Loading…
Loading…
Tender Value
₹3.0 Cr
EMD Value
₹3.0 L
Closing Date
1 Apr 2026, 6:10 pmClosed
Office of The Executive Engineer, Panchayat (R&B) Division, Chhotaudepur
Construction of Various Road Under MMGSY (Trible) in Kawant Taluka Dist. :- Chhotaudepur Pkg. No. 2025-26/68
289379
14 of 2025-26
Open
Civil Works - Roads
Works
Chhotaudepur
₹3,600
Executive Engineer, Panchayat (R&B) Division, Chhotaudepur
₹3.0 L
24 Mar 2026
24 Mar 2026
24 Mar 2026
1 Apr 2026
24 Mar 2026
Name Of Work :- Construction of Various Road Under MMGSY (Trible) in Kawant Taluka Dist. :- Chhotaudepur Pkg. No. 2025-
Taluka :Kawant District : Chhotaudepur
SCHEDULE FOR TESTING OF MATERIALS
For ensuring quality control and workmanship, various tests prescribed below for materials shall be taken at periodical intervals as stipulated below.
The material should be tested in GERI or Private laboratory approved by Govt. of Gujarat. Bill for testing charges should be paid Govt.
Item No. as Brief Description of materials to be Qty. of Unit Prescription of test which Frequency @ which test shall be Total Nos of
per tested. Materials shall be carried out carried out test to be
Schedule 'B' taken
1 45 to 90 MC.Metal Cum *Gradation test 1 to 100 - cum. 1 test
*Impact Value 100 to 500 - cum. 3 test
*Flakiness Index of 500 to 1500 - cum. 5 test
2 40 to 63 M.C.Metal 836.11 Cum *Gradation test 1 to 100 - cum. 1 test
*Impact Value 100 to 500 - cum. 3 test
*Flakiness Index of 500 to 1500 - cum. 5 test
1500 to 5000 - cum. 7 test
3 25 to 40 M.C.Metal 2005.25 Cum *Gradation test 1 to 100 - cum. 1 test
*Impact Value 100 to 500 - cum. 3 test
*Flakiness Index of 500 to 1500 - cum. 5 test
1500 to 5000 - cum. 7 test
4 Kapchi 20 mm Nominal 4582.52 Cum *Gradation test 1 to 100 - cum. 1 test
*Impact Value 100 to 500 - cum. 3 test
*Flakiness Index of 500 to 1500 - cum. 5 test
1500 to 5000 - cum. 7 test
5 Grit (6 mm) 251.90 Cum *Gradation test 1 to 100 - cum. 1 test
*Impact Value 100 to 500 - cum. 3 test
*Flakiness Index of 500 to 1500 - cum. 5 test
1500 to 5000 - cum. 7 test
6 Grit as Key aggregate (12 mm) 105.77 Cum *Gradation test 1 to 100 - cum. 1 test
*Impact Value 100 to 500 - cum. 3 test
*Flakiness Index of 500 to 1500 - cum. 5 test
1500 to 5000 - cum. 7 test
02. Sch B_MMGSY_ Chhota._Pkg_68
Item No. as Brief Description of materials to be Qty. of Unit Prescription of test which Frequency @ which test shall be Total Nos of
per tested. Materials shall be carried out carried out test to be
Schedule 'B' taken
7 Supplying of Quarryspall 262.16 Cum *Gradation,CBR One test per work
8 Supplying of Sand/ 1222.00 Cum *Silt Content,F.M One test per work
9 Stonedust 799.20 Cum *Gradation One test per work
10 Sel;ected Soil for Embankment 10521.00 Cum P.I ,CBR,MDB
11 Rubble 0.00 Cum *Density & Los Angeles abrasion As per IRC:SP:116-2018
12 Asphalt (VG-30) 38.30 M.T. Viscosity Test Tanker test in Geri Lab. Only
as per I.S. 1206 Up to 10
Above 50 one per Tanker
Ductility Test As per I.S.
Specification Gravity test As per I.S.
Softening point test As per I.S.
Quality of binder test 3 test per 2 tankers on plant site.
13 Tack Coat *Binder Temperature for applicationIrregular close in intervals
*Rate of spread of Binder. 2 test per Day.
14 Carpet & Seal Coat. Mix Grading One Test on Individual
Temperature of binder in Boilor Constituents and mixed aggregates from the
aggregates in the dryer and mix dryer for each 100 tonnes of mix subject to
at the time of laying and rolling. minimum of Two tests per plant per day.
( Binder content vide 45/MD. One Test for each 100 tones of mix
2172) subjects to minimum of two per Day.
Rate of Spreaded mix materials. Regular control through checks on layer
15 Cement (OPC) 827.700 M.T. *Consistency,Soundness 1 test @ 50.0 M.T. 100 T 2 tests,
*Setting time,Finessness Test 200 T 3 tests, 300 T 4 tests, 500 T 5 tests,
02. Sch B_MMGSY_ Chhota._Pkg_68
Item No. as Brief Description of materials to be Qty. of Unit Prescription of test which Frequency @ which test shall be Total Nos of
per tested. Materials shall be carried out carried out test to be
Schedule 'B' taken
*Compressive Strength. 800 T 6 tests, 1300 T 7 tests & 8 testd for
large consingment.
16 Steel (TMT) 13.34 M.T. *Tensile, (TMT) As per Manual of Quality Control
Yield 1 test/40 tonnes / per category
17 C.C.Cube Test 1:2:4 *Compressive Strength. 1 to 5 cmt - 1 No
M250 278.76 51 to above - 4 +1 additional sample
for each 50 cu.mt. Or part there of.
18 Retro Reflective Sheeting for the signage 86.00 Nos. as per Test schedule attached GR SOR/1018/715/Part file/C-1 Dtd.4/6/19
19 Road studs / Cat Eyes 235.00 Nos. as per Test schedule attached GR SOR/1018/715/Part file/C-1 Dtd.4/6/19
20 Hot Applied Thermoplast Road Marking 581.00 Sqmt as per Test schedule attached GR SOR/1018/715/Part file/C-1 Dtd.4/6/19
Note (1):- In case of excess in quantity. Further more test shall be carried out as per required frequency.
Note (2):- Apart from above listed materials for carrying out various tests during Road / Structure
Construction Works , if any other than above mentioned material/s are to be used during road /
structure construction work then it must be tested as per prevailing criteria of Govt. of Gujarat (R &
B Deptt.) and necessary tests should be carried out as per prevailing norms.
Signature of Contractor. Deputy Executive Engineer Executive Engineer
Panchayat (R & B) Sub Division Panchayat (R & B) Division
Chhotaudepur Chhotaudepur
02. Sch B_MMGSY_ Chhota._Pkg_68
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SBD_MMGSY _Chhota._Pkg.68.pdf
Bill of Quantities.pdf
INDEX OF SPECIFICATION.pdf
SCHEDULE FOR TESTING OF MATERIALS.pdf
5 years Special condition Contract.pdf
Drawing 1.pdf
Drawing 2.pdf
MMGSY ENVIRONMENT GR.PDF
GRs - SBD with Index.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .