| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹5.0 LAdmitted-Finance | -15.01% | ₹5.0 L | L1 | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹5.9 L
EMD Value
₹11,760
Closing Date
3 Mar 2026, 3:00 pmClosed
Executive Engineer PWD Elect Division II Jodhpur
Executive Engineer PWD Elect Division II Jodhpur
SITC of Audio system at Centralized library hall at District and session Court(Metro) District Jodhpur
2026_CEPWD_542684_2
NIT No.53 of 2025-26 of E.E. PWD Elect.Dn.II Jodhpur
Open Tender
Electrical Works
30 days
Jodhpur
SITC of Audio system at Centralized library hall at District and session Court(Metro) District Jodhpur
3 documents required · 3 mandatory
₹500
Executive Engineer PWD Elect Division II Jodhpur
₹11,760
Yes
17 Mar 2026
27 Feb 2026
3 Mar 2026
27 Feb 2026
3 Mar 2026
27 Feb 2026
Supply, Installation, Testing & Commissioning of Chairman Unit with fixed microphone and flexible stem prority button for chairman microphone ,optioal chime tone facility for proceeding chairman announcement with two headphone socket built in loudspeaker is automatcally muted when the microphone is on/off button chairman mike unit should have a frequency responce 400hz to10hz ,length of microphone from base to steam should not be less than 488 mm in size ;nominal acoustic input 85 db SPL,dimensions (without microphone) (HxWxD) 50x135x135 mm; weight of unit should not be less then 1.2 kg ;operating temperature -5°C to +45°C,two 3.5mm (0.14 in) stereo headphone sockets; including make connecion testing etc complete as required.
supply, Installation, Testing & Commissioning of Delegate mike Unit with fixed microphone and flexible stem prority button for Deligate mike microphone ,optioal chime tone facility for proceeding Delegate mike announcement with two headphone socket built in loudspeaker is automatcally muted when the microphone is on/off button Delegate mike unit should have a frequency responce 400hz to10hz ,length of microphone from base to steam should not be less than 488 mm in size ;nominal acoustic input 85 db SPL,dimensions (without microphone) (HxWxD) 50x135x135 mm; weight of unit should not be less then 1.2 kg ;operating temperature -5°C to +45°C,two 3.5mm (0.14 in) stereo headphone sockets; including make connecion testing etc complete as required.
Supply & Installation of 240 Watt Mixer Amplifier Unit- for providing a crisp call or clear music with 4 microphone / line inputs, plus music source input, announcement only output, 3 wire volume override, with Mains power supply 230 VAC ±10%, 50 Hz (reduced power at lower mains), Inrush current 20 A , Power consumption 120W, Frequency response (Line) 80 Hz to 18 kHz (+1/‑3 dB @‑10 dB ref. rated output) Frequency response (Mic.) 80 Hz to 18 kHz (+1/‑3 dB @‑10 dB ref. rated output) Distortion <1%@ rated output power, 1 kHz Bass Control Max. ± 8 dB Treble Control Max. ± 8 dB, including making connection etc complete as required.
Supply& laying of 8 core shielded cable for extension cable for contribution unit /control unit interconnection making connection testing etc complete as required.
Supply, Installation, Testing & Commissioning of High−performance 15 meter HDMI male to HDMI male cable Wall plate for the interoperability in all respect to etc complete as required.
Supply and laying speaker cable of ollowing size 2 core twin twisted multi stranded electrolytic grade copper conductor, overall PVC insulated and armoured cable (Blue colour) on surface/ above false ceiling including cost of GI spacers, saddles etc. as required.
Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.
On board
S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required.
S&F following sizes of ISI marked ( IS:14927 P - II ) uPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners etc. as required.
20 mm x 12 mm
25 mm x 12 mm
Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required.
3x 1.5 sq.mm
2 x 2.5 sq. mm. + 1x1.5sqmm
2 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_967380.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.58 MB
Tendernotice_2.pdf
PDF • 0.28 MB
Tendernotice_3.pdf
PDF • 0.14 MB
Tendernotice_4.pdf
PDF • 0.59 MB
BOQ_967380.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid