Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | ₹32.1 L Quoted ₹32.8 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹35.3 L+₹2.5 L (7.50%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | ₹35.3 L+₹2.5 L (7.50%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹40.6 L+₹7.8 L (23.8%)Rejected-Finance | ₹40.6 L+₹7.8 L (23.8%) | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹64,000
Closing Date
15 Feb 2022, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
SPECIAL REPAIR TO BUILDING NO. P-13 AT NAVAL PARK, INS DWARKA OKHA UNDER GE NAVY PORBANDAR
2021_MES_488273_2
8788/Okha/E8
Open Tender
Civil Works
Item Rate
180 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹64,000
Yes
1 Mar 2022
25 Jan 2022
17 Feb 2022
25 Jan 2022
15 Feb 2022
2 Feb 2022
26 Jan 2022 - 1 Feb 2022
Amount
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Taking down Shutters of any description exc 1 Sq. m and n exc 2 sq. m each and refixing in the same opening including adjustment if required complete all as specified and as directed.
Taking down chowkat or frames exc 1.5 Sqm and n.exc 4 Sqm each with shutter (without taking off Shutter) complete all as specified and as directed.
2nd class hardwood plain, solid straight chowkhats and frames, wrought, framed rebated on the solid,rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
Factory made 40mm thick, 2nd class hard wood , plain framed, panelled shutters, (two panel) with lock rail and, panels shall be of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
Factory made 35 mm thick,2nd class hard wood, glazed and skeleton shutters open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etc for doors, size of members as specified in clause 8.24 (a) of MES Schedule Part-I Section-8, and fitted to chowkats, kiln seasoned and chemically pressure treated complete all as specified and as directed.
300mm long (Length of Bolt in mm) Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed in repairs complete all as specified.
150mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
150mm Extruded aluminium alloy handles, fabricated type, anodised and fixed in repairs complete all as specified.
100mm Butt hinges(Size of hinges in mm), medium weight, cold rolled, stainless steel, and fixed in repairs complete all as specified.
250mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed in repairs complete all as specified.
200mm Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed in wooden shutter fixed in repair complete all as specified.
150mm (Size of Handle in mm) Extruded brass handles, fabricated type, anodised and fixed in repairs complete all as specified.
100mm Butt hinges, extruded brass, with mild steel hinge pin, bright polished, type B-11 and fixed in repair complete all as specified.
Brass double body door stopper fixed in repair in door complete all as specified
Aluminium (Extruded Section Body) Door closer hydraulically regulated,designation No. 3,universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed in repair / replacement complete all as specified.
Preparation of new wood and wood based surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of wooden primer complete all specified and directed.
Plain, Aluminium sheeting 0.71mm thick, Alloy 31000 H4 fixed in building expansion joint and seal fixed in repair / replacement complete all specified and directed.
Taking down chowkat or frames n.exc 2 Sqm each with shutter (without taking off Shutter) complete all as specified and as directed.
Powder coated aluminium anodised frame and shutter for doors, windows and partitions with one or more rebates including necessary joining cleats, glazing clips, rubber neoprene packing, handle, stoppage, locking arrangements etc complete with powder coating of approved colour minimum thickness 50 micron complete all as specified and directed.
Aluminium Alloy wire cloth. 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples fixed in repairs complete all as specified.
4.8 mm thick Sheet glass,ordinary quality pin headed type and glazing with Aluminium snap beading with rubber Neoprene packing in square exc 0.5 sq. m in each pane complete all as specified and as directed.
5.5 mm thick Sheet glass,ordinary quality pin headed type and glazing with Aluminium snap beading with rubber Neoprene packing in square exc 0.5 sq. m in each pane complete all as specified and as directed.
Solar control film 25 micron reflective type pasted to glass panes as per instructions of manufacturers exc 1.5 sqm complete all as specified and as directed.
Taking down aluminium anodised grill of any size and any type complete all as specified and as directed.
Aluminium anodized Deco grills 7.50 mm of Design No DG 104 with suitable size F & H sections as required to aluminium/wooden windows complete all as specified and directed.
18-19mm thick pre laminated particle board, flat pressed single layer type or three layer type with BWR type adhesive, medium density interior grade having one side decorative lamination and other side balancing white lamination as in cup board shutter , shelves including 6 mm thick teak wood leaping on three sides and 20mm thick on hanging side & French polishing to edging, fixed in repair, complete all as specified and as directed.
30mm (Width of flaps (when open) in mm) Continuous (piano) hinges,mild steel, bright finish or electro galvanised complete all as specified and directed.
100mm dia, cupboard mild steel pressed handles, oval type, stove enamelled black fixed with nut, screw and washer of mild steel complete all as specified and directed.
Standard quality magnetic catcher for cupboard shutters complete all as specified and directed.
Dismantling of old dilapilated and unserviceabe Stainless steel railing of any size and pattern complete all as specified and directed.
Providing and fixing stainless steel (Grade-304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc, of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasterns complete all as specified and directed.
25mm dia Stainless Steel curtain rod fixed in repair / replacement complete all as specified and directed.
Statinless steel bracket for curtain rod of 25mm dia for fixing in walls fixed in repair / replacement complete all as specified and directed.
Marble tiles (Baroda/ Udaipur green) 20mm thick machine cut as in flooring, including 20mm thick screed bed in CM 1:4, jointed and pointed with grey cement slurry and pointing with white cement (1:3) using marble dust with admixture of pigment to match with shade cutting and polishing complete all as specified and directed.
Marble tiles (Baroda/ Udaipur green) 20mm thick machine cut as in dado/skirting including 20mm thick screed bed in CM 1:4, jointed and pointed with grey cement slurry and pointing with white cement (1:3) using marble dust with admixture of pigment to match with shade cutting and polishing complete all as specified and directed.
M&L for Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in 20mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of following types complete all as specified and directed.
20 to 25 mm thick Kota stone slab of Ist quality, Machine cut, table rubbed and polished as in flooring laid over and including 20mm thick screed bed in cement mortar (1:4), set & jointed in grey cement slurry mixed with pigment to match shade of slab, including rubbing grinding and mirror polishing complete all as specified and directed.
20 to 25 mm thick kota stone slab as in skirting, riser of steps and pillars over and including 15mm thick rendering in cement mortar (1:4) including rubbing grinding and mirror polishing complete all as specified and directed.
Dismantling stone slabs, tiles in floor, hearth or wall tiling including cement mortar bedding (but not backing), removing, rubbish off the premises complete all as specified and directed.
Vitrified Ceramic tiles 10 mm thick, Light shade coloured (square/ rectangular) (double charged) area of each tiles not exceeding 0.36 sqm, as in floors set and jointed in neat cement slurry and pointed in coloured epoxy grout to match , over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 complete all as specified and as directed.
Taking down Demolition of old textile covering from roof (old WPT) complete all as specified and as directed.
PCC 1:2:4, type B-0 (using 12.5mm graded stone aggregate) as in concrete padding, 40mm average thickness laid to required slope, including finishing the concrete surfaces fair and even without using extra cement, including mixing WPC @ 3% of cement (WPC shall be Paid separately), complete all as specified and as directed.
Water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment / specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.6 Kgs per Sqm, reinforced with non woven polyester fabric or weight not less 150 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm 9 minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing, complete all as specified and as directed. Note:- (i) Laying of APP based membrane shall be done by torch on method and as per manufacturer's instructions. (ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and all overlaps and joints are properly sealed as per manufacturer's instructions. (iii) Applying two coats of Bituminous aluminium paint on top of APP membrane cover including testing on completion complete all as specified and directed.
Anti-skid Endura Cool roof SRI (Solar reflective Index) ceramic tiles (of approved color), 300x300x10mm thick, square / rectangular laid over plastered surface of roof in 15mm thick screed bed in CM 1:4, joints grouted with tile grout complete all as specified and as directed.
Glazed ceramic tiles, coloured (light colour as approved) of size 450 x 300 x 8 mm on vertical surfaces such as in skirting/dado etc set and jointed in cement slurry over 15mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed.
M&L Non skid Ceramic coloured tiles of 8mm thick (area of each tile exceeding 0.06 Sqm but n.exc. 0.11 Sqm) as in floor set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tiles over and including 15mm thick bedding layer of cement mortar (1:6) complete all as specified and directed.
Machine grinding and polishing (Mirror / Diamond polishing) of existing kota stone flooring complete all as specified and directed by Engr-in-charge complete all as specified and directed.
Chequered cement concrete coloured tiles ( grey cement mixed with pigment) 20cmx20cmx25mm thick set over & including 20 mm thick bedding layer in cement mortar (1:4) with neat cement and pointed in grey cement mixed with pigment to match the shade of tiles, complete all as specified and as directed.
Dismantling of wall and ceiling board (Fibre, Pulp, insulation etc.) or insulation board /slab/ blankets, any thickness including cover fillets complete as specified and directed.
Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx. 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, including hangers and hanging arrangements, including providing and fixing 12 mm thick Seamless calcium silicate ceiling board made out of1800 x 1200mm size board, comprising of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25mm long self drilling and tapping screws having Phillips head with under head cutter at minimum spacing of 200mm centre to centre, including finishing the joint of face board with specially formulated jointing compound and 48mm wide fibre tape to provide seamless finish and multi layer design, complete all as specified and as directed.
Demolition of unreinforced cement concrete in ground floor and paving in any position below or above ground level complete all as specified and as directed.
PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete or as in sub base complete all as specified and directed.
Demolition of brickwork or stone/boulders/block masonry, built in cement mortar including all quoins, arches, pillars, ashlar facing, dressed stonework, precast concrete articles and precast concrete block walling complete all as specified and directed.
Stone masonry walling or squred walling in cm 1:6, brought upto courses using dressed same size Porbandar stone of superior quality complete all as specified and directed.
Taking down cement plaster of any description incl raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
Rendering 10 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:6 finished even and smooth without using extra cement including mixing Integral Water proofing treatment (where ever required as directed by Engineer in charge) complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately.
Rendering 15 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:4 finished even and smooth without using extra cement including mixing Integral Water proofing treatment (where ever required as directed by Engineer in charge) complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately)
Supply only integral water proofing compound.
Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of wall care putty complete all specified and directed.
Preparation of newly plastered surfaces of walls, soffits & facias roof and applying two coats of weather proof Acrylic based exterior emulsion paint over a coat of primer complete all as specified and directed.
Preparation of old plastered or unplastered surfaces of walls, soffits & facias roof and applying one coat of anti fungal weather proof Acrylic based paint complete all as specified and directed.
Complete removal of existing treatment preparation of surfaces of walls and applying one coat of wall care putty and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and directed.
Preparation of old plastered or unplastered surfaces of walls and applying two coats of oli emulsion distemper complete all as specified and directed.
Preparation of old plastered or unplastered surfaces of ceilings and applying one coat of oli bound distemper complete all as specified and directed.
Preparation of old plastered or unplastered surfaces of ceilings and applying two coats of white wash complete all as specified and directed.
Preparation of new wood and wood based surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of wooden primer complete all specified and directed.
Taking down rainwater/waste pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks complete all as specified and directed.
PVC (SWR) pipes, 110mm bore, single socketed, 4.00 Kgf per Sqcm pressure, in any length with rubber ring joints complete all as specified and as directed.
110mm bore PVC (SWR) bends, single / double 'Y' or 'T', with access doors, any radius including fixing clips complete all as specified and as directed.
110mm bore PVC (SWR) couplers including fixing clips complete all as specified and as directed.
110mm bore PVC (SWR) vent cowel including fixing clips complete all as specified and as directed.
Single piece europeon type WC starwhite and seat cover of soft closing type dual flush fitting with P or S trap including fixing accesorise for fix in floor fixed in repair / replacement complete all as specified and directed.
Wall hung WHB with full pedestal min size 600x 450mm including fixing accesorise, waste coupling, waste pipe & PVC connection pipe) fixed in repair / replacement complete all as specified and directed.
Vitreous china wash Hand basin size 550 x 400 mm including waste pipe and waste coupling chromium plated, brackets and cutting for and pinning in ends of brackets or errecting stand but excluding taps, chain and plug fixed in repair / replacement complete all as specified and directed.
Fancy type pillar taps swan neck long shank chromium plated cast copper alloy 15mm bore with crutch screwed down fixed in repair / replacement complete all as specified and directed.
Single lever brass CP Hi flow diverter of hot -cold mix type with concealed part (internal part) with provision of connection to overhead shower fixed in repair / replacement complete all as specified and directed.
Single lever quarter turn brass CP long body bib cock 15mm bore for fixing in 15/20mm dia concealed pipe line fixed in repair / replacement complete all as specified and directed.
Fancy type two way bib cock, chromium plated cast copper alloy 15mm bore with crutch screwed down fixed in repair / replacement complete all as specified and directed.
Health faucet with flexible pipe (ABS body) with 01 meter long tube & wall hook Make Jaquar Model No ALD-chr-583 or equivalent model of make specified, fixed in repairs, complete all as specified and as directed.
Single lever quarter turn brass CP angle cock 15mm bore for fixing in 15/20mm dia in concealed pipe line fixed in repair / replacement complete all as specified and directed.
Brass CP overhead shower in square of size 200mm including metal shower arm of required length and size for fixing in 15/20mm dia pipe fixed in repair / replacement complete all as specified and directed.
600mm long brass CP towel rack with lower hangers and hook complete fixing accesorises fixed in repair / replacement complete all as specified and directed.
Fancy type stainless steel soap dish,fixed to plugs with chromium plated brass screw fixed in repair / replacement complete all as specified and directed.
Corner glass self (set of 2) with chrome finish bracket of min size 290x290mm for fixing in wall fixed in repair / replacement complete all as specified and directed.
Chrome finish Anti cockroach floor trap complete set in square of size 150x150mm for fixing in floor fixed in repair / replacement complete all as specified and directed.
Toilet paper holder, brass chromium plated fixed to walls with brass screws fixed in repair / replacement complete all as specified and directed.
Fancy type Chromium plated towel rail, 20mm dia, D type, 60cm long between flanges fixed in repair / replacement complete all as specified and directed.
Taking up or down CPVC water tubing of 20/ 25mm bore pipe and connections complete all as specified and as directed by Engineer-In-Charge.
20mm (outer dia) CPVC pipes, UV stabilised, SDR 11 pressure bearing capacity 28.12 kg/sq.cm @ 23 C ,leak proof, tough, rigid and suitable, fixed to walls with clamps / ceiling / concealed in wall including cutting chases and making good, or laid in trenches / jointed with sealant solvent leak proof including all fittings elbow, Tee, Socket, Reducer, Bushing, Step over head bends, End cap, End pugs, union, tank nipple and special fittings (brass insert threaded) like male, female treads, adapters, brass tee & reducers, male brass threaded adaptor, female brass threaded adaptor, flange including making Suitable size of brass threaded terminal to match the CP/PTMT plumbing fittings and interconnections as required for internal and external water supply applications, reconnecting existing fittings, fixed in repair complete all as specified directed.
25mm (outer dia) CPVC pipes, UV stabilised, SDR 11 pressure bearing capacity 28.12 kg/sq.cm @ 23 C ,leak proof, tough, rigid and suitable, fixed to walls with clamps / ceiling / concealed in wall including cutting chases and making good, or laid in trenches / jointed with sealant solvent leak proof including all fittings elbow, Tee, Socket, Reducer, Bushing, Step over head bends, End cap, End pugs, union, tank nipple and special fittings (brass insert threaded) like male, female treads, adapters, brass tee & reducers, male brass threaded adaptor, female brass threaded adaptor, flange including making Suitable size of brass threaded terminal to match the CP/PTMT plumbing fittings and interconnections as required for internal and external water supply applications, reconnecting existing fittings, fixed in repair complete all as specified directed.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges, cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but not exc 20 cm girth complete all as specified and directed.
Stainless steel kitchen sink made of SS 304 grade steel of single bowl size 1140x450x400mm with suitable size of SS stand and vertical projection of minimum 150mm for stoppage of water splashes on wall portion including waste coupling , waste pipe, rubber/ pvc stand shoes and accesorise for fixing all as specified and directed fixed in repair / replacement complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Rolled mild steel Framed work (rolled mild steel Fe - 410-W (Gde-E-250) quality "A") as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
Preparation of new steel surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all specified and directed.
Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar (articles exc 5kg each) fixed in repair / replacement complete all as specified and directed.
Demolition and breaking up drain pipes 150mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
Reinforced concrete pipes 150mm bore of pipe, class NP2, laid in trenches and jointed complete with collars complete all as specified and directed.
PCC 1:3:6 type C-2 as in bed to drain pipes of 150mm bore including packing under and haunching against the sides of pipe after they are laid and tested, including filling complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light/fan, buzzer, socket or power point etc) complete including all fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc including making good the disturbed surface to match with the existing all as specified and directed by Engineer-in-charge.
Taking down sub main wiring and making good disturbed surfaces of wall / floor complete all as specified and as directed.
Point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for the following :- One light or fan point controlled by one one way switch
All as per above item No. 104 but One 5 Amps 3/5 pin socket outlet on same board with other switches.
All as per above item No. 104 but One 5 Amps 3/5 pin socket outlet on independent board.
All as per above item No. 104 but One bell/ buzzer point controlled by one push button independent.
Point wiring with 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for Description a for independent switch socket outlet 6 pin 5/15 Amps complete all as Specified and directed by Engr-in-Charge.
Sub main wiring concealed with two runs of single core 6 Sqmm (Nominal area) cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, ISI marked with copper conductor drawing into rigid non-metallic PVC concealed conduit complete with including one run of 6sqmm (nominal area) single core PVC insulated multistrand unsheathed FRLS copper conductor as earth wire and duly connected to all common earth point, complete all as Specified and directed by Engr-in-Charge. (Conduet shall be measured and paid separately).
Sub main wiring concealed with two runs of single core 4 Sqmm (Nominal area) cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, ISI marked with copper conductor drawing into rigid non-metallic PVC concealed conduit complete with including one run of 4 sqmm (nominal area) single core PVC insulated multistrand unsheathed FRLS copper conductor as earth wire and duly connected to all common earth point, complete all as Specified and directed by Engr-in-Charge. (Conduet shall be measured and paid separately).
Ceiling rose surface bakelite 65x50mm 3 terminal complete all as specified and directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with 10 Watt LED Lamp fixed in repair / replacement complete all as specified and directed.
DBOXx MCB Protected Socket With sheet steel Enclosure single pole 20 Amp with 3 pin plug top for AC connection from Socket point to stabilizer complete all as specified and as directed. Make :- Havells Cat No- 20 A MCB DBOXX COMBO or equivalent cat part of makes specified here-in-before.
SKYLUX LED recess mounting 18 W false ceiling luminaire to enhance the delight of occupants with comfortable experience through its classic design & glare free soft illumination complete all as specified and directed by Engineer - in - Charge. Make:Bajaj Cat Part No. 111910/ BZRSQL 18W WH
Taking down existing ceiling fan / exhaust fan any size, any make, refixing the same after replacing the rubber bushes, split pin, servicing, greasing and painting with two coats of synthetic enamel paint complete all as specified and directed.
Exhaust fan 300mm sweep AC, 240 volts fixed as per manufacturer instruction, connecting with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable complete all as specified & directed by Engr in charge.
Wall mounted 10W LED natural white Engineering plastic battern,with white acrylic cover duly prewired and connecting fixed in repair / replacement complete all as specified and directed. Make:-Bajaj Cat no:- 112408/BCLSP 10 NW or equivalent cat part of makes specified here-in-before.
LED luminaire, 20W integral, sleek extruded polycarbonate LED channel, with inbuilt electronic driver / control gear, bi-pin holders, connector blocks, etc. with all connected accessories internally pre-wired, including 20W LED bulb connecting lead of 3 core 1.5sqmm flexible copper wire 1.5sqmm from ceiling rose to fitting fixed in repair / replacement complete all as specified and directed. Make: Bajaj Cat Part No. BCLSB 20WH or equivalent cat part of makes specified here-in-before.
Building street light fitting Endura pearl 20W LED lamp new genaration energy saving & environmental friendly long life made up of pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP65 protection and impect resistance of IK07,with suitable of GI pipe (light grade) bracket and clamps,nut bolts are fixed on wall/post fixed in repair / replacement complete all as specified and directed. Make Havells cat no ENDURAPEARLSL20WLED757SASYTOPC or equivalent cat part of makes specified here-in-before.
Modular white cover plate suitable for 1 modules with frame fixed in repair / replacement complete all as specified and directed.
Modular white cover plate suitable for 3 modules with frame fixed in repair / replacement complete all as specified and directed.
Modular white cover plate suitable for 6 modules with frame fixed in repair / replacement complete all as specified and directed.
Modular white cover plate suitable for 8 modules with frame fixed in repair / replacement complete all as specified and directed.
Modular white cover plate suitable for 12 modules combined plate-Coral with frame fixed in repair / replacement complete all as specified and directed.
Modular switch 1 way 6 Amps, 1 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Modular switch 1 way 16 Amps, 1 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Modular socket 6A, 2/3 pin combined, 2 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Modular socket 16A, 2/3 pin combined, 2 modules 230 volts fixed in repair / replacement complete all as specified and directed.
Bell push 6A, 1 module 230 volts fixed in repair / replacement complete all as specified and directed.
Call bell multi musical type fixed in repair / replacement complete all as specified and directed.
Ceiling fan regulator five step 02 module, hum free, AC, 230 volts, 100 watts, fixed in repair / replacement complete all as specified & directed.
MCB DB Single pole and neutral 4 way double door fixed in repair / replacement complete all as specified and directed.
MCB DB Single pole and neutral 8 way double door fixed in repair / replacement complete all as specified and directed.
MCB DB Single pole and neutral 12 way double door fixed in repair / replacement complete all as specified and directed.
TPN and vertical loadline 4 way double door suitable for G frame MCCB DBs are fitted with Bus Bars, Neutral Links, Blanking Plates with incomiing MCCB 100 Amp -01 N, (4 Pole, 35 KA breaking capacity Fixed Thermal & Fixed Magnetic setting Ics = 50% of Icu) and Outgoing MCB Tpn 63 Amp -3 Nos connected with duly wire fitting on wall and smooth finishing after fixed in repair / replacement complete all as specified and directed. Make :- Havells Cat No :- DHDLVDRWGOFO04 or equivalent cat part of makes specified here-in-before.
MCB SP 240 Volts AC 6 - 32 Amps of breaking capacity 10 KA C curve, fixed in repair / replacement complete all as specified and directed.
MCB SPN 240 Volts AC 40 Amps of breaking capacity 10 KA C curve, fixed in repair / replacement complete all as specified and directed.
RCCB 63 Amp FP 100 mA,Four pole,240V,50Hz,IP-20,protection against earth fault/leakge current conforming IS-12640-12000,IEC 61008-1 fixed in repair / replacement complete all as specified and directed. Make:- Anchor Cat No- 98207 or its equivalent of L&T / Havells / Legrand
Wall mounted fan white in colour 400mm sweep,3 in number complete all as specified and as directed. Make - Havells (platina 400mm) / Bajai / CG
Material and labour for taking out window type Air conditioner 1.0 Ton capacity of any make from its original location, removing the dust from body with blower, cleaning the condenser and cooling coil using water and caustic soda solution and checking all connections including functioning of metal clad socket/ DP switch function of relay capacitors overload protector thermostat fan motor blade fan blower drum oiling / greasing of fan motor, refixing to its original location including testing making it fully functional complete all as specified & directed by Engineer-in-Charge.
Material & labour for servicing the split AC's of various capacities i.e. 1.50/2.00 Tonne by removing dust with blower, cleaning the outer & inner unit using water and solution, checking all connections and spares making the split AC fully functional complete all as specified & directed by Engineer-in-Charge. Note for item No. 140 & 141: The cost of Minor consumeables & refrigerentt Gas for top up is deemed to be included in the quoted rate.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level Galvanised earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron GI protection pipe 15mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover including testing on completion complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, pipe line, cable , etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm deep as in soil complete as specified.
Removing excavated material (soil/ rock) to distance not exc 50 m and depositing where directed at a level not exc 1.5m above the starting point,complete all as specified and directed.
Fine dry river sand cushion in trenches for cable protection with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. NOTE: - Only compacted thickness will be measured and paid.
Precast concrete cable cover unreinforced, ISI marked class LV types 2 flat size 250mm x 150mm x 40mm having minimum average breaking load 200KG, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified.
GI tubing light grade ISI marked for cable protection at road crossing/floor/wall/ on poles or at any indicated situation etc duly sealed at both end after drawing cable including necessary clamps, saddles all as directed and specified for 40 mm bore dia, complete all as specified and directed.
Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (Heavy duly) with stranded aluminium conductor cross sectional area 35 sqmm 3.5 core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe and protection clamps shall be measured and paid for separately.
Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (Heavy duly) with stranded aluminium conductor cross sectional area 50 sqmm 3.5 core suitable for working on 1100 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe and protection clamps shall be measured and paid for separately.
25mm dia bore galvanised steel water tubing medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends, elbow, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions) and fixing complete with clips, wall hooks, wooden plugs or laying in trenches also cutting, screwing and waste and for making forged bends on piping as required at site including taking down the existing pipe line with fitting complete all as specified and as directed.
Gun-metal, ball valve, disc type with iron wheel, screwed both ends for iron pipe, ISI marked of size 25mm bore ,complete all as specified and as directed.
Gun-metal, ball valve, disc type with iron wheel, screwed both ends for iron pipe, ISI marked of size 50mm bore ,complete all as specified and as directed.
JAY BHARAT METAL SUPPLIERS
BABUBHAI BHIMABHAI PANDAVADRA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .