Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAdmitted-Finance FATEHPORA POSH BAGH BARAMULLA JAMMU KASHMIR 193101 UDYAM JK 03 0027297 | BARAMULLA | JAMMU AND KASHMIR | 193101 | ₹8.8 L | L1 | Admitted-Finance |
| 2 | L2₹9.0 LAdmitted-Finance | ₹9.0 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Failed to produce documents |
| Sl No | Description | Qty | Unit | HARMUKH INFRASTRUCTURE PRIVATE LIMITED L2 | ALIF INFRAPROJECTS PVT LTD L1 |
|---|---|---|---|---|---|
| 1.00 | Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11 KV Outgoing SCADA Compatible VCB Panel Board (12 kV, 1250A, 25 kA-3 Sec, Indoor) with Numerical O/C, E/F relays confirming to IEC61850, Master Trip Relay, Mimic Diagram, Digital Ammeter with ASS, PF Meter, Frequency Meter, Annunciation Windows with annunciation relays(6-Windows), 3-phase Tri-vector meter -5 Amps DLMS Compliant with RS-485 port ,Double Ratio; Two Core(0.5,5P10) Epoxy Casted CT with CTR :100-50/5-5A,TNC Switch, LR switch, Indication Lamps & other equipments as per approved Technical Specifications, of reputed make including Fixing of Earthing & Feeder Name Plate with Name of feeder written on it by using high intensity reflective Tape. (Reputed Make) | 1 | Job | 6,00,000 ₹6 L | 6,00,000 ₹6 L |
| 2.00 | Supply, Carriage upto site (including Loading/Unloading), Testing and Erection of Steel Tubular Pole, 9 Mtr. Long Pole(ST-410 SP33) with planting depth of 1/6 th of the height of the pole, (9 mtr. Long ) as per approved drawings/standards | 2 | No. | 22,000 ₹44,000 | 22,000 ₹44,000 |
| 3.00 | Supply, Carriage upto site (including Loading/Unloading),Testing,Fabrication & Fixing of GI Channel/Angle/Flat of sizes including clamps as per approved drawings/standards | 300 | Kg. | 140 ₹42,000 | 150 ₹45,000 |
| 4.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm as per approved drawings/standards | 3 | No. | 290 ₹870 | 300 ₹900 |
| 5.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting as per approved drawings/standards | 3 | No. | 499 ₹1,497 | 300 ₹900 |
| 6.00 | Supply, Carriage upto site (including Loading/Unloading),Installation,Testing & Commissioning of 11 kV Isolator, Double Break,3-pole, 630 Amp, Horizontal mounting Type, with Earth Switch (Reputed Make, Sample to be approved before installation) as per approved drawings/standards (1 Set- 3 Pieces) | 1 | Set | 42,000 ₹42,000 | 35,000 ₹35,000 |
| 7.00 | Supply, Carriage upto site (including Loading/Unloading),Installation,Testing & Commissioning of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type (Reputed Make) as per approved drawings/standards (1 Set-03 No.) | 1 | Set | 5,999 ₹5,999 | 2,000 ₹2,000 |
| 8.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI strip 25x3mm as per approved drawings/standards | 2 | No. | 499 ₹998 | 1,000 ₹2,000 |
| 9.00 | Providing & Painting of Poles with one coat of Red Oxide and two coats of aluminium paint and as per approved drawings/standards | 2 | No. | 499 ₹998 | 100 ₹200 |
| 10.00 | Supply,Carriage upto site (including Loading/Unloading), Laying & Testing of Cement bottoming for ST Poles 9 Mtr in the mixture of 1:2:4 0.48 cum/pole as per approved drawings/standards | 2 | Nos | 4,999 ₹9,998 | 3,000 ₹6,000 |
Tender Value
₹8.8 L
EMD Value
₹17,700
Closing Date
13 Jan 2026, 2:00 pmClosed
Executive Engineer STD Sopore
Executive Engineer STD Sopore
Augmentation/ Segregation of 11kV feeders to overcome LCP constraints (11kV Trikanjan feeder)
2025_PDD_296050_2
STDS/27 of 2025-26
Open Tender
Electrical and Maintenance Works
45 days
STD Sopore
Please refer Tender documents.
5 documents required · 5 mandatory
₹506
Yes
Executive Engineer STD Sopore
₹17,700
Yes
29 Jan 2026
2 Jan 2026
14 Jan 2026
2 Jan 2026
13 Jan 2026
3 Jan 2026
2 Jan 2026 - 3 Jan 2026
Supply, Carriage upto site (including Loading/Unloading),Installation, Testing & Commissioning of 11 KV Outgoing SCADA Compatible VCB Panel Board (12 kV, 1250A, 25 kA-3 Sec, Indoor) with Numerical O/C, E/F relays confirming to IEC61850, Master Trip Relay, Mimic Diagram, Digital Ammeter with ASS, PF Meter, Frequency Meter, Annunciation Windows with annunciation relays(6-Windows), 3-phase Tri-vector meter -5 Amps DLMS Compliant with RS-485 port ,Double Ratio; Two Core(0.5,5P10) Epoxy Casted CT with CTR :100-50/5-5A,TNC Switch, LR switch, Indication Lamps & other equipments as per approved Technical Specifications, of reputed make including Fixing of Earthing & Feeder Name Plate with Name of feeder written on it by using high intensity reflective Tape. (Reputed Make)
Supply, Carriage upto site (including Loading/Unloading), Testing and Erection of Steel Tubular Pole, 9 Mtr. Long Pole(ST-410 SP33) with planting depth of 1/6 th of the height of the pole, (9 mtr. Long ) as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing,Fabrication & Fixing of GI Channel/Angle/Flat of sizes including clamps as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Installation,Testing & Commissioning of 11 kV Isolator, Double Break,3-pole, 630 Amp, Horizontal mounting Type, with Earth Switch (Reputed Make, Sample to be approved before installation) as per approved drawings/standards (1 Set- 3 Pieces)
Supply, Carriage upto site (including Loading/Unloading),Installation,Testing & Commissioning of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type (Reputed Make) as per approved drawings/standards (1 Set-03 No.)
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI strip 25x3mm as per approved drawings/standards
Providing & Painting of Poles with one coat of Red Oxide and two coats of aluminium paint and as per approved drawings/standards
Supply,Carriage upto site (including Loading/Unloading), Laying & Testing of Cement bottoming for ST Poles 9 Mtr in the mixture of 1:2:4 0.48 cum/pole as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Installation,Testing & Commissioning of 11kV Three core 240 mm2 Aluminium wound wire Armoured XLPE FRLS Cable (KIE/Havells/Polycab or equivalent make)as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 11 kV Heat Shrinkable Outdoor Cable Termination Kit suitable for 240 mm² ( 3 Core) cable (3M/VIKCHEM/Denson or equivalent make) as per standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 11 kV Heat Shrinkable Indoor Cable Termination Kit suitable for 240 mm² ( 3 Core) cable (3M/VIKCHEM/Denson or equivalent make) as per standards
CONTENGENCIES /T&P/Spares
Supply, Carriage upto site (including Loading/Unloading),Testing of Complete Charging/ Gear Mechanism suitable for 11KV VCB
Supply, Carriage upto site (including Loading/Unloading),Testing of 20 A Auxiliary Switch forf 11 KV VCB Panel
Supply of A4 Papers 75 GSM of standard Quality
Supply of Printer Cartridge suitable for Canon laser Printer (071 A)( Canon OEM Make)
Supply, Carriage upto site (including Loading/Unloading),Testing of 30-36 VDC Tripping coils suitable for 11KV VCB
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
Tendernotice_2.pdf
PDF • 1.96 MB
SBD27.pdf
Tender Documents • 1.94 MB
BOQ_972287.xls
BOQ • 0.25 MB
Drawing-Panel1_merged.pdf
Tender Documents • 23.17 MB
Download all tender documents and submit your bid