Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC | ₹17.3 L Quoted ₹18.0 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹20.6 L+₹2.6 L (14.4%)Rejected-Finance | ₹20.6 L+₹2.6 L (14.4%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹22.0 L+₹4.0 L (22.1%)Rejected-Finance 262 1 NEAR MANAV CHOWK NEW GRAIN MARKET AMBALA CITY HARYANA HARYANA 134003 | AMBALA | HARYANA | 134003 | ₹22.0 L+₹4.0 L (22.1%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹22.3 L+₹4.3 L (24.0%)Rejected-Finance SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | ₹22.3 L+₹4.3 L (24.0%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹22.5 L+₹4.5 L (25.1%)Rejected-Finance | ₹22.5 L+₹4.5 L (25.1%) | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
14 Jul 2021, 6:00 pmClosed
GE I R AND D Chandigarh
DIHAR Base Lab, Near 3 BRD (AF) Stn, Industrial Area Phase-II, Ramdarbar, Chandigarh
REPAIR/REPLACEMENT OF OLD UNSERVICEABLE SECURITY LIGHT/STREET LIGHT/ PERIMETER LIGHT FITTINGS, UG CABLE AND OTHER CONNECTED ITEM AT TBRL RANGE RAMGARH
2021_MES_443757_1
GE I R AND D/CHD-22/2021-22
Open Tender
Civil Works
Item Rate
180 days
Ramgarh
As tender documents
8 documents required · 8 mandatory
₹500
GE I R AND Chandigarh
₹50,000
Yes
27 Jul 2021
16 Jun 2021
16 Jul 2021
16 Jun 2021
14 Jul 2021
30 Jun 2021
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables, erection of poles,struts, stays etc and getting out all as specified and directed by Engr-In-Charge.
All as per serial item no 1.00 above but in PCC/floor/road all as specified and as directed by Engr-In-Charge.
All as per serial item no 1.00 above but depth exceeding 1.5 metre and not exceeding 3 metreall as specified and as directed by Engr-In-Charge.
Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested, poles,stays,struts hane been erected and tested complete all as specified.
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
Material and labour for clean dry sand laid in trenches/ducts for bedding and cushioning to cable, including spreading and levelling complete all as speccified.
Material and labour for laying in trenches burnt brick sub class 'B' for cable protection laid adjacent to each other length wise perpendicular to the central axis of cable complete all as specified.
Demolition of concrete (coping of PCC/GI pole/Road) of any description and in any position
Material and labour for PCC 1:3:6 type C2 using 40mm graded aggregate in coping of size (0.65x0.55x0.45) Mtr for PCC/RCC street light pole complete with 10mm thick cement plaster CM 1:4 on coping surface complete all as specified and directed.
Material and labour for PCC 1:3:6 type C2 using 40mm graded aggregate in coping of size (0.65x0.55x0.45) Mtr for steel tubular/GI street light pole complete with 10mm thick cement plaster CM 1:4 on coping surface complete all as specified and directed.
Supply & Erect in replacement of truly vertical position steel tubular swaged pole 09 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, including painting one under coat with anti corrosive primer and two coats of aluminium paint and in the botton above ground level alternative white & black strips of 30 cm width upto 1.5 mtr above ground level including taking down of old PCC poles complete all as required at site and directed by Engr-in-charge.
Supply and fixing for replacement of street light bracket arm fabricated out of 40 mm dia GI tubing light grade long bend to shape fixed to pole with 2 pair of suitable size clamps of fitted with suitable size nuts, bolts washers incl one coat of paint all as specified and directed
PCC 1:4:8 (nominal mix) type D-2 using 40mm graded crushed stone aggregates, as in foundation filling and mass concrete for poles and stay/installation paths complete all as specified and directed.
PCC 1:3:6 (nominal mix) type C-2 using 40mm graded crushed stone aggregates, as in foundation filling and mass concrete for poles and stay/installation paths complete all as specified and directed.
Material and labour for GI pipe of size 40mm bore, light grade for protection to cable from coping to loop-in-loop out Jn box fixed to street light pole including necessary fixing complete all as specified and directed.
Taking out from trenches/floors/road/wall/pipe/pole LT cable of any size/description and removing from site incl making good the disturbed surfaces to match with existing surface all as directed.
Supply and laying of UG cable XLPE insulated armoured heavy duty elect cable with stranded aluminium conductor 1100 volts grade cross section area 50 Sqmm 3.5 core laid in trenches/ fixing on panels/walls/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing complete all as specified and directed. (Note: (i) Cable joint shall be measured and paid separately.)
All as per serial item no. 15.00 above but of cross sectional area 25 Sqmm, 3.5 core.
All as per serial item no. 15.00 above but of cross sectional area 16 Sqmm, 4 core.
All as per serial item no. 15.00 above but of cross sectional area 10 Sqmm, 4 core.
All as per serial item no. 15.00 above but of cross sectional area 10 Sqmm, 4 core.
Supply and fixing for cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 16 to 50 sq mm complete all as specified and as directed.
Material and labour for cable joint termination junction box PVC body housing of size 200x160x98 mm suitable for housing and including 100 amps rated aluminium bus bar, 3 phase, 4 wire system mounted on PVC insulators for one incomming and two out going cable entry space mounted on street light PCC/ tubular pole with 25x3 mm FI clamps with nut, bolts and washers and including one 6 to 10 amps MCB, SP, 240 volt for street light supply complete all as as directed by Engr-in-charge. Make Sintex or equivalent.
Supply and fixing for repairs Driver for LED Light fitting 45 Watt all as specifed and directed by Engr in charge. Make:- ENDURA of Havells or equivalent Model of C&S , CG/Bajaj.
Supply and fixing for repairs LED Post top lantern of 1X40 Watt with die cast aluminium spigot and lid cover, high efficient LEDs and clear acrylic cover IP-65, complete all as specified and directed.
Supply and fixing for outdoor bollard light 8 watt LED 4000K Cone series acts as a imposing street furniture.The elegant yet minimalsitic design acts a silent observer and giving light, diffuser at the upper portion acts a beacon of path guidance in a landsacpe environment suitable for operation on 240V, 50Hz single phase including necessary PCC work, nut, bolts, washers etc and accessories required for mounting lights complete all as specified.
Dismantling and taking down carefully unserviceable street light fittings of any description from pole for replacing the new street light fittings as in its original position complete all as specified and directed (Note : New street light fitting will be measured and paid seperately)
Supply and install of 45W LED street light with pressure die cast aluminium housing, high power LED street light with heat resistant ,toughened glass with lense and driver to make it IP-66 degree of proction, Individual LED's must have lenses for better throw across & along the road, with system luminaire efficiency of greater than 80Lumen/Watt, Colour rendering (CRI) of ≥ 70 and co- related colour temperature (CCT) of 5700K (±500K) . The luminaire should have 5 KV surg protection, PF ≥ 0.9 and total harmonic distortion of THD ≤ 10%, voltage range of 140-280V should be provided. Over voltage proction should be there after 250 V +/- 10%. The manufactures logo must be embossed into the housing of the luminaire. Manufactures to provide LM80 report from source manufacturer and should have adequate testing facilities approved by NABL M79 and, including all connections complete all as specified.
Supply and fixing for new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 flood light luminaire 50 watt with high power LEDs as light source JETA NEO 50 and making necessary connections including taking down of old/UNSV street ight fiitngs complete all as specified and directed.
Supply and fixing for new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 flood light luminaire 100 watt with high power LEDs as light source JETA NEO 100 and making necessary connections including taking down of old/UNSV street ight fiitngs complete all as specified and directed.
Supply and fixing for energy saving & environmental friendly long life LED street light 70 watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection, impact resistance of IK07 & 10 KV external SPD and electronic driver of 70W LED 5700K complete all as specified and directed.
Supply and fixing for high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 of 20mm dia inclusive of all fitting accessories such as saddles, clamps etc for fixing on RCC/Steel tubular poles including dismantling existing unserviceable conduit pipe of any description complete all as specified and directed. Make : Gemini/Stiple.
Supply and fixing for repairs power contactor, type CN3 25F, four pole, 40Amp, 440 volt , all as specified and directed.
Supply and fixing for repairs power contactor, type CN5 40F, four pole, 60Amp, 440 volt , all as specified and directed.
Supply and fixing for repairs power contactor, type CN5 65F, four pole, 80Amp, 440 volt , Auxilary coil voltage 230 Volt, all as specified and directed.
Supply and fixing for repairs power contactor, type CN6 95F, four pole, 125Amp, 440 volt , Auxilary coil voltage 230 Volt, all as specified and directed.
Supply and fixing for repairs street light timer panel 3 phase 4 pole astronomical prewired with power contactor 32 Amps 3 pole, MCB 40 Amps TPN suitable for street light including all accesories all as specified and directed. Cat part No IHXTS0306A of Make : Havells or Equivalent of L&T/Legrand/Indoasian
Supply and fixing for PVC insulated and weather proof twin core copper multi stranded conductor cable 2.5 Sqmm size as required length for replacing unserviceable cable for street light where ever found unserviceable and required from over head conductor or junction box to street light connector of Street Light fittings all as specified & as directed by Engr-in-Charge.
Material and labour for removal green vegetation and dressing around the plinth/PCC hardstanding up to 1.5 mtr of sub stations and 2/4 pole structure etc including disposal of vegitation /material up to 50 mtr distance from the site and levelling/surfacing the ground all as specified and as directed by Engr-in-Charge.
Supply and fixing for MS clamps (duly painted with two coat of aluminium paint over a coat of red oxide primer) for fixing street light fittings/junction boxes/cable pipe on wall/floor /pole including MS nuts, bolts and washers etc as required as per site complete all as directed.
Supply and fixing for replacement of GI pipe of size 15mm bore, light grade for protection to cable from junction box to street light fixed to street light pole including taking down of old unsv PVC/HDPE pipe complete all as specified and directed. (Note : MS clamps, nuts, bolts and washers shall be measured and paid separately under respective itmes of Sch A)
Material and labour for service cable 6 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections/perimeter light supply as per site requirement, flat or circular all as required or directed.
Material and labour for service cable 10 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections/perimeter light supply as per site requirement, flat or circular all as required or directed.
Supply and fixing for bus bar chamber of suitable size with 4 strips 200 Amps bus bar aluminium along with MCCB of 100 Amp 4 pole adjustable type duly connected to aluminium strip at Incoming side with suiatble space for 2 incoming cables and outgoing of 2 cables .Bus bar fixed on insulators in zig-zag position, clearance in each strip and clearance at both side should not be less than 125mm with sufficient working space, height of bus bar chamber not less than 1 mtr, mounted MS angle 50x6mm, made of CRCA sheet 3 mm thick outdoor type, powder coated, both side opening, shutter in two halves, cable opening from bottom side with indicators R,Y,B, hinges through out the length of shutter with half turn locking arrangement, including grouting in PCC, all as directed by Engr-in-Charge. (Note : Size of Bus Bar chamber should not be Less than 1000 MM X 600 MM X 350 MM(LxBxD) all as specified and directed.)
Supply and fixing for replacement of LT line spacer made of High grade PVC suitable for LT OH conductor 4/5 ways all as specified and directed .
Material and labour for stay assembly complete with MS stay plate of size 300x300x6mm thick, stay rod 16mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR Part-I of 1991 or directed by Engr-in-charge ( Excavation, PCC, say wire and loop type insulators will be measured separately).
Material and labour for galvanized stay strand of size 7/2.24 mm including taking down old stay of any size and any description complete all as specified and directed by Engr in Charge.
Material and labour for loop type insulator large size with overall dimensions 90x140mm with clearance of hole 25.5 mm vitreous white brown or green complete all as specified and directed by Engr in Charge.
Dismantling ACSR or AAC conductor complete all as specified and directed.
Supply and fixing for aluminium conductor, steel reinforced (ACSR) of following sizes as in overhead conductor including fixing aluminium tapes for binding complete all as specified and directed: - (a) 6/1 x 3.0 - Ferret (b) 6/1 x 2.59 - Weasel (c) 6/1 x 2.11 - Squirrel Note: The weight of the conductor shall be determined as stipulated in Preamble (b) & (c) on Page 384 of SSR-2010 Part-II (Rates).
Cutting/trimming of tree branches under OH LT electric line including cleaning upto 3.00 mtr horizontal distance on both sides of OH electric line from ground level of the poles including removing all creepers smal bushes etc of under OH line upto 60 mitre each span complete all as specified and directed. (Note: Materials/T&P like Axies, Daw, rope and the like will be provided by the contractor without any extra cost to the Govt).
Complete removal of old paint from the steel tubular pole of 09 mtr height without removing accessories and preparation of surfaces for repainting the poles with and including two coats of synthetic enamal paint upto 1.50 mtr height having alternative white and black strips of 30 cm height each, including one coat of aluminium paint to the remaining part of pole (i.e above 1.50 mtr height) and its cross arms, bracing, support and all steel members complete all as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .