Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹17.1 L+₹2.1 L (14.0%)Rejected-Finance R O NAUSHERA DISTT RAJOURI J K 185151 | NAUSHERA | RAJOURI | JAMMU AND KASHMIR | 185151 | L2 | Rejected-Finance Other than L1 |
Tender Value
₹13.9 L
EMD Value
₹27,820
Closing Date
2 May 2022, 6:00 pmClosed
MAJ SUBIN POULOSE
GE NORTH AKHNOOR PIN 181201
PROVN OF MT VEHICLE PARKING SHED AT SUNDERBANI MIL STATION UNDER GE NORTH AKHNOOR
2022_MES_516650_1
GE(N)AKH-01/2022-23
Open Tender
Civil Works
Works
180 days
SUNDERBANI
Class E Cat a i b i
8 documents required · 8 mandatory
₹500
GE NORTH AKHNOOR
₹27,820
29 Jun 2022
5 Apr 2022
4 May 2022
5 Apr 2022
2 May 2022
18 Apr 2022
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of soil as directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m deep in any type of soil and getting out complete.
M&L Cement concrete in foundations, filling and mass-concrete Type D2, 1:4:8 (using 40 mm graded stone aggregate) as in sub base complete all as specified & directed.
M&L for TMT Bar 10mm dia bar and over cut to length bent to shape required including cranking bending hooking ends binding with and including mild steel wire (annealed) not less than steel wire 0.9mm dia or securing with clips and conforming to Fe 410-S and 310-0)
M&L for TMT Bar 6 to 8mm dia bar and over cut to length bent to shape required including cranking bending hooking ends binding with and including mild steel wire (annealed) not less than steel wire 0.9mm dia or securing with clips and conforming to Fe 410-S and 310-0)
M&L for RCC design mix M-25 as Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc: basement slabs, under-reamed piles and mass concrete.
M&L for RCC design mix M-25 as in Columns, pillars, piers, posts and struts complete all as specified & directed by Engr-in-Charge.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and sofftits (if any) of foundation and plinth beams and similar work; vertical or to batter for fair finished surfaces all as specified & directed by Engr-in-Charge.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces all as specified & directed by Engr-in-Charge.
Excavation in post holes (or similar holes) in any type of soil, each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified.
M&L for Cement Concrete in post holes type C-2, 1:3:6 using 40mm graded stone as in foundation, filling and mass concrete complete all as specified and directed.
Removal of surplus soil to a distance no exc. 50 mtr and depositing where directed at a level n exc. 1.50 mtr above the starting point all as specified and directed by Engr-in-charge
Returning and filling including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified
M& L for hardcore broken stone or boulders of gauge n exc. 63 mm but n.exc 100mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for sand filling under floors or in foundation including watering and consolidation as sand cushioning 50mm thick complete all as specified and as directed by Engineer-in-Charge.
M&L for 80mm thickness M-40 grade machine pressed precast concrete interlocking paver block any shape and size conforming IS 15658-2006 with grey cement and pigment complete all as specified and directed.
M&L for 50 mm thick 75 cm wide PCC type C-1 1:3:6 (using 20mm graded stone aggregate) as in plinth protection laid in bays complete including 75mm thick consolidated hard core of broken stone over rammed earth finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and as directed by Engineer-in-Charge. Note :- The rate quoted shall be deemed to include for use and waste of form work / screed strips and to divide the area in panels including hardcore.
S&F for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 including notching, drilling, fitting, riveting and or welding or connecting with bolts and nuts including rivets or nuts and bolts ,providing and fixing cleats fish plates, gusset plate etc and also for wedging , plumbing, turning up and fixing complete all as specified and directed by Engineer-in-Charge.
S&F for Rolled sections as in main and cross beams, hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors;fixed with angle cleats or other connecting plates
M&L for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary gusset plates, riveting etc and exc 10 kg each brackets, conforming to Fe.290 GdeE-165 (Brackets over 10 kg each to be measured under "Structural steel"
M&L for preparation of new steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for brick work with sub class 'B' brick straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 all as specified
M&L for rendering 15mm thick cement plaster CM 1:4 on fair faces of brick work including finishing surfaces fair and even (without using extra cement) complete all as specified .
M&L for rendering 15mm thick on other than fair faces of brick/concrete or stone masonary surfaces in CM 1:6 finished even & smooth without using extra cement.
M & L Preparing new treated surfaces of walls and applying two coats of cement base paint over a coat of chalk whitening complete all as specified and directed.
M&L preparing of new plasterd surfaces of walls and apply two coat of white washing over one coat of chalk whiting complete all as specified and directed. .
M&L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof overing/ cladding to wall, fixed with self tapping screws incl ridge complete all as specified & directed by Engineer-in-Charge.
S&F point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC casing and caping 'ISI marked' of 20/30mm size as required, terminated in MS sunken box suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories, fixing arrangements on wall /roof/floor by means of drilling by heavy duty hand drill and fixing with PVC rawl plug and screws including single core FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan point controlled by one way switch, complete all as specified & directed. .
All as per Srl item No. 28 here-in-above but for one 5 pin 6 Amps socket outlet on same board with other switches.
S&F point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 2.5 Sqmm drawn into and including PVC casing and caping 'ISI marked' of 20/30mm size as required, terminated in MS sunken box suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories, fixing arrangements on wall /roof/floor by means of drilling by heavy duty hand drill and fixing with PVC rawl plug and screws including single core FRLS PVC insulated unsheathed multi stranded copper conductor cable of 2.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 15 Amps independent, complete all as specified & directed.
S&F switch piano, flush button 5 Amps, single pole one way.
S&F lamp holder, insulated body with back plate for batten fitting.
S&F Energy saving 10W LED bulk head luminaires, IP-65, oval shape, surface mounted with all other accessories prewired and making connections with copper flexible twisted twin cord of appropriate gauge and length, 230v, 50Hz complete all as specified & directed. Make. Havells, Cat Part No. RUGBYNEONFT10WLED760SSYMBOPC or equivalent in Philips/ Crompton/ Bajaj
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light 20W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F socket outlet, 2 in 1, 5 pin, 5 Amps, universal type, ISI marked, complete all as specified & directed.
S&F switch socket combination 2 in 1, 3 pin and 5/15 Amps, flush type universal complete all as specified & directed.
Supply and fixing ceiling fans complete with blades. Down rods, electronic regulator and accessories, 230 volt, 1200mm sweep, min air delievery 210 CFM with service value 6 BEE five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply, laying and testing XLPE insulated, electric cable (heavy duty) with stranded aluminium conductor, 1100 volts grade, heavy duty cable, cross-sectional area 10 Sqmm 2 core laid in trenches or passing through pipes complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
S&F ceiling rose, surface bakelite 65 x 50mm, two to three terminals
M&L complete for MCB distribution board, sheet steel, phasphatised powder painted with busbar neutral link, earth, bar and din rail conforming to IS 13032 & IS 8623 SPN 08 way double door complete all as specified and directed.
S&F in replacement MCB, single pole & neutral, (SPN) 50to 63 Amp, AC, 10 KA repturing capacity, ISI marked 240 Volt, 'C' series, including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified & directed.
S&F in replacement MCB, single pole, (SP) 6 to 32 Amp, AC, 10 KA repturing capacity, ISI marked, 240 Volt, 'C' series, including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified & directed by Engineer-in-Charge.
S&F Earthing of galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 15mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electrical plate No 3 of SSR Part-I (2009) with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr, including testing on completion, complete all as specified & directed. Note : (a) The cost of earth work, PCC pit of size shown in electrical plate No.3, funnel, watering pipe, wire mesh, charcoal, dust, common salt, 20mm bore medium grade watering pipe & 15mm bore light grade GI pipe as protection to earth lead wire etc shall be deemed included in the unit rate for earthing. (b) After completion, during testing, if the earth resistance equal or less 2 ohms is not obtained, earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
vijay kumar
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .