| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC NABAJIBAN 1 NABAJIBAN COLONY BISHARPARA KOLKA 700158 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700158 | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.4 L+₹14,340 (2.74%)Rejected-Finance P O SASINDA VILL KASHIYA P S BELDA WEST MEDINIPUR PIN 721445 | BELDA | PASCHIM MEDINIPUR | WEST BENGAL | 721445 | L2 | Rejected-Finance L2 | |
| 3 | L3₹5.5 L+₹25,441 (4.85%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹15,253
Closing Date
23 May 2025, 11:00 amClosed
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
Maintenance of E.I work-------Supply and installation of drainage water system of different type AC machines and replacement of different type light fittings and allied E.I. works at Purta Bhawan, Salt Lake, Kolkata-91
2025_WBPWD_843202_1
WBPWD/EE/BED/e-NIQ-15/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
Purta Bhawan
Please refer Tender documents.
5 documents required · 5 mandatory
₹15,253
30 May 2025
16 May 2025
26 May 2025
16 May 2025
23 May 2025
16 May 2025
Amount
Dismantling of existing outdoor units & Angle Iron Frame for 1.5/2.0 ton A.C machines with own tool & tackles as per direction of EIC.
Supply & Fixing of MS Angle Iron Frame with 6 nos Heavy Duty Anchor Bolt Fasteners as required for holding 1.5/2.0 ton AC outdoor unit as per direction of EIC.
Refixing of existing 1.5/2.0 ton A.C machines outdoor units at newly installed Angle Iron Frame with own tool & tackles as per direction of EIC.
SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping Split AC system, complete with fittings and including accessories, insulated with XLPE class -O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specification etc. as required. 1/4" (6.4 mm) dia (Soft drawn) Cu. Pipes (As per standard 85864 or ANSIB 16.22) incl. 19 mm thick insulation.
5/ 8" (15.88 mm.) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19 mm thick insulation.
Supply & Laying PVC Drain Pipe 25mm dia with 6mm thick nitrile rubber insulation (Make-supreme / Ori-Plast)
Charges for dismantling of damaged copper pipeline after complition of civil work as per direction of EIC.
Charges for dressing and proper arrangement of copper pipe after complition of AC machine of different floor as per direction of EIC.
Charges for insulation of copper pipe with elastometric nitrile rubber tubular sleeves section and wripping the same as per direction of EIC.
S & F Timer Control unit for 1 Ph AC machines with 12-way SPN DB Box (Mk.- L & T/ Crabtree/ kgrand/ Siemens/ ABB): i) 12 way SPN DB or Timer DB- 1 no. ii) 40A DP MCB Isolator-1 no. iii) Digital 24 hrs.Time switch- 1 no. iv) 324 2-pole power contactor-1 no. v) Centre off 2-way toggle switch-1 no. vi) 32A Barrier type Terminal -1 no. vii) LED indicating lamp-1 no. viii) 2x4+1x2.5 Sq.mm Cu wire(Gloster/ KEI/ RR Kabel)
S & F 1.1 KV grade, PVC insulated & unsheathed 3 Core 2.5 Sqmm Copper flexible Cable for Socket to Indoor & Indoor to outdoor connection as per direction of EIC.
Supplying, fifting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to lS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbow, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fiftings as required, jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (i) CPVC Pipes Class -I, SDR-11 (Dia) 40 mm.
Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge. (This item should be executed only after prior approval of the Engineer- incharge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. lf necessary further after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly.' (a) 3.9 meter height
(b) Extra for additional 3.6 height or part thereof
S & Charging Refrigerent R32 Gas as per direction of EIC.
S & Charging Refrigerent R410A Gas as per direction of EIC.
S & F of 15W, Square / Round type, LED, WW, Surface Mounted downlight (Philips / Crompton / Orient / Havells / Equivalent) as per direction of EIC.
S & Replacing of 12W, Square / Round type, LED, WW, Surface Mounted downlight (Philips /Crompton /Orient /Havells /Equivalent) as per direction of EIC.
Supply and fixing 6-32A C curve MCB as per direction of EIC. (Make- Legrand/Seimens/ABB)
Supplying and fixing 240/415 V 63A FP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection after replacing damaged one as per direction of EIC. (Make: Legrand)
Supplying and fixing 240/415 V 125A FP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection after replacing damaged one as per direction of EIC. (Make: Legrand)
S & F of 240V, 25A / 32A DP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection after replacing of Isolator as per direction of EIC.
Supply and fixing of 35/36 watt system wattage 6500 K colour Temperature, cool day light colour, recessed mounted IP 20 LED 2ft X 2ft luminaries having > 3050 lm system output. Luminary shall be made up of CRCA epoxy polyester powder coated housing. Luminaries shall have optical grade High Efficiency Translucent Optical component for very high efficiency with minimum glare.Driver output voltage shall be less than SELV limits for safe DC operation and maintenance. The Driver should be fully designed and manufacture in India. The fittings should be fixed in false ceiling by hanging with chain / spring and fastner and as required for proper fixing with the actual ceiling and complete with all accessories having following Model/Cat No.- Philips RC380B LED42S- 6500 G6 L60W60 PSU OD S1/ Wipro CRCO1ORO3OHP57G3 /As per choice of EIC
Supply and fixing of 4 Ft. Single LED Fitting with 1 no 20 Watt MAS LED tubelight (CCT- 6500 K, CRI- ≥ 70%, Minimum Lumen Out of Luminaries:- 100 lm/watt) for indoor application,complete with all accessories having following Model / Cat No. [Make- Crompton-IGP161LT8-16 1xT8 & -LGT8-20-865-2 /Philips-TMC 502 1X T-LED 22W & Mas LEDTube18W, 2100lm 865 T8 /Wipro/As per choice of EIC]
Less Cost dismantle materials :
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
BARSHA ENTERPRISE (BID ID -6427096)
SUPARNA REFRIZARATION (BID ID -6438729)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .