Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 01 DWARAN MOHARA BARAMULLA DWARAN MOHARA BARAMULLA BARAMULLA JAMMU KASHMIR 193122 | BARAMULLA | JAMMU AND KASHMIR | 193122 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹5.8 L
EMD Value
₹11,600
Closing Date
28 Feb 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer ED Baramulla
Executive Engineer ED Baramulla
Creation of 63kVA Sub Station at Gujjar Patti Lachipora of ESD Mohora
2023_PDD_205538_1
EDB/222
Open Tender
Electrical Works
Turn-key
15 days
Creation of 63kVA Sub Station at Gujjar Patti Lach
Please refer Tender documents.
3 documents required · 3 mandatory
₹501
Yes
Executive Engineer ED Baramulla
₹11,600
Yes
1 Mar 2023
18 Feb 2023
1 Mar 2023
18 Feb 2023
28 Feb 2023
20 Feb 2023
18 Feb 2023 - 20 Feb 2023
Amount
Supply,Carraige upto site, Installation, testing and Commissioning of 11/0.433KV,63KVA 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2(Pre-amended L2)
Supply,Carraige upto site, Erection, testing and commissioning of Steel Tubular Pole, 9 Mtr. Long Pole(ST-410 SP33) with planting depth of 1/5 th of the height of the pole, (9 mtr. Long )
Supply, Carriage up to site, Erection, testing and commissioning of Steel Tubular Pole, 8 Mtr. Long Pole(SP15) with planting depth of 1/5 the of the height of the pole, (8 mtr. Long )
Supply, Carriage up to site, laying ,stringing, tensioning , binding of ACSR Conductor, (30mm2 ACSR Conductor)
Supply,Carraige upto site, and fixing of GI Channel Iron x-arm 9' long 100x50x6mm including suitable clamps/collars (32 kg/No)
Supply,Carraige upto site, and fixing of GI Channel Iron x-arm 9' long 75x40x6mm including suitable clamps/collars (22 kg/No)
Supply, Carriage up to site, and fixing of GI V-Cross (75X40X6mm)& F-Top duly fabricated as per REC Standards including clamps(50x6 mm) & GI Nuts & Bolts (19 kg/No)
Supply, Carriage up to site, Installation, testing and Commissioning of GI Angle iron 9' length 50X50X6mm along with complete clamping arrangement (for Tranformer Belting) (16 KG/No)
Supply, Carriage up to site, Installation, testing and Commissioning of 11KV Polymeric composite pin insulators 12kV, 5kN, lightening impulse 75kV positive and 80kV negative , creepage distance 320mm
Supply, Carriage up to site, Installation, testing and Commissioning of 11KV Polymeric composite disc insulators 12kV, min falling load 45kN, lightening impulse 75kV positive and 80kV negative , creepage distance 320mm (1Set=3Nos.)
Supply, Carriage up to site, Installation, testing and Commissioning of 11KV G.O, AB switch 3-phase, 3pole,200Amp, vertical type
Supply, Carriage up to site, Installation, testing and Commissioning of 11kV Horn Gap Fuse Set 3 Phase 200A
Supply, Carriage up to site, Installation, testing and Commissioning of 11kV Gapless surge arrestor, 9 kV, 10kA, LA with polymer housing station type
Supply, Carriage up to site, Installation, testing and Commissioning of LT Distribution Box for 100kVA DTR with 160 MCCB 3P 16kA for incomer & 100Amp MCCB 3P 16KA 2Nos. for outgoing circuit.
Supply, Carriage up to site, Installation, testing and Commissioning of 185sqmm Single core cable 1.1kV Grade XLPE insulated Stranded conductor FRLS type
Supply, Carriage up to site, Installation, testing and Commissioning of Sundry items like Aluminium lugs, Jumpers, Binding tapes etc.
Supply, Carriage up to site, Installation, testing and Commissioning of LT structure mukhi type with shackles
Supply, Carriage up to site, Installation, testing and Commissioning of Galvanised Nuts & Bolts off sizes
Supply, Carriage up to site, Installation, testing and Commissioning of Galvanised stay set with 50X8mm stay clamp, guy insulator (02nos), anchor plate (200X200X6)mm nut bolts, 02nos turn buckle, 1.8m long, 16mm diameter solid GS stay rod & 7/3, 15mm dia GI stranded wire complete
Earthing of Sub Station --Excavation of earth pit dia 650mm & depth 3000mm, installation of earthing pipe pf 40mm nominal bore & 4mm wall thickness & length 2.5mtr long as per IS 1239. GI strip for neutral earthing of size 25mmX3mm for connection of transformer body, GO set & lightening arrestors as per IS 2629/85, GI nut & bolts refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover.
Supply, Carriage up to site, Installation, testing and Commissioning of Earthing complete by GI pipe 40mm 3mtr long through GI strip 25X3mm
Providing, carriage, transportation, Installation etc. of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole (Pit 600x600x1600 mm) for 9 MTR ST Pole
Providing & Painting of Poles with one coat of Red Oxide and two coats of aluminium paint and along with pole marking.
Supply, Carriage up to site, Installation, testing and Commissioning of danger Plates
Supply, Carriage up to site, Installation, testing and Commissioning of anti-climbing devices
Supply, Carriage up to site, Installation, of Sign Board (2X2 feet) along with required accessories like clamps, nuts and bolts etc.
MIR SONS ELECTRICALS
ALFA ENGINEERING SERVICES
Asif Engineering Works
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .