Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC | ₹17.7 L | L1 | Accepted-AOC BEING LOWEST BIDDER |
| 2 | L2₹17.8 L+₹13,505 (0.76%)Rejected-Finance | ₹17.8 L+₹13,505 (0.76%) | L2 | Rejected-Finance NOT BEING L1 |
| 3 | L3₹19.4 L+₹1.7 L (9.46%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | ₹19.4 L+₹1.7 L (9.46%) | L3 | Rejected-Finance NOT BEING L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
2 Sept 2022, 6:00 pmClosed
GE KARGIL
MES OFFICE KARGIL LADAKH
GE-K-37-2022-23 - REPAIR AND MAINTENANCE OF EXTERNAL ELECTRIFICATION INCLUDING STREET LIGHTS AND E AND M INSTALLATION AND REPAIR AND MAINTENANCE OF TRANSFORMER AND ALIIED WORKS AT DRASS THASGAM ETC UNDER GE KARGIL
2022_MES_543260_1
GE/K-37/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DRAS
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KARGIL
₹50,000
Yes
13 Oct 2022
4 Aug 2022
5 Sept 2022
4 Aug 2022
2 Sept 2022
19 Aug 2022
Amount
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, not exceeding 10 sqm on plan and not exceeding 1.5Mtr in depth & getting out of soft/lose soil for taking out pipe & laying of pipe & getting out for diverting of CI pipe line complete all as specified and directed
Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick complete all as specified.
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I.
Factory made ISI marked un-reinforced precast cement concrete cable cover of PCC 1:1.5:3 type A-1, conforming to class LV, flat of size 250mmx150mmx40mm, laid dry over electric cable for protection all as specified.
Replacement of pin type insulator, composite/polymer one galvanised MS spindle, two GI washers and one GI nut, for 1100 volts grade, complete all as specified.
Replacement of pin type insulator, composite/polymer one galvanised MS spindle, two GI washers and one GI nut, for 11000 volts grade, complete all as specified.
Dismantling of old ACSR conductor or service feeder distribution span complete all as specified and as directed by Engineer-in-charge.
S&F in repair ACSR conductor of (weasel) 6/2.59, straching properly on insulators and binding with aluminium binding wires,jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span etc complete all as specified and as directed by Engineer-in-charge.
Dismantling of stay assembly cpmplete complete all as specified and as directed by Engineer-in-charge.
Stay assembly complete with GI stay rod 20 mm dia 1800 mm long, MS plate 230x230x6 mm, stay bow,loop insulator, PCC 1:3:6, connecting bracket of suitable MS flat and nut bolt washers etc complete all as specified in electrical plate No 1 of SSR Part-1 including taking out old stay assembly.
Dismantling of insluator of any type complete all as specified and as directed by Engineer-in-charge.
Loop type insulator composite/polymer one galvanised MS spindle, two GI washers and one GI nut, for 1100 volts grade, complete all as specified.
Loop type insulator composite/polymer one galvanised MS spindle, two GI washers and one GI nut, for 11000 volts grade, complete all as specified.
Disc type insulator composite/polymer one galvanised MS spindle, two GI washers and one GI nut, for 11000 volts grade, complete all as specified.
Supply and fixing of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp for 11000 volts
Supply and fixing of gang operated air break switch Triple pole, mechanically operated, mounted on composite/polymer insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps for 11000 volts
M & L LT UG cable 3.5 core x 95 sq mm 1100 Volts grade XLPE insulated , armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including,cable gland lugs/ thimbles/ ferrules including connecting, testing and commissioning complete for the following sizes including taking down existing LT UG cable of any size at site all as specified and as directed. Notes: (a) Excavation earth work and sand cushioning brick protectionand connected work etc. Shall be measured and paid separately under relevant item of schedule (b) Rate quoted deemed to include for cutting and removing of defective joints where required as directed.
All as per ser item No.18 but for 70 Sqmm 3.5 core
All as per ser item No.18 but for 50 Sqmm 3.5 core
All as per ser item No.18 but for 25 Sqmm 4 core
All as per ser item No.18 but for 16 Sqmm 4 core
All as per ser item No.18 but for 16 Sqmm 2 core
S & F in replacement of service wire 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm x 2 Core nominal cross section complete all as specified.
S & F in replacement of service wire 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sq. mm x 2 Core nominal cross section complete all as specified.
M&L in replacement of Boring of holes under road pavement hard standing by manual boring incl making good the disturbed surfaces complete all as specified and directed
M & L in replacement of Straight through joints heat shrink type suitable for 6 to 16 Sq. mm. x 3.5/4 core sizes of PVC/XLPE insulated and PVC sheathed armoured LT underground cable with aluminium conductors including joint kits and labour complete for making joints all as specified and as directed.
All as per Item No 21. but for 25 to 50 Sq. mm. x 3.5/4 core
S & F in replacement Al cable lugs of size 16 Sqmm as specified
S & F in replacement Al cable lugs of size 25 Sqmm specified
S & F in replacement Al cable lugs of size 35 Sqmm as specified
S & F in replacement Al cable lugs of size 50 Sqmm as specified
S & F in replacement Al cable lugs of size 70 Sqmm as specified
S & F in replacement Al cable lugs of size 95 Sqmm as specified
Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI strip 32x6 mm as earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge. CI cover with frame , 15 MM dia GI pipe light grade for protection of wire etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 5 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion.
S&F MCCB 400 Amps,4 pole, 415 volts, 50 KA rupture capacity with adjustable terminal & adjustable magneting setting
S&F MCCB 250 Amps,4 pole, 415 volts, 50 KA rupture capacity with adjustable terminal & adjustable magneting setting
S&F MCCB 160 Amps,4 pole, 415 volts, 35 KA rupture capacity with adjustable terminal & adjustable magneting setting
S&F MCCB 100 Amps,4 pole, 415 volts, 16 KA rupture capacity with adjustable terminal & adjustable magneting setting
S&F MCCB 63 Amps,4 pole, 415 volts, 10 KA rupture capacity with adjustable terminal & adjustable magneting setting
M&L in replacment of ON LOAD change over switch with sheet metal enclosure 415V , 4 pole of capacity 250 Amps including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed..
M&L in replacment of ON LOAD change over switch with sheet metal enclosure, 415V , 4 pole of capacity 315/320 Amps including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed..
M&L in Replacement of Danger notice plates, made out of 1.6mm thick MS sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 20X15 cm size, fixed as in repairs, complete all as specified and directed.
M&L in Replacement of Danger notice plates, made out of 1.6mm thick MS sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 25X20 cm size, fixed as in repairs, complete all as specified and directed.
M & L for rubber matting one side chequered and other side plain 19 mm thick insulated for 11000 Volts ISI Marked in standard size 2m x 1m including taking down the unserviceable all as specified and directed.
S & F in replacement of Digital Multifunctional Panel meter for measuring Voltage ( 0-500V min ) ,Current , P.F , etc including necessary P.T & C.T's with all connected acccessories all as specified and directed
S & F in replacement of Digital voltmeters 0-500V , with all connected accessories including connecting up and testing as all as specified
S & F in replacement of Digital Ammetr 0-600A (min) , with CT's, all connected accessories including connecting up and testing as all as specified
S & F in replacement of LED indicator lamp 240 V , with suitable colour Red/Blue/Yellow/Amber/Green and connected acccessories all as specified and directed.
S & F in replacement of push button switch with NO/NC contacts 415 V ,6A , with add on Aux Contacts and connected acccessories all as specified and directed
M & L for servicing of two pole structure complete including replacement of unserviceable jumpers with PVC 50 Sqmm aluminium cable single core , vice type connectors, bolts nuts washers connecting lugs/thimbles knife contacts, applying petroleum jelly to the moving as well as fixed contacts tightening all the connections for its smooth functioning and preparing the old painted surfaces of the structure such as poles, cross arms, bracing and supports clamps back plates complete painting of two coats of anticorrosive aluminium paint over a coat of redoxide zinc chrome primer and providing yellow and black paint from the ground level all as directed at site by Engineer-in-charge. Note: - No extra payment will be made for the spares required to keep the installation in satisfactory functioning through out the contract period other than given in the schedule.
Supply & Fix in replacement of Safety fuse capacity 20 Amps to 40 Amps.
M & L for repair/replacement of earth pit cover with pre moulded cast iron eart pit cover 300mm x300mm x 50mm , provision of funnel, wire mesh necessary excavation and earth work in any type of soil as earth pit complete all as specified and directed
Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-31 (9.00 meters) with 300 mm x 300 mm x 6 mm mild steel base plate continuously welded to poles, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection including taking down of old unserviceable existing pole any size any type ,complete all as specified and directed by the Engr-in-Charge.
M&L for Pole painting with two coats of black bituminous paint externally through out for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface of existing pole any size any type ,complete all as specified and directed by the Engr-in-Charge.
S & F in replacement of Cable junction box of size not more than 250x150x75 mm with 6 Amp MCB SPN and bus bar fixed along the wall/pole without removing and preparation of surfaces for painting externally. Painting the cable junction box complete externally by applying one coat of synthetic enamel paint of approved colour , complete all as specified and directed by the Engr-in-Charge.
M & L for laying earth continuity conductor GI Strip 32 x 6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for direct/loop earthing with proper PVC/Porcelain insulator etc all as specified and directed .
Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete,complete all as specified and directed by the Engr-in-Charge.
Plain cement concrete 1:3:6 type C-1 (using 20mm grade aggregate) as in coping including all necessary form works complete all as specified and directed by Engineer-in-Charge
GI tubes galvanised iron light grade 40 mm bore laid in trenches/across roads/alongwith walls/poles as protection to cables and including taking down of old unservicable GI tubing,complete all as specified and directed by the Engr-in-Charge.
Supply and fix PVC conduit pipe 25mm dia heavy duty secured to poleswith necessary clamps and fitting such as bolts, nuts fixed in repairs all as specied and as directed
S & fix in replacement GI pipe 40 mm bore, light grade, 1.50 metres long, bent to shape required as in street light brackets, fixed to poles/ walls with suitable size MS clamps, nuts & bolts complete, all as specified and as directed.
Sheet metal enclosure for DB’s, single door single pole and neutral, 240V, 8 way with 200 Amp rated bus bar including blanking plates where required, complete all as specified and directed by the Engr-in-Charge.
MCB, Triple pole and neutral, 63 Amp, 240 volts, 10 KA , complete all as specified and directed by the Engr-in-Charge.
MCB, single pole, 40 Amp, 240V, 10 KA, complete all as specified and directed by the Engr-in-Charge.
S & Fix in replacement of LED Flood light fitting 70 watt 5000 k green/natural white , IP>66 ,grey powder coated die cast aluminium housing , inbuilt energy efficent surge protected electronic driver, with all connected accessories all as specified and directed .
S & Fix in replacement of High power LED Street light fitting 35 watt 5000 k, IP>66 , IK>07 grey powder coated die cast aluminium housing , inbuilt energy efficent surge protected electronic driver, with all connected accessories all as specified and directed .
S & Fix in replacement of High power LED Street light fitting 70 watt 5000 k, IP>66 , IK>07 grey powder coated die cast aluminium housing , inbuilt energy efficent surge protected electronic driver, with all connected accessories all as specified and directed .
M & L inreplacement of sub main wiring from street light to junction box with two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 1.5 sqmm in and including heavy grade PVC conduit and its accessories with fixing arrangements on pole surface, wall, ceiling etc including 1.5 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC conduit and two run of copper conductor together taken as one length for measuring unit length.
Earthing complete with steel earth plate electrode 600mmx600mmx6mm thick buried directly in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connecting to the galvanised iron earth wire 4.0mm dia by means of bolts, nuts, check nuts and washers of GI and steel earth wire including provision of concrete pit made from PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in pit, angle iron 25x25x6mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 15mm bore up to 7.5m length for drawing in earth lead wire, salt, charcoal, etc. including excavation and earth work in any type of soil, removal of surplus spoil to a distance not exc. 50m complete all as shown in electrical plate No.3 of MES Schedule 2009 (Pt-I) and connected to earth test point all as specified including testing on completion.
Supply and installation erection commissioing and testing of main LT pannel cubical out door type weather/dust proof, factory made out of 3.15mm thick CRCA sheet powder coated with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system includign four pole aluminium bus bar 400 amps capacity including control wiring with suitable size of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following:- MCCB 4 pole 415 volts 160 Amps, 35 KA - 01 No MCCB 3 pole 415 volts 125 Amps, 25 KA - 03 Nos Ammeter 0-400 Amps, size 4"x4" digital along with suitable size CT's-03 Nos( one per Phase)-03 Nos Volt meter 0-500 volts size 4"x4" digital - 01 No LED indicator lamp(RYB) - 01 Set
Supply and replacement of HT coils made out of super enamelled copper winding wires of same guage and same no of turns as required as per transformer of any capacity including replacement of paper insulation ,insulating meterial and proper end connection .The rewinding oil shall be heat treated in an electric oven complete as directed. Copper wire shall be 99.9 % pure and ISI Marked
Supply and replacement of LT coils made out of super enamelled copper winding wires of same guage and same no of turns as required as per transformer of any capacity including replacement of paper insulation ,insulating meterial and proper end connection .The rewinding oil shall be heat treated in an electric oven complete as directed. Copper wire shall be 99.9 %pure and ISI Marked
Painting of transformer of any capacity indoor/outdor type after cleaning the outer surface of the transformer by rubbing with emery paper ,remove oil particles, dust etc and applying one coat of synthetic enamel paint of smoke gray colour as directed
Supply and replacement of HT (11KV) Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity of 100 KVA
Supply and replacement of LT (433V) Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity of 100 KVA
Supply and replacement of Breather assembly of approved make filled with silica gel suitable for transformer of Transformer capacity of 100 KVA
Supply and replacement of High quality core gasket for transformer top lid cover for Transformer capacity of 100 KVA
Replacement of Top up transformer oil of die electric strength not less than 40 KV at 4 mm gap conforming to relevent IS complete all as specified and directed by the Engr-in-Charge
Disconnecting LT connection from the Transformer and transporting to workshop for repairs and shifting the transformer back to existing two pole structure of 100 KVA and connecting up complete (The rate included the rates fixing arrangements, any type of clamps, connection meterial as anything required at site) (Any type of damage of transformer while shifting will be the responsibility of contractor)
Note :Deduction for amount of Rs 76,803.00 as listed in Schedule A Part - II ( Schedule of Credit) shall be made while awarding of contract.
M/S HAJI HASSAN ENGINEERING WORKS
SUMEET TRADING CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .