| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99.4 CrAccepted-AOC JAIPUR RAJASTHAN 302019 INDIA UDYAM RJ 17 0101683 | JAIPUR | RAJASTHAN | 302019 | ₹99.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹116.0 CrRejected-AOC | ₹116.0 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹118.0 CrRejected-AOC 10 HARDEEP ENCLAVE SIKANDRA AGRA U P 282007 | AGRA | UTTAR PRADESH | 282001 | ₹118.0 Cr | L3 | Rejected-AOC L3 |
Tender Value
₹77.1 Cr
EMD Value
₹1.5 Cr
Closing Date
19 Jan 2024, 5:00 pmClosed
SE, C and P, UPCL
C and P, Urja Bhawan, Kanwali Road,Dehradun
Loss Reduction Work under Revamped Distribution Sector Scheme EDC Srinagar Package-D
2023_UPCLC_65679_4
CCP-I/41/2023-2024
Open Tender
Electrical Works
730 days
As per tender conditions
As per tender conditions
6 documents required · 6 mandatory
₹29,500
Executive Engineer (HQ), UPCL
₹1.5 Cr
Urja Bhawan, Kanwali Road,Dehradun
8 Aug 2024
18 Nov 2023
20 Jan 2024
18 Nov 2023
19 Jan 2024
28 Dec 2023
5 Dec 2023
Amount
New 33 KV Underground Cable
33 KV UG XLPE 3x185 Sq mm Single Ckt.
SINGLE POLE STRUCTURE AS PER Annexure- B 7
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV top channel 125x65x6mm 1.8 mtr. Long with all fixing arrngement, PP, Clamp, bolts & nuts all galvanized
33 kV Polymeric Pin Insulator complete
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
DOUBLE POLE STRUCTURE AS PER Annexure- B 8
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
33 kV top channel 125x65x6mm 3.2 mtr. Long with all fixing arrngement, PP, Clamp, bolts & nuts all galvanized.
Base Channel (125X65X6) 3.050 mtr. Long with Clamps and fittings as per SBD specs all galvanized.
33 kV Polymeric Pin Insulator complete
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Supply of 3*185mm2 XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL)
Supply of HDPE Pipe PE 80/100 PN6 160 mm dia for HT cable (with colour coding of HDPE pipe as approved by UPCL in order to differentiate other voltage cables laid in other pipes) including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends
Supply of Half Cut 200mm Cement Hume Pipe/PCC Slab
CABLE LAYING : Laying of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using conventional excavation method and Laying the cable in Half Cut 200mm Cement Hume Pipe/PCC Slab at the depth of about 1.5 meter as per site requirement & Cable dia including using cable trench pullers (with Line tension Indicator) and provision of cable Labels ,Protectin Tape (Tape Tile) etc. complete in all respect in the form original before digging. (All the required material to be provided by contractor) (As per approved drawing of UPCL )
Laying and Pulling of 3*185mm2 XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) in half cut Hume Pipe/PCC slab.
Making of Trench using conventional excavation method
Laying of HT cable at the depth of about 1.5 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers (with Line tension Indicator) without open excavation in HDPE pipe:including provision of cable Labels
Laying and Pulling of 3*185mm2 XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) by Machine.
Laying of HDPE Pipe PE 80/100 PN6 160 mm dia for HT cable at the depth of about 1.5 meter (with colour coding of HDPE pipe as approved by UPCL in order to differentiate other voltage cables laid in other pipes) including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends
Laying of HT cable at the depth of about 1.5 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers (with Line tension Indicator) using conventional excavation method in HDPE pipe:including provision of cable Labels
Laying and Pulling of 33kV 3*185mm2 XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL)
Laying of High -Density Polythylene(HDPE) Pipe PE 80/100 PN6 160 mm Dia for XLPE Cable (colour of HDPE Pipe as per voltage level decided by UPCL) using conventional excavation method with making trench.
Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Underground Road crossing, Nala crossings etc complete in all respects including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends .GI Pipe 150 mm Dia
Laying and Pulling of 33kV 3*185mm2 XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL)
T-Connector for 33KV UG (As per Cable current Capacity )
Heat Shrinkable jointing kit for 3*185 Sq. mm. XLPE outdoor
Cable jointing kit straight through for 3*185 mm2. XLPE Cable
33KV 10 KA, outdoor type Lighting Arrester.
Supply and installation of Chemical earthing station as per IS 3043 complete with GI earthing electrode ,Bentonite, . Conductor upto test link, test link,earthing chamber, 450x450 mm C.I. Manhole chamber etc.
Supply and Fixing of Cable RCC Route Marker
New 33 KV Line with ACSR Conductor
33 KV New line with Rabbit conductor for Hills
SINGLE POLE STRUCTURE AS Per Annexure-C-20
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
DOUBLE POLE STRUCTURE AS PER Annexure-C-21
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV top channel 125x65x6mm 3.2 mtr. Long with all fixing arrngement, PP, Clamp, bolts & nuts all galvanized.
33 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
33 kV Polymeric Pin Insulator complete
GI Fish Plate 50x8mm for 33 kv DP.
33kV Disc fitting for Rabbit conductor 45 KN B&S type
33 kV Composite Polymer Disc Insulator B & S type
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
PG clamp/Wedge type for HTLS/Panther/Dog / Racoon conductor
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
FOUR POLE STRUCTURE AS PER Annexure-C-22
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV top channel 125x65x6mm 3.2 mtr. Long with all fixing arrngement, PP, Clamp, bolts & nuts all galvanized.
33 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
33 kV Polymeric Pin Insulator complete
33 kV E Clamp made of MS Channel (100X50X6)mm with Bolts & Nuts all galvanized.
33kV Disc fitting for Rabbit conductor 45 KN B&S type
33 kV Composite Polymer Disc Insulator B & S type
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
PG clamp/Wedge type for HTLS/Panther/Dog / Racoon conductor
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
ACSR RABBIT CONDUCTOR WITH 3% SAG AS PER Annexure-C-25
ACSR Rabbit Conductor with 3 % Sag
EARTH WIRE 7/16 SWG
Jointing Sleeve for Rabbit Conductor
GUARDING OF LINE AS PER Annexure -C-17
Guarding channel 100x50x6 mm,3750 mm long with holding clamp, packing piece, nut & bolts etc. all galvanized
GI Eye Bolt 16mm dia, 236mm long for guarding
8 SWG GI wire for guard wires and lacings
6 SWG GI wire for guard wires and lacings
G.I. Wire No. 16 SWG for binding
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
New 33 KV Bay With VCB's
33 KV Bay with SF-6 (SCADA Compatible)
Cost of Earthmat & Delta Earthing of Sub-station (M3)
M.S. Angle 65x65x6mm for cleat at cross joint all galvanized.
M.S Round 32mm dia, 6.21 Kg/mtr for earth mat, electodes for earth mat & delta earthing
Gravel pitching of size 1/2" to 3/4" (20x30x1)
G.I. Strip 65x6 mm.
G.I. Strip 40x6 mm.
Excavation of earth in mixed soil
Straightening and laying of Earth mat of 32 mm M S round 0.6 mtr deep in mixed soil according to drawing or as per UPCL direction or/and as per site requirement. Making T-joints, cross joint and Lap joints by welding of M S round bar together using cleats of MS Angles 65x65x6 mm, chipping the slag and painting of the joints with black bitumen paint (including supply of paint) to avoid rusting. Cutting & making electrode 2.5 mtr long with conical pointed bottom and driving of the electrode remains 450 mm below ground level. Backfilling of soil in trenches, ramming and leveling of trench properly after completion of eartmat and earthing work is complete. Making of Delta/Bridge earthing for structure/panels i.e. LA, 11 KV panels, ACDB, DCDB, Neutral of power & station transformer.
Earthing of structures using G.I. strips including strengthening, cutting, bending & welding with structure and equipments.
Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987
Earthfilling in yard
COST OF TERMINAL GANTRY WITH LA, Line Isolater,Bus Isolator, Post Insulator, CT, Busbar & connectors AT 33/11 KV SUB-STATION (M4)
COST OF TERMINAL GANTRY
M.S. Channel 125x65x65 mm all galvanized.
M.S. Angle 50x50x6mm all galvanized.
M.S. Channel 125x65x65 mm all galvanized.
33 kV Composite Polymer Disc Insulator B & S type
33kV Disc fitting for Panther conductor 90 KN B&S type
33KV 10 KA, outdoor type Lighting Arrester.
M.S. bolt & nut with washers all galvanized.
Stone pad 300x300x75 mm.
MS plate 225x225x8 mm thick all galvanized.
Fabrication charges of structure as per approved drawing
Excavation of earth in mixed soil
Grouting with Cement Concreating ratio with 1:3:6
Cement Plaster 1:4, on top & side walls
Erection of T.G. with LA
COST OF ONE SET OF LINE ISOLATOR
Line Isolator, 800A, 33KV
M.S. Channel 125x65x65 mm all galvanized.
M.S. Angle 75x75x8mm all galvanized.
M.S. Angle 50x50x6mm all galvanized.
M.S. flat 50x6 mm. all galvanized.
M.S. bolts & nut with washers all galvanized.
Fabrication charges of structure as per approved drawing
Excavation of earth in mixed soil
Grouting with Cement Concreating ratio with 1:3:6
Cement Plaster 1:4, on top & side walls
Erection charges of isolator structure
Erection charges of line isolator complete by assembeling, fixing of operating handle, pins etc for smooth operation of the isolator.
COST OF ONE SET OF BUS ISOLATOR
Bus Isolator, 800A, 33KV
M.S. Channel 125x65x65 mm all galvanized.
M.S. Angle 75x75x8mm all galvanized.
M.S. Angle 50x50x6mm all galvanized.
M.S. flat 50x6 mm. all galvanized.
M.S. bolts & nut with washers all galvanized.
Fabrication charges of structure as per approved drawing
Excavation of earth in mixed soil
Grouting with Cement Concreating ratio with 1:3:6
Cement Plaster 1:4, on top & side walls
Erection charges of isolator structure
Erection charges of Isolator complete by assembeling, fixing of operating handle, pins etc for smooth operation of the isolator.
COST OF ONE SET OF 33 KV P.I.
M.S. Channel 125x65x65 mm all galvanized.
M.S. Angle 75x75x8mm all galvanized.
33 KV Post Insulator
MS Plate 225x225x8 mm. all galvanized.
M.S. bolts & nut with washers all galvanized.
Fabrication charges of structure as per approved drawing
Excavation of earth in mixed soil
Grouting with Cement Concreating ratio with 1:3:6
Cement Plaster 1:4, on top & side walls
Erection charges of structure
Fixing and erection charges of Post Insulator
COST OF ONE SET OF CT
CT Out door, 33 KV CTR 200-100/1-1 A (SCADA Compatible)
M.S. Channel 125x65x65 mm all galvanized.
M.S. Angle 75x75x8mm all galvanized.
Junction box with 33 kv CT
MS Plate 400x400x8 mm all galvanized.
M.S. bolts & nut with washers all galvanized.
Fabrication charges of structure as per approved drawing
Excavation of earth in mixed soil
Grouting with Cement Concreating ratio with 1:3:6
Cement Plaster 1:4, on top & side walls
Erection charges of CT structure
Fixing and erection of CT
COST OF BUS BAR & CONNECTORS
ACSR PANTHER Conductor for Phase with 3% sag.
ACSR Weasel Conductor with 3 % Sag
33kV Disc fitting for Panther conductor 90 KN B&S type
33 kV Composite Polymer Disc Insulator B & S type
PG clamp/Wedge type for Panther to Panther
PG clamp/Wedge type for Panther to Dog
Connectors suitable for Panther
1. For LA suitable for panther
2. For LA suitable for dog/weasel
3. For Isolators suitable for panther
4. For Isolators suitable for dog/weasel
5. For CT/PT suitable for panther/dog
6. For PI suitable for panther
7. For , VCB suitable for panther
Labour charges for drawing bus-bar & making connection in each equipment, main & auxilary bus bar.
Cost of 33 KV SF6 -1250 AMP, Circuit Breaker & C&R Panels (M5)
33 KV SF6, 1250A, 24 V DC for I/c (SCADA Compatible)
Control Panel Inc 33 KV Single Ckt, 24 V DC (SCADA Compatible)
Control Panel Inc 33 KV Double Ckt, 24 V DC (SCADA Compatible)
Cost of 33 KV Cable Laying & Control Cable(M6)
Supply of 33kV (E) 3cx400mm2 XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL)
M.S CHANNEL 100X50MMX2.8 MTRX4X10 KG/MTR all galvanized.
Heat Shrinkable jointing kit for 33 kV 3cx400 Sq. mm. XLPE indoor/outdoor type
GI pipe 4" 3 mtr long
Laying of 33 kv/11 kv cable by excavation oc cable trench in mixed soil,filling of the sand upto height 250mm from bottom most level of the cable trench thereafter properly laing of the cable by placing brick on the both side of the cable then refilling of the sand from the top so as to cover the cable completely and then placing the bricks on the top of te covered cable, spreadinf of the cable warning tape and covering the tench completely with mixed soil including cost of sand bricks etc.
Filling of cable jointing kit 33 kv
Fabrication charges of structure as per approved drawing
COST OF LAYING LT CONTROL CABLES & CABLE TRENCH
M.S. Angle 50x50x6mm all galvanized.
LT Control Cable
iii) 10x2.5 Sq.mm
ii) 4x2.5 Sq.mm
i) 2x2.5 Sq.mm
MS Bar, 12mm
Perforated tray 400mm width for cable trench
Perforated tray 300 mm width for cable trench
Perforated tray 100 mm width for cable trench
Fabrication charges of structure as per approved drawing
Making cable trench.including fabrication, fixing of MS angle 50/40X6 mm size (excluding the cost of MS Angle/ MS bar) on side edge with all excavation, CC work, brick work, fixing of cable support angle one/two tier as required with stopper arrangement at 0.5 mtr gap throughout the length of the trench, making of cable trench covers with MS Bar welded mesh angle frame with lifting hooks, fixing of perforated tray complete as per drawing including cost of sand, cement, bricks, metal (gitti) etc.
Laying, spreading & jointing of LT control cable by using propers ties,lugs, connectors, cable glands in cable trench and equipments..
Cost of misc. items required for sub-station (M7)
24 V Battery charger with boost & trickle charge
24 V Battery set Maint. Free
DCDB 24 V
single line diagram board of size 2 1/2x 1 1/2 polyflex board with frame,duly painted & writing
Name plate of equipment TG, LI, BI, PI, BG, CT, PT, CB, LA etc. (Size 9"x5" with white base, red border & letter written in red color)
Sundries items Cable tie, Alu lug, Copper lug & HT, LT tape, pvc compound, ferrule, pvc flexible pipe, paint writing on panels, HT LT diff size cable gland.
COST OF FIRE PROTECTION
Rubber mat 1 mtr. wide x 2 mtr long and 12 mm thick to withstand 11 KV dielectric strength as per IS 5424-1969. Along the all equipments in Control Room.
Carbon dioxide (CO2) type fire extinguishers conforming to IS 2878 - 1976 and cylinders fully charged of 4.5 Kg capacity.
Foam type fire extinguishers, Portable type 5 lit capacity hanged on wall with bracket complete as required
Testing of S/s
Replacement of Old Aged VCBs
33KV Incomer (SCADA Compatible)
33 KV SF6, 1250A, 24 V DC for I/c (SCADA Compatible)
33kV Relay and Control Panel for Single Ckt.(SCADA Compatible)
33kV Relay and Control Panel for Single T/F.(SCADA Compatible)
33kV Relay and Control Panel for Double Ckt.(SCADA Compatible)
33kV Relay and Control Panel for Double T/F.(SCADA Compatible)
Dismantling of existing 33 KV CB & Control Panel.
33KV Outgoing (SCADA Compatible)
33 KV SF6, 1250A, 24 V DC for O/g (SCADA Compatible)
33kV Relay and Control Panel for Single Ckt.(SCADA Compatible)
33kV Relay and Control Panel for Single T/F.(SCADA Compatible)
33kV Relay and Control Panel for Double Ckt.(SCADA Compatible)
33kV Relay and Control Panel for Double T/F.(SCADA Compatible)
Dismantling of existing 33 KV CB & Control Panel.
Replacement of 33 KV Old /Frayed Conductor
Reconductoring of 33 KV line with Covered Dog Conductor
33 KV AL-59 ACS XLPE (160sq mm) Covered Conductor (SS4240813 & SS4240814) EN50397-1:2006 by Electron Beam radiation Process.Including Sag Percentage
33 kV Polymeric Pin Insulator complete
33KV Class Ball and Socket Polymeric tension insulator with Hardware with tracking IPC
IPC (160 sqmm MVCC to 160 sqmm MVCC)
IPC (Bare conductor to 160 sqmm MVCC) for 33 KV CC.
33 KV Insulated Cable Ties.
Supply IPC with Aluminium Bail for Earthing 3 No / Km(33 kv)
33 KV Mid span Jointing Kit Suitable for 240 Sqmm Covered Conductor.
Single pole SP 72 as per annexure -C-36
Steel Tubular Poles 13 m long (STP 13.0 M, 410 MPa , SP-72) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Single pole SP 55 as per annexure -J-21
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
33 KV Insulated Cable Ties.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Stay complete (As per annexure C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of 33 KV line with ACSR Panther Conductor
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
33 kV Polymeric Pin Insulator complete
Single pole SP 72 as per annexure -C-36
Steel Tubular Poles 13 m long (STP 13.0 M, 410 MPa , SP-72) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Additional Pole STP-55 for 33 KV line (As per annexure J-20)
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
33 kV Composite Polymer Disc Insulator B & S type
33kV Disc fitting for Panther conductor 90 KN B&S type
ACSR PANTHER Conductor for Phase with 3% sag.
Aluminum Binding wire & tape
Jointing Sleeve for PANTHER Conductor
PG clamp/Wedge type for Panther
Stay complete (As per annexure C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of 33 KV line with ACSR Raccoon to Dog Conductor
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
33 kV Polymeric Pin Insulator complete
Additional Pole STP-55 for 33 KV line (As per annexure J-20)
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
33kV Disc fitting for Dog conductor 90 KN B&S type
33 kV Composite Polymer Disc Insulator B & S type
ACSR Dog Conductor with 3 % Sag
Aluminum Binding wire & tape
Jointing Sleeves suitable for ACSR DOG conductor
PG clamp/Wedge type for DOG conductor
Stay complete (As per annexure C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
New 11 KV Line with ACSR Conductor
11 KV New line with Rabbit conductor for Hills SP-23&33
No. of Single pole as per annexure -F-33
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Aluminum paint (Double Coat)
Red Oxide paints
No. of Single pole as per annexure -F-19
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Aluminum paint (Double Coat)
Red Oxide paints
No. of Single Section pole as per annexure -F-20
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV MS channel 100x50x6mm 1.5 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc. Fittings B&S type 45 KN
PG clamp/Wedge type for ACSR Dog/Raccoon / Rabbit
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Aluminum paint (Double Coat)
Red Oxide paints
No. of Double Pole Structure as per annexure -F-35
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
11 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
11 kV Polymer Pin Insulator with Pin complete.
GI Fish Plate 50x8mm for 11 kv DP
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc Fittings B&S type 90/70 KN for ACSR Dog/Raccoon
11 kV Danger Board with GI clamp Bolts & Nuts
PG clamp/Wedge type for ACSR Dog/Raccoon / Rabbit
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
ACSR Rabbit Conductor for Phase with 3% sag.As per annexure-F-26
ACSR Rabbit Conductor with 3 % Sag
Jointing Sleeve for Rabbit Conductor
Guarding of 11 KV line. As per annexure- F-14 A
Guarding channel 100x50x6 mm,2210 mm long with holding clamp, packing piece, nut & bolts etc. all galvanized as per SBD
G.I. Wire No. 6 SWG along the span (For 1 Km. line)
G.I. Wire No. 8 SWG accross the span (For 1 Km. line)
GI Eye Bolt 16mm dia, 236mm long for guarding
G.I. Wire No. 16 SWG for binding
Stay complete (As per Annex F-15)
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
EARTH WIRE 7/16 SWG
11 kV Line : Reconductoring/Augmentation 11 KV line on Existing Pole
Reconductoring of 11 KV line with Covered Dog Conductor
11 KV AL-59 ACS XLPE (160sq mm) Dog Covered Conductor (SS4240813 & SS4240814) EN50397-1:2006 by Electron Beam radiation Process including Sag Percentage
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 KV Class Ball and Socket Polymeric tension insulator with Hardware with tracking IPC.
IPC (160sqmm MVCC to 160 sqmm MVCC) for 11 KV CC.
IPC (Bare Conductor to 160 sqmm MVCC) for 11 KV CC.
11 KV Insulated Cable Ties.
Supply IPC with Aluminium Bail for Earthing 3 No / Km(11KV)
11 KV Mid span Jointing Kit Suitable for 160 Sqmm Covered Conductor.
Single pole SP 55 as per annexure -J-21 A
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 KV Insulated Cable Ties.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Stay complete (As per annexure F-15)
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of 11 KV line with Covered Rabbit Conductor
11 KV AL-59 ACS XLPE (70sq mm)Rabbit Covered Conductor (SS4240813 & SS4240814) EN50397-1:2006 by Electron Beam radiation Process.Including Sag Percentage
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 KV Class Ball and Socket Polymeric tension insulator with Hardware with tracking IPC.
IPC (70 sqmm MVCC to 70 sqmm MVCC) for 11 KV CC.
IPC (Bare Conductor to 70 sqmm MVCC) for 11 KV CC.
11 KV Insulated Cable Ties.
Supply IPC with Aluminium Bail for Earthing 3 No / Km(11KV)
11 KV Mid span Jointing Kit Suitable for 70 Sqmm Covered Conductor.
Single pole SP 55 as per annexure -J-21 A
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 KV Insulated Cable Ties.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Stay complete (As per annexure F-15)
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of 11 KV line with ACSR Racoon Conductor
ACSR Raccoon Conductor with 3 % Sag
Additional Pole STP-33 for 11 KV line (As per Annex-J-10A)
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
11 kV Danger Board with clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Replacement of following damaged/wornout accessories
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc Fittings B&S type 70 KN for ACSR Raccoon
11 kV Polymer Pin Insulator with Pin complete.
P.G. clamps for Raccoon conductor
Aluminum Binding wire & tape
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of 11 KV line with ACSR Rabbit Conductor
ACSR Rabbit Conductor with 3 % Sag
Additional Pole STP-33 for 11 KV line (As per Annex-J-10A)
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
11 kV Danger Board with clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Replacement of following damaged/wornout accessories
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc. Fittings B&S type 45 KN
11 kV Polymer Pin Insulator with Pin complete.
P.G. clamps for Rabbit conductor
Aluminum Binding wire & tape
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of Old Aged VCBs/OCB
Replacement of 11KV Incomer complete with CTs of ratio 800/400/5A (SCADA Compatible)
11 kV VCB 500 MVA, 800/400/5A I/C (SCADA Compatible)
Dismantling of existing 11 KV VCB/OCB.
Replacement of 11KV Outgoing complete with CTs of ratio 400/200/5A (SCADA Compatible)
11 kV VCB FDR 500 MVA, 400/200/5A(Indoor Type) O/g (SCADA Compatible)
Dismantling of existing 11 KV VCB/OCB.
Replacement of 11KV Bus coupler with 11kV motorised Bus coupler (SCADA Compatible)
11 kV VCB FDR 500 MVA, Bus Coupler (SCADA Compatible)
Dismantling of existing 11 KV VCB/OCB.
Re-conductoring of bare LT line by LT ABC Replacement of LT Conductor with AB Cable in Theft Prone Areas
Reconductoring of LT AB Cable 3x95+1x70 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (95 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x95+1x70 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 70 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of LT AB Cable 3x50+1x35 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (50 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x50+1x35 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 35 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of LT AB Cable 3x25+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (25 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x25+25 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of LT AB Cable 3x16+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (16 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x16+1x25 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of Old /Frayed Conductor
Reconductroing of 2Ph 3w with ACSR Rabbit Conductor
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
LT Four Pin cross arm nut & Bolt all galvanized.
LT Shackle Insulator (90x75 mm)
Earth knob (Aluminium bobbin)
Shackle insulator GI clamp with accessories for 90x75 mm shackle insulator
ACSR conductor including 3% sag
ACSR Rabbit Conductor with 3 % Sag
ACSR Weasel Conductor with 3 % Sag
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Aluminum paint (Double Coat)
Red Oxide paints
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of 1Ph 2w with ACSR Rabbit Conductor
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
LT Four Pin cross arm nut & Bolt all galvanized.
LT Shackle Insulator (90x75 mm)
Earth knob (Aluminium bobbin)
Shackle insulator GI clamp with accessories for 90x75 mm shackle insulator
ACSR conductor including 3% sag
ACSR Rabbit Conductor with 3 % Sag
ACSR Weasel Conductor with 3 % Sag
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Aluminum paint (Double Coat)
Red Oxide paints
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of Aged DTR Structures
250 KVA To Above
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Plinth of T/F with RCC Top of size 2x4x1.6 Mtr. Incl. 2 nos. MS Channel All Galvanized as per SBD
Clamps for LT Take off with bolts and nuts all galvanized.
MS Channel 100x50x6mm, 2.800mtr. long (Top Channel) with all fixing arrangment PP, Clamps, Nuts & Bolts all galvanized as per SBD specs
MS Channel 100x50x6mm, 1.300 mtr. long (Tee off) with PP,clamp, Bolt and nuts all galvanized as per SBD specs
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc. Fittings B&S type 45 KN
11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch with 2 Nos. MS channel 100x50x6mm PP, clamps ,Bolt and nuts all galvanized as per SBD specs
11 kV Drop out fuse set for Transfoermer With MS Channel 100x50x6mm 1 no. 2.8 mtr. Long,PP , Clamp,Nuts&Bolts all galvanized
11 kV Polymer Pin Insulator with Pin complete.
ACSR Rabbit Conductor with 3 % Sag
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
11 kV Danger Board with GI clamp Bolts & Nuts
9KV, 5KA Outdoor type Lighting Arrester Polymer.
Chemical Earthing(with GI Strip 25x3mm for Neutral Earthing of Transformer
Chemical Earthing of Transformer Body(with GI strip 25x3mm),Other structure& Equipment( with GI Wire of 8 SWG)
Chemical Earthing of Lightning Arrestor with GI Strip 25x3mm
Aluminum lugs HT side
Aluminum crimping lugs LT side
1*240 Sq.mm.,single core `XLPE insulated un-armoured aluminium conductor cable
1*400 Sq.mm.,single core `XLPE insulated un-armoured aluminium conductor cable
fencing with gate as per specification and Turfing
Red Oxide paints
Aluminum paint (Double Coat)
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Stays Complete (As Per Annex. F-15 )
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of Aged DTR Structure with all worn out Accessories including Loading/Unloading Complete Work.
100 KVA & 160 KVA
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Clamps for LT Take off with bolts and nuts all galvanized.
MS Channel 100x50x6mm, 2.800mtr. long (Top Channel) with all fixing arrangment PP, Clamps, Nuts & Bolts all galvanized as per SBD specs
MS Channel 100x50x6mm, 1.300 mtr. long (Tee off) with PP,clamp, Bolt and nuts all galvanized as per SBD specs
MS Channel 100x50x6mm, 2.800 mtr. Long (for Transformer Base) with all fixing arrangment PP,Clamps,Nuts & Bolts all galvanized as per SBD specs
11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch with 2 Nos. MS channel 100x50x6mm PP, clamps ,Bolt and nuts all galvanized as per SBD specs
Transformer Belting Angle 50X50X6mm with all fixing arrangment PP,Clamps,Nuts & Bolts all galvanized.
11 kV Drop out fuse set for Transfoermer With MS Channel 100x50x6mm 1 no. 2.8 mtr. Long,PP , Clamp,Nuts&Bolts all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc. Fittings B&S type 45 KN
ACSR Rabbit Conductor with 3 % Sag
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
11 kV Danger Board with GI clamp Bolts & Nuts
9KV, 5KA Outdoor type Lighting Arrester Polymer.
Chemical Earthing(with GI Strip 25x3mm for Neutral Earthing of Transformer
Chemical Earthing of Transformer Body(with GI strip 25x3mm),Other structure& Equipment( with GI Wire of 8 SWG)
Chemical Earthing of Lightning Arrestor with GI Strip 25x3mm
Aluminum lugs HT side
Aluminum crimping lugs LT side
70 Sq.mm.,single core `XLPE insulated un-armoured aluminium conductor cable
120 Sq.mm.,single core `XLPE insulated un-armoured aluminium conductor cable
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Red Oxide paints
Aluminum paint (Double Coat)
Stays Complete (As Per Annex. F-15 )
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of Aged DTR Structure with all worn out Accessories including Loading/Unloading Complete Work.
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Clamps for LT Take off with bolts and nuts all galvanized.
MS Channel 100x50x6mm, 2.800mtr. long (Top Channel) with all fixing arrangment PP, Clamps, Nuts & Bolts all galvanized as per SBD specs
MS Channel 100x50x6mm, 1.300 mtr. long (Tee off) with PP,clamp, Bolt and nuts all galvanized as per SBD specs
MS Channel 100x50x6mm, 2.800 mtr. Long (for Transformer Base) with all fixing arrangment PP,Clamps,Nuts & Bolts all galvanized as per SBD specs
11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch with 2 Nos. MS channel 100x50x6mm PP, clamps ,Bolt and nuts all galvanized as per SBD specs
Transformer Belting Angle 50X50X6mm with all fixing arrangment PP,Clamps,Nuts & Bolts all galvanized.
11 kV Drop out fuse set for Transfoermer With MS Channel 100x50x6mm 1 no. 2.8 mtr. Long,PP , Clamp,Nuts&Bolts all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc. Fittings B&S type 45 KN
ACSR Rabbit Conductor with 3 % Sag
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
11 kV Danger Board with GI clamp Bolts & Nuts
9KV, 5KA Outdoor type Lighting Arrester Polymer.
Chemical Earthing(with GI Strip 25x3mm for Neutral Earthing of Transformer
Chemical Earthing of Transformer Body(with GI strip 25x3mm),Other structure& Equipment( with GI Wire of 8 SWG)
Chemical Earthing of Lightning Arrestor with GI Strip 25x3mm
Aluminum lugs HT side
Aluminum crimping lugs LT side
70 Sq.mm.,single core `XLPE insulated un-armoured aluminium conductor cable
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Red Oxide paints
Aluminum paint (Double Coat)
Stays Complete (As Per Annex. F-15 )
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of Aged DTR Structure with all worn out Accessories including Loading/Unloading Complete Work.
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Clamps for LT Take off with bolts and nuts all galvanized.
MS Channel 100x50x6mm, 2.800mtr. long (Top Channel) with all fixing arrangment PP, Clamps, Nuts & Bolts all galvanized as per SBD specs
MS Channel 100x50x6mm, 1.300 mtr. long (Tee off) with PP,clamp, Bolt and nuts all galvanized as per SBD specs
MS Channel 100x50x6mm, 2.800 mtr. Long (for Transformer Base) with all fixing arrangment PP,Clamps,Nuts & Bolts all galvanized as per SBD specs
11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch with 2 Nos. MS channel 100x50x6mm PP, clamps ,Bolt and nuts all galvanized as per SBD specs
Transformer Belting Angle 50X50X6mm with all fixing arrangment PP,Clamps,Nuts & Bolts all galvanized.
11 kV Drop out fuse set for Transfoermer With MS Channel 100x50x6mm 1 no. 2.8 mtr. Long,PP , Clamp,Nuts&Bolts all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc. Fittings B&S type 45 KN
ACSR Rabbit Conductor with 3 % Sag
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
11 kV Danger Board with GI clamp Bolts & Nuts
9KV, 5KA Outdoor type Lighting Arrester Polymer.
Chemical Earthing(with GI Strip 25x3mm for Neutral Earthing of Transformer
Chemical Earthing of Transformer Body(with GI strip 25x3mm),Other structure& Equipment( with GI Wire of 8 SWG)
Chemical Earthing of Lightning Arrestor with GI Strip 25x3mm
Aluminum lugs HT side
Aluminum crimping lugs LT side
35 Sq.mm.,single core `XLPE insulated un-armoured aluminium conductor cable
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Red Oxide paints
Aluminum paint (Double Coat)
Stays Complete (As Per Annex. F-15 )
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of Aged DTR Structure with all worn out Accessories including Loading/Unloading Complete Work.
Replacement of Damaged Pole's
33KV feeders
STP Pole SP-55
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
9.0 M PCC Poles
PCC Pole 9.0 Mtrs. Long
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
11KV feeders
ST POLE SP-33
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
9.0 M PCC Poles
PCC Pole 9.0 Mtrs. Long
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
LT Lines
STP Pole SP-21
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Aluminum paint (Double Coat)
Red Oxide paints
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
8.5 M PSCC poles
PCC Pole 8.5 Mtrs. Long
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
Damaged Double Poles structures
33 KV Line DPs
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV top channel 125x65x6mm 3.2 mtr. Long with all fixing arrngement, PP, Clamp, bolts & nuts all galvanized.
33 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
33 kV Polymeric Pin Insulator complete
GI Fish Plate 50x8mm for 33 kv DP.
33kV Disc fitting for Panther/Dog/Raccoon/Rabbit conductor 90/70/45 KN B&S type
33 kV Composite Polymer Disc Insulator B & S type
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
PG clamp/Wedge type for HTLS/Panther/Dog / Racoon conductor
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
11 KV Line DPs
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
11 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
11 kV Polymer Pin Insulator with Pin complete.
GI Fish Plate 50x8mm for 11 kv DP
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc Fittings B&S type 90/70 KN for ACSR Dog/Raccoon
11 kV Danger Board with GI clamp Bolts & Nuts
PG clamp/Wedge type for ACSR Dog/Raccoon / Rabbit
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Double Pole, Clamps, insulator Structure and accessories etc. including Loading/Unloading Complete Work.
Damaged Four Poles structures
33 KV 4 pole structure
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV top channel 125x65x6mm 3.2 mtr. Long with all fixing arrngement, PP, Clamp, bolts & nuts all galvanized.
33 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
33 kV Polymeric Pin Insulator complete
33 kV E Clamp made of MS Channel (100X50X6)mm with Bolts & Nuts all galvanized.
33kV Disc fitting for Panther/Dog/Raccoon/Rabbit conductor 90/70/45 KN B&S type
33 kV Composite Polymer Disc Insulator B & S type
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
PG clamp/Wedge type for HTLS/Panther/Dog / Racoon conductor
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Double Pole, Clamps, insulator Structure and accessories etc. including Loading/Unloading Complete Work.
11 KV 4 pole structure
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
11 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
11 kV Polymer Pin Insulator with Pin complete.
GI Fish Plate 50x8mm for 11 kv DP
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc Fittings B&S type 90/70 KN for ACSR Dog/Raccoon
11 kV Danger Board with GI clamp Bolts & Nuts
PG clamp/Wedge type for ACSR Dog/Raccoon / Rabbit
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Four Pole, Clamps, insulator Structure and accessories etc. including Loading/Unloading Complete Work.
Sign Board
Sign Board 1 No.in each town 6x4 feet (lengh x breadth) as per SBD.
Sign Board 1 No.in each town 6x4 feet (lengh x breadth) made of MS sheet 14 Gauge(1.6mm thickness) with angle suport of (3"x3",6mm) and height of board 6 feet fromm ground level to bottom of board and length of angle to be buried in the ground 1.50 feet with 1 feet hole pass inside,painting on board ( enamel paint with red oxide base coat)and printing on board (colour printing by Screen printing method)
Description of Work / Item(s)
Amount
New 33 KV Underground Cable
33 KV UG XLPE 3x185 Sq mm Single Ckt.
SINGLE POLE STRUCTURE AS PER Annexure- B 7
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV top channel 125x65x6mm 1.8 mtr. Long with all fixing arrngement, PP, Clamp, bolts & nuts all galvanized
33 kV Polymeric Pin Insulator complete
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
DOUBLE POLE STRUCTURE AS PER Annexure- B 8
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
33 kV top channel 125x65x6mm 3.2 mtr. Long with all fixing arrngement, PP, Clamp, bolts & nuts all galvanized.
Base Channel (125X65X6) 3.050 mtr. Long with Clamps and fittings as per SBD specs all galvanized.
33 kV Polymeric Pin Insulator complete
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Supply of 3*185mm2 XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL)
Supply of HDPE Pipe PE 80/100 PN6 160 mm dia for HT cable (with colour coding of HDPE pipe as approved by UPCL in order to differentiate other voltage cables laid in other pipes) including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends
Supply of Half Cut 200mm Cement Hume Pipe/PCC Slab
CABLE LAYING : Laying of HT cable as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using conventional excavation method and Laying the cable in Half Cut 200mm Cement Hume Pipe/PCC Slab at the depth of about 1.5 meter as per site requirement & Cable dia including using cable trench pullers (with Line tension Indicator) and provision of cable Labels ,Protectin Tape (Tape Tile) etc. complete in all respect in the form original before digging. (All the required material to be provided by contractor) (As per approved drawing of UPCL )
Laying and Pulling of 3*185mm2 XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) in half cut Hume Pipe/PCC slab.
Making of Trench using conventional excavation method
Laying of HT cable at the depth of about 1.5 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers (with Line tension Indicator) without open excavation in HDPE pipe:including provision of cable Labels
Laying and Pulling of 3*185mm2 XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL) by Machine.
Laying of HDPE Pipe PE 80/100 PN6 160 mm dia for HT cable at the depth of about 1.5 meter (with colour coding of HDPE pipe as approved by UPCL in order to differentiate other voltage cables laid in other pipes) including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends
Laying of HT cable at the depth of about 1.5 meter as per the code of practice for installation and maintenance of power cables as per IS 1255 :1983 or latest amendments using cable trench pullers (with Line tension Indicator) using conventional excavation method in HDPE pipe:including provision of cable Labels
Laying and Pulling of 33kV 3*185mm2 XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL)
Laying of High -Density Polythylene(HDPE) Pipe PE 80/100 PN6 160 mm Dia for XLPE Cable (colour of HDPE Pipe as per voltage level decided by UPCL) using conventional excavation method with making trench.
Supply and laying of B-Class Heavy duty GI pipe as IS 1239 at Underground Road crossing, Nala crossings etc complete in all respects including long bends,short bends, couplers etc to ensure proper safety of cables & to avoid damage at ends, bends .GI Pipe 150 mm Dia
Laying and Pulling of 33kV 3*185mm2 XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL)
T-Connector for 33KV UG (As per Cable current Capacity )
Heat Shrinkable jointing kit for 3*185 Sq. mm. XLPE outdoor
Cable jointing kit straight through for 3*185 mm2. XLPE Cable
33KV 10 KA, outdoor type Lighting Arrester.
Supply and installation of Chemical earthing station as per IS 3043 complete with GI earthing electrode ,Bentonite, . Conductor upto test link, test link,earthing chamber, 450x450 mm C.I. Manhole chamber etc.
Supply and Fixing of Cable RCC Route Marker
New 33 KV Line with ACSR Conductor
33 KV New line with Rabbit conductor for Hills
SINGLE POLE STRUCTURE AS Per Annexure-C-20
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
DOUBLE POLE STRUCTURE AS PER Annexure-C-21
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV top channel 125x65x6mm 3.2 mtr. Long with all fixing arrngement, PP, Clamp, bolts & nuts all galvanized.
33 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
33 kV Polymeric Pin Insulator complete
GI Fish Plate 50x8mm for 33 kv DP.
33kV Disc fitting for Rabbit conductor 45 KN B&S type
33 kV Composite Polymer Disc Insulator B & S type
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
PG clamp/Wedge type for HTLS/Panther/Dog / Racoon conductor
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
FOUR POLE STRUCTURE AS PER Annexure-C-22
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV top channel 125x65x6mm 3.2 mtr. Long with all fixing arrngement, PP, Clamp, bolts & nuts all galvanized.
33 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
33 kV Polymeric Pin Insulator complete
33 kV E Clamp made of MS Channel (100X50X6)mm with Bolts & Nuts all galvanized.
33kV Disc fitting for Rabbit conductor 45 KN B&S type
33 kV Composite Polymer Disc Insulator B & S type
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
PG clamp/Wedge type for HTLS/Panther/Dog / Racoon conductor
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
ACSR RABBIT CONDUCTOR WITH 3% SAG AS PER Annexure-C-25
ACSR Rabbit Conductor with 3 % Sag
EARTH WIRE 7/16 SWG
Jointing Sleeve for Rabbit Conductor
GUARDING OF LINE AS PER Annexure -C-17
Guarding channel 100x50x6 mm,3750 mm long with holding clamp, packing piece, nut & bolts etc. all galvanized
GI Eye Bolt 16mm dia, 236mm long for guarding
8 SWG GI wire for guard wires and lacings
6 SWG GI wire for guard wires and lacings
G.I. Wire No. 16 SWG for binding
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
New 33 KV Bay With VCB's
33 KV Bay with SF-6 (SCADA Compatible)
Cost of Earthmat & Delta Earthing of Sub-station (M3)
M.S. Angle 65x65x6mm for cleat at cross joint all galvanized.
M.S Round 32mm dia, 6.21 Kg/mtr for earth mat, electodes for earth mat & delta earthing
Gravel pitching of size 1/2" to 3/4" (20x30x1)
G.I. Strip 65x6 mm.
G.I. Strip 40x6 mm.
Excavation of earth in mixed soil
Straightening and laying of Earth mat of 32 mm M S round 0.6 mtr deep in mixed soil according to drawing or as per UPCL direction or/and as per site requirement. Making T-joints, cross joint and Lap joints by welding of M S round bar together using cleats of MS Angles 65x65x6 mm, chipping the slag and painting of the joints with black bitumen paint (including supply of paint) to avoid rusting. Cutting & making electrode 2.5 mtr long with conical pointed bottom and driving of the electrode remains 450 mm below ground level. Backfilling of soil in trenches, ramming and leveling of trench properly after completion of eartmat and earthing work is complete. Making of Delta/Bridge earthing for structure/panels i.e. LA, 11 KV panels, ACDB, DCDB, Neutral of power & station transformer.
Earthing of structures using G.I. strips including strengthening, cutting, bending & welding with structure and equipments.
Special earthing by treatment of soil with highly conducted material like combination of bentonite, conductive cement, coke dust, sodium carbonate, MgSo4, NaCl & CaCl2 as per ISS 3043-1987
Earthfilling in yard
COST OF TERMINAL GANTRY WITH LA, Line Isolater,Bus Isolator, Post Insulator, CT, Busbar & connectors AT 33/11 KV SUB-STATION (M4)
COST OF TERMINAL GANTRY
M.S. Channel 125x65x65 mm all galvanized.
M.S. Angle 50x50x6mm all galvanized.
M.S. Channel 125x65x65 mm all galvanized.
33 kV Composite Polymer Disc Insulator B & S type
33kV Disc fitting for Panther conductor 90 KN B&S type
33KV 10 KA, outdoor type Lighting Arrester.
M.S. bolt & nut with washers all galvanized.
Stone pad 300x300x75 mm.
MS plate 225x225x8 mm thick all galvanized.
Fabrication charges of structure as per approved drawing
Excavation of earth in mixed soil
Grouting with Cement Concreating ratio with 1:3:6
Cement Plaster 1:4, on top & side walls
Erection of T.G. with LA
COST OF ONE SET OF LINE ISOLATOR
Line Isolator, 800A, 33KV
M.S. Channel 125x65x65 mm all galvanized.
M.S. Angle 75x75x8mm all galvanized.
M.S. Angle 50x50x6mm all galvanized.
M.S. flat 50x6 mm. all galvanized.
M.S. bolts & nut with washers all galvanized.
Fabrication charges of structure as per approved drawing
Excavation of earth in mixed soil
Grouting with Cement Concreating ratio with 1:3:6
Cement Plaster 1:4, on top & side walls
Erection charges of isolator structure
Erection charges of line isolator complete by assembeling, fixing of operating handle, pins etc for smooth operation of the isolator.
COST OF ONE SET OF BUS ISOLATOR
Bus Isolator, 800A, 33KV
M.S. Channel 125x65x65 mm all galvanized.
M.S. Angle 75x75x8mm all galvanized.
M.S. Angle 50x50x6mm all galvanized.
M.S. flat 50x6 mm. all galvanized.
M.S. bolts & nut with washers all galvanized.
Fabrication charges of structure as per approved drawing
Excavation of earth in mixed soil
Grouting with Cement Concreating ratio with 1:3:6
Cement Plaster 1:4, on top & side walls
Erection charges of isolator structure
Erection charges of Isolator complete by assembeling, fixing of operating handle, pins etc for smooth operation of the isolator.
COST OF ONE SET OF 33 KV P.I.
M.S. Channel 125x65x65 mm all galvanized.
M.S. Angle 75x75x8mm all galvanized.
33 KV Post Insulator
MS Plate 225x225x8 mm. all galvanized.
M.S. bolts & nut with washers all galvanized.
Fabrication charges of structure as per approved drawing
Excavation of earth in mixed soil
Grouting with Cement Concreating ratio with 1:3:6
Cement Plaster 1:4, on top & side walls
Erection charges of structure
Fixing and erection charges of Post Insulator
COST OF ONE SET OF CT
CT Out door, 33 KV CTR 200-100/1-1 A (SCADA Compatible)
M.S. Channel 125x65x65 mm all galvanized.
M.S. Angle 75x75x8mm all galvanized.
Junction box with 33 kv CT
MS Plate 400x400x8 mm all galvanized.
M.S. bolts & nut with washers all galvanized.
Fabrication charges of structure as per approved drawing
Excavation of earth in mixed soil
Grouting with Cement Concreating ratio with 1:3:6
Cement Plaster 1:4, on top & side walls
Erection charges of CT structure
Fixing and erection of CT
COST OF BUS BAR & CONNECTORS
ACSR PANTHER Conductor for Phase with 3% sag.
ACSR Weasel Conductor with 3 % Sag
33kV Disc fitting for Panther conductor 90 KN B&S type
33 kV Composite Polymer Disc Insulator B & S type
PG clamp/Wedge type for Panther to Panther
PG clamp/Wedge type for Panther to Dog
Connectors suitable for Panther
1. For LA suitable for panther
2. For LA suitable for dog/weasel
3. For Isolators suitable for panther
4. For Isolators suitable for dog/weasel
5. For CT/PT suitable for panther/dog
6. For PI suitable for panther
7. For , VCB suitable for panther
Labour charges for drawing bus-bar & making connection in each equipment, main & auxilary bus bar.
Cost of 33 KV SF6 -1250 AMP, Circuit Breaker & C&R Panels (M5)
33 KV SF6, 1250A, 24 V DC for I/c (SCADA Compatible)
Control Panel Inc 33 KV Single Ckt, 24 V DC (SCADA Compatible)
Control Panel Inc 33 KV Double Ckt, 24 V DC (SCADA Compatible)
Cost of 33 KV Cable Laying & Control Cable(M6)
Supply of 33kV (E) 3cx400mm2 XLPE Underground cable (Cable outer sheet colour as per voltage level decided by UPCL)
M.S CHANNEL 100X50MMX2.8 MTRX4X10 KG/MTR all galvanized.
Heat Shrinkable jointing kit for 33 kV 3cx400 Sq. mm. XLPE indoor/outdoor type
GI pipe 4" 3 mtr long
Laying of 33 kv/11 kv cable by excavation oc cable trench in mixed soil,filling of the sand upto height 250mm from bottom most level of the cable trench thereafter properly laing of the cable by placing brick on the both side of the cable then refilling of the sand from the top so as to cover the cable completely and then placing the bricks on the top of te covered cable, spreadinf of the cable warning tape and covering the tench completely with mixed soil including cost of sand bricks etc.
Filling of cable jointing kit 33 kv
Fabrication charges of structure as per approved drawing
COST OF LAYING LT CONTROL CABLES & CABLE TRENCH
M.S. Angle 50x50x6mm all galvanized.
LT Control Cable
iii) 10x2.5 Sq.mm
ii) 4x2.5 Sq.mm
i) 2x2.5 Sq.mm
MS Bar, 12mm
Perforated tray 400mm width for cable trench
Perforated tray 300 mm width for cable trench
Perforated tray 100 mm width for cable trench
Fabrication charges of structure as per approved drawing
Making cable trench.including fabrication, fixing of MS angle 50/40X6 mm size (excluding the cost of MS Angle/ MS bar) on side edge with all excavation, CC work, brick work, fixing of cable support angle one/two tier as required with stopper arrangement at 0.5 mtr gap throughout the length of the trench, making of cable trench covers with MS Bar welded mesh angle frame with lifting hooks, fixing of perforated tray complete as per drawing including cost of sand, cement, bricks, metal (gitti) etc.
Laying, spreading & jointing of LT control cable by using propers ties,lugs, connectors, cable glands in cable trench and equipments..
Cost of misc. items required for sub-station (M7)
24 V Battery charger with boost & trickle charge
24 V Battery set Maint. Free
DCDB 24 V
single line diagram board of size 2 1/2x 1 1/2 polyflex board with frame,duly painted & writing
Name plate of equipment TG, LI, BI, PI, BG, CT, PT, CB, LA etc. (Size 9"x5" with white base, red border & letter written in red color)
Sundries items Cable tie, Alu lug, Copper lug & HT, LT tape, pvc compound, ferrule, pvc flexible pipe, paint writing on panels, HT LT diff size cable gland.
COST OF FIRE PROTECTION
Rubber mat 1 mtr. wide x 2 mtr long and 12 mm thick to withstand 11 KV dielectric strength as per IS 5424-1969. Along the all equipments in Control Room.
Carbon dioxide (CO2) type fire extinguishers conforming to IS 2878 - 1976 and cylinders fully charged of 4.5 Kg capacity.
Foam type fire extinguishers, Portable type 5 lit capacity hanged on wall with bracket complete as required
Testing of S/s
Replacement of Old Aged VCBs
33KV Incomer (SCADA Compatible)
33 KV SF6, 1250A, 24 V DC for I/c (SCADA Compatible)
33kV Relay and Control Panel for Single Ckt.(SCADA Compatible)
33kV Relay and Control Panel for Single T/F.(SCADA Compatible)
33kV Relay and Control Panel for Double Ckt.(SCADA Compatible)
33kV Relay and Control Panel for Double T/F.(SCADA Compatible)
Dismantling of existing 33 KV CB & Control Panel.
33KV Outgoing (SCADA Compatible)
33 KV SF6, 1250A, 24 V DC for O/g (SCADA Compatible)
33kV Relay and Control Panel for Single Ckt.(SCADA Compatible)
33kV Relay and Control Panel for Single T/F.(SCADA Compatible)
33kV Relay and Control Panel for Double Ckt.(SCADA Compatible)
33kV Relay and Control Panel for Double T/F.(SCADA Compatible)
Dismantling of existing 33 KV CB & Control Panel.
Replacement of 33 KV Old /Frayed Conductor
Reconductoring of 33 KV line with Covered Dog Conductor
33 KV AL-59 ACS XLPE (160sq mm) Covered Conductor (SS4240813 & SS4240814) EN50397-1:2006 by Electron Beam radiation Process.Including Sag Percentage
33 kV Polymeric Pin Insulator complete
33KV Class Ball and Socket Polymeric tension insulator with Hardware with tracking IPC
IPC (160 sqmm MVCC to 160 sqmm MVCC)
IPC (Bare conductor to 160 sqmm MVCC) for 33 KV CC.
33 KV Insulated Cable Ties.
Supply IPC with Aluminium Bail for Earthing 3 No / Km(33 kv)
33 KV Mid span Jointing Kit Suitable for 240 Sqmm Covered Conductor.
Single pole SP 72 as per annexure -C-36
Steel Tubular Poles 13 m long (STP 13.0 M, 410 MPa , SP-72) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Single pole SP 55 as per annexure -J-21
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
33 KV Insulated Cable Ties.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Stay complete (As per annexure C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of 33 KV line with ACSR Panther Conductor
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
33 kV Polymeric Pin Insulator complete
Single pole SP 72 as per annexure -C-36
Steel Tubular Poles 13 m long (STP 13.0 M, 410 MPa , SP-72) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Additional Pole STP-55 for 33 KV line (As per annexure J-20)
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
33 kV Composite Polymer Disc Insulator B & S type
33kV Disc fitting for Panther conductor 90 KN B&S type
ACSR PANTHER Conductor for Phase with 3% sag.
Aluminum Binding wire & tape
Jointing Sleeve for PANTHER Conductor
PG clamp/Wedge type for Panther
Stay complete (As per annexure C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of 33 KV line with ACSR Raccoon to Dog Conductor
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
33 kV Polymeric Pin Insulator complete
Additional Pole STP-55 for 33 KV line (As per annexure J-20)
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
33kV Disc fitting for Dog conductor 90 KN B&S type
33 kV Composite Polymer Disc Insulator B & S type
ACSR Dog Conductor with 3 % Sag
Aluminum Binding wire & tape
Jointing Sleeves suitable for ACSR DOG conductor
PG clamp/Wedge type for DOG conductor
Stay complete (As per annexure C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
New 11 KV Line with ACSR Conductor
11 KV New line with Rabbit conductor for Hills SP-23&33
No. of Single pole as per annexure -F-33
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Aluminum paint (Double Coat)
Red Oxide paints
No. of Single pole as per annexure -F-19
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Aluminum paint (Double Coat)
Red Oxide paints
No. of Single Section pole as per annexure -F-20
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV MS channel 100x50x6mm 1.5 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc. Fittings B&S type 45 KN
PG clamp/Wedge type for ACSR Dog/Raccoon / Rabbit
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Aluminum paint (Double Coat)
Red Oxide paints
No. of Double Pole Structure as per annexure -F-35
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-23) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
11 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
11 kV Polymer Pin Insulator with Pin complete.
GI Fish Plate 50x8mm for 11 kv DP
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc Fittings B&S type 90/70 KN for ACSR Dog/Raccoon
11 kV Danger Board with GI clamp Bolts & Nuts
PG clamp/Wedge type for ACSR Dog/Raccoon / Rabbit
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
ACSR Rabbit Conductor for Phase with 3% sag.As per annexure-F-26
ACSR Rabbit Conductor with 3 % Sag
Jointing Sleeve for Rabbit Conductor
Guarding of 11 KV line. As per annexure- F-14 A
Guarding channel 100x50x6 mm,2210 mm long with holding clamp, packing piece, nut & bolts etc. all galvanized as per SBD
G.I. Wire No. 6 SWG along the span (For 1 Km. line)
G.I. Wire No. 8 SWG accross the span (For 1 Km. line)
GI Eye Bolt 16mm dia, 236mm long for guarding
G.I. Wire No. 16 SWG for binding
Stay complete (As per Annex F-15)
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
EARTH WIRE 7/16 SWG
11 kV Line : Reconductoring/Augmentation 11 KV line on Existing Pole
Reconductoring of 11 KV line with Covered Dog Conductor
11 KV AL-59 ACS XLPE (160sq mm) Dog Covered Conductor (SS4240813 & SS4240814) EN50397-1:2006 by Electron Beam radiation Process including Sag Percentage
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 KV Class Ball and Socket Polymeric tension insulator with Hardware with tracking IPC.
IPC (160sqmm MVCC to 160 sqmm MVCC) for 11 KV CC.
IPC (Bare Conductor to 160 sqmm MVCC) for 11 KV CC.
11 KV Insulated Cable Ties.
Supply IPC with Aluminium Bail for Earthing 3 No / Km(11KV)
11 KV Mid span Jointing Kit Suitable for 160 Sqmm Covered Conductor.
Single pole SP 55 as per annexure -J-21 A
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 KV Insulated Cable Ties.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Stay complete (As per annexure F-15)
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of 11 KV line with Covered Rabbit Conductor
11 KV AL-59 ACS XLPE (70sq mm)Rabbit Covered Conductor (SS4240813 & SS4240814) EN50397-1:2006 by Electron Beam radiation Process.Including Sag Percentage
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 KV Class Ball and Socket Polymeric tension insulator with Hardware with tracking IPC.
IPC (70 sqmm MVCC to 70 sqmm MVCC) for 11 KV CC.
IPC (Bare Conductor to 70 sqmm MVCC) for 11 KV CC.
11 KV Insulated Cable Ties.
Supply IPC with Aluminium Bail for Earthing 3 No / Km(11KV)
11 KV Mid span Jointing Kit Suitable for 70 Sqmm Covered Conductor.
Single pole SP 55 as per annexure -J-21 A
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 KV Insulated Cable Ties.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Stay complete (As per annexure F-15)
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of 11 KV line with ACSR Racoon Conductor
ACSR Raccoon Conductor with 3 % Sag
Additional Pole STP-33 for 11 KV line (As per Annex-J-10A)
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
11 kV Danger Board with clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Replacement of following damaged/wornout accessories
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc Fittings B&S type 70 KN for ACSR Raccoon
11 kV Polymer Pin Insulator with Pin complete.
P.G. clamps for Raccoon conductor
Aluminum Binding wire & tape
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of 11 KV line with ACSR Rabbit Conductor
ACSR Rabbit Conductor with 3 % Sag
Additional Pole STP-33 for 11 KV line (As per Annex-J-10A)
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
11 kV Danger Board with clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Replacement of following damaged/wornout accessories
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc. Fittings B&S type 45 KN
11 kV Polymer Pin Insulator with Pin complete.
P.G. clamps for Rabbit conductor
Aluminum Binding wire & tape
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of Old Aged VCBs/OCB
Replacement of 11KV Incomer complete with CTs of ratio 800/400/5A (SCADA Compatible)
11 kV VCB 500 MVA, 800/400/5A I/C (SCADA Compatible)
Dismantling of existing 11 KV VCB/OCB.
Replacement of 11KV Outgoing complete with CTs of ratio 400/200/5A (SCADA Compatible)
11 kV VCB FDR 500 MVA, 400/200/5A(Indoor Type) O/g (SCADA Compatible)
Dismantling of existing 11 KV VCB/OCB.
Replacement of 11KV Bus coupler with 11kV motorised Bus coupler (SCADA Compatible)
11 kV VCB FDR 500 MVA, Bus Coupler (SCADA Compatible)
Dismantling of existing 11 KV VCB/OCB.
Re-conductoring of bare LT line by LT ABC Replacement of LT Conductor with AB Cable in Theft Prone Areas
Reconductoring of LT AB Cable 3x95+1x70 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (95 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x95+1x70 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 70 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of LT AB Cable 3x50+1x35 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (50 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x50+1x35 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 35 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of LT AB Cable 3x25+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (25 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x25+25 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of LT AB Cable 3x16+1x25 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (16 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x16+1x25 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type 25 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of Old /Frayed Conductor
Reconductroing of 2Ph 3w with ACSR Rabbit Conductor
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
LT Four Pin cross arm nut & Bolt all galvanized.
LT Shackle Insulator (90x75 mm)
Earth knob (Aluminium bobbin)
Shackle insulator GI clamp with accessories for 90x75 mm shackle insulator
ACSR conductor including 3% sag
ACSR Rabbit Conductor with 3 % Sag
ACSR Weasel Conductor with 3 % Sag
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Aluminum paint (Double Coat)
Red Oxide paints
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Reconductoring of 1Ph 2w with ACSR Rabbit Conductor
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
LT Four Pin cross arm nut & Bolt all galvanized.
LT Shackle Insulator (90x75 mm)
Earth knob (Aluminium bobbin)
Shackle insulator GI clamp with accessories for 90x75 mm shackle insulator
ACSR conductor including 3% sag
ACSR Rabbit Conductor with 3 % Sag
ACSR Weasel Conductor with 3 % Sag
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Aluminum paint (Double Coat)
Red Oxide paints
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of Aged DTR Structures
250 KVA To Above
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Plinth of T/F with RCC Top of size 2x4x1.6 Mtr. Incl. 2 nos. MS Channel All Galvanized as per SBD
Clamps for LT Take off with bolts and nuts all galvanized.
MS Channel 100x50x6mm, 2.800mtr. long (Top Channel) with all fixing arrangment PP, Clamps, Nuts & Bolts all galvanized as per SBD specs
MS Channel 100x50x6mm, 1.300 mtr. long (Tee off) with PP,clamp, Bolt and nuts all galvanized as per SBD specs
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc. Fittings B&S type 45 KN
11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch with 2 Nos. MS channel 100x50x6mm PP, clamps ,Bolt and nuts all galvanized as per SBD specs
11 kV Drop out fuse set for Transfoermer With MS Channel 100x50x6mm 1 no. 2.8 mtr. Long,PP , Clamp,Nuts&Bolts all galvanized
11 kV Polymer Pin Insulator with Pin complete.
ACSR Rabbit Conductor with 3 % Sag
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
11 kV Danger Board with GI clamp Bolts & Nuts
9KV, 5KA Outdoor type Lighting Arrester Polymer.
Chemical Earthing(with GI Strip 25x3mm for Neutral Earthing of Transformer
Chemical Earthing of Transformer Body(with GI strip 25x3mm),Other structure& Equipment( with GI Wire of 8 SWG)
Chemical Earthing of Lightning Arrestor with GI Strip 25x3mm
Aluminum lugs HT side
Aluminum crimping lugs LT side
1*240 Sq.mm.,single core `XLPE insulated un-armoured aluminium conductor cable
1*400 Sq.mm.,single core `XLPE insulated un-armoured aluminium conductor cable
fencing with gate as per specification and Turfing
Red Oxide paints
Aluminum paint (Double Coat)
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Stays Complete (As Per Annex. F-15 )
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of Aged DTR Structure with all worn out Accessories including Loading/Unloading Complete Work.
100 KVA & 160 KVA
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Clamps for LT Take off with bolts and nuts all galvanized.
MS Channel 100x50x6mm, 2.800mtr. long (Top Channel) with all fixing arrangment PP, Clamps, Nuts & Bolts all galvanized as per SBD specs
MS Channel 100x50x6mm, 1.300 mtr. long (Tee off) with PP,clamp, Bolt and nuts all galvanized as per SBD specs
MS Channel 100x50x6mm, 2.800 mtr. Long (for Transformer Base) with all fixing arrangment PP,Clamps,Nuts & Bolts all galvanized as per SBD specs
11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch with 2 Nos. MS channel 100x50x6mm PP, clamps ,Bolt and nuts all galvanized as per SBD specs
Transformer Belting Angle 50X50X6mm with all fixing arrangment PP,Clamps,Nuts & Bolts all galvanized.
11 kV Drop out fuse set for Transfoermer With MS Channel 100x50x6mm 1 no. 2.8 mtr. Long,PP , Clamp,Nuts&Bolts all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc. Fittings B&S type 45 KN
ACSR Rabbit Conductor with 3 % Sag
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
11 kV Danger Board with GI clamp Bolts & Nuts
9KV, 5KA Outdoor type Lighting Arrester Polymer.
Chemical Earthing(with GI Strip 25x3mm for Neutral Earthing of Transformer
Chemical Earthing of Transformer Body(with GI strip 25x3mm),Other structure& Equipment( with GI Wire of 8 SWG)
Chemical Earthing of Lightning Arrestor with GI Strip 25x3mm
Aluminum lugs HT side
Aluminum crimping lugs LT side
70 Sq.mm.,single core `XLPE insulated un-armoured aluminium conductor cable
120 Sq.mm.,single core `XLPE insulated un-armoured aluminium conductor cable
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Red Oxide paints
Aluminum paint (Double Coat)
Stays Complete (As Per Annex. F-15 )
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of Aged DTR Structure with all worn out Accessories including Loading/Unloading Complete Work.
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Clamps for LT Take off with bolts and nuts all galvanized.
MS Channel 100x50x6mm, 2.800mtr. long (Top Channel) with all fixing arrangment PP, Clamps, Nuts & Bolts all galvanized as per SBD specs
MS Channel 100x50x6mm, 1.300 mtr. long (Tee off) with PP,clamp, Bolt and nuts all galvanized as per SBD specs
MS Channel 100x50x6mm, 2.800 mtr. Long (for Transformer Base) with all fixing arrangment PP,Clamps,Nuts & Bolts all galvanized as per SBD specs
11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch with 2 Nos. MS channel 100x50x6mm PP, clamps ,Bolt and nuts all galvanized as per SBD specs
Transformer Belting Angle 50X50X6mm with all fixing arrangment PP,Clamps,Nuts & Bolts all galvanized.
11 kV Drop out fuse set for Transfoermer With MS Channel 100x50x6mm 1 no. 2.8 mtr. Long,PP , Clamp,Nuts&Bolts all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc. Fittings B&S type 45 KN
ACSR Rabbit Conductor with 3 % Sag
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
11 kV Danger Board with GI clamp Bolts & Nuts
9KV, 5KA Outdoor type Lighting Arrester Polymer.
Chemical Earthing(with GI Strip 25x3mm for Neutral Earthing of Transformer
Chemical Earthing of Transformer Body(with GI strip 25x3mm),Other structure& Equipment( with GI Wire of 8 SWG)
Chemical Earthing of Lightning Arrestor with GI Strip 25x3mm
Aluminum lugs HT side
Aluminum crimping lugs LT side
70 Sq.mm.,single core `XLPE insulated un-armoured aluminium conductor cable
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Red Oxide paints
Aluminum paint (Double Coat)
Stays Complete (As Per Annex. F-15 )
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of Aged DTR Structure with all worn out Accessories including Loading/Unloading Complete Work.
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Clamps for LT Take off with bolts and nuts all galvanized.
MS Channel 100x50x6mm, 2.800mtr. long (Top Channel) with all fixing arrangment PP, Clamps, Nuts & Bolts all galvanized as per SBD specs
MS Channel 100x50x6mm, 1.300 mtr. long (Tee off) with PP,clamp, Bolt and nuts all galvanized as per SBD specs
MS Channel 100x50x6mm, 2.800 mtr. Long (for Transformer Base) with all fixing arrangment PP,Clamps,Nuts & Bolts all galvanized as per SBD specs
11 kV, 3-ph, 400 A, 3 Pin type, Horizontal/Vertical Mounting type, Gang Operated, AB Switch with 2 Nos. MS channel 100x50x6mm PP, clamps ,Bolt and nuts all galvanized as per SBD specs
Transformer Belting Angle 50X50X6mm with all fixing arrangment PP,Clamps,Nuts & Bolts all galvanized.
11 kV Drop out fuse set for Transfoermer With MS Channel 100x50x6mm 1 no. 2.8 mtr. Long,PP , Clamp,Nuts&Bolts all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc. Fittings B&S type 45 KN
ACSR Rabbit Conductor with 3 % Sag
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
11 kV Danger Board with GI clamp Bolts & Nuts
9KV, 5KA Outdoor type Lighting Arrester Polymer.
Chemical Earthing(with GI Strip 25x3mm for Neutral Earthing of Transformer
Chemical Earthing of Transformer Body(with GI strip 25x3mm),Other structure& Equipment( with GI Wire of 8 SWG)
Chemical Earthing of Lightning Arrestor with GI Strip 25x3mm
Aluminum lugs HT side
Aluminum crimping lugs LT side
35 Sq.mm.,single core `XLPE insulated un-armoured aluminium conductor cable
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Red Oxide paints
Aluminum paint (Double Coat)
Stays Complete (As Per Annex. F-15 )
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of Aged DTR Structure with all worn out Accessories including Loading/Unloading Complete Work.
Replacement of Damaged Pole's
33KV feeders
STP Pole SP-55
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
9.0 M PCC Poles
PCC Pole 9.0 Mtrs. Long
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
11KV feeders
ST POLE SP-33
Steel Tubular Poles 9 m long (STP 9.0 M, 410 MPa , SP-33) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
9.0 M PCC Poles
PCC Pole 9.0 Mtrs. Long
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
LT Lines
STP Pole SP-21
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Aluminum paint (Double Coat)
Red Oxide paints
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
8.5 M PSCC poles
PCC Pole 8.5 Mtrs. Long
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
Damaged Double Poles structures
33 KV Line DPs
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV top channel 125x65x6mm 3.2 mtr. Long with all fixing arrngement, PP, Clamp, bolts & nuts all galvanized.
33 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
33 kV Polymeric Pin Insulator complete
GI Fish Plate 50x8mm for 33 kv DP.
33kV Disc fitting for Panther/Dog/Raccoon/Rabbit conductor 90/70/45 KN B&S type
33 kV Composite Polymer Disc Insulator B & S type
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
PG clamp/Wedge type for HTLS/Panther/Dog / Racoon conductor
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Pole, Clamps, insulator and accessories etc. including Loading/Unloading Complete Work.
11 KV Line DPs
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
11 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
11 kV Polymer Pin Insulator with Pin complete.
GI Fish Plate 50x8mm for 11 kv DP
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc Fittings B&S type 90/70 KN for ACSR Dog/Raccoon
11 kV Danger Board with GI clamp Bolts & Nuts
PG clamp/Wedge type for ACSR Dog/Raccoon / Rabbit
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Double Pole, Clamps, insulator Structure and accessories etc. including Loading/Unloading Complete Work.
Damaged Four Poles structures
33 KV 4 pole structure
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV top channel 125x65x6mm 3.2 mtr. Long with all fixing arrngement, PP, Clamp, bolts & nuts all galvanized.
33 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
33 kV Polymeric Pin Insulator complete
33 kV E Clamp made of MS Channel (100X50X6)mm with Bolts & Nuts all galvanized.
33kV Disc fitting for Panther/Dog/Raccoon/Rabbit conductor 90/70/45 KN B&S type
33 kV Composite Polymer Disc Insulator B & S type
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
PG clamp/Wedge type for HTLS/Panther/Dog / Racoon conductor
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Double Pole, Clamps, insulator Structure and accessories etc. including Loading/Unloading Complete Work.
11 KV 4 pole structure
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
11 kV top channel 100x50x6mm 2.2 mtr. Long with PP & clamp, nuts & bolt all galvanized as per SBD specs
11 KV Cross bracing Set 50x50x6mm with Belting angle of 65x65x6mm with clamps bolts & nuts all galvanized, as per SBD
11 kV Polymer Pin Insulator with Pin complete.
GI Fish Plate 50x8mm for 11 kv DP
11 kV Compsite Polymer Disc Insulator B & S type
11 kV Disc Fittings B&S type 90/70 KN for ACSR Dog/Raccoon
11 kV Danger Board with GI clamp Bolts & Nuts
PG clamp/Wedge type for ACSR Dog/Raccoon / Rabbit
Stay complete (As per Annex-C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Aluminum Binding wire & tape
Aluminum paint (Double Coat)
Red Oxide paints
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dismantling of existing Four Pole, Clamps, insulator Structure and accessories etc. including Loading/Unloading Complete Work.
Sign Board
Sign Board 1 No.in each town 6x4 feet (lengh x breadth) as per SBD.
Sign Board 1 No.in each town 6x4 feet (lengh x breadth) made of MS sheet 14 Gauge(1.6mm thickness) with angle suport of (3"x3",6mm) and height of board 6 feet fromm ground level to bottom of board and length of angle to be buried in the ground 1.50 feet with 1 feet hole pass inside,painting on board ( enamel paint with red oxide base coat)and printing on board (colour printing by Screen printing method)
Mishrilal Associates Pvt. Ltd.
VIBHOR VAIBHAV INFRA PVT LTD
Suncity Urja Private Limited
Mishrilal Associates Pvt. Ltd.
Mishrilal Associates Pvt. Ltd.
VIBHOR VAIBHAV INFRA PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid