Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST REASONABLE BID | |
| 2 | L2₹22.5 L+₹10,628 (0.47%)Rejected-Finance 10 ABHAY GARH SCHEME CENTRAL SCHOOL AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹23.1 L+₹64,282 (2.87%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹23.6 L+₹1.2 L (5.18%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹24.9 L+₹2.5 L (11.1%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
25 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (ARMY) JODHPUR
CWE (ARMY) JODHPUR, MULTAN LINE, ARMY AREA, JODHPUR, PIN-342010
REPAIR AND MAINTENANCE OF 11 KV NETWORK AND OTHER CONNECTED WORK AT SECTOR C,E AND F AREA IN ARMY AREA UNDER GE (A) UTILITY JODHPUR
2022_MES_554687_1
82223/44/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
JODHPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE (ARMY) UTILITY
₹66,000
Yes
9 Jan 2023
27 Sept 2022
29 Oct 2022
27 Sept 2022
25 Oct 2022
11 Oct 2022
28 Sept 2022 - 10 Oct 2022
Amount
Surface dressing Not exceeding 15 cm deep in any type of soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation/ pipes/ cable etc, not exceeding 10sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation/ pipes/ cable etc, not exceeding 10sqm on plan and not exceeding 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
Removing of excavated surplus soils, not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, in soil complete all as specified and directed.
M&L for Tibba sand cushioning for PVC/XLPE cable punning to provide required covers all as specified and directed. Note:- Only punned thickness shall be measured and paid
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1, flat size 300mm x 180mm x 40mm and abutting each other with gap between adjacent precast concrete cable cover not exceeding 10mm over underground cables for protection complete all as specified and as directed.
M&L for Auguring/ Drilling /Boring of holes under road, pavement, hard standing by trenchless technology by manual /machine, including fixing of HDPE pipe of 100 mm bore complete all as specified and directed.
M&L for GI tubing of size 100 mm bore light grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall complete all as specified and directed.
Supply and laying & testing cable XLPE installed screened PVC bedded, galvenised steel strip or wire armoured electric power cable (heavy duty) 11000 V grade with stranded aluminium conductor of size 95 sqmm 3 core laid in trenches/ducts /encased in GI pipe /fixed to pole complete all as specified and directed by Engineer-in-Charge.
M&L for prestressed cement concrete poles, 11 mtr long of size 152mm x 152mm at top and 152mm x 260mm at bottom, class-9, conforming to relevant latest IS including refixing of connecting items complete all as specified and as directed.
Dismantling of existing any type and any size of broken poles including demolishing of concrete of any description and in any position complete all as directed at site. NOTE- Cost for the removal of broken pole and demolished concrete out side defence land is deemed to be included in quoted rate and site should be clear from any debris.
M&L for Cement concrete 1:3:6, type C1, using 20 mm graded stone aggregate as in pedestal of poles/copping including necessary frame work, fair finishing to exposed surfaces using extra cement complete all as directed.
M&L for Cement concrete 1:3:6, type C2 using 40 mm graded stone aggregate as in foundation of pole /struts/stay assembly etc complete all as directed by EIC
S&F in replacement of Danger notice plate of 1.6 mm thick, mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in single red colour and fixed with MS clamps, bolts and nuts of approved size for HT pole of size 25 x 20 cm size including complete fixing arrangement with iron strip 25mm x 3mm with nut, bolts and paints etc complete all as specified and directed by EIC.
Dismantling of insulators any type any size from existing poles all as directed.
Fixing only of any type any size of dismantled insulators (serviceable insulators retrieved from item no 16 above) complete all as directed at site.
S&F Pin type porcelain insulator, vitreous white, brown or green including one galvanised mild steel spindle two GI washer and GI Nuts 150 mm height 150 mm dia for 11000 volts grade complete all as specified.
S&F Single disc type porcelain vitreous, white, brown or green 145mm height and 255mm dia ball and socket type, three disk assembly for tension with tension clamp for conductor working pressure 11000 volt grade and max failing load 45 KN complete all as specified and as directed.
M&L in replacement of stay assembly complete with 230mm x 230mm x 6mm thick plate and 20 mm dia stay rod all as shown in Elect Plate NO-1 of SSR-Part -1 including stay wire of appropriate size all as specified and directed by Engr-in-charge. Note: - Excavation, PCC, stay wire, Loop insulator, clamps etc shall be measured and paid separately under respective items.
S&F Loop type porcelain insulator, vitreous white, brown or green including one galvanised mild steel spindle, two GI washer and GI Nuts 90mmx140mm, clearance of hole 25.5mm complete all as specified.
S&F Mild steel sections as cross arms, bracing, supports, back plate & clamps fabricated from structural steel section including nuts, bolts, washer cutting, welding bending cold or hot, drilling holes for bolts in any shape for bolts in any shape or size inclusive of painting with 2 coats of aluminum paint over a coat of primer complete all as specified
M&L for end jointing kit, indoor type, heat shrinkable, 95 sqmm 3 core suitable for 11 KV (E), XLPE insulated electric power cable complete all as specified and directed.
M&L for end jointing kit, outdoor type, heat shrinkable, 95 sqmm 3 core suitable for 11 KV (E), XLPE insulated electric power cable complete all as specified and directed.
M&L for straight through jointing kit, outdoor type, heat shrinkable, 95 sqmm 3 core suitable for 11 KV (E), XLPE insulated electric power cable complete all as specified and directed.
Under ground Cable Testing / fault detection by authorised agency with Computerised Fault Detection Van complete to find the fault location for 33/11 KV rated UG cables as directed by Engineer in Charge at site. Note :- Any excavation and earth work and cable joint work involved will be measured and paid separately against respective item.
S&F in replacement of male contact/moving contact blade complete suitable for 11 KV GOD vertical type complete all as specified and as directed.
S&F in replacement of female contact/moving contact blade complete suitable for 11 KV GOD vertical type complete all as specified and as directed.
S&F switch air break, gang operated, triple pole, mechanically operated, mounted on insulator (09 insulators) and steel frame with operating mechanism including spring loaded mechanism set of three working from ground level, including locking arrangement of current rating up to 200 Amps, 11000 volt complete all as specified and as directed.
S&F in replacement swing out expulsion fuse assembly, single pole (drop out fuse) for 11000 Volts of capacity 100 Amps complete with MS channel, post insulators etc complete all as specified and as directed.
Repairing of damaged/unserviceable gang operate devices 11/33 KV male & female contacts, flexible jumpers, MS jumper carrier and back connector plate including cleaning and greasing of complete contacts of GOD unit, DO fuse unit and reluging of aluminium conductors connected to top & bottom contacts of GOD and DO units including welding and threading of operating rod mechanism complete making serviceable all as directed by Engr-in-Charge. Note:- (i) Necessary parts like knife, male/female contacts and aluminium conductor for jumpering, GI pipe and handle will be measured and paid separately against respective item. (ii) Rates for Welding machine, threading arrangements, grease, jumper and binding wire deemed to be included in quoted rates.
M&L for Trimming and pruning of one tree complete cutting of all branches of any dia but not exceeding 3" girth up to a safe distance from the over head lines complete all as directed at site and disposal of branches/bushes to a distance and clearing the site all as directed by Engr-in-charge. NOTE:- 1. The necessary man power, tool & plant, cutting tools and JCB required for cutting/pruning of branches is deemed to including in the rate quoted for the job. 2. Proper shut down will be taken by the authorised rep only. 3. T&P / Vehicle mounted Telescopic Ladder required for carry out the work at a height up to 15 meter will be issued to contractor under Schedule 'C' as demanded by contractor.
M&L for ZEBRA painting of PCC poles 9/11 m long along with road unto 1.5 m height from pedestal, with two coats of enamel synthetic paints in 30 cm height including painting of pole coping with white paint complete all as specified and as directed.
M&L for writing pole number of minimum 10 cm height with black paint over base of yellow paint on PCC/steel poles of HT supply complete all as specified and as directed.
S&F in replacement of gap less metal oxide type Lightning Arrestor (LA), 9.0 KV grade discharge current 65 KA, distribution class conforming to IS-3070 including taking out old unserviceable LA assembly complete all as specified and directed by Engr-in-Charge.
Supply, fixing & stringing in replacement of ACSR conductor on poles with jumpring and binding with aluminium conductors and in yards with and including aluminum connectors of required shape and suitable for conductor size all as directed by Engr-in-Charge.
M&L in replacement of cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia complete all as directed by EIC.
Supply and fixing of weather proof flexible acrylic board 2mm thick of size not less than 450mm x 300mm duly marked for shut down / sub station nomenclature etc as directed by EIC including fixing arrangement nut, bolt, washers etc complete all as specified and as directed. Note:- Marking / details reflected on each board shall be approved by EIC before order to manufacture.
RISING ELECTRICALS
SANJOLI CONSTRUCTION COMPANY
M/s R K Enterprises
Nvimal Engineers and Contractor
Sachiyay maa Electricals
Shri Electrical Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .