Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC | L1 | Accepted-AOC Admitted | |
| 2 | L2₹34.4 L+₹81,202 (2.42%)Rejected-Finance 204B SENTHAMANGALAM GOTHANDARAMPURAM VILLAGE PERUMANADU POST VAYALOGAM VIA PUDUKKOTTAI DIST TN | PUDUKKOTTAI | TAMIL NADU | 622104 | L2 | Rejected-Finance Being Not the Lowest Tenderer |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
13 Apr 2024, 6:00 pmClosed
GE Wellington
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
SPECIAL REPAIRS IN OR SINGLE LIVING ACCN IN BLOCK III AT 117 INFANTRY BATTALION TERRITORIAL ARMY THE GUARDS AT TRICHY UNDER GE WELLINGTON
2024_MES_645893_1
8887/E8
Open Tender
Civil Works
Item Rate
180 days
TRICHY
As per Tender Documents
4 documents required · 4 mandatory
₹500
GE Wellington
₹73,000
Yes
11 Dec 2024
11 Mar 2024
20 Apr 2024
12 Mar 2024
13 Apr 2024
25 Mar 2024
Amount
Taking down cement or cement lime plaster on brick/stone walls including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces of walls in Cement Mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
Rendering 10mm thick in cement mortar 1:6 as in backing coat and finishing coat in cement mortar 1:4 5mm thick using WPC compound @ 3% by weight of cement finished even and fair all as specified and directed. Note: WPC Shall measured and paid in relevent item.
Supply only integral proofing compound conforming to IS all as specified and directed.
Preparation of new plastered surfaces and applying two coats of exterior emulsion paint (Anti Fungal) white or tinted complete all as specified and directed.
Removal of old treated of plastered/ stone / brick wall surfaces and applying two coats of Exterior Emulsion Paint (Anti Fungal) white or tinted complete all as specified and as directed. Note: 1. Rates shall be quoted inclusive of required scafolding for a height upto 10 meters buildings.
Preparation of new plastered or unplastered surface of walls and applying two coats of oil bound distemper washable over a coat of primer using chalk whiting complete all as specified and directed.
Complete removal of existing treatment on plastered surfaces and applying two coats of oil bound distemper washable over a coat of primer using chalk whiting on wall surface complete all as specified and directed.
Demolition of Brickwork, stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed
Pre-cast cement concrete block masnory with solid block exceeding 10cm in width and setting in cement mortar 1:6 type C1 1:3:6 using 20mm graded stone aggregate complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding all as specified and directed.
Vitrified Ceramic tiles 10mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:4 all as specified and directed.
All as per item No 12 hereinbefore but on vertical surfaces including 10mm thick cement mortar 1:6 as in backing coat of dado/ skirting all as specified and directed.
Rotational moulded polyethylene water storage tanks, three layered ISI marked (cylindrical vertical with closed top) hoisted and fixed in position, 500 ltrs capacity complete all as specified and directed.
Ball brass valves high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed of dia 20mm all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for all as specified and as directed.
75 mm thick Plain Concrete Cement 1:3:6 type C2, using 40mm graded stone aggregate as in subfloor / sub base / plinth protection etc. all as specified and directed.
PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints laid in trenches or in floors all as specified and as directed.
PVC (SWR) 75mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
PVC (SWR) bends any radius, 110mm bore with oval access door complete all as specified and directed.
PVC (SWR) bends any radius, 75mm bore with oval access door complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5 Sqm and not exceeding 4Sqm each with shutters (without taking off shutters from the frames) all as specified and directed.
Taking down Shutter of any description of area exceeding. 1.5 sqm and not exceeding 2 sqm each all as specified and directed.
Taking down Shutter of any description exceeding 2 sqm each including builders hardware all as specified and directed.
2nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered put together with glue, pinned at joint all as specified and as directed.
35mm thick factory made, second class hardwood panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneer particle board with commercial veneering on both faces. The size of the rail and as per IS 1003 (Part -I) Kiln seasoned and chemically pressure treated all as specified and directed.
35mm thick second class hardwood glazed and skeleton door shutters open rebated and prepared to receive glass, gauze etc, (without sash bars), edges of framing plain, chamfered or rounded with cut and mitred beads for securing glass/gauges, size of members of shutter as specified in SSR Part-I section 8, clause 8.20 (a) complete all as specified and directed.
30mm thick second class hardwood glazed and skeleton door shutters open rebated and prepared to receive glass, gauze etc, (without sash bars), edges of framing plain, chamfered or rounded with cut and mitred beads for securing glass/gauges, size of members of shutter as specified in SSR Part-I section 8, clause 8.20 (a) complete all as specified and directed.
35 mm thick flush shutter,solid core construction, with block Board Core and plywood face panels, commercial type on both sides complete all as specified and as directed.
Cutting holes in brick walls/ stone walls built in cement mortar for inserting holdfast etc complete all as specified and as directed.
Mild steel flat iron work as in hold fast and similar small articles conforming to Fe-290 Gde-165 all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless wire staples as in repairs complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless wire staples complete all as specified and directed.
Sheet glass 4.0mm thickness ordinary quality and glazing with oil putty/ wooden beads in square n exc 0.5 sqm in each pane complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames, including punching or drilling out old glazing pins/ spring clips and providing and fixing new ones all as specified and directed.
Securing glass of any description in existing wooden frames glazed with putty/ beads including removing loose or decayed putty/ beads, painting / oiling one coat on rebates grooves, reputting and painting / oiling puttied to match existing work all as specified and directed.
Butt hinges 75mm size, medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
Butt hinges 100mm size, medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
Aluminium anodised, barrel tower bolts of extruded section 100 mm long all as specified and directed.
Aluminium anodised, barrel tower bolts of extruded section 200 mm long all as specified and directed.
Aluminium handles, cast type, anodised 100 mm long complete all as specified and directed.
Aluminium handles, cast type, anodised 150 mm long complete all as specified and directed.
300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring of 140mm overall length fixed in floor complete all as specified and directed.
Applying two coats of synthetic enamel paint over new wooden surfaces of any description not otherwise described over 10cm in width or girth over a coat of pink primer including preparation of surface complete all as specified and as directed.
Preparation of old painted wooden surfaces exceeding 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
Dismantling of single layer Mangalore pattern tiles or similar pattern tiles on roof all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed.
Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet as in ridge of 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws all as specified and directed.
Dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation boards / slabs / blankets, any thickness, including cover fillets and frame work all as specified and directed.
GI frame work for frame size 605mm x 605mm seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flages of 20mm and 30mm and web of 27mm fixed surrounding walls using Nylon sleeves and screws at 450mm c/c and intermediate channel 0.9mm thick having two equal flages of 15mm each and web of 45mm suspended from soffits at approx 900mm c/c with GI cleat and section not exceeding 1.2mtr length of 0.55mm thickness having kurb web of 50mm of and flanges of 26mm each with lips of 10.5mm fixed to intermediate channel with connection clips across the intermediate channel at 457mm c/c complete all as specified and directed.
Hangers 6mm dia G.I (upto 1200mm length) adjusting level fixed to roof slabs by means of ciling cleats made out of G.I flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed.
12mm thick Non asbestos fiber cement building board fixed in ceiling laid/ inserted to timber / GI/ Aluminium framework with screw complete all as specified and directed.
Preparing surface of wood and wood based material, steel and iron work, new or old of any description and grith not otherwise described and treated with tar or coal tar black paint all as specified and directed.
Dismantling of timber scantling, fillets, rails, posts, rafters, purlins, etc under 40sqcm and over in sections in any position in framed works all as specified and directed.
Second class hardwood scantling clean swan, as in roof members complete all as specified and directed
Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell etc, and making good disturbed surfaces with smooth finish matching with the existing surface of walls, floors, etc. and with existing colour all as specified and directed.
Taking down DBs/ Main switches of any make carefully and type including teakwood board / MS enlosure/ MCBs etc all accessories complete and making good the distrurbed surfaces and keeping aside for further disposals all as specified and directed.
Taking down sub main wiring of any size, type complete and making good the disturbed surfaces all as specified and directed.
Point wiring complete with and including 1.5 Sqmm (nominal area single core multi stranded FRLS copper conductor PVC insulated unsheathed cable 1100 volts grade ISI Marked drawn in and including non metalic rigid PVC conduit including accessories such as bend tees, junction boxes etc, and MS or anodised steel terminal boxes with 3mm thick laminated sheet covers for mounting fittings like switches, sockets and fan regulators etc with brass screws and cup washer including one run of 1.5 Sqmm PVC insulated and unsheathed multi strand copper conductor as green colour earth wire connected to common earh dolly for one light point controlled by one switch complete all as specified and directed
All as per item No 60 hereinbefore but one ceiling fan point controlled by one switch all as specified and directed.
All as per item No 60 hereinbefore but one exhaust fan point controlled by one switch all as specified and directed.
All as per item No 60 hereinbefore but one 3pin socket outlet 5A on same board all as specified and directed.
All as per item No 60 hereinbefore but one 3pin socket outlet 5A on independent board all as specified and directed.
All as per item No 60 hereinbefore but for 2.5 Sqmm size PVC insulated and PVC unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3/6 pin socket outlet 15 Amps on one independent board all as specified and directed.
Sub main wiring alongwith earth wire in and including surfce/ recessed PVC conduit with two runs of single core FRLS PVC insulated unsheathed cable 4 Sqmm (nomianl area) 1100 volts grade multistranded FRLS copper conductor with one run of 4.0 Sqmm PVC insulated unsheathed multistranded single core copper conductor 1100 Volts grade and connecting to common earth dolly. Note: Two runs of 4 Sqmm on erun of 2.5 Sqmm cable and on e run of PVC conduit of suitable size will measured and paid as one lenght.
Switch Piano flush button single pole one way 5 Amp 240V, 50Hz AC, ISI marked complete all as specified and directed
Switch socket combination 2 in 1, 3 pin 5 Amps flush type universal all as specified and directed
Switch socket combination 2 in 1, 3 pin 5 and 15Amps flush type universal all as specified and directed
Ceiling rose, 3 terminals PVC / polycarbonate, isolated body base plate ISI Marked all as specified and directed
Eectronic fan regulator step type, flush type suitable for fan 48'/ 56"mm sweep on the existing phenolic laminated sheet etc as required all as specified and directed.
Sheet metal enclosure for SPN DB 08 ways double door 240 Volts 200 amps rated bus bar all as specified and directed.
Sheet metal enclosure for SPN DB 04 ways double door 240 Volts 200 amps rated bus bar all as specified and directed.
Sheet metal enclosure for SPN single door DB 02 ways double door 240 Volts 200 amps rated bus bar all as specified and directed.
MCB 'C' curve type SPN 40Amps 10 KA 240 V all as specified and directed.
MCB 'C' curve type SPN 20Amps to 32 Amps 10 KA 240 V all as specified and directed.
MCBs SP 6 to 32 Amps 10 KA 240 Volt all as specified and directed.
LED ligth fittings (4 feet long) 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Lamp holder, angular type PVC/ Polycarbonate type with base plate/ PVC box ISI marked suitable for batten fittings of 230V all as specified and directed.
Cutting chases in brick/ stone masonary for concealed water tubing or concealed conduit for wiring etc. and making good, with same finishes as per existing with cutting exceeding 20cm grith all as specified and directed.
Taking down carefully ceiling fans/ exhaust fans of any sweep / size from Block-III Bldg from any height after disconnecting from the live line, transportation the same from site to workshop for repair including dismantling of the fan blases, motor, brackets for repairs and reassembling it complete after overhaulling oiling including greasing aftter replaceing unserviceable parts and refixing at original location including painting with one coat of synthetic enamel paint of white colour or any approved colour after cleaning the fan surface, fan blades, canopy and testing at site all as specified and directed. Note: Spare parts replaced except minor items eg screws, nut bolts washers, lock, clips lubicant and cleaning agent will be measured and paid separately as supply only" (ii) Rewinding of ceiling / exhaust fans will be measured and paid separately. (iii) Cost of rewriting of defaced MES / SM no shallbe included in quoted item rates.
Rewinding of ceiling fans 1200 to 1400mm sweep / wall mounted / pedestal fans of any size removed under SI item No 21 above including dismantling the ceiling fan motor and removing the burnt out winding cleaning the starter with CTC solution to remove the burnt slots. Rewinding the same with super enameled copper wire of suitable gauge and size / number of turns including insulation varnishing and reassembling completely all as specified and directed.
All as per Sl item No 82 hereinbefore but exhaust fan upto 450mm sweep any type / make all as specified and directed.
Supply only spare parts/ items of ceiling fans and exhaust fans of various types / makes to be incorporated under item No 81, 82 & 83 hereinbefore for repairs an d maintenance of Flexible twin twisted copper wire two core of size 23/0.0076mm upto 1.0 mtr length including flexible conduite exposed length of copper wire all as specified and directed.
All as per item No 84 hereinbefore but Ball bearing suitable for ceiling fan 1200/ 1400mm sweep all as specified and directed.
All as per item No 84 hereinbefore but Ball bearing suitable for exhaust fan 450mm sweep all as specified and directed.
All as per item No 84 hereinbefore but condensor 2.5mfd, 230V, suitablle for ceiling fan/ exhaust fan of any sweep and size all as specified and directed.
All as per item No 84 hereinbefore but PVC canopy top to bottom complete for ceiling fans down rod suitable for any size / sweep and any make all as specified and directed.
All as per item No 84 hereinbefore but Gun metal bushing ceiling fan 1200/ 1400mm sweep any make all as specified and directed.
Earthing complete with galvanised steel earth plate electrode size 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25m below normal ground level with top edge of earth plate not less than 1.5m below normal ground level connected to and incl GI earth lead wire 4mm dia by means of bolts ,nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and as specified or indicated and testing on completion incl excavation and earth work in any type of strata available at site ,PCC (1:3:6)type C-1 earthing chamber ,pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm, funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 15 mm bore light grade up to 7.5 mtr long, etc complete all as specified and directed.
Supply and fix in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire all as specified and directed.
Supply and fix ceiling fans complete with blades, down rods, electronic regulator or remote control with requisiting volt of DC batteries and accessories , 230V, 1200mm sweep. Minair delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed.
Supply and fix corrosion free, thermoplastiic body designed, sound less hybrid desert air cooler electric driven (single phase) 230V AC input, 50Hz havig nominal air delivery / flow capacity of 4000 CuM per hour (or nearest size) Hybrid pad (Honey comb + wood wool) cooling media, 3 noof speed controls, water tank capacity 55 Ltrs, 1350 RPM motor speed, ice chamber, 4 number castor wheels, auto louver movement water level indicator, dust filter, overflow indicator etc complete all as specified and directed. Make: Blue Star Cat Part No DA55PMA or other equivalent in Bajaj/ USHA/ Symphony
Supply and install hi wall split units indoor / outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for butter indoor air quality with minimum 4 star rating and EER 3.2 of capacity 2 TR Complete with all pipes and insulation etc all as specified and as directed.
Supply and fix Voltage Stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with out put voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA with digital display
XLPE insulated, armoured heavy duty electric cable with aluminium multi strands conductor, 1100 volts grade, cross-sectional area 25 Sqmm 3.5 core as directed for installation/ fixing on wall with suitable clamps and flexible PVC conduit of suitable dia complete all as specified and directed.
Sub main wiring with two runs of 6.0 Sqmm single core unsheathed PVC insulated multistranded copper conductor cable 1100V grade along with one run of 6.00 sqmm single core cable for earth continuity including PVC conduit pipe 25mm dia and accessories including taking down existing submain wiring complete all as specified and directed. Note: 2 runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as one unit length.
Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one 20A SP MCB all as specified and directed.
MCB/ Isolator TPN 415 Volts of capacity 100 Amps 'C' curve, 25 KA Complete all as specified and directed.
MCB SPN 240 Volts of capacity 32 Amps, 'C' curve complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.50M in depth; for foundation, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
Returning / Refilling of excavated soil including spreading leveling and well ramming in layers complete all as specified and as directed.
Removing the surplus soil to a distance not exceeding 50 meters from the starting point and depositing at a height not exceeding 1.5 m above ground level complete all as specified and as directed.
Supplying and laying reinforced precast concrete cable cover,Class LV, Type I, flat, size 250mm x 150mm x 40mm all as specified and directed.
Sand cushioning to PVC cable using clean dry riddled sand obtained from excavation or river sand gently punning below/around cable complete all as specified and as directed. Note: Punned thickness only will be measured.
GI tubing light grade, 40mm dia bore ISI marked conforming to IS 1239 for protection of cable fixed in wall or laid on trenches including removing taking down existing pipe complete all as specified and as directed.
M Govindarajan
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .