Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹24.0 L+₹7,355.90 (0.31%)Rejected-Finance 695 NEAR ANJALI CLINIC SHIV PALACE SHANTI VIHAR BADAUN ROAD SUBHASH NAGAR BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | L2 | Rejected-Finance Rejected being higher than L1. | |
| 3 | L3₹27.3 L+₹3.3 L (13.9%)Rejected-Finance 578 AVAS VIKAS JANAKPURI B IZATNAGAR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | L3 | Rejected-Finance Rejected being higher than L1. | |
| 4 | L4₹30.5 L+₹6.5 L (27.3%)Rejected-Finance NEAR ANAJ MANDI SUBHASH NAGAR BAREILLY 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L4 | Rejected-Finance Rejected being higher than L1. |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
28 Sept 2024, 6:00 pmClosed
GE (West) Bareilly
GE (West) Bareilly
REPAIR TO DRAIN, CULVERT FENCING, GATE PATH, HARD STANDING AND BOUNDARY WALL/ COMPOUND WALL AND REPAIR/REPLACEMENT OF SEWAGE LINE, MH, SEPTIC TANK AND SOAK PIT ETC AT CERTAIN LOCATIONS OF ZONE II AND III UNDER GE (W) BAREILLY.
2024_MES_670293_1
8209/C/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Bareilly
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (West) Bareilly
₹96,000
Yes
29 Nov 2024
2 Sept 2024
30 Sept 2024
2 Sept 2024
28 Sept 2024
16 Sept 2024
Amount
M&L for cleaning /function of existing sewage system consisting of SGSW pipes, RCC hume pipes , CI pipes and PVC pipes of any dia at any depth, manholes of different sizes and depth of different size and capacity, waste and vent pipes fixed on walls, nahani/floor trap inside the bldgs,and gully trap outsides the bldgs etc incl removal of all blockage in the system, dewatering and desludging manholes by using honey sucking machine/ mechanical sewage suction pump and removal of sludge in covered vehicles outside the MD land all as specified and directed by Engr-in-charge. The unit rate quoted shall deemed to inclusive of the followings
(i) Contractor has to engage Four safaiwala and one supervisor with mobile phones having no photo facility. The team must be reported in the complaint cell/ sub div in proper uniform and with all necessary T&P such as green female bamboo strips, iron rods, sewage rodding machine, buckets, rope, ladder, safety mask, etc for execution of the item. The quoted rate shall also be included the cost of conveyance of workers, supervisors, materials and T&P. (ii) Team of workers with T&P shall be attanded the complaints of the entire area as directed by Engr-in-charge and the completion of work shall be reported by 05:00 PM of every working day.
(iii) Team of workers with T&P shall be attanded the complaints of the entire area as directed by Engr-in-charge and the completion of work shall be reported by 05:00 PM of every working day. (iv) Attendance register shall be maintained by Engr-in-charge at sub divn/ complaint cell. In case of absence of workers a penal recovery of Rs 500 per day per worker shall be imposed on contractor. (v) A complaint register shall be maintained by JE and proper record of compliants received and attended with date and time shall be recorded and shall be signed daily by both the parties. Complaint register shall be kept on record of Engr-in-Charge after completion of work.
(vi) Complaints of blockage of sewage line/ manhole/ nahani trap if an attended within 24 hours after issuance of compliant slips or telephonic directional a penalty of Rs 300/- per each complaint shall be imposed on contractor. (vii) GE/Engr-in-charge will have no liability to give permanency of the employment of workers. A certificate in this regard will be rendered by contractor prior to the commencement of the work. (viii) Payment to the workers shall be properly receipted. A certificate shall be produced by the contractor that the every employee engaged by him have been paid their wage in full.
(ix) Contractor will not permitted to engage child labour in the work. (x) Contractor shall provide uniform with name plate as approved by Engr-in-charge to the workers. (xi) Supervison shall be obtained necessary directions from JE/Engr-in-charge and supervise the workers. (xii) Each worker shall be submitted affidavit in stamp paper duly notary that he will not claim employment from department. (xiii) Contractor shall submit accident /risk insurance policy of each worker engaged in cleaning sewage system.
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 m in depth, getting out in soft/loose soil etc., including trimming bottom and sides of trenches, leveling/grading and ramming bottom of excavation complete all as specified and directed
Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil, complete all as specified and directed.
Removing surplus excaveted soil to a distance exc 250 Mtr and nexc 500 Mtr depositing where directed at a level n. exc 1.5 Mtr above the starting point complete all as specified and directed.
Surface dressing in soft/ loose soil incl cleaning the area, bushes,, shrubs etc and removing upto 50 distatance, complete all as specified and directed.
M&L for spraying of weed remover Herbicide Round Up chemical to burn the vegitation as per manufacturer instructions and removing the waste to a distance not exc 50 mtr.
Pumping out of water/liquid/sludge/any other waste/materials stagnated in septic tank/soak wells and discharge the same to nallah/drains through hose pipe upto distance of 250mtr, complete all as specified and directed by Engr -in - Charge.
Cleaning of septic tank /manholes of any depth/area/condition including taking out all the stagnated sludge or any other material mixed with the sludge etc complete and disposal of all spoils/waste or any other materials upto a distance exc 200 mtrs but n.exc 500 mtrs complete all as specified and directed by Engr -in - Charge.
Demolition and breaking up drain pipes (salt glazed ware, AC or Reinforced) 150 mm dia set in cement mortar complete all as specified and directed by Engr -in - Charge.
All as Srl Item No 9 above but 200mm bore complete all as specified and directed.
M&L for 150 mm bore reinforced concrete pipes class N P-2, laid and jointed complete with collars layring over concrete bed for 150mm in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) to drain pipes including packing under,haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engr -in - Charge.
M&L for 200 mm bore reinforced concrete pipes class N P-2, laid and jointed laying over concrete bed for 200mm in PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) to drain pipes including packing under,haunching against the sides of pipes after they are laid and tested complete with collars complete all as specified and directed by Engr -in - Charge.
Cutting into existing manholes for connecting new drains making good to open and rendering, cutting out existing benching for and forming branch channel 1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1,smooth finished and reforming benching
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation bed of manhole, drains and steel post embeded etc complete all as specified and directed by Engr -in - Charge.
M&L for PCC 1:2:4 type B-1(using 20 mm graded stone aggregate) as in channels/benching of manhole, laid to shape and slope and surfaces finished even and smooth using extra cement, complete including all form work etc complete all as specified and directed by Engr -in - Charge.
M&L rendering 15 mm thick on fair faces of brick (internal faces of manholes ST in CM 1:4 mixed with water proofing compouind where ever required in proportion as per manufacturer"s instructions, including finishing the surfaces even & smooth without using extra cement complete all as specified and directed by Engr -in - Charge
Supply only integral water proofing compound (powder). complete all as specified and directed by Engr -in - Charge
M & L proving pre cast reinforced cement concrete type B1 1:2:4 (using 20mm graded stone aggregate) as in landing cover slab for man holes chullah hoods chajjas water toughs manger shelves and similar articles with plain faces setting in CM (1:6) including demolition of old slab complete all as specified and directed by Engr -in - Charge. Note size as specified by engr -in-chage
M&L providing pre cast reinforced cemnent concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in precast RCC manhole / septic tanks covers including all form work and setting in CM 1:4 including demolition old cover all complete all as specified and directed by Engr -in - Charge Note size as specied by engri-in- charge
Supply and fix TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) but not less than 0.9 mm dia conforming to Fe-410 - 0, complete all as specified and directed by Engr -in - Charge
Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, aches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed by Engr -in - Charge
M & L brick work with sub class B bricks, straight or curved on plan exc 6m mean radious built in CM (1:6) etc complete all as specified and directed by Engr -in - Charge
M & L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engr -in - Charge
M & L brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in built in CM (1:6) etc complete all as specified and directed by Engr -in - Charge
Labour only for brickwork with except brick straight or curved on plan exc 6m mean radius built in in CM (1:6) etc complete all as specified and directed by Engr -in - Charge
Taking down cement or cement lime plaster any description on brick walls etc. including racking out joints hacking for keys scrubbing down with water complete all as specified and directed by Engr -in - Charge
M&L rendering 15 mm thick in CM 1:4 on brick work (other than fair faces)including finishing the surface fair and even without using extra cement complete all as specified and directed by Engr -in - Charge
M&L 15mm thick cement plaster on brick surfaces or concrete surfaces in cm (1:6) including finishing the surface even and smooth without using extra cement complete all as specified and directed by Engr -in - Charge
M&L 15mm thick cement plaster on brick surfaces or concrete surfaces in narrow width, patches, jambs, cornices, bands etc n exc 3 Sqm each in cm (1:4) including finishing the surface even and fair complete all as specified and directed by Engr -in - Charge
M & L applying two coats of cement based paint on newly plastered or unplastered wall surface including preparation of surfaces, complete all as specified and directed by Engr -in - Charge
Excavation in Post holes (or similar holes ) in any type of soil, each not exe 0.5 cum , getting out , returning filling and ramming carts not exc 25cm , watering and removing surplus soil to a distance not exc 50 mtr and making good surface complete all as specified and directed by Engr -in - Charge
Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground, embedded with concrete etc complete all as specified and directed by Engr -in - Charge
Fixing only chain link fencing including line wires any mesh, size and type to any type of standards, rails, straining bolt, etc including provision of binding wire complete all as specified and directed by Engr -in - Charge
Dismantling of old barbed wire fencing complete all as specified and directed by Engineer-in-Charge.
S&F in repairs galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing and straining and fixing to any type standard rails, staining bolts incl securing, tying at crossing with and provision of galvanized steel wire staple or steel pins etc complete all as specified and directed by Engr -in - Charge (Each line to be measured)
Supply only chain link MS galvanised fencing any size or type complete all as specified and directed by Engr -in - Charge
S&F M S Posts and struts in fencing (any size of angle) mm including cutting tops to shapes as directed including driling holes for bolting of MS flat iron in horizontal, vertical & diagnal faces of each pannel to be intertwined with Chain link fencing, and fixed to posts with MS nut bolts of exc 5 cm n exc 10 cm in lenth and 10-15 mm dia and washers ,wind ties for sign board posts and struts, MS round bars and similar work confirming to Fe 290 Gde E-165 complete all as specified and directed by Engr -in - Charge
S&F mild steel TMT bars 10mm dia or over cut to length , bent to shape required, including cranking, bending spirally for hooping columns, hooking ends and binding with and including M.S wire (annealed) n.less than 0.9mm dia or securing with clips complete all as specified and directed by Engr -in - Charge
M & L for reinforced cement concrete M-25 (20 mm graded) for culvert, foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engr -in - Charge
Formwork to sides of Rough finished surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed by Engr -in - Charge
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and fastening and fixing complete FE 290 Gde E-165 complete all as specified and directed by Engr -in - Charge
S&F Welded steel wire fabric weight n exc 4 kg/sqm supplied and fixed complete to wood or steel members complete all as specified and directed by Engr -in - Charge
Taking down steel gates any type and size. complete all as specified and directed by Engr -in - Charge
M&L for painting to new steel surface exc 10 cm width or girth with two coats of synethic enamel paint over a coat of red oxide primer including preparation of newly or previously untreated surface all as spd and directed
Removal of excess earth , waste materials already dumped at site incl. Necessary excavation, upto 250 mtrs distance wherever reqd. complete all as specified and directed by Engr -in - Charge
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr -in - Charge
Demolition of reinforced Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr -in - Charge
Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr -in - Charge
M&L Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed by Engr -in - Charge
M&L for Machine pressed cement concrete factory made coloured glazed interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, M-35 Grade, machine pressed of pattern and colour as approved by GE over 75 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base floor / pavings complete all as specified and directed by Engr -in - Charge
M&L for Machine pressed cement concrete factory made coloured glazed interlocking paver block any shape and size confirming to IS 15658 -2006 of 80 mm thickness, M-40 Grade, machine pressed of pattern and colour as approved by GE over 75 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base floor / pavings complete all as specified and directed.
M&L for PCC (1:2:4) type B1 using 20mm graded agg for machine pressesd precast cement concrete kerb stone including weathering, slightly rounded or chemferred angles and throating , as directed edges complete including excavavtion for kerb stone and filling after embeded including watering and well ramming as spd and directed by engr-in charge. Note size is approved by GE.
M&L for coloured glazed polished chequered cement concrete 30cm x 30cm x 25mm thick With mixture of grey and white cement in equal proportions and no pigment set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over screed bed or bedding layer of mortar, 20 mm thick, in cement mortar 1:6, for laying floor finishes, laying over 25 mm thick PCC 1:2:4 type B0, using 12.5mm graded aggregate as in floors complete all as specified and directed.
S&F in repair fiber sheets 1.5 mm thick of any colour having high tensile strength fixed with existing chain link fencing or on post with self screw and nut bolts all necessary fittings complete all as specified and directed. Note : Sheet colour shall be approved by GE
M & L for Steel work in tubular hollow section of framing for fiber sheets, rail including special shaped washer etc complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 (using 20 mm graded stone aggregrate) mass concrete as in complete all as spd as directed
M & L Formwork to sides of Rough finished surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
M&L for Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required, area exc 150 but not exc 400 Sqcm.
M & L Extra for forming fair finished drain or channels 30 cm inner girth in cement concrete using extra cement including form works, moulds, mitred/stopped and etc complete all as specified and directed.
M & L for construction of brick masonry soak well of 2.40 m internal dia and 3.00 m effective depth including all excavation and earth work, PCC work, honey combed and solid brick work, RCC work, PCC band, filling with brick bats etc. complete all as specified, directed and shown on drawings No. TD – 309 sheet 1 / 4 to 4 / 4.
Notes:- Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
SURYA CONSTRUCTION (BID ID -3099891)
UTTRAKHAND BUILDERS (BID ID -3105064)
vipul nagaich (BID ID -3102730)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .