPSV street light fitting on pole/ wall including bending the pipe to the required shape, 2 Nos. 40mmX3mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. DSR-18, Item code- 12.34
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as reqd. (clamped with 1mm thick saddle) 2x 10 sq. mm DSR-18, Item code-7.7.1
Fixing of control junction box with the help of nut, bolts, washers, fasteners etc. as per site requirement.
Dismantling of old/ defective/ non- functional wiring and fixture etc. complete in all respect as per site requirement.
HARI ELECTRICAL CO.
Premier Engineering Company
Gupta Brothers
Goodwill Enterprises
HYDROCON ENGINEERS
Cantilever Engineers
GOGIA BROTHERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .