| 1 | L1₹1.5 CrAccepted-AOC III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | ₹1.5 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹1.5 Cr+₹7.8 L (5.33%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | ₹1.5 Cr+₹7.8 L (5.33%) | L2 | Rejected-Finance Other than lowest tenderer |
| 3 | L3₹1.6 Cr+₹8.7 L (5.91%)Rejected-Finance D NO 5 13 24 1 BEHIND SAHUWALA CYLINDERS IDA AUTONAGAR VISAKHAPATNAM 530 012 | VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | ₹1.6 Cr+₹8.7 L (5.91%) | L3 | Rejected-Finance Other than lowest tenderer |
| 4 | L4₹1.6 Cr+₹11.0 L (7.49%)Rejected-Finance 11 SANJIV BAUG SOCIETY NEW SHARDA MANDIR ROAD PALDI AHMEDABAD GUJARAT 380007 | AHMADABAD | GUJARAT | 380007 | ₹1.6 Cr+₹11.0 L (7.49%) | L4 | Rejected-Finance Other than lowest tenderer |
| 5 | L5₹1.7 Cr+₹27.1 L (18.4%)Rejected-Finance COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | ₹1.7 Cr+₹27.1 L (18.4%) | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
26 Mar 2022, 6:00 pmClosed
CWE (NW) Kochi
CWE (NW) Kochi PIN-682004
SPECIAL REPAIR/ REPLACEMENT OF BER LIFTS AT POWAR AND PANIGRAHI APARTMENTS AT PANAMPILLY NAGAR, INCLUDING 03 YEARS COMPREHENSIVE MAINTENANCE ,KOCHI
2022_MES_509026_1
CWE(NW)KOCHI/81271
Open Tender
Civil Works
Item Rate
270 days
Kochi
As per NIT
6 documents required · 6 mandatory
₹1,000
GE (NW) Kochi
₹2.2 L
Yes
18 Apr 2022
18 Feb 2022
28 Mar 2022
18 Feb 2022
26 Mar 2022
11 Mar 2022
18 Feb 2022 - 19 Mar 2022
Amount
SCHEDULE 'A' PART I
Taking down the existing old 13 passanger lift (G+13) including Machines / panels installed at the Machine room, lift car, rope doors, guide rails, etc. complete and transporting the same to MES store yard.(Powar Apartment) and stagging the same as directed by Engineer-in-charge in any location.
Taking down the existing old 8 passanger lift (G + 13) including Machines / panels installed at the Machine room, lift car, rope doors, guide rails, etc. complete and transporting the same to MES store yard. (Powar Apartment) and stagging the same as directed by Engineer-in-charge in any location.
Taking down the existing old 8 passanger lift (G + 12) including Machines / panels installed at the Machine room, lift car, rope doors, guide rails, etc. complete and transporting the same to MES store yard.(Panigrahi Apartment) and stagging the same as directed by Engineer-in-charge in any location.
Make :- (a) M/s Kone India (b) M/s Schindier India Pvt Ltd (c) M/s Kinetic Hyundai Elevator & Movement Technologies Ltd (d) M/s Hitachi Lifts India Pvt Ltd (e) M/s Mistubishi Elevator India Pvt Ltd (f) M/s Otis Elevators Company India Ltd (g) M/s Fujitech India Pvt Ltd (h) M/s Johnson Lifts Pvt Ltd (j) M/s Thyssenkrup Elevator India Pvt Ltd (k) M/s Omega elevators (l) M/s Hitachi Lifts India Pvt Ltd (m) M/s Escon Elevators Pvt Ltd (n) M/s LT Elevators Pvt Ltd (o) M/s IES Elevators The OEM or the agency authorised to carry out installation of lifts by OEM as per Sch 'A' provisions and relevant items of BOQ will be permitted to undertake maintenance of lifts. NOTE :-Existing Lift Well / Shaft Size : Approx 1800 mm (W) x 1800 mm (D), Pit Depth : 2000 mm Clear Door Opening : 800 mm (W) x 2000 mm (H) for 08 Passenger Lifts (544 Kg) and 2500 mm x 1800 mm pit depth 2000 mm clear door opening 900 mm x 2000 mm for 13 Passenger lifts (884 Kg)
Note for item No. 1.04 to 1.06 1. Work has to be executed in pre-occupied condition bldg and shall take care of all safety measures and avoid disturbances to the occupants while carrying out the work and all safety precautions to be carried out by the staff and the same to be ensured by contractor. 2. Contractor shall not dump any materials in the premises of the bldg which may cause hindrance to the users. 3. The lifts are to be installed in existing lift shaft / well. 4. Any addition / alteration cost required including all civil works like breaking of PCC, granite cladding,Plastering, New PCC, RCC etc and two coats of white washing in existing lift shafts complete after removal of old lifts for the erection of new lift is deemed to be included in quoted rate. 5. The following items shall be provided and the unit rate quoted above shall be inclusive for the same . 6. The lifts are to be replaced in pre-occupied buildings, hence one by one lifts to be dismantled and installed. (a) Gearless Electric motor, AC, 3 phase, 415V, 50Hz of suitable capacity including necessary cabling with ISI marked FRLHS Cable and fire resistant steel conduits as required. (b) Standard Wall / Floor mounted Lift Control Panel Board with suitable capacity 4 pole RCCB as incomer. (c) Mechanical guide rail in 'T' section with tongue and groove arrangement for smooth operation of car and counter weight. (d) Type of operation shall be single automatic push button type . (e) Minimum 4Nos SS Finish 3W LED Fittings and 02 Nos Blower Fan with Switch in lift car. (f) Minimum 12/13 Nos 7/9W LED Bulk Head Fittings for lift well lighting and 13 Nos 5Amps Plug Point incl point wiring with 1.5Sqmm FRLHS cables and control switches.The surface wiringshall be carriedout in suitable size steel conduits with necessary steel clamps,screws,rawal plugs etc. (g) Type of signal system - Hall button with digital hall position indicator, digital car position indicator in car fixtures in stainless stell face plates. (h) Capacity of ARD battery (High Amp Hour) should be suitable to perform minimum three continous rescue operation. (l) All necessary Grouting Plates / Bolts, Nuts, bolts, washers etc. (j) Provision of hoist way and governors rope and governor. (k) Provision of new buffer spring as per manufacturers design. (l) Provision of battery operated alarm and emergency light through inverter of suitable capacity having power back up for a period of minimum 30 minutes . (m) Drive - Permanent Magnet Gearless Machine frame fixed in the machine room. (n) Progressive type and bydirectional Over speed governor monitors the speed and triggers safety gears etc shall be installed in the machine room. (o) Necessary scaffoldings in lift well. (p) Pit Ladder.
Safety Measures:- (i) Overload relays. (ii) BMS Compatibility / Potential Free Contactors (Emergency Stop / Opening, Direction Up / Down, Failure, Main mode etc. and fuses. (iii) DO /DC Button and NS Button.(iv) High Quality Electrical Terminals / Sockets.(v) Limit switch with accessories on each doors / cage.(vi) Gravity / counter weight limit switches for top most position.(vii) Break Magnet of suitable size with manned released arrangements.(viii) Reverse Phase / Phase sequence corrector. (ix) lift door should be minimum 2 Hrs. fire resistance as specified in IS-14665.(x) Automatic condition monitoring of Polyurethane - Coated Steel Belt to ascertain it's mechanical integrity real time.(xi) Hoist way Access Prevention Special Safety Feature to prevent the elevator from operating after landing door is opened. (xii) The manufacturer have ISO 45001 certification on safety norms and necessary certificates to be produced.
Taking down exsiting MCCBs/ ELCBs with enclosure of any capacity and removing to store yard including making good disturbed surfaces complete all as specified and directed.
S&F MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 25 KA complete all as specified and as directed. Make : L&T/ Schneider/ Legrand/ ABB.
S&F Metal enclosure suitable for mounting MCCB/ RCCB/ ELCB, 4 pole, Switches for Surface and Flush mounting, IS-55 Protection complete all as specified and as directed.
S&F RCCB/ ELCB of earth leakage, over load and short circuit protection 4 pole, 63 Amps capacity of 100 mA breaking capacity complete all as specified and as directed. Make : L&T /Schneider/ Legrand/ ABB
M&L for Earthing complete with copper earth plate electrode 60×60cm.× 3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to copper strip of size 20x3 mm as earth lead upto 7.5 mtr distance and connected by means of bolts, nuts, check nuts and washers of brass or copper all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. Note :- (i) Copper Earth strip beyond 7.50 Mtr length shall be measured and paid separately.
M&L for earth continuity conductor or main earthing lead fixed to wall or batten or chases or burried gorund or drawn on walls or any other indicated situation for loop earthing strip 20x3 mm copper strip complete all as specified and as directed.
Supply and laying, testing & commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3.5 core in trenches or on walls / floors / roofs with necessary clamping materials all as per site requirement , including taking down old UG cable and making good the surface all specified and as directed .
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cables exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil all specified and as directed .
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cables exc 10 sq m on plan and n exc 1.5 m in depth and getting out on hard standing / road cutting all as per site requirement all as specified and as directed.
S&F GI tubing medium grade laid in trenches as cable protection of 50 mm dia with all fittings complete all as specified and as directed.
M&L for returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified and as directed.
M&L for removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point all as specified and as directed.
M & L for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers 15 cm before laying the cable and 8 cm after laying the cable all as specified and directed . Note :- Punned thickness shall only be measured and paid.
Supply & laying un-reinforced precast concrete cable cover class LV type 1, flat size 250mm x 150mm x 40 mm all as specified and as directed.
M&L for cold mixed bitumen (packet type) for making good the distrubed surface of road cutting ,rolling as directed by the Engineer-in-charge and finishing the surface matching with the exsiting surface all as specified and directed.
Total of Schedule 'A' Part I
Schedule 'A' Part II
All as per item No.2.01 above, but for Second year after expiry of defects liability period (ie for one year after completion of first year maintenance period vide item No.2.01 above)
All as per item No. 2.01 above for third year after expiry of defects liability period (ie for one year after completion of second year maintenance period vide item No 2.01 above)
All as per item No. 2.04 above for second year after expiry of defects liability period (ie for one year after completion of first year maintenance period vide item No 2.04 above)
All as per item No. 2.04 above for third year after expiry of defects liability period (ie for one year after completion of second year maintenance period vide item No 2.04 above)
All as per item No.2.07 above, but for Second year after expiry of defects liability period (ie for one year after completion of first year maintenance period vide item No.2.07 above)
All as per item No.2.07 above, but for Third year after expiry of defects liability period (ie for one year after completion of second year maintenance period vide item No.2.07 above) Note:- AMC for the Item No. 2.01 to 2.09 above shall be concluded from OEM and necessary certificate should be submitted to the department on commencement of maitenance period.
Total of Part II
M/s Dhapola Elevator and Engineering
INDUSTRIAL ENGINEERING SYSTEMS
Omega Elevators
Escon Elevators Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .