Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC | ₹1.9 L | L1 | Accepted-AOC LOWEST BID ACCEPTED |
| 2 | L2₹2.0 LRejected-AOC | ₹2.0 L | L2 | Rejected-AOC NOT ACCEPTED |
| Sl No | Description | Qty | Unit | GIREESH C V L1 | E R ANANDAN L2 |
|---|---|---|---|---|---|
| 1.00Electrical work | |||||
| 1.00 | 90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point | 9 | point | 990.99 ₹8,918.91 | 1,008 ₹9,072 |
| 1.00 | OD220633/2025-2026:Supply and providing Desert Air Cooler 65Liters preferably Crompton optimus (amazon .in) fixing rigidly adjazent to wall using clips etc | 2 | no | 12,077.03 ₹24,154.06 | 12,284.33 ₹24,568.66 |
| 1.00 | OD220673/2025-2026:Supply and providing 1200mm efficiencia DX BLDC Ceiling fan , 5star rated double ball bearing (w/o remote) preferred bajaj/ Havells or equivaient reputed make. | 8 | no | 3,886.12 ₹31,088.96 | 3,952.83 ₹31,622.64 |
| 1.00 | OD220674/2025-2026:Supply ,Conveyance, installation Testing and Commissioning of 300 mm sweep Wall mounting fan (all metal construction) using mounting brackets supplied along with the fan and giving connections with the existing wire . | 8 | no | 1,837.27 ₹14,698.16 | 1,868.8 ₹14,950.40 |
| 1.00 | OD220637/2025-2026:Supply 36W, fixing and commissioning 2ft x 2ft Panel light with > 110lm/W CRCA Housing and PMA Diffuser ,THD <10% ; PF > 0.95 ,Model LCTLRNE -36- FO -CDL | 17 | each | 2,665.19 ₹45,308.23 | 2,710.93 ₹46,085.81 |
| 1.01 | OD223211/2025-2026:Supply and providing 18 W, LED, out door DOM Light fittings on compound wall piller top and giving connections with required length of 16/0.20 mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire etc as required. ( LUKER eco or equivalent make) | 2 | no | 1,390.81 ₹2,781.62 | 1,414.68 ₹2,829.36 |
| 1.01 | 90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG) | 26 | metre | 28.91 ₹751.66 | 29.4 ₹764.40 |
| 1.01 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) | 20 | metre | 44.44 ₹888.80 | 45.21 ₹904.20 |
| 1.01 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) | 18 | metre | 62.83 ₹1,130.94 | 63.91 ₹1,150.38 |
Tender Value
₹2.1 L
EMD Value
₹5,131
Closing Date
1 Sept 2025, 6:00 pmClosed
Sreekanth P S
Mala Block Panchayath Office , Mala , Kuruvilaseery , Thrissur Pin -680732
Block Panchayath Community hall Electrification (Project No 139/2025-26)
2025_CRD_788283_1
3915850-2025
Open Tender
Electrical Works
150 days
MALA BLOCK PANCHAYATH
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹5,131
Yes
20 Dec 2025
19 Aug 2025
3 Sept 2025
19 Aug 2025
1 Sept 2025
19 Aug 2025
Amount
Electrical work
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
OD220633/2025-2026:Supply and providing Desert Air Cooler 65Liters preferably Crompton optimus (amazon .in) fixing rigidly adjazent to wall using clips etc
OD220673/2025-2026:Supply and providing 1200mm efficiencia DX BLDC Ceiling fan , 5star rated double ball bearing (w/o remote) preferred bajaj/ Havells or equivaient reputed make.
OD220674/2025-2026:Supply ,Conveyance, installation Testing and Commissioning of 300 mm sweep Wall mounting fan (all metal construction) using mounting brackets supplied along with the fan and giving connections with the existing wire .
OD220637/2025-2026:Supply 36W, fixing and commissioning 2ft x 2ft Panel light with > 110lm/W CRCA Housing and PMA Diffuser ,THD <10% ; PF > 0.95 ,Model LCTLRNE -36- FO -CDL
OD223211/2025-2026:Supply and providing 18 W, LED, out door DOM Light fittings on compound wall piller top and giving connections with required length of 16/0.20 mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire etc as required. ( LUKER eco or equivalent make)
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
OD220640/2025-2026:Supply, Conveyance, Installing testing and commissioning 20W Flood light with Die cast aluminium housing
OD220638/2025-2026:Supply and providing the following sizes of bolt and nut with washers on the existing M.S box/ earth bus etc. as required including drilling necessary holes as required. 25x6mm brass nut and bolt .
OD220632/2025-2026:Supply and providing the following sizes of bolt and nut with washers on the existing M.S box/ earth bus etc. as required including drilling necessary holes as required. 25x3mm brass nut and bolt .
90.6.4.3:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 3 Run
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.2:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and netural
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
OD220634/2025-2026: Supply and errection of Glow Sign Board made of 3mm thick PVC foam board for each floor 12"x4" (Fire lift, Electrical duct, Fire station, Main stair, Fire Exit, Floor Display & pump room.
OD220672/2025-2026:Supply, Conveyance, Installing testing and commissioning 70W Flood light with Die cast aluminium housing and toughened glass > 110Lm/W ; potted driver, IP66; THD < 10% PF >0.95 , TFS- 504 - 70 - 57.
OD220675/2025-2026:Supply and installation of 63 A, 415V, 50Hz AC 23A 4 pole on load changeover switch in sheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement on existing angle iron frame work or directly to wall using necessary bolts and nuts, fixing the unit to wall making good the damages colour washing etc. including giving necessary connections as required.
OD220676/2025-2026:Painting letters or figures of the sizes 2.5 cm, 4 cm, 5cm height with enamel paint as identification mark to SB, DB, Panel board etc. as required
OD220677/2025-2026:Supply and fixing 63 A HRC fuse base with HRC fuse link in the existing meter board and giving connections etc.
OD220678/2025-2026:Supply and providing 2.00 mm thick 3.3 KV synthetic elastromeric fire retardant insulating sheet.
90.10.3.24:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )Step Fan regulator - type 2 M
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
1.43:Providing and fixing extra conduit down rod of 20 mm dia, 2X10 cm length wiring with 2 X1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
6.12:Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
E R ANANDAN (BID ID -2320382)
Bidder Name
E R ANANDAN
GIREESH C V
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1297411.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid