Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 CrAccepted-AOC HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹9.2 Cr | L1 | Accepted-AOC Being L1 and found in order |
| 2 | L2₹9.4 Cr+₹27.5 L (3.00%)Rejected-Finance 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | ₹9.4 Cr+₹27.5 L (3.00%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹9.5 Cr+₹31.4 L (3.43%)Rejected-Finance | ₹9.5 Cr+₹31.4 L (3.43%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹10.4 Cr+₹1.2 Cr (13.2%)Rejected-Finance 193 1 CIVIL LINES BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹10.4 Cr+₹1.2 Cr (13.2%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹10.5 Cr+₹1.3 Cr (14.2%)Rejected-Finance 15 16 GANGA COLONY KHATIPURA ROAD JAIPUR RAJ 302012 | JAIPUR | JAIPUR | RAJASTHAN | 302012 | ₹10.5 Cr+₹1.3 Cr (14.2%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹9.8 Cr
EMD Value
₹8.2 L
Closing Date
23 Mar 2024, 6:00 pmClosed
Chief Engineer Bareilly Zone
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243001
PROVN OF CERTAIN DEFICIENT OTM ACCN FOR ONE INF BN AT GARHI CANTT DEHRADUN
2023_MES_633114_1
CEBZ/DDN/T-13 OF 2023-24
Open Tender
Civil Works
Lump-sum
546 days
Dehradun
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE Project Dehradun
₹8.2 L
Yes
22 May 2024
16 Dec 2023
30 Mar 2024
16 Jan 2024
23 Mar 2024
15 Mar 2024
16 Dec 2023 - 23 Dec 2023
Amount
SCHEDULE A PART-I (BUILDING WORK)
Construction of Quarter Guard (Over 600 Men) (S/S) (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.
Construction of Storage Accommodation (S/S) (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.
Construction of Covered Accommodation for Light Specialist Veh ATGM & MMG (S/S) (RCC Framed Structure) along with APRON with permanent specification all as shown on drawings and as specified.
Construction of Covered Accommodation for Car 250 Kg Lt Veh (S/S) (RCC Framed Structure) along with APRON with permanent specification all as shown on drawings and as specified.
Construction of Covered Accommodation for 2.5 Ton Tata or Equivalent (S/S) (RCC Framed Structure) along with APRON with permanent specification all as shown on drawings and as specified.
Construction of Covered Accommodation for 5 Ton or Equivalent (S/S) (RCC Framed Structure) along with APRON with permanent specification all as shown on drawings and as specified.
Construction of Covered Accommodation for W/B 5 KL & Rough Terrain Fork Lift Truck (S/S) (RCC Framed Structure) along with APRON with permanent specification all as shown on drawings and as specified.
Construction of Covered Accommodation for Repair Bay and Army Bus (40 Seater) (S/S) (RCC Framed Structure) along with APRON with permanent specification all as shown on drawings and as specified.
Construction of Lubrication, Oil and Grease Store (S/S) (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.
Construction of MT Store (S/S) (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.
Construction of Sentry Post (S/S) (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.
Construction of Double Ramp with permanent specification all as shown on drawings and as specified.
Construction of Washing Platform with permanent specification all as shown on drawings and as specified.
Construction of Inspection Pit with permanent specification all as shown on drawings and as specified.
Construction of Incinerator with permanent specification all as shown on drawings and as specified.
Construction of Static Water Tank of capacity 15 KL with permanent specification all as shown on drawings and as specified.
SCHEDULE A PART II-A (Internal Water Supply) for details refer Sch A in pdf folder
SCHEDULE A PART II-B (Internal Water Supply)
S&F Brass Chromium Plated Wall Mixer '3 in 1' fancy type for mixing hot and cold water screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed.
S&F Brass Chromium Plated Central hole wash basin Mixer fancy type with or without lettered Hot or Cold with long screwed shanks and fly nut capstan head screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed.
S&F Brass Chromium Plated Angle Valve, fancy type screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed.
SCHEDULE A PART III-A (Internal Electrification) for details refer Sch A in pdf folder
SCHEDULE A PART III-B (Internal Electrification)
M & L for Point wiring with PVC insulated PVC unsheathed electric (FRLS-H grade) cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of chases in wall (MS/ Galvanised Iron boxes for hanging of ceiling fans and for light points along with conduit be fixed in ceiling while casting slab for fan point and for light points,in rigid pvc conduit will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including sunk in pressed steel terminal boxes of 1.6 mm thick and including bakelite sheet cover or hylam board of 2.8 mm thick including cutting holes for switches, sockets, regulators etc as per requirement including fixing with machine screw, washer etc for the following and -
(a) One light point controlled by one (one way switch )
(b) One fan point controlled by one (one way switch )
(d) One 3/5 pin socket outlet 5 Amp on the same board with other swithes.
(e) One 3/5 pin 5 Amps socket outlet on indepandant board.
BLANK
All as per item No 6 above but 2.5 sqmm FRLS-H grade cable PVC for 15 Amp 3/6 pin socket power point including 2.5 sqmm copper conductor green as colour for earth continuity all as specified and directed.
S&F Distribution board, made out of sheet metal enclosure (CRCA sheet) Vertical TPN, , 415 V, With 250 Amps rated copper bus bar, double door 8 way IP-54, IK-09 suitable for one MCCB as incomer and MCB TPN as outgoing mounted flush including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. Note MCCB / MCBs shall be measured and paid seperately.
S&F Distribution board, made out of sheet metal enclosure (CRCA sheet) Vertical TPN, , 415 V, With 250 Amps rated copper bus bar, double door 4 way IP-54, IK-09 suitable for one MCCB as incomer and MCB TPN as outgoing mounted flush including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. Note MCCB / MCBs shall be measured and paid seperately.
S&F Distribution board, made out of sheet metal enclosure (CRCA sheet) SPN 240Volt with 200 Amps rated copper bus bar, double door 8 way IP-43, IK-09 suitable for one MCB SPN as incomer and MCB SP as outgoing mounted flush, including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. Note MCBs shall be measured and paid seperately.
S&F Distribution board, made out of sheet metal enclosure (CRCA sheet) SPN 240Volt with 200 Amps rated copper bus bar, double door 4 way IP-43, IK-09 suitable for one MCB SPN as incomer and MCB SP as outgoing mounted flush, including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. Note MCBs shall be measured and paid seperately.
S & F MCB SP, 6 - 40 Amp, 10 KA, single pole, 'C' curve, 240 V, 50 Hz, complete all as specified and directed
S & F MCB SPN, 40-63 Amp, 10 KA, single pole, 'C' curve, 240 V, 50 Hz, complete all as specified and directed
M & L Sub main wiring with two runs of single core PVC insulated and unsheathed (FRLS-H) cable multistranded, copper conductor of size 2.5 sqmm, 1100V grade, drawn through and including 20mm dia or higher PVC non metallic medium duty conduit with in concealed wiring system by cutting chases in wall and one run of 2.5 sq mm single core insulated unsheathed FRLS-H cable multi stranded copper conductor, as earth continuity conductor including accessories required for PVC conduit complete all as specified and directed. Note:-. Two runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.)
M & L Sub main wiring with two runs of single core PVC insulated and unsheathed (FRLS-H) cable multistranded, copper conductor of size 4.0 sqmm, 1100V grade, drawn through and including 20mm dia or higher PVC non metallic medium duty conduit with in concealed wiring system by cutting chases in wall and one run of 4.0 sq mm single core insulated unsheathed FRLS-H cable multi stranded copper conductor, as earth continuity conductor including accessories required for PVC conduit complete all as specified and directed. Note:-. Two runs of cable, one run of earth wire and one run of PVC non metallic conduit shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.)
S& F LED light fitting 1x20 watt, 220 volt AC decorative box type with driver, holders including LED tube light connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and dfirected.
S& F LED light fitting high output diffuser 2 feet, 10 watt, 220 volt AC decorative type with driver, holders including LED lamp connecting up with three core flexible copper conductor of suitable size from ceiling rose complete all as specified and dfirected.
S&F ceiling fans 1200mm sweep 230 volt, Brushless direct current motor (BLDC) copper wound complete with blades, down rods, clamps, real insulator, nut, bolt, pin & washer, and other accessories, minimum air delivery 245 CFM, five star rated with squirrel cage induction motor complete all as specified and directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including LED bulb 10 watt complete all as specified and directed
Supply, installation, testing and commissioning of 25 Litre capacity Water Heater Storage type, five star rating, electric, suitable for single phase , 50 Hz, AC supply, steel with glass line coating inner tank, 2 KW heating element, twin thermostat for water temperature and safety thermostat ,ABS outer body including minimum 1 M of three core 2.5 sqmm twisted copper cable PVC sheathed, three pin plug top, PVC connection 450mm long of 6 kg/sqcm with two sets of chromium plated adopter at each end suitable for 15 mm bore GI pipe at cold water inlet and copper tubing connection with chromium plated adopters at ends at hot water outlet, with safety fusible plug conforming to IS complete all as specified and directed.
S & F LED Building security light fitting 35 watt made up with pressure die cast aluminium housing,, heat resistant toughened glass, with IP66 protection and impact resistance of Ik07 with 10 KV built in surge device, better optics for uniform distribution complete with electronic driver including connecting up with three core copper conductor cable 1.5 sqmm size copper wire from ceiling rose to connector of light fitting complete all as specified and directed.
S & F LED flood light fitting 80/70 Watt made up with pressure die cast aluminium housing,, heat resistant toughened glass, with IP66 protection and impact resistance of Ik07 with 10 KV built in surge device, better optics for uniform distribution complete with electronic driver including connecting up with three core copper conductor cable 1.5 sqmm size copper wire from ceiling rose to connector of light fitting complete all as specified and directed.
M & L for Point wiring with 1.35 Sqmm (nomonal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, (FRLS-H grade) in and including medium duty concealed PVC conduit 20mm dia or higher and conduit fittings with cutting chases and all accessories with suitable size of sunk type cast iron or pressede steel terminal box 1.2mm thick, duly painted for mounting of Modular switches, sockets, fan regulator etc with modular white cover plate as top cover, including continuous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly complete all as specified and directed for the following:- Note:- (a) Colour code shall be maintained as per IE rule (b) Modular Metal flush box frame cover plate and blank plate of suitable module as per site requirement aredeemed to be included in the quoted rates.
(a) One light point controlled by one (one way switch )
(b) One ceiling fan/exhaust fan point controlled by one, one way switch through Regulator
(c) One three pin 6 Amp socket on same board with other swithes.
(d) One three pin 6 Amp socket on independent board
(e) All as per item No 6.34(d) above but one 3 pin socket outlet 16 Amp independent with cable 2.5 sqmm size with earth conductor of size 2.5 sqmm.
SCHEDULE A PART IV (Site Clearance and Earthwork) for details refer pdf folder
SCHEDULE A PART VA (Road, Path and Culvert) for details refer pdf folder
SCHEDULE A PART VB (Road, Path and Culvert)
M&L for 150 mm thick (compacted thickness) WMM in two layers (each layer of 75 mm thick), with broken stone coarse aggregate (Granite,Basalt or Trap stone) of grading 2 (63 to 40 mm size for 1st layer) and (50 to 20 mm size for 2nd layer) grading 3, spread, rolled and consolidated to required gradient, camber, level and super elevation with 8 to 12 tonne power roller complete all as specified and directed.
M&L for applying thermoplastic reflective paint as in road marking of minimum 2.5mm thick single coat of 100/150 mm wide using HOT MARK thermoplastic paint (Hot application) white or golden yellow by indigenous modern properly road marking machine as directed incl all ingredients such as binder glass beads shall titanium dioxide calcium carbonate inter filler thermoplastic complete all as specified and as directed.
Supply & fixing of (89x101x16) mm (Cat eyes) made of non-breakable polycarbonate with electronically welded primatic Retro reflective in wet and dry condition body dust proof complete all as specified and directed.
Manufacturing,suppling and fixing retroreflective cautionary / warning sign boards ofequilateral triangle shape having each side of 900mm with support length of 3650 mm and made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-Lingual), symbols and borders etc as per IRC;67 : 2001 , pasted on substrate by an adhesive backing which shall be activated by appling heat pressure conforming to class-2 of ASTM-D 4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of MS angle iron of size 25 X 25 X 3 mm along with theft resistant measures, mounted and fixed with 2 Nos MS angles of size 35 X 35 X 5mm to a vertical post made up to MS tee section ISMT 50 X 50 X6 mm welded with base plate of size 100 X 100 X 5mm at the bottom end and including making holes in pipes, angles,flats, providing and fixing MS message plates of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand and manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours) backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc complete as per drawing , specification and direction of Engineer-in-charge.
SCHEDULE A PART VI A (Sewage Disposal) for details refer pdf folder
SCHEDULE A PART VI B (Sewage Disposal)
M & L for construction of septic tank 100 users with class 'B' brick masonry wall, PCC in foundation floor, RCC over slab including sludge chamber, CI vent pipe, CI cowl, inlet and out let pipe, RCC baffle wall and all necessary excavation and earth work complete all as specified , shown in TD drawing No 217 sheet No 1/7 to 7/7 as directed.
M & L for Soakage wells comprising of excavation, in any type of soil, foundation in PCC 1:3:6 type C2 , walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 M dia X 3 M effective depth all as specified and shown in drawing TD-309, sheet No 1/4 to 4/4
SCHEDULE A PART VII (Area Drainage) for details refer pdf folder
SCHEDULE A PART VIII (Fencing, Gate, Compound wall & Security wall) for details refer pdf folder
SCHEDULE A PART IX (Protective Work, Retaining wall) for details refer pdf folder
SCHEDULE A PART X A (External Water Supply) for details refer pdf folder
SCHEDULE A PART X B (External Water Supply)
M & L for cutting of existing road width 45cm and depth 60cm for laying of DI/GI pipe line and making good disturbed surface with PCC (1:3:6) type C2 complete all as specified.
SCHEDULE A PART XI A (EXTERNAL ELECTRIC SUPPLY) for details refer pdf folder
SCHEDULE A PART XI B (EXTERNAL ELECTRIC SUPPLY)
Supply, Install, connect, testing and commissioning of Step down Transformer pole mounted out door type copper wound three phase, 4 wire, primary side,11000 volts, and secondary side 415/433, three phase,three wire,Copper wound oil immersed, naturally cooled, with tapings on primary side to vary secondary voltage from (-) 7.5 % to (+) 7.5 % with steps at every 2.5 % variation with standard fittings / fixtures, with extended cable end box on LT side with neutral brought out complete with initial fill of transformer oil to appropriate level as suggested by the manufacturer, temperature gauge, breather, bucholz relay, cooling coil, suitable size cable glands on LT side, bushing on HT side all as specified confirming to IS : 1180:2014 Part-I,Level-2 of capacity 63 KVA including standard accessories, fitting as per manufactures specification the following : Make-SCHENIDER/ABB/CROMPTON GREAVES (a) Lifting lugs for transformer and tank (b) Earthing terminals and tatting diagram plate. (c) Air release device. (d) Oil filling inlet pipe with plug (e) Drain out gate valve. (f) Conservator with level indicator. (h) Initial oil filing with new oil to required level as per IS 335. (j) Delta/star type connection (k) ONAN cooling (l) DNY 11 vector group (m) Cable end box for suitable size cable on LT side. (n) Danger notice plate - 1 No (o) Thermometer with pocket
Supply and Installation of Tubular steel poles shall be swaged type & shall conform to IS 2713 (Parts 1 to 3) 1980. A through hole of 14 mm diameter shall be provided in each pole at a height of 300 mm above the planting depth for earthing arrangements. Finials and base plate shall be of cast iron and conform to the details given in fig. 3 and 4 of the Standard (IS-2713 Part 1*3 of 1980). Protection Against Corrosion The poles shall be coated with two coasts of black bituminous paint throughout internally and externally up to the planting depth. The remaining portion of the exterior with one coat of red oxide/emulsion paint & two coat of aluminium paint to GI bracket for street lights and two coats of zebra marking with enamel from ground level and upto 1 mtr hight including white washing the coping and cleaning the bushes surrounding the pole bottom upto 1 mtr width with CI base plate and finial taper plug, bolts, nuts & screws as specified type 410 SP 31,(9.0 Mtr long) all as directed. Note: (1) All excavation & earth work as involved shall be measured & paid seprately. (2) PCC foundation and Coping as involved shall be measured and paid seprately under respective items.
Supply and Fixing , Integral LED Street Light Luminaire comprising of high pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 60 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours including GI brackete made out of 25 mm GI pipe medium grade and MS clamps for fixing of light fitting (on 9.0 Mtr street light pole) with two No's nut bolt and washer for each clamp and connected with three core PVC insulated copper flexible cable with existing point all as specified and directed.
S&F Hot press moulded SMC junction box of thickness not less than 02 mm , factory fabricated front openable duly painted and of size 250 X 250 X 100 mm having bakelite connector suitable for 3 phase and neutral link including MCB SP 6 amps gunmetal cable gland for LT cable fixed to pole with MS 25X3 mm GI clamps made to shape with required nut bolt washers for street light fittings and post top lights etc.
Supply installation , commissioning and testing Main LT Panel outdoor type double door made out of CRCA sheet 3.15mm thick dust and vermin proof factory made cubical type duly painted alongwith insulators, vertically controlled complete of suitable size comprising of the following:-
In coming :-(a) MCCB 4 pole 415 V 100 Amps, 50 Hz 36 KA -01 Nos
Supply installation , commissioning and testing Sub-main LT Panel outdoor type double door made out of CRCA sheet 3.15mm thick dust and vermin proof factory made cubical type duly painted alongwith insulators, vertically controlled complete of suitable size comprising of the following:-
Incoming :- (a) MCCB 4 pole 415 V 63 Amps, 50 Hz 25 KA -01 Nos
Supply and Fix , 2.0MM thick CRCA Sheet Steel duly powder coated after 7tank Treatment, Outdoor Type, Weather proof Junction Box of size 400x400x200 approx. shall be Free angle 400MM height from ground level framed standing, front accessible, Double Door, Rear Openable, cable entry from bottom with following accessories all as specified and directed- (a) Incomer of 63A TP MCB 10kA -01 No (b) Phase Indication with Control MCB SP-01set (c) 16A TPN/4P 10kA -01 No (d) MCB Curve-'C' -02 No's with Power Terminals for each outgoing line. Note: (1) All excavation & earth work as involved shall be measured & paid seprately. (2) PCC foundation and Coping as involved shall be measured and paid seprately under respective items.
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600x600x 6 mm earth electrode buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plate using 32x6mm earth strip as earth lead moulded and rivetted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead protected in and including 40 mm dia GI ‘medium grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘medium grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as per electrical plate No.3 of SSR Part-II 2010 and testing on completion all as specified and directed.
S&F post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP-65 protection with impact and corrosion resistant including electric wire connection from light fitting to junction box ,complete with driver and lamp all as specified and directed please.
Supply and fix 11 KV outdoor type gang oprated air break switch suitable for horizontal or vertical mounting type fixed type complete with 9 insulators of rating 200 Amps,operated by handle ,located at approchable height from ground level,all specified and directed.
Supply and errect steel tubular pole swaged ISI Marked 11 Mtr long type 410 SP-55 complete with MS base plate 450 x 450 x 6mm pole cap finial taper plug, nuts, washers etc and including Anti climbing device and danger notice plate,painting two coats of aluminium paint over one coat of red oxide primer, 3 Nos band straps with yellow and black colour (300mm wide 2 Nos each) synthetic enameled paint including one coat on steel surface embeded in concrete all as specified and directed Note: (1) All excavation & earth work as involved shall be measured & paid seprately. (2) PCC foundation and Coping as involved shall be measured and paid seprately under respective items.
Supply and fix cable jointing kit for 11 KV garde cable for outdoortermination, heat shrinkble type, joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
M&L for laying dry clean sand filling in trenches / ducts for cushioning to under ground cable complete all as specified and directed. Note : Punned thickness shal be measured and paid.
M&L for laying well burnt old size, sub class 'B' bricks, in trenches, as protection of under ground cable complete all as specified and directed.
S&F Lightning arresters HT 11KV expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp with galvanised iron strip 32x6mm as earth lead connection upto earthing .
SCHEDULE A PART XII A (Cooling Appliances) for details refer pdf folder
SCHEDULE A PART XII B (Cooling Appliances)
Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stablized at 230 volt with accuracy +2.5 % and capacity upto 1 KVA,with suitable size and length of wire complete all as specified and directed. Make: Blue Star/V-Guard/Voltas
Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20Amp.
SCHEDULE A PART XIII (Fire Fighting)
S&F Fire Extinguisher ABC type 6 Kg capacity (With Lug Bucket, Hose, Screws, Nylon sleeves etc all as specified.
S&F Fire Extinguisher CO2 type 4.5 Kg capacity (With Lug Bucket, Hose, Screws, Nylon sleeves etc all as specified.
Supply and fixing Mild steel stand / hooks for hanging of fire buckets etc including two coats of synthetic enamel painting over one coat of red oxide primer complete all as specified and directed.
Supply only fire bucket
SCHEDULE A PART XIV (Dismantling/ Demolition) for details refer pdf folder
Note :- Tenderes may note that amount of schedule of credit Rs 92765.00 will be deducted from the total amount at the time of acceptance of the contract.
A.S. CONSTRUCTION CO.
BD AGARWAL BUILDTECH INDIA PRIVATE LIMITED
Sudhir Sharma Associates
BHARATSHAH CONSTRUCTION CO
JASPAL SINGH & CONST
CHITTER MAL & CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .