Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC 37 2 INDIRA COLONY CHUKHUWALA DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC AOC accepted. | |
| 2 | L2₹35.4 L+₹89,415 (2.59%)Rejected-AOC H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L2 | Rejected-AOC AOC rejected. | |
| 3 | L3₹35.9 L+₹1.4 L (4.06%)Rejected-AOC 11 CIVIL LINES ROORKEE 247667 DISTT HARDWAR UK | HARIDWAR | UTTARAKHAND | 247667 | L3 | Rejected-AOC AOC rejected. | |
| 4 | L4₹36.8 L+₹2.3 L (6.78%)Rejected-AOC NO 26 SRI GANESH 7TH CROSS BDS NAGAR DIBBUR RAMAIAH LAYOUT K NARAYANPURA MAIN ROAD BANGALORE 560 077 | BENGALURU URBAN | KARNATAKA | 560077 | L4 | Rejected-AOC AOC rejected. | |
| 5 | L5₹37.2 L+₹2.7 L (7.73%)Rejected-AOC | L5 | Rejected-AOC AOC rejected. |
Tender Value
₹44.9 L
EMD Value
₹89,800
Closing Date
3 Jun 2023, 6:00 pmClosed
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Repair/replacement of Internal Electrification at MH,Cheerbagh,and Anarwala area under AGE EM-II of GE Dehradun.
2023_MES_593599_1
8602/A/E8
Open Tender
Civil Works
Item Rate
180 days
GE Dehradun
Class D Cat b (i)
8 documents required · 8 mandatory
₹500
GE Dehradun
₹89,800
Yes
19 Jul 2023
6 May 2023
5 Jun 2023
6 May 2023
3 Jun 2023
20 May 2023
Amount
Taking down carefully copper /aluminium point wiring (light, fan , socket or power ) any type including unscrewing from board,fitting and fixture such as switches, ceiling roses, holders, regulators sockets ,light fittings etc removing materials from site and making good disturbed with the existing surfaces complete all as directed.
Material and labour for Point wiring with1100 Volts, grade 1.5 Sqmm. (nominal area) ,PVC insulated but unsheathed multistranded copper conductor single core FRLS cable drawn through and including non metallic medium duty rigid PVC concealed conduit (medium duty) 20mm dia or higher size complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc including pressed iron/steel suction box of thickness1.2mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly including cutting chases for conduits and sinking's for boxes and making good to walls,floors etc complete all as specified and directed by Engr.-in-charge of following. Note : The wiring to be done as per IE rule and maintain colour code accordingly.
One light/Exhuast fan point , controlled by one way switch.
One fan point , controlled by one way switch through Regulaor
One bell point , controlled by bell push switch.
One three pin 5 Amp socket on same board with other switches
One three pin 5 Amp socket on independent board
two way light point controlled by two two way switch
Add to item no 2.01 for each additional light point on the same switch
All as per Item No 2 mentioned here-in- before but one three pin 15 Amps switch socket out let on the independent board with 2.5 sq mm PVC insulated FRLS copper conductor and 2.5 Sqmm FRLS copper conductor for continuous earthing complete.
Material and labour for Point wiring with1100 Volts, grade 1.5 Sqmm. (nominal area) ,PVC insulated but unsheathed multistranded copper conductor single core FRLS cable drawn through existing steel/PVC conduit including pressed iron/steel suction box of thickness1.2mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover and 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly and making good disturbed surfaces etc complete all as specified and directed by Engr.-in-charge of following. Note :(i) The wiring to be done as per IE rule and maintain colour code accordingly.
One light/Exhuast fan point , controlled by one way switch.
One fan point , controlled by one way switch through Regulaor
One three pin 5 Amp socket on independent board
One bell point , controlled by bell push switch.
two way light point controlled by two two way switch
All as per Item No 4 mentioned here-in- before but one three pin 15 Amps switch socket out let on the independent board with 2.5 sq mm PVC insulated FRLS copper conductor and 2.5 Sqmm FRLS copper conductor for continuous earthing complete.
Supply and fix Switch piano flush type single pole one way 230 Volts 6 Amp complete all as directed.
Supply and fix Switch piano flush type single pole two way 230 Volts 6 Amp complete all as directed.
Supply and fix Socket outlet 3 pin , 230 Volts 5/6 Amps flush type multipurpose 5 pin complete.
Supply and fix bell push flush type 5 Amps 230 Volts single pole complete all as specified.
Supply and fix Socket outlet multipurpose having provision for 3 pin, 230 Volts 15/16 Amp and 3 pin, 5/6 Amp, piano flush type complete all as specified.
Supply and fix Switch piano; flush type, single pole, one way, 230 Volts 15/16 Amps IS: 3854 complete all as specified
Supply and fix calling bell ding dong type AC 230 Volt single pole complete all as specified.
Supply and fix in repair step type regulator socket type double module 5 step for ceiling fan 1200/1400 mm size 230 volts, 6 Amps 120 watts .
Supply and fix Ceiling rose, Three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified
Supply and fix Lamp holder polycarbonate insulated body, with back plate suitable for batton fitting complete all as specified.
Supply and fix moduler switch in repair piano flush, button type 6 Amp SP one module one way complete all as specified
Supply and fix moduler switch piano in repair flush, button type 6 Amp SP one module two way complete all as specified
Supply and fix moduler switch piano in repair flush button type 16/ 20 Amps SP one module one way complete all as specified.
Supply and fix moduler socket outlet in repair multipurpose 2/3 Pin 6 Amp two module complete all as specified & directed.
Supply and fix moduler socket outlet in repair two in one three pin 6 Amp and 16 Amp two module flush type complete al as specified.
Supply and fix moduler bell push in repair 6 Amp one module one way complete all as specified.
Supply and fix 4 step modular electronic fan regulator in repair ,120 watt ,flush type 2 module.
Supply and fix in replacement of rusted GI sunken box with flush metal GI box 1 module suitable for modular switches incl plastering, making good disturbed surfaces of wall, painting as per existing to match the wall complete all as directed.
Supply and fix in replacement of rusted GI sunken box with flush metal GI box 2 module suitable for modular switches incl plastering, making good disturbed surfaces of wall, painting as per existing to match the wall complete all as directed.
All as per item no 24 here-in-before but 3 module complete all as specified.
All as per item no 24 here-in-before but 4 module complete all as specified.
All as per item no 24 here-in-before but 6 module complete all as specified.
All as per item no 24 here-in-before but 8 module complete all as specified.
All as per item no 24 here-in-before but 12 module complete all as specified.
Supply and fix in repair combind cover plate white 1 module suitable for modular switches complete all as specified and directed.
Supply and fix in repair combind cover plate white 2 module suitable for modular switches complete all as specified and directed.
Supply and fix in repair combind cover plate white 3 module suitable for modular switch/socket complete all as specified and directed.
Supply and fix in repair combind cover plate white 4 module suitable for modular switch/socket complete all as specified and directed.
Supply and fix in repair combind cover plate white 6 module suitable for modular switch/socket complete all as specified and directed.
Supply and fix in repair combind cover plate white 8 module suitable for modular switch/socket complete all as specified and directed.
Supply and fix in repair combind cover plate white 12 module suitable for modular switch/socket complete all as specified and directed.
Supply and fix in replacement of energy saving ,surface mounted, LED 10 watt Bulk head luminaire with decorative oval diffuser comprrising of high brightness LEDs complete all as specified and directed by Engr-in-charge.
Removing /Refixing of LED tube light fittings / LED fency fittings of any make or capacity carefully complete all as specified and directed by Engineer-in-charge. ( taken down under Item No 1)
Supply and fix mirror light decorative compact luminarious with decorative ends caps 10Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size all as specified and directed
Supply and fix Decorative Gate light made up of high grade unbreakable polycarbonate materials incl LED Lamp B22 base up to 1nox20 W LED lamp ,mounting pole dia -60mm(Max) OD incl fixing arrangements all as specified & directed by Engr-in-Charge.
Supply and fix wall mounted LED tube light fitting 1x20 watts polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed.
Supply and fix in replacement of LED tube rod 20/22 Watt sigle or double side connectors polycarbonate complete incl making connections,alteration in existing tobe light fittings complete all as specified and directed
Supply and fix in replacement of Decorative wall light fixture made up of cast aluminium body polycarbonate diffuser, with 9- 15 Watts LED Lamp complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement of Surface mounted general purpose square shaped luminare with low height CRCA housing and high transmitivity diffuser suitable for office application,LED 32 watt,6500K in White & gray housing with profiled & flat diffuser all as specified and directed by Engineer-in-charge
Supply and fix in replacement of fully diffused recessed mounted 2'x2' LED luminaire with UGR<19, for Full Glow Office Complaint indoor spaces, LED 36 Watt ,6500K in White & gray housing with profiled & flat diffuser all as specified and directed by Engineer-in-charge.
Supply & Fix Industrial lighting ,70 Watt with Eco well glass in PDC housing with luminaire efficiency of 110 Lm/W, Superior tampered fin design with fin design with exceptional thermal management , ingress protection of IP 66 complete all as specified and directed
Supply and fix LED tube 18 watt 4 pin rod suitable to fix in existing 2"x2" fitting made out of diffused glass lumen out put 1800 lumens incl making necessary alteration /connection in existing fitting for fixing for fixing of same complete all as specified & directed
Supply and fix Indudtrial type LED tube light fitting box type fitting (1200x300) CRCA body with poly carbonate deffuser all in one single phase 36 watts prewired all as specified & directed accessories complete all
Supply and fix in repair round shaped LED downlights ,made with injection moulded polycarbonate/aluminium spun ring for surface mounting of capacity 12 Watt with all accessories and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified.
Supply and fixing in replacement for Distribution Box MCB Protected Socket with sheet steel enclosure 20 A MCB DBOXX Combo DP including PLUG TOP all as specified & directed.
Supply and fixing in replacement of Busbar chamber of size 600x315x214 mm or higher size with PVC hinged lid suitable for and mounting arrangement for fixing of MCCB 4 pole, 100/125 Amps 25 KA (Icu=100%Ics) 415 Volt,50 Hz, duly connected with and incl 04 Nos of copper Busbar 300 Amps fixed on epoxy insulators, Gun metal cable gland of 25 Sqmm 01 No and PVC coupler for sub main wires 04 Nos complete Polycarbonate type (shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, having high impact, made of halogen and silica free recyclable material), UV resistant, having high grade gasket made of Polyurethane, flame retardant,complete all as directed at site by Engr in charge or his rep complete. Note:- Only MCCB shall be measured and paid for seperately all other items incl connection from MCCB to busbar with suitable size copper wire incl thimble, bottle lugs etc are incl in item rate.
Supply and fix in replacement of Meter Distribution board made out of polycarbonate of size 600x600x170 mm (dust proof & weather proof ,Shock proof, rust proof ,corrosion free ) with 230 V Ac 50 HZ 3 Wire , Gasket shall be embedded with T-locking arrangement and suitable for mounting of Electronic Meter -04/6 Nos with provision of clear transparent glass of as per meter installed incuding electrical connection with existing system and sealing properly & taking out u/s broken/rusted box of any size and type complete and making disturbed surface as per existing one all as specified and directed.
Removing & Refixing as its existing position or new location the Electronic Meter carefully including electric connection with marker of qtr nos on E/M complete all as specified & directed
Supply and fix Temper proof LCD display Digital Energy Meter,single phase, 2 Wire,AC, 230V, Cap 10-60A, Push to fixed type Box with marker of qtr nos on EM as directed by Engr-in-chargeMake : Secure, L&T,HPL
Supply and fixing in replacement for Distribution board SPN 8 Way double door, for mounting MCBs isolator, ELCBs etc factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar. DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and baked at high temperature, painted in seven tank process. The DBs shall be of IP 43 protection.Note:- DB and MCCB/MCB shall be of same make
Supply and fixing in replacement for Distribution board SPN 4 Way double door, for mounting MCBs isolator, ELCBs etc factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar. DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and baked at high temperature, painted in seven tank process. The DBs shall be of IP 43 protection.Note:- DB and MCCB/MCB shall be of same make
Supply and fixing in replacement for Distribution board Vertical type TPN 4 Way double door, suitable for MCCB 100 to160 Amps MCCB as incoming and MCBs for outgoing factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar. DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and baked at high temperature, painted in seven tank process. The DBs shall be of IP 43 protection incl taking out old u/s complete. Note:- DB and MCCB/MCB shall be of same make and paid separetaly
Supply and fix in repairs MCCB 100 Amps FP 415 Volts having breaking capacity 16 KA with and incl spreader link kit complete suitable for fixing as incoming in polycarbonate busbar complete all as specified and directed.
Supply and fix in repairs MCB single pole 240 volt, 10 KA, 5-32 Amp, 'B' series confirming to IS complete all as specified and directed.
Supply and fix in repairs MCB SPN 240 Volt 10 KA 20 to 32 Amp 'B' series conforming to IS complete all as specified & directed.
Supply and fix in repairs MCB SP 240 Volt 10 KA 40 Amp 'B' series conforming to IS complete all as specified & directed.
Supply and fix in repairs MCB 415 Volt, TPN, 10 KA 40- 63 Amp 'B' series conforming to IS complete all as specified & directed.
Supply and fixing in replacement for Distribution Box MCB Protected Socket with sheet steel enclosure 20 A MCB DBOXX Combo DP including PLUG TOP all as specified & directed
Material and labour for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sqmm (nominal area) drawing in and including 20 mm dia or higher medium duty PVC concealed conduit/flexible conduit where reqd and conduit accessories and fittings. Including one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 4 Sq mm as earth wire upto common earth and connected to earth dolly complete incl taking out old unserviceable submain all as specified & directed.
Material and labour for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sqmm (nominal area) drawing into existing conduit including one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 4 Sq mm as earth wire upto common earth and connected to earth dolly complete incl taking out old unserviceable submain all as specified & directed.
Material and labour for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sqmm (nominal area) drawing in and including 25 mm dia or higher medium duty PVC concealed conduit/flexible conduit where reqd and conduit accessories and fittings. Including one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 6 Sq mm as earth wire upto common earth and connected to earth dolly complete incl taking out old unserviceable submain wiring all as specified & directed.
Material and labour for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sqmm (nominal area) drawing into existing conduit including one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 6 Sq mm as earth wire upto common earth and connected to earth dolly complete incl taking out old unserviceable submain all as specified & directed.
Material and labour for sub main wiring with 3 Single core(R,Y,B Phase) PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sqmm (nominal area) drawing in including 25mm or higher medium duty PVC concealed conduit/flexible conduit where reqd & all conduit accessories and fitting inclu one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 6 Sq mm as earth wire upto common earth and connected to earth dolly complete incl taking out old unserviceable submain all as specified & directed.Note : 4 RUN Cable will be drawn in one conduit , measured per RM only.
Supply & Laying XLPE insulated armoured heavy duty electric cable , with multi stranded aluminium conductor served with an inner sheathing of PVC type armoured with galvanized steel wire or tape and PVC sheathed 1100 volt grade,nominal cross sectional area 16 Sqmm 4.0 core inclu lugs and heat shrinkable PVC Sleeves on exposed surfaces & teflon tape duly insulated complete laid in trenches, ducts, drawn through pipe across the road/path/alongpoles/wall/floors/equipment etc including jointing and testing complete all as specified and directed by the Engr-in-charge.
Supply & Laying XLPE insulated armoured heavy duty electric cable , with multi stranded aluminium conductor served with an inner sheathing of PVC type armoured with galvanized steel wire or tape and PVC sheathed 1100 volt grade,nominal cross sectional area 10 Sqmm 2 core inclu lugs and heat shrinkable PVC Sleeves on exposed surfaces & teflon tape duly insulated complete laid in trenches, ducts, drawn through pipe across the road/path/alongpoles/wall/floors/equipment etc including jointing and testing complete all as specified and directed by the Engr-in-charge.
Excavation in trenches not exceeding 1.5m and not exceeding 1.5 m in depth for laying of electric cableand getting out in soft/loose soil, complete all as specified and directed by Engr -in-charge
Returning, filling in excavated soil , including leveling,watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr -in-charge
Removing excavated material(soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above & starting point complete all as specified and directed by Engr-in-charge.
Material and labour for sand cushioning in trenches for protection of UG cable with river based sand laid dry in trenches before and after laying of cable, incl well ramming complete all as specified and directed
Material and labour for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified & directed.
Supply & Laying in replacement of GI Steel tubing light grade 40 mm(2") dia including all fitting laying in trenches across road or grouting /fixing on wall for protection of cable complete all as specified and directed by Engr-in-charge.
Supply & Fixing building security light fitting LED type 45 Watt of dia-cast IP 66 aluminium housing, 45 Watt, LED 6000K lence type toughened glass having seprate surge protector 10 KV , efficiecy of minimum 100 lumens /watt, incu adobter if any , prewired complete incuding 40/32 dia GI Light grade for bracket of fitting as reqd up to 1.2 RM proper shaped , bended (120 degree) threaded & drilling holes for wire entry & MS clamps made out of flat iron of suitable size incl painting all as specified & directed
Repair to Electric meter box by fixing of box cover with welding or replacement of damaged hinges ,replacement of broken/disappear glass by replacement of clear transparent glass of suitable size and fixing with proper manner and reparing/changing of cover fixing arrangement as per existing one including painting with two coat of supper enamelled paint over one coat of primer after cleaning dust,oil ,grease etc by scrapping of outside &inside of meter box of size 75x60x20 cm all as specified and directed
Repair to Electric meter box by fixing of box cover with welding or replacement of damaged hinges ,replacement of broken/disappear glass by replacement of clear transparent glass of suitable size and fixing with proper manner and reparing/changing of cover fixing arrangement as per existing one including painting with two coat of supper enamelled paint over one coat of primer after cleaning dust,oil ,grease etc by scrapping of outside &inside of meter box of size 120x100x20 cm all as specified and directed
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized wire 4 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 15 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSR part 1 including testing on completion all as specified and directed. incl demolition to existing one complete. Note: (i) Earthing has to done by spl persons and if the desired earth resistance is not found within permissible limit shall be redone by contractor at no extra cost. (ii) Cost of GI wire 4 sqmm and 15 mm dia pipe medium grade upto 7.5 mtr is included in the rate quoted for this item
Material and labour for replacement of unserviceable earthing with Copper electrode chemical advance maintenancefree chemical gel earthing electrode 50mm dia thick buried directly in ground vertically to a depth not less than 2.10 mtr below ground level filled with highly conductive metalic compound mixture CCM with the permanent sealing of the both end, outer dia pipe 50mm with strip terminal 50x6 with terminal holes incl one bag 25 kg of bfc compound, earth connected with earth lead copper wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board protected by galvanized iron pipe medium 15 mm bore, PVC chamber as per manufacturer instruction and testing on completion. Note: (i) Earthing has to done by CPRI approved firm and if the desired earth resistance is not found within permissible limit shall be redone by contractor at no extra cost. (ii) Cost of Copper wire 4 sqmm and 15 mm dia pipe medium grade upto 7.5 mtr is included in the rate quoted for this item
Supply and fix Copper strip 20x3.15 mm burried in ground & wall with saddles and fixing screws incl connected earthing to testing point all as specified & directed
PARADISE INFRA POWER COMPANY
Alankar Traders
SRI GANESH ENTERPRISES
M/S Ex Soldiers Mechanical Works
DOON DIESEL SALES AND SERVICE
Mahamaya Engineers Services
Tarachand gurudutt
M/S J J ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .