Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC KORAMANGALATH HOUSE TOMY LANE SOUTH PANAMBILLY NAGAR KADAVANTHRA P O KOCHI 682 020 | KOCHI | ERNAKULAM | KERALA | 682020 | ₹29.0 L Quoted ₹29.3 L | L1 | Accepted-AOC lowest Tender |
| 2 | L2₹31.9 L+₹2.5 L (8.66%)Rejected-Finance DOOR NO 42 2237 KRISHNA BEHIND ERNAKULAM MEDICAL CENTRE CENTURY CLUB ROAD VENNALA KOCHI 682028 | KOCHI | ERNAKULAM | KERALA | 682028 | ₹31.9 L+₹2.5 L (8.66%) | L2 | Rejected-Finance Other than lowest tender |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
15 Dec 2020, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi, 682 004
REPAIR /MAINTENANCE OF FIRE ALARM AND DETECTION SYSTEM FIXED FIRE FIGHTING SYSTEM AND OUTSOURCING SERVICES FOR E/M INSTALLATIONS AT INS GARUDA
2020_MES_399454_1
8744/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Kochi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹74,000
Yes
19 Jan 2021
30 Nov 2020
17 Dec 2020
30 Nov 2020
15 Dec 2020
1 Dec 2020
Amount
Providing services for operation of water supply installation from 0600 to 2200 hours at NAY (K) Garuda pump house consisting of fresh water pump sets and valves including monthly maintenance of pumps, valves & all allied equipments and allied works including pumping and distribution of fresh water to entire NAY (K) and Garuda area and carry out minor repair as and when required to all machines / equipments and valves to ensure 100% serviceability of plants and removing grass/surface dressing from surrounding area, including all Sundays and Holidays for operation complete all as specified.
Providing services for operation of 900 Men Pump House round the clock consisting of fresh water pump sets and valves including monthly maintenance of pumps, valves & all allied equipments and allied works including pumping and distribution of fresh water to Virat Block, 900 Men block, Tejas Block and Dhruva block and in living barracks of NIAT and carry out minor repair as and when required to all machines / equipments and valves to ensure 100% serviceability of plants and removing grass/surface dressing from surrounding area including all Sundays and Holidays for operation of water supply installation complete all as specified.
Providing services for operation of fire fighting pump house installation located at 550 Squadron Garuda from 0600 to 2200 hours comprising of following equipments/ machines including testing and operation of valves including monthly maintenance of pumps, valves & all allied equipments and allied works including all Saturdays/ Sundays/ holidays for operation of system as and when required and also to carry out minor repairs/ servicing/ rectification of faults as and when required to all machines/ Equipments and valves to ensure 100% serviceability of plants and removing grass/surface dressing from surrounding area complete all as specified and as directed. (a) Electric driven pump sets 75 HP - 1 No (b) Diesel engine driven set 85 HP - 1 No (c) Jockey pump set 12.5 HP - 1 No
Notes for Serial Item No 1 to 3:- The rates quoted shall deem to be included for the following:- (i) Removing grass from surrounding area of the water supply installation of an interval of fortnightly i.e. twice a month to make sure to cleaning the pump house area. (ii) Provide the cleaning material i.e. Jute for cleaning the pump sets ,phenyl for cleaning the bathroom, broom for cleaning and removing the spider nets from the bottom and corner of the roof/ wall of pump houses /installations. (iii) Clean inside and outside installations by broom daily basis including bathroom by phenyl to maintained hygiene sanitation. (iv) Daily cleaning of floor area and maintaining a good and hygienic sanitation around the installation. (v) All stationery items such as registers, log books etc should be provided by the contractor. (vi) Non providing of operator in a day by the contractor shall invite penalty of Rs 5000/- per day from his due amount. (vii) Minimum qualification for tradesman shall be ITI / ITC qualified Plumber / Electrician / mechanic / Fitter per one in each shift of 08 hours. Any other man power of helper shall be provided by the contractor as per site requirement. Rate quoted by the contractor shall be deemed to be included in the unit rate. (ix) Any Servicing material required for operation shall be deemed to be included in the quoted rate.
GST LIABILITY It is considered prudent to specify that the GST is included in the rates quoted against items of outsourcing as well as items of repairs/comprehensive maintenance to be paid separately under material and labour’ parts. MONTHLY WAGES Monthly wages shall be paid by the contractor to the workers/labour only online. Proof of statutory deductions in favour of workers/labour shall be submitted by the contractor to the Engineer in Charge along with RAR/Final Bill for verification. The contractor will be required to submit copy of valid labour licence from the Labour Commissioner within 15 days of commencement of the work BASIC RATE, EPF, ESIC, BONUS, OVER HEAD PROFIT, TAXES & LWC The bidder to quote basic rate, employer's contribution towards Employees Provident Fund (EPF) liability, contribution towards Employees State Insurance Corporation (ESIC), contribution towards bonus, overhead and profit and labour welfare cess (LWC) separately, as applicable depending upon the manpower requirement. This will create onus on the contractor to ascertain the relevant rates and quote accordingly. The rates quoted shall be inclusive of all taxes, cess, and levies as applicable including GST as prevailing applicable law. Contractor shall be sole liable for the same.
Material & Labour for attending of breakdown in Fire Detection, Alarm System and Fire Fighting System at INS Garuda Area, detection of nature of defect including carry out minor repairs, loose connection, change of small length of wire as required size to make the machine/equipment functional, opening of switch board / panel board and re fixing the same after necessary repair, etc complete all as specified and directed. Notes: - (a) The unit rate quoted shall be deemed to be included the elements of labour only for rectifying and making the machine functional for minor repair. If replacements of parts / items is required to make the equipment/machine functional the cost of labour and material for the same shall be measured and paid for as " S & F in repairs/ M & L for" under relevant items of this schedule hereinafter. (b) Contract shall run for minimum period as specified and completion will not be issued prior date of completion as mentioned in Work Order No-01. (c) If breakdown shall not be attended & rectified the same day as received by the contractor except rewinding of Motor and other major spares as specified , the recovery will be made @ Rs.1000/- per breakdown per day. And after 15 days of nonfunctional of any machine as specified for any reason the recovery will be made @ Rs. 2000/- per day till the machine operational.
S & F in repair gun metal fire hydrant 63 mm dia, single headed with flanged inlet and instantaneous out let on the existing stand post with brass nipple, including necessary bolts, nuts and washers including taking down unserviceable old one complete, all as specified and as directed. Make : Essel/ Fire marshal/ SRI/ Ever safe/ Newage/ Aadi/ Fire cool
S & F in repair gun metal fire hydrant 63 mm dia, double headed with flanged inlet and instantaneous out let on the existing stand post with brass nipple, including necessary bolts, nuts and washers including taking down unserviceable old one complete, all as specified and as directed. Make : Essel/ Firemarshal/ SSRI/ Ever safe/ Newage/ Aadi/ Fire cool.
Supply & Fix in repair first aid hose reel, wall mounted swinging type complete with drum, bracket, globe valve/ stop cock of size 19 mm dia, 30 metre long high pressure hose reel tubing with branch pipe gun metal shut off nozzle including taking down unserviceable old one , all as specified and as directed. Note : - Hose reel shall be as per IS 884 and hose tubing as per IS 8090; Make : Eversafe/Newage/SRI/Mahveer
S & F in repair, 15 Mtr long rubber lined woven jacketed hose pipe 63 mm dia, type A (Reinforced rubber lined) as per IS 636 with necessary instantaneous spring lock type coupling at the ends to match with landing valve/hose pipe/branch pipe with gun metal male and female coupling conforming to IS 903 all as specified and as directed. Make : Newage/Essel/SRI/Ever Safe/Aadi/CRC
S & F in repair fabricated MS hose cabinet, made of 18 gauge MS sheet 800mm X 600mm X 250mm double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side brilliant white inside and including taking down unserviceable old one, all as specified and as directed.
S & F in repair 63 mm dia branch pipe gun metal instantaneous inlet and made of 15 mm bore nozzle short complete all as specified and as directed. Make : Newage/Essel/SRI/Ever Safe/Aadi/CRC
S & F in repair Fire brigade inlet connection 4 way valve ISI marked including taking down unserviceable old one , complete all as specified and as directed. Make : Newage/Essel/SRI/Ever Safe/Aadi/CRC
S & F in repair of Pressure switch Universal type complete all as specified and as directed. Make : Danfoss / Indfoss or equivalent approved make.
S & F in repair of Pressure Gauge, 100mm dial, 0 - 14 Kgs rating complete all as spcified and directed. Make : H Guru or equivalent approved make.
S & F in repair of 500 litres capacity ISI marked Rotational Moulded polyethylene water stroge tank (cylinderical Vertical with Close top ) hosisted and fixed in position complete all as spcified and directed. Make : Aqua Tech / Syntex
S & F in repair of 150mm bore of Cast Iron, butter fly valve , complete all as spcified and directed. . Make : AUDCO/C&R/INTERVALE
S & F in repair of 100mm bore of Cast Iron, butter fly valve , complete all as spcified and directed. Make : AUDCO/C&R/INTERVALE
S & F in repair 150mm bore cast iron Non Return valve with by pass arrangement including taking down unserviceable old one , complete all as spcified and directed. Make :- Kirloskar/Bir/Leader
S & F in repair 100mm bore cast iron Non Return valve with by pass arrangement including taking down unserviceable old one , complete all as spcified and directed. Make :- Kirloskar/Bir/Leader
S & F in repair 80mm bore cast iron Non Return valve with by pass arrangement including taking down unserviceable old one , complete all as spcified and directed. Make :- Kirloskar/Bir/Leader
S & F in repair 150 mm bore Cast iron sluice valve with flanged ends of type PN 1.6 conforming to IS 14846 with cast iron wheel and brass spindle , complete all as spcified and directed. Make :- Kirloskar/Bir/Leader
S & F in repair 100 mm bore Cast iron sluice valve with flanged ends of type PN 1.6 conforming to IS 14846 with cast iron wheel and brass spindle complete all as spcified and directed. Make :- Kirloskar/Bir/Leader
S & F in repair of 80 mm bore Cast iron sluice valve with flanged ends of type PN 1.6 conforming to IS 14846 with cast iron wheel and brass spindle , complete all as spcified and directed. Make :- Kirloskar/Bir/Leader
S & F in repair 150 mm Cast iron Foot valve including taking down from the suction side of pumpset from the sump and making good the distrubed complete all as spcified and directed. Make : Normex/Audco/Kirloskar/Bir/Leader.
S & F in repair 100mm Cast iron Foot valve including taking down from the suction side of pumpset from the sump and making good the distrubed complete all as spcified and directed. Make : Normex/Audco/Kirloskar/Bir/Leader.
S & F in repair 80mm Cast iron Foot valve including taking down from the suction side of pumpset from the sump and making good the distrubed complete all as spcified and directed. Make : Normex/Audco/Kirloskar/Bir/Leader.
S & F in repair 50mm gun metal, gate valve with iron wheel head, screwed both ends for iron pipe including taking down unserviceable old one complete all as spcified and directed. Make : Sankti/ NVI/ zew/ Atom.
S & F in repair of three pole power contactor MNX 140, 2NO+2NC for main pumpset complete all as spcified and directed. Make : L & T or equivalent as approved by GE
S & F in repair of three pole power contactor MNX-110, 2NO+2NC power contactor MNX 110 for Main pumpset complete all as spcified and directed. Make : L & T or equivalent as approved by GE
S & F in repair of three pole power contactor MNX-22, 1NO+1NC for pumpset complete all as spcified and directed. Make : L & T or equivalent as approved by GE
S & F in repair Electronic timer type ST 100 complete all as spcified and directed. Make : L & T or equivalent as approved by GE
S & F in repair of Push button with indicator (set of three R Y B) for panels complete all as spcified and directed. Make : L&T or equivalent approved by GE
S & F in repair 12 Volt 80 AH Self Charging Battery, complete all as spcified and directed. Make : Cummins/Exide or equivalent approved by GE
S & F in repair of CPVC pipe inner diameter 150 mm with CPVC schedule 40 pipes & plain schedule 80 fittings on walls / ceiling or laying in floors and jointed with CPVC primer & CPVC solvent cement including taking down unserviceable old one, complete all as spcified and directed.
S & F in repair of CPVC pipe inner diameter 100mm with CPVC schedule 40 pipes & plain schedule 80 fittings on walls / ceiling or laying in floors and jointed with CPVC primer & CPVC solvent cement including taking down unserviceable old one, complete all as spcified and directed.
S & F in repair of CPVC pipe inner diameter 80 mm with CPVC schedule 40 pipes & plain schedule 80 fittings on walls / ceiling or laying in floors and jointed with CPVC primer & CPVC solvent cement including taking down unserviceable old one, complete all as spcified and directed.
S & F in repair of Ductile Iron Pipes 150mm bore centrifugally cast (spun) including jointing in standard length, with flanged ends, Class "K9" conforming to IS 8329-2000 (latest version) in any length laid in trenches including taking down unserviceable old one , complete all as spcified and directed.
S & F in repair of Ductile Iron Pipes 100mm bore centrifugally cast (spun) including jointing in standard length, with flanged ends, Class "K9" conforming to IS 8329-2000 (latest version) in any length laid in trenchs including taking down unserviceable old one , complete all as spcified and directed.
S & F in repair of 150 mm bore GI tubing Heavy grade with all fittings laid in trenches or fixed to walls and ceilings or laying in floors, including taking down unserviceable old one , complete all as spcified and directed.
S & F in repair of 100 mm bore GI tubing Heavy grade with all fittings laid in trenches or fixed to walls and ceilings or laying in floors, including taking down unserviceable old one , complete all as spcified and directed.
S & F in repair 80 mm bore GI tubing Heavy grade with fittings laid in trenches or fixed to walls and ceilings or laying in floors, including taking down unserviceable old one complete all as specified and as directed.
S & F in repair of DI fittings (pressure class K-9) such as bends, (any type, radius and angle), Tapers any type (straight bend, increasing, decreasing or double socket etc) Tee piece single branch "Y" junction double branch, cross (all socket or socket and spigot) collars, caps and plugs of size upto 150mm bore confirming to IS 9523-2000 including taking down unserviceable old one , complete all as spcified and directed.
Servicing and repairs to cast iron sluice valve of 80 mm size by removing spindle, gate and check nut, cleaning and refixing new gland packing and rubber gasket complete all as specifed and directed
Servicing and repairs to cast iron sluice valve of 100 mm size by removing spindle, gate and check nut, cleaning and refixing new gland packing and rubber gasket complete all as specifed and directed
Servicing and repairs to cast iron sluice valve of 150 mm size by removing spindle, gate and check nut, cleaning and refixing new gland packing and rubber gasket complete all as specifed and directed
S & F in repair of 100mm bore C I pipes with flanged end, centrifugaly cast, class "A" in any length, laid in trenches including taking down old unserviceable one, complete all as spcified and directed.
S & F in repair of 150mm bore C I pipes with flanged end, centrifugaly cast, class "A" in any length, laid in trenches including taking down old unserviceable one, complete all as spcified and directed.
M&L for carry out General Servicing and Maintenance to diesel engine driven pump / fuel ijection pump of capacity 70 to 90 HP including B check and service as per manufactures recommendation ,overhauling including repalcement of oil filter ,air filter ,gland packing ,diesel filter with replacement of O rings ,Engine Oil and toping up of Coolant up to required level etc which ever be required to making 100 % serviceabiltiy of the engine complete all as specified and as directed
Material and labour for disconnecting of suction and delivery pipe and electric connections, from three phase centrifugal pump sets motor of capacity 75 HP, and dismantling the pump sets complete from the foundation, strip opening the unserviceable motor at site to located the fault and transporting to the local work shop, Strip opening the motor and cutting/removing burnt out winding and rewinding the motor with as per existing original wire gauge super enameled copper wire including high quality 'F' class insulating material with heat resistant sleeves, sealing compound and varnishing and heating the stator upto varnish fully dry and testing the motor at work shop to the satisfaction of Engineer-in-charge. Coupled the motor with pump and installed at site as per existing position, Testing the pump set after completion of work complete all as specified and directed.
All as per item No 48 here in above, but of capacity 15 HP
All as per item No 48 here in above but of capacity 12.5 HP
M & L for Overhauling of Fire fighting pump, 75 HP capacity by cleaning, varnishing, heating, assembling, refixing in position and pump side replacing of stainless steel sleeve, gland packing, greasing etc, and testing complete all as specified and as directed.
M & L for Overhauling of Fire fighting pump, 15 HP capacity by cleaning, varnishing, heating, assembling, refixing in position and pump side replacing of stainless steel sleeve, gland packing, greasing etc, and testing complete all as specified and as directed.
M & L for Overhauling of Fire fighting pump, 3 Phese, 415 volt, 12.5 HP capacity by cleaning, varnishing, heating, assembling, refixing in position and pump side replacing of stainless steel sleeve, gland packing, greasing etc and testing complete all as specified and as directed.
Disconnecting Suction and delivery pipe lines from unserviceable Electric Driven / Engine Driven centrifugal pump from motor / Engine and opening the pump , cleaning , replacing the worn out part like - ball bearing , gun metal bush , pump shaft repair by lath, replacement / repairing of impeller by grinding / polishing ,water sealant of any type and necessary gland packing etc. which ever be required to making 100 % serviceable of pump sets coupled with motor and installed at site as per existing including testing after complete repairs of work all as specified and directed at site of capacity 75HP.
All as per item No 54 here in above but of capacity 15 HP
All as per item No 54 here in above but of capacity 12.5 HP
Disconnecting the three phase electric supply from panel board and taking out the burned wiring of panel board and unserviceable spare part like contactor, relays, timer, push bottom, NO/NC volts coil and thermal load relays etc and re-wring the panel board with new required size of wire and accessories which be required to make 100 % serviceability suitable for starter panel for pump set of capacity 10 to 30 HP.
All as per item No 57 here in above, but for 50 to 90 HP
S & F in repair Cast Iron Fittings upto 150mm dia such as bends (any type, radius and angle), tappers any type (straight, bend, increasing or double socket etc) tee pieces single branch "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs including taking down unserviceable old one all as specified and as directed.
Excavation in trenches not exceeding 1.5 M wide and n.exc.1.5m in depth for laying pipes etc and getting out in soft/loose soil
Returning/filling in soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick as specified.
Removing excavated materials (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 M above the starting point.
M&L for Painting to outer side of the existing feeder pillar board, panel board and fire fighting equipments, pipe lines by two coat of synthetic enameled paint of existing colour by using spray gun and compressor after making the surface ready to paint and all as per the direction of the Engineer-in-charge
Material and labour, for repair / replacement of worn out Gland Packing of pump set / sluice valves / hydrants any make / metal / size including washers of any shape / size to avoid water leakage as indicated including taking out old one complete all as specified and directed.
M & L for Reprogramming of Existing fire alarm system installed at Various location including loop Checking, Changing of Device Location Name and Address of the Room and preparing as build Drawing all as specified and directed.
S & F in repair addressable type multi sensor detector with smoke & Heat combination all as specified and directed. Make: Edward / GST/ Honey well / morley / Siemens.
S & F in repair addressable Sounder cum- storbe all as specified and directed. Make: Edward/GST/Honeywell/Morley/Siemens.
S & F in repair addressable remote response indicators all as specified and directed. Make : Edward/GST/Honey well / Morley / Siemens.
S & F in repair Manual call point resettable type all as specified and directed. Make : Edward/GST/Honey well/ Morley/Siemens.
S & F in repair addressable Monitor module for Beam detector all as specified and directed. Make: Edward/GST
S & F in repair addressable type heat detector with base, rate of temperature rise as per IS-2175 all as specified and directed. Make: Honey well / Morley.
S & F in repair addressable Beam master detector with transmitter and receiver all as specified and directed. Make: Honey well / Morley.
S & F in repair UV/IR Flame detector all as specified and directed. Make: Honey well / Morley.
S & F in repair addressable short circuit isolator all as specified and directed. Make : Honey well / Morley
S & F in repair 12 V 7 AH Battery all as specified and directed. Make: Exide /Amaron/Panasonic.
S & F in repair 12 V 12 AH Battery all as specified and directed. Make: Exide /Amaron/Panasonic.
S & F in repair 1000 VA UPS all as specified and directed. Make: APC /Intex/Su-Kam / V-guard.
S & F in repair only addressable Fire alarm Repeater panel all as specified and as directed. Make : Edward / GST / Honey well / Siemens
S & F in repair addressable Fire alarm control panel complying with BSEN54/UL single loop panel of capacity from 126 detectors & 126 modules all as specified and directed. Make : Edward/GST/ Honey well/Siemens
S & F in repair PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade all as specified and directed. Make : Polycab/Havells/Finolex/National
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
AAG INDIA PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .