| Sl No | Description | Qty | Unit | TEKMEN JAL SOLUTIONS LLP |
|---|---|---|---|---|
| 1.01 | Earth work in excavation in trenches for foundation and for pipes cables etc. in ordinary soil including fitup to 1.5m and dressing of sides and ramming bottoms and disposal of surplus excavated earth as directed by the engineer with in a lead of 50m (2.6.1 D.S.R. 2023) | 423.63 | cum | 63,544.5 ₹74,982.51 |
| 1.02 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (2.26.1 D.S.R. 2023) | 240.49 | cum | 25,732.43 ₹30,364.27 |
| 2.01 | Filling available excavated earth (excluding rock) in trenches ,plinth,sides of foundation etc . in layers not exceeding 20cm in depth ,consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m (2.25 D.S.R. 2023) | 296.54 | cum | 49,225.64 ₹58,086.26 |
| 2.02 | Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and irection of Engineer -in - charge.(2.38 D.S.R. 2023) | 1,079.98 | cum | 2,81,874.78 ₹3.3 L |
| 2.03 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.(2.27 D.S.R. 2023) | 270 | cum | 4,85,730 ₹5.7 L |
| 3.00 | Providing and laying in position cement concrete 1:4:8 (1cement :4 coarse sand:08graded brick aggregated 40mm .nominal size.) excluding the cost of centering and shuttering - All work upto plinth level. (4.1.8 D.S.R. 2023) | 137.97 | cum | 7,96,362.84 ₹9.4 L |
| 4.00 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement :3 coarsesand : 6graded stoneaggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.(4.17 D.S.R. 2023) | 67.5 | sqm. | 42,660 ₹50,338.80 |
| 5.01 | Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 350 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works upto plinth level.(5.33.1.2 D.S.R. 2023) | 173.28 | cum | 14,17,776.96 ₹16.7 L |
| 5.02 | Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 350 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor III level.(5.33.2.2 D.S.R. 2023) | 224.26 | cum | 19,02,621.84 ₹22.5 L |
| 6.01 | Centering shuttering including strutting, propping etc. and removal of form work. Foundation upto plinth. (5.9.1 D.S.R. 2023) | 280.2 | sqm. | 93,026.4 ₹1.1 L |
Tender Value
Refer Docs
EMD Value
₹17 L
Closing Date
5 Mar 2026, 5:00 pmClosed
DGM (EM)
Office of DGM(E/M) UAPMB Dehradun
SITC of 500MT 05nos.x100MT for Fruit and Vegetables and 100MT 01no.x100MT for Frozen Produce Cold Storage 100kwp roof top ongrid Solar power plant 82.50 Kva DG Set 160 KVA Stabilizer 160KVA Transformer etc at Khatima mandi
2026_UAPMB_92369_1
137/24.02.2026
Open Tender
Miscellaneous Works
540 days
Khatima
Please refer Tender documents.
3 documents required · 3 mandatory
₹4,720
DGM EM
₹17 L
16 May 2026
25 Feb 2026
6 Mar 2026
25 Feb 2026
5 Mar 2026
26 Feb 2026
Earth work in excavation in trenches for foundation and for pipes cables etc. in ordinary soil including fitup to 1.5m and dressing of sides and ramming bottoms and disposal of surplus excavated earth as directed by the engineer with in a lead of 50m (2.6.1 D.S.R. 2023)
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (2.26.1 D.S.R. 2023)
Filling available excavated earth (excluding rock) in trenches ,plinth,sides of foundation etc . in layers not exceeding 20cm in depth ,consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m (2.25 D.S.R. 2023)
Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and irection of Engineer -in - charge.(2.38 D.S.R. 2023)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.(2.27 D.S.R. 2023)
Providing and laying in position cement concrete 1:4:8 (1cement :4 coarse sand:08graded brick aggregated 40mm .nominal size.) excluding the cost of centering and shuttering - All work upto plinth level. (4.1.8 D.S.R. 2023)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement :3 coarsesand : 6graded stoneaggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.(4.17 D.S.R. 2023)
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 350 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works upto plinth level.(5.33.1.2 D.S.R. 2023)
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 350 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor III level.(5.33.2.2 D.S.R. 2023)
Centering shuttering including strutting, propping etc. and removal of form work. Foundation upto plinth. (5.9.1 D.S.R. 2023)
plinth Beam (5.9.6 D.S.R. 2023)
COL SUPER STRUCTURE (5.9.5 D.S.R. 2023)
Slab (5.9.3 D.S.R. 2023)
Lintel+sunshade (5.9.5 D.S.R. 2023)
Reinforcement for R.C.C work including straighting,cutting,bending ,placing in position and bending all complete Thermo-Mechanically Treated bars.(5.22.6 D.S.R. 2023)
230 th Brick work with brick of class designation 75 in foundation & plinth in cement mortar 1:6 (6.1.2 D.S.R. 2023)
Brick work with F.P.S bricks of class 75 in super structure above structure above plinth level up to floor five level in all shapes and sizes in cement mortar 1:6 (1 cement : 6 coarse sand) (6.4.2 D.S.R. 2023)
Half brick masonry with F.P.S bricks of class designation 75 in superstructure above plinth level up to floor five level in cement mortar 1:4 ( 1 cement : 4 coarse sand) (6.13.2 D.S.R. 2023)
Extra for providing and placing in position 2 Nos. 6mm dia. M.S.bars at every third course of half brick masonry (with F.P.S.bricks). (6.15 D.S.R. 2023)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineerin-charge:(profile c) Fixing with adjustable lugs with split end tail to each jamb. (D.S.R.10.14.2.1 2023)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. (D.S.R.9.21.1 2023)
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws, Second class teak wood. (D.S.R.9.27.1.1.1 2023)
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.(9.83 D.S.R. 2023)
Providing and fixing chromium plated brass handles with necessary screws etc. complete: 75 mm. ( 9.92.3 D.S.R. 2023)
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete, 100x10 mm. (9.97.5 D.S.R. 2023)
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Single rubber stopper. ( 9.101.1 D.S.R. 2023)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. (11.41.2 D.S.R. 2023)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement basedhigh polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 500x500 mm. (11.47.1 D.S.R. 2023)
12mm thick plaster on the plain in side of mix 1:6 ( 1 cement : 6 fine sand) mortar. (13.1.2 D.S.R. 2023)
15mm thick plaster on the plain in side of mix 1:6 ( 1 cement : 6 fine sand) mortar. (13.2.2 D.S.R. 2023)
6mm thick cement plaster of ceiling of mix 1:3 ( 1 cement : 3 fine sand) mortar.(13.16.1 D.S.R. 2023)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.(13.80 D.S.R. 2023)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. New work (two or more coats) over and including water thinnable priming coat with cement primer. (13.41.1 D.S.R. 2023)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (13.47.1 D.S.R. 2023)
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.(10.26.1 D.S.R. 2023)
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. (10.31 D.S.R. 2023)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete. (10.25.1 D.S.R. 2023)
Welding by gas or electric plant including transportation of plant at site etc. complete.(10.22 D.S.R. 2023)
Providing and fixing bolts including nuts and washers complete.(10.20 D.S.R. 2023)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. (10.16.1 D.S.R. 2023)
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer-in- charge, (area of grill to be measured).(10.9 D.S.R. 2023)
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover.(10.6 D.S.R. 2023)
Providing and fixing ball bearing for rolling shutters.(10.7 D.S.R. 2023)
Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10.00 sqm and upto 16.80 sqm in the area.(10.8.1 D.S.R. 2023)
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m². (12.1.3 D.S.R. 2023)
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. (D.S.R 17.3.1)
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. (D.S.R 17.7.2 )
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern.(D.S.R 17.4.1)
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size (D.S.R 17.1.1)
Providing and fixing G.I. pipes complete with G.I. fittings andclamps, including cutting and making good the walls etc. Iinternal work - Exposed on wall 15mm dia nominal bore. (D.S.R 18.10.1)
50 mm dia. nominal bore. (D.S.R 18.10.6)
Providing and fixing uplasticised PVC connection pipe with brass unions : 15mm nominal bore. (D.S.R 18.21.2.1)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(D.S.R 18.48)
Providing and fixing soil, waste and vent pipes : Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 100MM.(D.S.R 17.35.1)
75MM (D.S.R 17.35.2)
Providing and fixing plain bend of required degree. 100 mm Sand cast iron S&S as per IS : 3989 (D.S.R 17.39.1.2)
Providing and fixing single equal plain invert branch of required degree :100x100x100 mm Sand cast iron S&S as per iron 1729 (D.S.R 17.50.1.1)
Providing and fixing collar : 100 mm , Sand cast iron S&S as per IS - 3989 (D.S.R 17.57.1.2)
Providing and fixing plain bend of required degree. 75 mm. Sand cast iron S&S as per IS - 3989 (D.S.R 17.39.2.2)
Sand cast iron S&S as per IS - 3989 75x75x75 mm. (D.S.R 17.50.2.2)
Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 100 mm. Sand cast iron S&S as per IS - 3989 (D.S.R 17.47.1.2)
Providing and fixing 600 x 455 mm. bevelled edge mirror of Saint Gobin or Modi float glass complete with 6 mm. thick hard board ground fix to wooden cleats with CP brass screws and washers etc. complete.(D.R.S. 17.31)
Providing and fixing terminal guard : Sand cast iron S&S as per IS - 3989 (D.S.R. 17.56.1.2)
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : Sand cast iron S&S as per IS - 3989 (D.S.R 17.60.2.1)
Providing & Fixing C.P. brass bib cock parryware make (D.S.R 18.15.1)
Providing & Fixing C.P. brass Long boddy bib cock (D.S.R 18.51.1)
Providing and fixing PTMT pillar cock of approved quality and colour. (D.S.R 18.56.2)
Providing & Fixing C.P. brass stop(conceald) (D.S.R 18.52.1)
Providing & fixing c.p. soap dish parryware make (D.S.R 18.65)
Provding & Fixing C.P Towel rail parryware make (D.S.R 17.73.1)
Provisiding & Fixing C.P Paper Holder parryware Make (D.S.R 17.34.1)
Providing & fixing Over Head Shower parryware make (D.S.R 18.64)
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 80 mm dia nominal bore.(18.12.8 )
Providing and fixing gun metal gate valve with C.I. wheel of approved quality, (screwed end) : 80 mm nominal bore. (18.17.6 )
Constrcution of septic tank & soakpit. (AS PER AOR)
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 100 mm dia. R.C.C. pipe (19.6.1)
300 mm dia. R.C.C. pipe (19.6.4)
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (D.S.R. 19.30.1.1)
Construction of Rain water harvesting tank (AS PER A.OR)
Construction of drain including all labour & material complete in all respects. (AS PER A.O.R)
Construction of paver including all labour & material complete in all respects. (AS PER A.O.R)
Construction of road including all labour & material complete in all respects
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group c (1.8.3)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (1.14.1)
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (1.14.2)
2 X 4 sq. mm + 1 X 4 sq. mm earth wire (1.14.3)
Supplying & Fixing of following piano type switch/socket on the existing switch box/cover including connections etc. as required. 5/6 amps switch (1.23.1)
3 pin 5/6 amps outlet (1.23.4)
Supplying and fixing metal box of 180 mm x 100 mm x 60 mm deep(nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 anos socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. (1.30)
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. (1.33)
Supplying and fixing PVC batten/ angle holder including connections etc. as required. (1.58)
Earthing with G.I earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7mtr. Long etc. (with charcoal or coke and salt) as required. (5.4)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) (5.9)
Providing and Laying earth connection from earth electrode with 6 SWG dia G.I in 15mm dia G.I. Pipe FRL Som earth electrode including connection with copper thimble excavation and re-filling as required. (5.12)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 way , Double door (2.3.1)
12 way , Double door (2.3.3)
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (2.18)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole (2.10.1)
Supplying and fixing 40A rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (2.12.1)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (1.25)
Providing and fixing circular/Hexagonal cast iron or M.S sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12mm dia M.S bar bent to shape as per standard drawing. (10.18)
Supplying and making end termination with brass compression gland and aluminium lugs for 3½ X 95 sq. mm (45mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (9.1.24)
Supplying and making end termination with brass compression gland and aluminium lugs for 3½ X 185 sq. mm (45mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (9.1.27)
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 70sqmm 3 core, XLPE aluminium conductor cable of 11 KV grade as required (10.5.1)
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size ) foundation including excavation and refilling etc. as required. (13.1)
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. (13.10)
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.
c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. (Solar DSR)
Supply and fixing of LED Tube Light with batten suitable for up to 1 X 20 watt LED tube light fitting including tube on Surface complete in all respect.
Supply of 1200 mm ceiling fan complete with all accessories.
Supply and Fixing of 300 sq mm Exhaust Fan with complete of all respect.
S/L of 1800 mm. X 900 mm. 12 mm thick chequered rubber matting of tested quality.
set running MCB of suitable capacity. Instrument fuses. Incoming and out going Terminals optional: Anti vibration pad 6 nos Dunlop make i/c inspection of direction safely, U.A i/c all taxes and cartage, Testing as per direction of E/I with battery. The power coated Acoustic Enclosure (canopy) for 82.5 KVA/66KW water cooled Generator set complete with all its fittings and latest CPCB norms of 75dB(A)@1mt distance and as per testing guidelines of CPCB IV. Supply of suitable size fuelling from service tank to engine and return i/c elbows, sockets etc 9M Supply of suitable size M.S piping i/c bends, flanges, sockets, flexible, asbestos, roping for lagging recommended area. 4M.
Ceasefire 6kg fire extinguisher Mono Ammonium Phosphate Powder 90, stored pressure type, pressure gauge, applicable on class A,B,C and electrically started fire, A rating-6A, B rating - 183B, Helium leak detection tested, ISI, LPCB and CE approved, 6 years warranty.
Ceasefire 4.5kg Aluminium Co2 gas type fire extinguisher, trolley mounted, easy weight management, used unused mechanism squeeze grip, gross advanced frost-free horn to disperse gas, removes risk of freeze burn. State of the art ready/used indicator, available in portable and trolley mounted variants, ISI, LPCB and CE approved, 10 years warranty.
S/F of fire bucket around bottom made of G.I sheet 9-11 litres capacity duly painted as per fire brigade desgn, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer in charge.
S/F of shock treatment chart (prescribed under I.E rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work.
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 150Watt. Confirming to IP 66 and above Protection complete in all respect. Makes- Havell's, Philips.
Supply of Plastic Crates of Capacity 20 Kg
Supply of Hand Pallet Truck of Capacity 2.50 Ton for Industrial purpose.
M & L for one coat of aluminium paint of approved quality including preparation of existing old painted surface of steel tubular poles LT complete including flat iron clamps, bracing, cross arms etc and numbering of poles with white synthetic enamel paint over a circular painted base and strip marking paint up to a height of 4 feet with Red & Yellow five bands with synthetic paint (strip of 1 feet height each) complete all as specified and directed.
Supply and laying of 70 sq.mm. 3core HT aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
2.5 sq. mm 3 core
4 sq. mm 3 core
6 sq. mm 3 core
S.I.T.C of transformer 160KVA out door type 3 phase 50 Hz oil immersed naturally cooled double wood with copper conductors step down core type transformers having a no load voltage ration 11/0.433 volt group ref. Dy -11 having tapping 5% on HT side for HT variation and leads to be brought out On/Off circuit tap changing switch with locking device and outside indicator arrangement. The transformer shall have LT cable box on medium voltage side. The transformer will be confirming to IS-1180(Part-I) OS-2026 with latest amendments complete with following fittings/accessories i/c inspection of Dy director Electrical; safety, confirming ISO 9001.(approved GTP by UPCL)
S/construction of two poles sub-station structure comp with all accessories reqd. for proper comp of work on the H.T pole 11 mtrs long SP-55 (a) Supply of 11m long H.T pole i/c grouting concreting in 1:4:8 cement, c/sand OBB and plain thing with all materials. (b) Stone paid (c) S/F of M.S channel 100*50mm for disc with fitting and dropper (d) M.S bolts & nuts and washers (e) S/F of danger board with clamps (f) fabrication (g) S/F of 11 KV T.P.M.O complete in all respects. (h) S/F of 11 KV D.C. fuse set of appd make complete in all respects. (i) S/F of 11 KV pin insulator with PIN. (j) S/F of 11 KV disc. with fitting on channel. (k) S/F of 50x6mm flat clamp and packing piece for fitting channer droper channel. (l) Painting of structure with appd paint with one coat of red oxide primer, 2 coats of A-1 paint with post office red enamel and from top top at a distance of 2 mtrs. (m) earthing i/c all complete
S/F of M.S. steel tubular pole 11 meter long complete in all respects.(Approved GTP by UPCL)
Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects.
S/L of following aluminum conductor XLPE insulated armoured served sheathed cables 1100 V grade Laying of on number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade . The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 95sq. mm 3-1/2 size
185 sq. mm 3-1/2 size
16sqmm 2 core size
Supply of Feeder Piller panel will be of low tension, outdoor type, floor mounting, dust and vermin proof with IP54 protection and bus bar of Electro grade Aluminium suitable for 3 phase 4 wire supply. The panel will be designed for front access and cable entry from bottom. Nusbar 800A Aluminium, busbars will be insulated with heat shrinkable PVC colour Code sleaves. The panel is made out of 2mm/1.6thk. GI sheets, Pre-treated and powder coated with Siemens gray shade REAL 7035 stand for panel 50x50x5mm angle with minimum 400mm height from ground incoming 320 A FP MCCB with extended rotary handle- 1 nos.320 A change over switch with extended rotary handle-1 no ,100 A MCCB with ROM-2nos. 63 A MCCB with ROM-5 nos.Outgoing RYB Phase indication lamp, AMP meter, ASS, Volt meter, VSS, CTs & control MCBs as required.
S/F of PUF Panel 120 mm thick as per specification. Density of PUF: 40-42kg/m3 PUF thickness : 100mm Metal skin (PPGI) : Hot Galvanized Metal (Sendmizir), 22 micron polyester Coated, white colour Thickness of sheet : 0.6mm U value (100mm) : 0.21W/m2 Compressive Strength (at 10% deformation) : 2.1Kg/Cm2 Adhesive Strength : 3.0 Kg/Cm2 Tensile Strength : 4.0 Kg/Cm2 Dimensional Stability (48Hrs.) -25 Deg C : 0.1% + 38 Deg C & 90% RH : 0.1% +90 Deg C : 0.4% Temperature Range : -180 to 100 Deg C Thermal Conductivity : 0.02 W/mk At 10 Deg C mean Temp.
PUF Panel 60 mm Thick Density of PUF: 40-42kg/m3 PUF thickness : 100mm Metal skin (PPGI) : Hot Galvanized Metal (Sendmizir), 22 micron polyester Coated, white colour Thickness of sheet : 0.6mm U value (100mm) : 0.21W/m2 Compressive Strength (at 10% deformation) : 2.1Kg/Cm2 Adhesive Strength : 3.0 Kg/Cm2 Tensile Strength : 4.0 Kg/Cm2 Dimensional Stability (48Hrs.) -25 Deg C : 0.1% + 38 Deg C & 90% RH : 0.1% +90 Deg C : 0.4% Temperature Range : -180 to 100 Deg C Thermal Conductivity : 0.02 W/mk At 10 Deg C mean Temp.
PUF Slab for Floor Insulation (60+60) mm Thick, including Water Proofing (APP Membrane 3 mm Thick with Bitumen Primer & Coat) and PCC finally finished with Kota Stone complete in all respects.
Manual Sliding Door (For Cold Chambers) 120 mm Thick with Mounting Frame and all Accessories (1500 x 2400 mm) complete in all respects.
Manual Sliding Door (For Freezer Chamber) 120 mm Thick with Mounting Frame, Heaters and all Accessories (1500 x 2400 mm) complete in all respects.
Manual Sliding Door (For Dock & ANTE Room) 60 mm Thick with Mounting Frame and all Accessories (2000 x 2400 mm) complete in all respects.
S.I.T.C. of Pre fabricated structure Heavy Duty Mezzanine Cold Rolled Section Structure With GI Grating, Stair Case, Hand Railing, Vertical and Horizontal Load Bearing Members, Polyester Epoxy Powder Coated Finish, 1000 kg/m2 UDL complete in all respects.(Approved by structural engineers)
S.I.T.C of Refrigeration System (For Cold Chamber) for storing fresh fruits & vegetables, internal room dimensions 7.3x8.5x6.9m, loading rate/day 5-10%, pull down time 36-48hrs, incoming product temp. (+)25to (+)35ºC, final product temp. (+)2ºC to (+)4ºC{+/-2ºC}, desired room temp. (+)2 to (+)6ºC, ambient temp. 40ºC, 3 No Air cum Water Cooled (Hybrid) DX Refrigeration Unit with Hermetic Reciprocating Compressor, Make: Emerson/ Equivalent, compatible with R407 C Refrigerant, Capacity 14.5 kW with Electrical Panel, Input Power 5.8 kW & Air Cooling Unit (550 mm Dia Fan 2 No) Electrical Defrost, 6 mm Fin Spacing for Evaporator Coil, MOC: 280 GSM Powder Coated, Electrical & Refrigeration Controls etc. complete in all respects.
S.I.T.C of Refrigeration System (For Freezer Chamber) for storing frozen products (peas/sweet corns etc.), internal room dimensions 7.3x8.5x6.9m, loading rate/day 5-10%, pull down time 24-36hrs, incoming product temp. (-)14ºC to (-)16ºC, final product temp. (-)18ºC {+/-2ºC}, desired room temp. (-)20ºC{+/-2ºC}, ambient temp. 40ºC, 2 No Air cum Water Cooled (Hybrid) DX Refrigeration Unit with Semi Hermetic Reciprocating Compressor, Make: Frascold/ Bock/ Equivalent, compatible with R407 C Refrigerant, Capacity 12.5 kW with Electrical Panel, Input Power 12.7 kW & Air Cooling Unit (500 mm Dia Fan 2 No) Electrical Defrost, 10 mm Fin Spacing for Evaporator Coil, MOC: 280 GSM Powder Coated, Electrical & Refrigeration Controls etc. complete in all respects.
S.I.T.C of Digital Control Panel with Temperature & RH Display, Auto/ Manual Functions with required wiring for units etc. complete in all respects.
Supply, Laying and Fixing of Interconnecting Refrigeration machineTubing (MOC Copper) duly Insulated with 19 mm Thick EPDM Sleeves covered with Aluminium Tape & S/F required load line DB with Copper Wiring for Refrigeration System (indoor, outdoor machines to load line DB) complete in all respects.
Supply installation of Internal Lighting (Vapor Proof, LED light fitting) For Cold room – 05 NOS Ante Room-01 and Docking area as per required lumens -01 No. complete with wiring & switch board as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.80 MB
Tender.pdf
Tender Documents • 0.45 MB
Form.pdf
Tender Documents • 1.97 MB
Drawing.pdf
Other Document • 0.56 MB
MAKE.pdf
Other Document • 0.14 MB
BOQ_109341.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid