Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹31.2 L+₹3.0 L (10.5%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹32.8 L+₹4.6 L (16.2%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹34.3 L+₹6.1 L (21.7%)Rejected-Finance 21 9TH MAIN 4TH CROSS GOWDAKEHOLA BAGALAKUNTE NAGASANDRA POST BANGALORE 560073 | BENGALURU URBAN | KARNATAKA | 560073 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹34.8 L+₹6.6 L (23.5%)Rejected-Finance D NO 29 2 43 SING HOTEL JUNCTION CMR ROAD VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | L5 | Rejected-Finance Being not L1 |
Tender Value
Refer Docs
EMD Value
₹95,980
Closing Date
6 Jul 2021, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR MAINT OF STREET LIGHTS HIGH MAST MID MAST LIGHTS PERIPHERY AND GATE LIGHTS AT INS CIRCARS INCS COMPLEX INS SATAVAHANA COMMAND STADIUM DOLPHIN FLEET GROUND INS VIRBAHU AND CERTAIN POCKETS OF NAVAL DOCKYARD AREA UNDER AGE EM NO I OF GE
2021_MES_451847_1
8326/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
D CLASS
10 documents required · 10 mandatory
₹500
Garrison Engineer Utility-I
₹95,980
Yes
1 Oct 2021
16 Jun 2021
8 Jul 2021
16 Jun 2021
6 Jul 2021
29 Jun 2021
Amount
M&L for preparation of old painted surface, cleaninig of oils, lubricants, grease etc complete of any type of 11.0 mtr long MS poles as per IS above PCC coping by applying one coat of aluminium paint including brackets, clamps including writing pole Nos as before all as directed.
M&L for preparation of old painted surface, cleaning of oils, lubricants, grease etc complete of any type of 9.0 mtr long poles as per IS above PCC coping with applying one coats of aluminium paint including brackets, clamps including writing pole Nos as before all as directed.
M & L for erection of vertically position steel tubular swaged poles complete with cast iron base plate,final taper plug,bolts,nuts & screws as specified type 410 SP-31 (9.0 meters long) and applying three coats of black bituminous paint throughout internally and two coats externally on the pole embedded in concrete and applying two coat of zinc chrome primer to the exposed surface including taking down existing old pole and all as directed.
Supply and fix hot press moulded junction boxes with hinged door, 4 P, 50 Amps rated connector and and neutral link mounted in the box,including necessary fixing arangement to the steel tubular pole/over walls including taking out old one complete all as specified and as directed. Make: Sintex /Hansel or equilvalent.
Supply and replacement of multi core PVC insulated stranded copper conductor of size 1.5 sqmm 3 core cable to be connected with street light fittings to loop-in and out boxes with its end point terminal connection complete all as specified and as directed. Make : Havells / Polycab / Finolex or equilvalent.
Supply and replacement of multi core PVC insulated stranded copper conductor of size 16 sqmm 4 core cable to be connected with street light fittings to high mast light panel and out boxes with its end point terminal connection complete all as specified and as directed. Make : Havells / Polycab / Finolex or equilvalent.
M&L for bracket for street light fitting made out of 50 mm bore pipe medium grade GI tube bent to shape required, fixed with and including MS flat iron clamps, bolts, nuts, washers duly painting the bracket with two coats of aluminium paint over a coat of zinc chrome primer complete including taking out old one. Make: Tata /Jindal or equilvalent.
Supplying, fixing and testing of Street lights LED type 90W pressure die cast aluminium housing high pwer LED as ligghing source and lens embedded PC cover having TOP openng separate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built in Surge Protection device. on 09 mtr poles Model no ENDURA PEARL PLUSSL90WLEDPASYTOPCASTHO of Havells or equivalent in Philips all as specified including taking out old one.
Supplying,fixing and testing of Street lights LED type 80 W pressure die cast aluminium housing luminaires complete (maintaining minmum system lumen-7000) on 9 mtr pole LED with IP protection 66 of Model no ENDURACITYLINERNEOMPSL80WLED757PASYBOTG or equivalent in Philips all as specified including taking out old one .
Supply & fixing high power LED Flood light fitting 100W complete ( mainting minmum system lumen-13700) on 11 mtr poles with IP protection 65 of Model No. JETAIRLISFLS100W757SYMLTG of Havells or equivalent in Philips inculding all fixing arrangement such as nuts&bolts,clamps and 50x50x5 mm and 60 cm long angle iron bracket dully two coat super enameled paint over one coat of red oxide etc. complete all as specified and directed by Engineer-in-Charge including taking out old one.
Supply & fixing high power LED Flood light fitting 200W complete 11 mtr poles with IP protection 66 of Model No. JETAVALOURFL200WLED 757MODNBLTGof Havells or equivalent in Philips inculding all fixing arrangement such as nuts&bolts,clamps and 50x50x5 mm and 60 cm long angle iron bracket dully two coat super enameled paint over one coat of red oxide etc. complete all as specified and directed by Engineer-in-Charge including taking out old one.
Supply & fixing high power LED Flood light fitting 100W complete 11 mtr poles with IP protection 65 of Model No. JETAIRISFLS100WLED 757SYMLTG of Havells or equivalent in Philips inculding all fixing arrangement such as nuts&bolts,clamps and 50 x 50 x 5 mm and 60 cm long angle iron bracket dully two coat super enameled paint over one coat of red oxide etc. complete all as specified and directed by Engineer-in-Charge including taking out old one.
Supply & fixing high power LED Flood light fitting 200W complete 11 mtr poles with IP protection 66 of Model No. JETA VALOURFL200WLED757PINBLTG of Havells or equivalent in Philips inculding all fixing arrangement such as nuts&bolts,clamps and 50x50x5 mm and 60 cm long angle iron bracket dully two coat super enameled paint over one coat of red oxide etc. complete all as specified and directed by Engineer-in-Charge including taking out old one.
Supply & fixing high power LED Flood light fitting 180W complete 11 mtr poles with IP protection 66 of Model No.JETA VALOURFL 180W LED 757PINtTNBLTG of Havells or equivalent in Philips inculding all fixing arrangement such as nuts&bolts,clamps and 50x50x5 mm and 60 cm long angle iron bracket dully two coat super enameled paint over one coat of red oxide etc. complete all as specified and directed by Engineer-in-Charge including taking out old one.
Supply & fixing high power LED Flood light fitting 50W complete 11 mtr poles with IP protection 66 of Model No. BJFL 50W LED I of BAJAJ or equivalent in HAVELLS inculding all fixing arrangement such as nuts&bolts,clamps and 50x50x5 mm and 60 cm long angle iron bracket dully two coat super enameled paint over one coat of red oxide etc. complete all as specified and directed by Engineer-in-Charge including taking out old one.
Supply & fixing high power LED Flood light fitting 100W complete 11 mtr poles with IP protection 66 of Model No. BJFL 100W LED I of BAJAJ or equivalent in HAVELLS inculding all fixing arrangement such as nuts&bolts,clamps and 50x50x5 mm and 60 cm long angle iron bracket dully two coat super enameled paint over one coat of red oxide etc. complete all as specified and directed by Engineer-in-Charge including taking out old one.
Taking down old unserviceable/ defective steel tubular Security street light fitting and Supply & fixing Solar smart intergreted Solar Street light with built in Mono Crystalline Panel, lithium ion battery (LiFePO4), MPPT charger controller, PIR sensor with colour temp 600-6500 K with 60 W cpacity LED light fittings with hybrid switch, Mono crystalline solar panel,42 Ah lithium ion battery fixed on 9.0 meter steel tubular pole complete with PCC foundation etc complete all as directed & specified. Make: M/s BAJAJ/Surya/CG/Philips/ Havells.
Taking down old unserviceable post top lantern fittings and Supply & fixing post top luminarie LED type of 45 W with IP 65 protection with die cast aluminium graphite grey powder coated finished body , polycarbonate opal diffuser, low power warm white (WW) LEDs with better heat dissipation, high efficient constant current electronic driver having operating voltage range from 140 to 280 Volt AC, provided with high voltage, open and short circuit protection, Voltage surge protection 10 KV etc complete suitable for 60 mm OD pipe entry including suitable size loop in loop out boxes & flexible 3 core 1.5 Sqmm copper connecting cable from loop in loop out box to fitting etc complete all as directed & specified. Make: M/s BAJAJ Model BGCP 45 W LED WW or equivalent in CG/Philips/ Havells. Note: The rate inclusive of GI pipe, PCC , cableloop in out box etc complete
Taking down old unserviceable post top lantern fittings and Supply & fixing post top luminarie LED type of 45 W with IP 65 protection with die cast aluminium graphite grey powder coated finished body , polycarbonate opal diffuser, low power warm white (WW) LEDs with better heat dissipation, high efficient constant current electronic driver having operating voltage range from 140 to 280 Volt AC, provided with high voltage, open and short circuit protection, Voltage surge protection 10 KV etc complete suitable for 60 mm OD pipe entry including suitable size loop in loop out boxes & flexible 3 core 1.5 Sqmm copper connecting cable from loop in loop out box to fitting etc complete all as directed & specified. Make: M/s BAJAJ Model BGCP 45 W LED WW or equivalent in CG/Philips/ Havells. Note: The rate inclusive of GI pipe, PCC , cableloop in out box etc complete
Taking down and Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 Volts grade 3.5 core XLPE (FRLS) , armoured, electric power cables (heavy duty) with aluminium conductor of the following size : Note: The rate quoted inclusive of termination at ends with suitable aluminium lugs whereever required. Make : Havells / Polycab / Finolex
50 sqmm 3.5 core
25 sqmm 4 core
16 sqmm 4 core
10 sqmm 2 core
Supplying, fixing and testing of timer switch 65A 3 pole / 230V analog time switch with connecting items fixing on pole / wall / panel all as directed. Make : Indoasian cat part no TL065ASO or equivalent in Havells/L&T/BCH including taking out old one .
S&F MCB TPN 63 amps 415 volts C curve complete all as specified and directed including taking out old one. Make : L&T /legrand/Schnieder
S&F MCB SPN 32 amps 230 volts C curve complete all as specified and directed including taking out old one. Make : L&T / Legrand / Schnieder
S&F MCB SPN 6 to 32 amps 230 volts C curve complete all as specified and directed including taking out old one. Make: L&T / legrand /Schnieder
Taking down defective street light fitting of any size /type/ capacity from height of pole/ walls/ height mast of any location exceeding 9 M height from ground level for reapir work and fixing back after repair work including checking, inspecting, testing and commissioning complete all as directed by Engr-in-Charge. Note : (a) Spares like ballast, lamp, starter, capacitor , igniter, holders, lamp holder, etc. shall be measured and paid separetely under relavant items of schedule'A' (b) Necessary tools like mobile ladder& other T&P required etc shall be arranged by the contractor (c) The rate quoted deemed to be inclusive for minor repair parts like nuts, bolts,cirle clips, clamps etc. if required at site.
Supply only the following spares for street light fittings (Make: Phillips/ Wipro/Havells)
LED driver 200w
LED driver 90W
LED driver 150 W
LED driver 45 W
LED driver 60/70W
LED driver 9 W
Excavating in trenches n. exc.1.5 m wide and n. exc.1.5 m in depth for foundation, trenches for laying cables / pipe line etc. and getting out in soft/loose soil complete all as specified and as directed.
Removing excavated materials to a distance n. exc. 50m and depositing where directed at a level n. exc 1.50m above the starting point complete all as specified and as directed.
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and as directed.
Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed. (Note: Punned thickness only shall be measured)
Supply and laying sub class 'B' bricks of old size (23x11x7cm) laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
M & L Plain cement concrete 1:4:8 type C2 (using 40 mm aggregrate) as in foundations filling mass concrete complete all as specified and as directed.
M &L for cement concrete PCC 1:2:4 type B1 (using 20 mm aggregrate) as coping of poles complete all as specified and as directed.
Supply and fix or laid in road crossing/ fixed to poles, GI Pipe of 50 mm size light grade for protection of cable complete all as specified and as directed.
Cutting trench through road/ wall to a width of 20cm and depth of 30cm for inserting GI protection pipe for drawing cable and filling back the trench with PCC 1:3:6 type C1 complete all as specified and as directed.
M&L for fixing in repair adhesive sticker radium type red coloured water resistant of approx 2 inches width around the circumference of pole at a approx height of two meters complete all as specified and as directed.
Repairs to High Mast/mid mast pole motor of Capacity 1.0 HP / 0.75 KW 415 Volts 50 Hz 3 Phase 930 RPM and necessary re-winding with super enamelled copper wire all as per existing and servicing/greasing of reduction gear box complete all as specified and as directed.
Repair/ Maint of the control panel of High mast / Mid mast and replacement of all unserviceable parts such as contactors / timers etc. complete including painting with a coat of synthetic enamel paint complete all as specified and as directed.
Repairs to High Mast/ mid mast of 12.5 mtr to 16 Mtr height lantern carriage / winch,checking for movement, inspecting the alignment, replacement of broken / defective SS wire roper of size 6 mm 7/19 construction complete, replacement of 5 core 2.5 Sqmm flexible copper conductor, ERP insulated PCP/PVC sheathed trailing cable complete, testing & commissioning all as specified and as directed.
SAI ENGINEERING WORKS
R AND A ASSOCIATES ENGINEERS CONTRACTORS
SRI MAHALAKSHMI CONSTRUCTIONS
KIRON ENGINEERING CORPORATION
DELTA CONSTRUCTIONS
RAJESH ENTERPRISES
SUPREET CONSTRUCTIONS
M/s SRINIVASA REDDY CONSTRUCTIONS
P VENKATA RAO
BHARGAVI ENGINEERING CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .