Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹6.8 L+₹1.7 L (33.7%)Rejected-Finance JANAKI NIVAS BEHIND CHOVVA TEMPLE CHOVVA PO KANNUR KERALA 670006 | KANNUR | KANNUR | KERALA | 670006 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹8.1 L+₹3.1 L (60.4%)Rejected-Finance 137 D THEJAS BURNASHERRY KANNUR KERALA 670013 | KANNUR | KANNUR | KERALA | 670013 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹8.5 L+₹3.5 L (68.7%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L4 | Rejected-Finance Not being L1 |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
4 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum- 695006
REPAIR/REPLACEMENT OF OLD DEFECTIVE INTERNAL WIRING, LIGHT FITTINGS, DBS INCLUDING CONNECTED ITEMS AND CERTAIN ALLIED WORKS AT PAO BLDG AND PAYYAMBALAM QTRS OF PAO (OR) DSC KANNUR UNDER GE (ARMY) TRIVANDRUM
2024_MES_678092_1
8205/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kannur
As per tender documents
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹18,000
Yes
13 Dec 2024
4 Oct 2024
11 Nov 2024
4 Oct 2024
4 Nov 2024
18 Oct 2024
4 Oct 2024 - 11 Oct 2024
Amount
Taking down old existing point wiring including switch and sockets carefully aluminium, light, fan, socket or power point complete including unserviceable fittings such as switches ceiling roses, pendants, regulators, sockets of any type etc at site and making good the disturbed surfaces of walls, floors filling up of holes, plastering white washing distempering etc matching to the existing etc. complete all as specified and directed.
M&L for point wiring complete for one light point controlled by one way switch with 1.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade with multistranded, copper conductor and drawing in and including non metallic rigid PVC concealed conduit medium grade inclusive of conduit fittings such as Bends, Tees, reducers etc and galvanized iron sheet steel terminal boxes of size 16 gauge thickness, light switches sockets with 3mm thick bakelite laminated sheet brass screws and cup washers including one continuous run of 1.50 Sqmm nominal area solid conductor PVC insulated unsheathed 1100 Volts grade single core FRLS cable with solid copper conductor green in colour with wire and connecting to earth dolly complete all as specified and directed.
All as per SI item No. 2.00 here-in-before, but for one fan point controlled by one way switch complete all as specified and directed.
All as per SI item No. 2.00 here-in-before, but for one bell point controlled by one way switch complete all as specified and directed.
All as per SI item No. 2.00 here-in-before, One 3/5 pin 5 Amps socket outlet on independent board complete all as specified and directed.
All as per SI item No. 2.00 here-in-before, One 3/5 pin 5 Amps socket outlet on same board complete all as specified and directed.
All as per SI item No. 2.00 here-in-before, One light point controlled by two way switch complete all as specified and directed.
All as per SI item No. 2.00 here-in-before but with using copper conductor of 2.5 Sqmm for one 3/5 pin socket outlet 15 Amps on independent and using 2.5 Sqmm copper conductor as earth continuity cable compete all as specified and directed.
All as per SI item No. 2.00 here-in-before but with using copper conductor of 4.00 Sqmm for one 3/5 pin socket outlet 15 Amps on independent and using 4.00 Sqmm copper conductor as earth continuity cable compete all as specified and directed.
S&Fswitch piano, flush type single pole, one way 5/6 Amp complete all as specified and directed.
S&F Bell push, flush type, 5 Amp, single pole 230 volts one way complete all as specified and directed.
S&F switch flush type 5 Amps two way complete all as specified and directed.
S&F socket outlet with safety shutter 5 pin 5 Amps flush type all as specified and directed.
S&F switch piano flush type one way 15 Amps, Single Pole complete all as specified and directed
S&F socket outlet polycarbonate 2 in 1 , 3 pin 5 / 15 Amps flush type complete all as specified and directed.
S&F Bell Ding Dong musical AC 230 Volt complete all as specified and directed.
S&F for lamp holder insulated body of PVC / polycarbonate type with back plate suitable for Angle/ batten fittings complete all as specified and directed.
S&F ceiling rose 3 terminals PVC / Polycarbonate insulated body 65mmx 50mm size complete all as specified and directed.
S&F stepped type modular fan regulator, 120 watt, 2 Module complete all as specified and directed.
S&F in replacement of self ballast LED batten light fittings extruded thermoplastic body with PC diffuser > 120 degree wide distribution, 4 feet 20 W LED batten 4 feet 20 W, CCT 6500 K Complete including connection upto ceiling rose with flexible copper twin twisted wire complete and all as specified and directed
S&F in replacement of self ballast LED batten light fittings extruded thermoplastic body with PC diffuser > 120 degree wide distribution, 4 feet 18 W LED batten 4 feet 18 W, CCT 6500 K Complete including connection upto ceiling rose with flexible copper twin twisted wire complete and all as specified and directed.
S&F in replacement of self ballast LED batten light fittings extruded Al body with PC diffuser in unique square shape > 120 degree wide distribution, 2 feet 10 W of LED batten 2 feet 10 W, CCT 6500 K Complete including connection upto ceiling rose with flexible copper twin twisted wire complete and all as specified and directed.
S&F in replacement of self ballast LED batten light fittings extruded thermoplastic body with PC diffuser in unique square shape > 120 degree wide distribution, 2 feet 9 W of LED batten 2 feet 9 W, CCT 6500 K Complete including connection upto ceiling rose with flexible copper twin twisted wire complete and all as specified and directed.
S&F in replacement of LED light fitting 1x10 Watt bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete and all as specified and directed.
S&F in replacement of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F in replacement of Recessed/Surface mounting 36W LED luminaire, prewired with white powder coated CRCA housing with LEDs and fully window acrylic diffuser, suitable for 600x600mm E-grid/POP/ false ceiling complete with all accessories making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose/PVC connector to light fitting and testing etc complete all as specified and directed.
S&F in replacement submain wiring with using two single core 6.0 Sqmm copper multy stranded conductor PVC insulated and unsheathed (FRLS) cable and one single core 6.0 Sqmm copper multistandred conductor PVC insulated and unsheathed (FRLS) Earth wire using ISI Marked IS 694 1100 volts grade PVC insulated flexible stranded copper conductor wire drawn through with and including medium grade concealed PVC conduit ISI marked not less than 25 mm dia including conduit fitting and accessories complete including cutting cheses in existing wall of any description built in cement mortar and making good the disturbed surfaces in cement mortar (1:4) and finishing the surfaces to match with existing surfaces and finish termination with bottle type copper lugs conduit being laid either in ceiling slab or wall or on surfaces or under the frame of the false ceiling including PVC flexible conduit or through wooden partition including clamping arrangement as required complete all as specified and directed . Note:- Two Run of 6.0 Sqmm cable and one run of 6.0 sqmm earth wire in and including conduit of suitable size shall be measured as one unit.
S&F in replacement of MCB SP 6-32 Amps breaking capacity 10 KA 'B' series 240 volts 50 Hz complete all as specified and directed.
S&F in replacement of MCB SPN 40 to 63 Amps breaking capacity 10 KA 'B' series 240 volts 50 Hz complete all as specified and directed.
S&F in replacement of MCB TPN 63 Amps breaking capacity 10 KA 'B' series 415 volts 50 Hz complete all as specified and directed.
S&F in replacement of double door MCB distribution board with steel sheet powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral confirms to IS 13032- 1991 of 4 ways complete including and making good the disturbed surfaces of walls, floors filling up of holes, plastering, whitewashing/distempering etc matching to the existing all as specified and directed.
S&F in replacement of double door MCB distribution board with steel sheet powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral confirms to IS 13032- 1991 of 6 ways complete including and making good the disturbed surfaces of walls, floors filling up of holes, plastering, whitewashing/distempering etc matching to the existing all as specified and directed.
S&F in replacement of double door MCB distribution board with steel sheet powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase 240 volts and neutral confirms to IS 13032- 1991 of 8 Ways complete including and making good the disturbed surfaces of walls, floors filling up of holes, plastering, whitewashing/distempering etc matching to the existing all as specified and directed.
S&F in replacement of TPN sheet steel, distribution board, Double Door, 4 ways confirming to IS 13032-1991 complete including and making good the disturbed surfaces of walls, floors filling up of holes, plastering, whitewashing/distempering etc matching to the existing all as specified and directed.
S&F in replacement of LED Lamp 15 Watt complete all as specified and directed.
S&F Modular switch 1 way, 6 A, 1 module complete all as specified and directed.
S&F Modular switch 1 way, 16 A, 1 module complete all as specified and directed.
S&F Modular Socket 6A - 2/3 pin combined 2 module complete all as specified and directed.
S&F Modular socket 6A/16A - 2/3 pin combined, 2 module complete all as specified and directed.
S&F in replacement and providing new Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one double pole MCB of 20 Amp, 240 Volt complete all as specified and as directed.
M&L for Earthing complete with using GI earth plate electrode 600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using 4 mm dia GI Wire as earth lead moulded and retrieved to earth plate at one end and connected to main switch / control board at another end with and including 15 mm dia GI light grade from upper end of earth plate upto external face of the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B-1 (Using 20 mm Dia graded stone aggregate) duly reinforced with mild steel round bar 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handle with and including necessary excavation and earth work including laying the pipe concealed in floor / wall allas per plate No-3 of SSR Part-I complete all as specified and directed and testing on completion (Note:- If the desired resistance is not found earthing shall be re-done by the contractor at no extra cost to Govt) complete all as specified and directed.
T.P.SUNIL KUMAR (BID ID -3156984)
Benchmark Engineers and Contractors (BID ID -3157122)
SUPER COOL (BID ID -3153312)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .