Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC N A | L1 | Accepted-AOC Accepted | |
| 2 | L2₹34.8 L+₹2.5 L (7.80%)Rejected-AOC HIMACHAL PRADESH | L2 | Rejected-AOC Rejected | |
| 3 | L3₹37.5 L+₹5.2 L (16.0%)Rejected-AOC HIMACHAL PRADESH HP | MANDI | HIMACHAL PRADESH | 175047 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹37.6 L+₹5.3 L (16.5%)Rejected-AOC HIMACHAL PRADESH HP | MANDI | HIMACHAL PRADESH | 175001 | L4 | Rejected-AOC Rejected | |
| 5 | Not Admitted-Fee/PreQual/Technical HOUSE NO 136 RAURA SECTOR II BILASPUR DISTT BILASPUR H P 174001 | BILASPUR | HIMACHAL PRADESH | 174001 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹43.1 L
EMD Value
₹86,195
Closing Date
18 Aug 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE HIMUDA DIVISION MAND
EE HIMUDA DIVISION MAND
Govt Sr Sec School Behna Jattan Distt Bilaspur HP SH Construction of Class rooms
2023_HIMUD_77350_1
HIMUDA-MD-E-159-2023
Open Tender
Civil Works
Item Rate
180 days
Behna Jattan
Please refer to tender documents
8 documents required · 8 mandatory
₹1,770
₹86,195
15 Sept 2023
9 Aug 2023
19 Aug 2023
10 Aug 2023
18 Aug 2023
10 Aug 2023
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil all lead and lifts as directed by the Engineer-in- charge. All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size) including carriage of material in all leads and lifts.
Providing and laying mechanically mixed and vibrated design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Add for using extra cement in the items of design mix over and above the specified cement content therein. Note:- Excess/less cement over the specified cement content used is payable /recoverable separately. Extra for providing richer mixes at all floor levels. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately) including carriage of material in all leads and lifts.
All works upto plinth level
All works above plinth level upto floor V level
Centering and shuttering including strutting, propping etc. and removal of form for : including carriage of material in all leads and lifts.
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral staircases
Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards.
Edges of slabs and breaks in floors and walls Under 20 cm wide
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more including carriage of material in all leads and lifts.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more including carriage of material in all leads and lifts.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) including carriage of material in all leads and lifts
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) including carriage of material in all leads and lifts.
Providing and fixing pressed steel door frame sconforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm,or base ties of mild steel welded or rigidly fixed together by mechanical means, including M.S.pressed butt hinges 2.5 mm thick with mortar guards,locl strikeplate and shock absorbers as specfied and applying a coat of approved steel primer after pre-treatment of the surface as directed by the Engineer -in -charge thickness,including hinges jamb,lock jamb,bead and if required angle threshold of mild steel an
Profile B
Profile C
Profile E
Providing and fixing flush door shutters decorative type core of block board construction with frames of first class hard wood and well matched first class indian teak plyveneering with vertical grains or cross bends and face vencering on both faces of shutter including carriage of material in all leads and lifts. (a) 40mm thick including black enamelled M.S. butt hinges.
Providing and fixing 40mm thick single/double leaf glazed window shutter made of Hollock wood having style and top rail and bottom rail 75mm width and chamferred edged moulding 20X12mm for glass panes complete including bright finished balck enamelled iron hinges with necessary screws including carriage of material in all leads and lifts.
Providing and fixing Hollock wood 40 mm thick wire gauge shutters using galvanised MS wire gauge of IS gauge designation 85G. with wire of dia 0.56 mm for doors windows and providing and fixing Hollock wood chamfered edged beading of 20 x 12 mm including bright finished black enemelled iron hinges with necessary screws complete as per drawing and specification & as per instruction of Engineer-in-Charge. including carriage of material in all leads and lifts.
Providing & fixing glass panes with putty and nails in doors, windows, clerestory windows, all complete with : 5.50 mm thick glass panes including carriage of material in all leads and lifts.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete fixed to steel /wood windows by welding including carriage of material in all leads and lifts.
Providing and fixing stainless steel power coated sliding door bolts of required color and shade with bolts and nuts, screws etc complete including carriage of material in all leads and lifts.
Providing and fixing stainless steel power coated tower bolts (barrel type) of required shade and colour with screws, etc. complete including carriage of material in all leads and lifts.
Providing and fixing stainless steel power coated handles to required colour and shade with necessary screws, etc. complete including carriage of material in all leads and lifts.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete including carriage of material in all leads and lifts. (a) Twin rubber stopper.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required including carriage of material in all leads and lifts.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Kota stone slab flooring 20 mm (average) thick base of cement mortor 1:4 (1 cement :4 sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab. in single piece Including rubbing and polishing complete.i/c carriage of material in all leads and lifts:- 25 mm thick.
Kota stone slab 25 mm thick in risers of steps,skirting dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement :3 sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs including rubbing and polishing complete.including carriage of material in all leads and lifts
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. including carriage of material in all leads and lifts. Size of Tile 600x600 mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. including carriage of material in all leads and lifts. Size of Tile 600x600 mm
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes including carriage of material in all leads and lifts 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion including carriage of material in all leads and lifts
Shoe (Plain) 110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.including carriage of material in all leads and lifts:-110 mm diameter
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required including carriage of material in all leads & lifts.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 1518 microns using self drilling/ self tapping screws complete including carriage of material in all leads & lifts.
Ridges plain (500 - 600mm)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) including carriage of material in all leads and lifts
CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster of mix Cement mortar 1 : 6 (1 cement : 6 fine sand) including carriage of material in all leads and lifts
CEMENT PLASTER (IN FINE SAND) 20 mm cement plaster of mix Cement mortar 1 : 6 (1 cement : 6 fine sand) including carriage of material in all leads and lifts
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade new work (two or more coats) over and including water thinnable priming coat with cement primer including carriage of material in all leads and lifts.
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm i/c carriage of material in all leads & lifts
Applying priming coat with ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including carriage of material in all leads and lifts
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications (a) Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture including carriage of material in all leads and lifts.
Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including carriage of material in all leads and lifts
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications (a) Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture including carriage of material in all leads and lifts.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth including carriage of material in all leads and lifts.
Constructing Course rubble hammer dressed 'U' shape open surface drain with side wall.15x22 cm in cement mortar 1:6 (1 Cement : 6 Sand) and inside plastring with cement plaster 1:3 (1 Cement:3 Sand) including earth work and laying 10 cm cement concrete in 1:5:10 (1 Cement : 5 Sand : 10 graded stone aggregate) of 40 mm nominal size) and 7.5 cm cement concrete 1:2:4 (1 Cement : 2 Sand : 4 Graded stone aggregate of 20 mm nominal size) and finished with a floating coat of neat cement complete as per standard design.) including carriage of material in all leads and lifts.
Boulder filling dry hand packed tightlyunder floor . including carriage of material in all leads and lifts.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete including carriage of material in all leads and lifts.
Making khurras 45x45 cm with average minimum thickness of 5 cm, cement concrete 1:2:4 (1cement:2sand:4stone aggregate of 20mm nominal size) finished with 12mm cement plaster 1:3 (1cement:3sand) and coat of neat cement rounding the outlet complete including carriage of material in all leads and lifts.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete including carriage of material in all leads and lifts.(a) 40 mm thick with 20 mm nominal size stone aggregate.
Applying a coat of hot bitumen (mexphalt 80/100 or equivalent) using 1.70 kg. per square metre on damp proof course after cleaning the surface with a piece of cloth lightly soaked with kerosene oil including carriage of material in all leads & lifts.
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand) including carriage of material in all leads and lifts.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete including carriage of material in all leads and lifts.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections including carriage of material in all leds and lifts.
Sada Nand
Satish Kumar
Ranjeet Thakur
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .