| Sl No | Description | Qty | Unit | M/S HIRA CONSTRUCTION L1 | M/S RAJ KAMAL GARG L2 | ROYAL INSTRUMENT INDIA PVT LTD L3 |
|---|---|---|---|---|---|---|
| 1.00 | Solar Module Mounting (Galvanised Steel) surface structure (for 10 kW) having Hot deep galvanised of Zinc thickness 80micron and as per IS4759 with C Channel $ anti theft with nut bolt of grade SS304,which should also withstand high wind velocity upto 150km/hr or as per MNRE. | 5 | Per set | 47,500 ₹2,37,500 Lowest | 52,250 ₹2,61,250 | 52,500 ₹2,62,500 |
| 2.00 | 10kWp SPV module of 330wP or higher rating, which must have Specification as per IS 14286/IEC 61215 .The module must have to quilify IS/IEC 61730 part I $ II (or having mechanical load test of 5400Pa) for safety purpose.Module to Module wattage mismatch in SPV Array shall be +/-3% and to qualify IEC TS 62804-:2015 for the detection of potential induced degradation and warranted for output wattage not less than 90% in 10yrs and 80% at the end of 25yrs as per MNRE. | 5 | Per set | 1,90,000 ₹9,50,000 Lowest | 2,09,000 ₹10,45,000 | 2,10,000 ₹10,50,000 |
| 3.00 | USPC controller with SPV module/VFD integrated with GPRS,having MPPT ,Protection IP 65 or above as per MNRE to run 10HP AC induction motor pump set . | 5 | Nos. | 38,000 ₹1,90,000 Lowest | 41,800 ₹2,09,000 | 42,000 ₹2,10,000 |
| 4.00 | Solar cable 4 mm2 used as per IS 694 or as per MNRE. | 100 | M | 50.35 ₹5,035 Lowest | 55.38 ₹5,538.5 | 55.65 ₹5,565 |
| 5.00 | copper cable 95 mm2 used as per IS 694 or as per MNRE. | 100 | M | 1,068.75 ₹1,06,875 Lowest | 1,175.62 ₹1,17,562.5 | 1,181.25 ₹1,18,125 |
| 6.00 | Copper cable 16 mm2 for earthing as per IS 694 or as per MNRE. | 50 | M | 201.4 ₹10,070 Lowest | 221.54 ₹11,077 | 222.6 ₹11,130 |
| 7.00 | Supplying and commissioning of earthing and lighting arrestor and surge protction as per IS 3043,IEC62305-3 and IEC 63227 for 10 HP AC induction motor pump set. | 1 | Nos. | 2,375 ₹2,375 Lowest | 2,612.5 ₹2,612.5 | 2,625 ₹2,625 |
| 8.00 | 10 H.P. A.C induction motor Solar pump set of having performance with respect to Total Head,Maximum Current,Capacity, Voltage Range etc as per MNRE guidelines. | 5 | Nos. | 74,100 ₹3,70,500 Lowest | 81,510 ₹4,07,550 | 81,900 ₹4,09,500 |
| 9.00 | Miscllaneous Accessories for Installation of 10H.P. A.C induction motor Solar Pump(L.S) | 5 | Per set | 3,325 ₹16,625 Lowest | 3,657.5 ₹18,287.5 | 3,675 ₹18,375 |
| 10.00 | Supplying,installation and commissioning Charge of module and Structure for 10kW. | 5 | Per set | 17,527.5 ₹87,637.5 Lowest | 19,280.25 ₹96,401.25 | 19,372.5 ₹96,862.5 |
Tender Value
₹1.2 Cr
EMD Value
₹1.2 L
Closing Date
28 Apr 2026, 4:00 pmClosed
EXECUTIVE ENGINEER,M.I.DIV. GUMLA
EXECUTIVE ENGINEER, M.I.DIV. GUMLA
Construction of Mukhyamantri Solar Lift Irrigation Scheme at Bitri,Block-P.A.E. Jari,Dist.-Gumla._(G_6)
2026_WRD_113261_1
WRD/MID/GUMLA/BD/SLI-01/26-27
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
335 days
GUMLA
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
₹1.2 L
6 Jun 2026
23 Apr 2026
29 Apr 2026
23 Apr 2026
28 Apr 2026
23 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Solar Module Mounting (Galvanised Steel) surface structure (for 10 kW) having Hot deep galvanised of Zinc thickness 80micron and as per IS4759 with C Channel $ anti theft with nut bolt of grade SS304,which should also withstand high wind velocity upto 150km/hr or as per MNRE. | - | Per set | - | - |
| - | 10kWp SPV module of 330wP or higher rating, which must have Specification as per IS 14286/IEC 61215 .The module must have to quilify IS/IEC 61730 part I $ II (or having mechanical load test of 5400Pa) for safety purpose.Module to Module wattage mismatch in SPV Array shall be +/-3% and to qualify IEC TS 62804-:2015 for the detection of potential induced degradation and warranted for output wattage not less than 90% in 10yrs and 80% at the end of 25yrs as per MNRE. | - | Per set | - | - |
| - | USPC controller with SPV module/VFD integrated with GPRS,having MPPT ,Protection IP 65 or above as per MNRE to run 10HP AC induction motor pump set . | - | Nos. | - | - |
| - | Solar cable 4 mm2 used as per IS 694 or as per MNRE. | - | M | - | - |
| - | copper cable 95 mm2 used as per IS 694 or as per MNRE. | - | M | - | - |
| - | Copper cable 16 mm2 for earthing as per IS 694 or as per MNRE. | - | M | - | - |
| - | Supplying and commissioning of earthing and lighting arrestor and surge protction as per IS 3043,IEC62305-3 and IEC 63227 for 10 HP AC induction motor pump set. | - | Nos. | - | - |
| - | 10 H.P. A.C induction motor Solar pump set of having performance with respect to Total Head,Maximum Current,Capacity, Voltage Range etc as per MNRE guidelines. | - | Nos. | - | - |
| - | Miscllaneous Accessories for Installation of 10H.P. A.C induction motor Solar Pump(L.S) | - | Per set | - | - |
| - | Supplying,installation and commissioning Charge of module and Structure for 10kW. | - | Per set | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
DOCUMENTS6.pdf
Tender Documents • 2.90 MB
BOQ_152939.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].