Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-AOC D 89 SHASTRI NAGAR MEERUT UTTAR PRADESH PIN 250004 | MEERUT | UTTAR PRADESH | 250004 | L1 | Accepted-AOC AOC accepted. | |
| 2 | L2₹40.4 L+₹2.9 L (7.83%)Rejected-AOC H NO 3927 SHAH COLONY SECTOR 8 NEAR NHPC COLONY SAILI ROAD TEHSIL DISTT PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-AOC AOC rejected. | |
| 3 | L3₹42.2 L+₹4.7 L (12.7%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC AOC rejected. | |
| 4 | L4₹42.4 L+₹5.0 L (13.2%)Rejected-AOC 67 PATEL NAGAR NEW MANDI MUZAFFARNAGAR INDEX NO C 630 HQ CE WC | L4 | Rejected-AOC AOC rejected. | |
| 5 | L5₹44.1 L+₹6.6 L (17.6%)Rejected-AOC | L5 | Rejected-AOC AOC rejected. |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
20 Jul 2022, 6:00 pmClosed
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Spl repair to officer married accomodation and provision of fencing around Bldg No P-08 (Bunglow) at Birpur under AGE B/R-II of GE Dehradun.
2022_MES_531475_1
8476/A/E8
Open Tender
Civil Works
Item Rate
180 days
GE Dehradun
Class D cat a (i)
8 documents required · 8 mandatory
₹500
GE Dehradun
₹94,000
Yes
11 Oct 2022
16 Jun 2022
22 Jul 2022
16 Jun 2022
20 Jul 2022
30 Jun 2022
Amount
Dismantling asbestos cement (corugated or semicorrugated etc) sheets, in roof covering including ridge etc complete all as specified.
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to walls etc fixed with self tapping screws complete all as specified.
S&F pre-painted galvalume aluminium Zinc coating GI based plain steel sheet to match with profile sheet in 0.50mm thick of an approved of an colour having tensile strenth of 550 Mpa as in ridge,vally/gutter of roof , fixed with self tapping screws complete all as specified.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets any thickness incl cover fillets complete all as specified.
Supply & fixing tiled false ceiling of Everest Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips or 2 mm dia GI wire spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm, all 'T'' sections shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, all complete at all heights as per direction of Engineer-in-Charge.
M&L for false ceiling made out of E-board classic of size 600x600x4mm thick, GI frame consisting of main Tee of size 38.50x24.00 mm and cross Tee of size 28.50x24.00mm thick made out of PGI sheet 0.30mm thick doubled at web and single at flange, flange covered with powder coated sheet 0.25mm thick and angle 24.00x24.00x0.4mm thick powder coated suspended with GI wire 2mm dia and up to 2mtr long complete including pluging fixing of angle to brick walls with steel rawl plugs @450mm c/c and aplying two coats of oil bound distemper to the ceiling board complete all as specified and directed by Engr-in-Charge.
Dismantling timber scantlings 40 sq. cm and over in section, in any position, framed or unframed work complete all as specified.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and ditected.
S & F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, etc. conforming FE-290 (Gde E-165) complete all as specified.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concretebut excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and ditected.
M&L for brick work with subclass 'B' bricks, old size straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and ditected.
Taking down cement plastering of any description on brick/stone/concrete wall surfaces of any description incl racking out joints hacking for key,scrubbing down with water etc. complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished surfaces even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 finished surfaces even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M&L for new plastered surface of walls including corners and applying two coats of distemper oil emulsion over applying of 1-1.5 mm thick wall care putty finish wall surface even & smooth by roller including preparation complete all as specified and directed.
M&L for complete removal of existing treatment of walls incl corners and applying two coats of distemper oil emulsion over applying of 1-1.5 mm thick wall care putty finish wall surface even & smooth by roller including preparation complete all as specified and directed.
M&L for two coats of exterior grade 1st quality weather coat paints over a coat of alkaliresistant priming paint on putty surfaces complete all as specified and directed.
M&L complete removal of existing treatment from painted surfaces of external wall with scrapping, wire brushing, washing with water including preparation of old surfaces and applying wall two coats of exterior grade 1st quality weather coat paints over a coat of alkaliresistant priming paint complete all as specified and directed.
M&L for two coat of synthetic enamel paint over a coat of red oxide primer including preparation on new steel surfaces of any description over 10 cm width or girth complete all as specified.
M&L for preparation of old Steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as spd and directed
M&L for preparation of new wooden surfaces of any description over 10 cm width/girth and applying two coat of synthetic enamel paint of any description, over a coat of pink primer, complete all as specified and directed.
M&L for preparation of old painted surfaces of wood of any description over 10 cm width/girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement motor bedding (But not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified.
M&L for Vitrified Ceramic tiles Dark shade /double charged 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc.over and including screed bed 15 mm thick in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile complete all as specified
All as per item No 24 here -in- above but as in skirting etc including 10 mm thick rendering in cement mortar 1:4, complete all as specified.
M&L non-skid / mat finish designed coloured joint free ceramic tiles of size not less than 400 mm x 400 mm x 6- 7 mm thick in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:6 complete all as specified.
M&L for coloured Glazed ceramic tiles in vertical surfaces of size 350mm x 250mm x 7mm/ 450x 350 x 7mm thick over and including 10 mm thick bedding layer in CM 1:4 , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as directed.
Demolition of Stone slabs and tiles laid, bedded and jointed in any mortar of any description or thickness in floors, aprons etc complete all as specified. .
M&L for granite stone 18 to 20 mm thick glazed (table rubbed and polished) fixed as in plateform and the like set in cement mortar 1:4 and pointed with white cement (1:2) using marble dust with admixture of pigment to match and exposed edges rounded with and including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement and including demolition of existing old cement concrete complete all as specified.
M&L for Cement concrete type D2 1:4:8 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M&L for durastone heavy duty coloured parking tiles 300mmx300mm x 9-10mm thick exterior grade set and jointed with neat cement slurry and pointed in coloured or white cement to match over and including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 complete all as specified.
M&L for pre-polished pavement coloured chequred tiles glossy finish of size not less than 300mm x 300mm x 20-22mm thick with anti skid properties laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
Taking down chowkat with shutter of any description n. exc 1.5 Sqm each without taking off shutter from frames complete all as specified and as directed by Engr-in-Charge.
Taking down chowkat with shutter of any description exc 1.5 Sqm but n.exc 4 Sqm each without taking off shutter from frames complete all as specified and as directed by Engr-in-Charge.
Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each and refixing in same opening after necesssary repair complete all as specified.
Taking down shutter of any description n.exc 1.00 sqm each complete all as specified.
M&L for Second class hard wood plain solid straight chowkats and frames wrought, framed, rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix flush shutters 30 mm thick one face is covered with decorative face veneer teak wood finished with lipping/frame to match , solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S & F 30 mm thick second class hardwood glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge complete all as specified in SSR Pt I-2009 section 8 clause 8.24 (a) and as directed.
S & F 30 mm thick second class hardwood glazed and Skelton factory made window/ventilator shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass / gauge complete all as specified in SSR Pt I-2009 section 8 clause 8.24(b) and as directed
S&F factory made steel windows with side hung shutters including box type hinges with MS handles and tower bolts complete with glazing bars dovetailed or welded with one shop coat of primer complete all as specified and directed.
S&F factory made steel windows with side hung shutters including box type hinges with MS handles and tower bolts complete without glazing bars, as fly proof shutters with one shop coat of primer complete all as specified and directed.
S & F PVC solid factory made door frame of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified.
S & F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as shown in SSR Part – II 2010 and as directed by Engineer-in-Charge.
S&F mild steel flat iron for hold fasts and similar articles conforming to Fe-290 Gde E-165 complete all as specified and ditected.
M&L cutting holes in brick wall built in cement mortar exc half brick but n.exc one brick for inserting or cement concrete 1:2:4 hold fast etc and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified. .
S&F 200 mm long, solid in one piece stainless steel barrel tower bolts Gde 202 complete all as specified and directed by Engr-in-charge.
S&F 150 mm long, solid in one piece stainless steel barrel tower bolts Gde 202 complete all as specified and directed.
S&F 150mm size solid in one piece stainless steel handles,Gde 202 D type, fixed with stainless steel screws complete all as directed complete all as specified and directed by Engr-in-Charge.
S&F 125mm size solid in one piece stainless steel handles,Gde 202 D type, fixed with stainless steel screws complete all as directed complete all as specified and directed by Engr-in-Charge.
S&F 100 mm size stainless steel butt hinges Gde 202 and fixed with stainless steel screws, complete all as specified and directed by Engr-in-Charge.
S&F 75 mm size MS butt hinges medium weight cold rolled fixed/ welded to frame complete all as directed.
S&F stainless steel sliding door bolts 204 grade, hasp and staple type with bright bolt not less than 12mm dia with and incl a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate 250mm long complete all as specified and ditected.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples with 8% nickle complete all as specified and ditected.
Hacking out old broken glass ( any thickness , size, quality, or description) from wooden frame glazed with putty or fixed with beads all as specified and directed
M & L sheet glass ordinary quality 4mm thick and glazing with oil putty or fixed with bead/ glazing pins in squares n.exc. .5 sqm each pane all corner of glass to be fixed with silicon complete all as specified and directed.
S&F in repair WPC board 18-19mm thick, one side laminated, medium density, flat pressed, single layer type or three layer type, BWR grade for Almerah doors, self, kitchen cabinet etc complete all as specified.
S&F stainless steel CP semi hydraulic albehari hinges all as sample approved by Engr-in-Charge
S&F magnet catcher for cub board with brass body and striking plate including letting in and fixed complete all as specified and directed.
S&F in repair peg set of five stainless steel fixed on CP steel plate 304 grade including fixing screw as per approved sample complete all as specified.
S&F in repairs glass corner shelf suitable size made of 5mm thick toughned glass complete all as specified,.
S&F in repair 25 mm dia stainless steel polished 204 grade drapery rod 1mm thick with final decorative, including brackets, decorative finished at both ends complete all as speccified and directed as per approved sample.
S & F Solid PVC wall Lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing incl removing existing unserviceable wall linning complete all as specified.
S&F in repairs CP brass Soap dish 6 inches complete all as specified and directed.
S&F in repair PVC Shelves 450mm of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105 gms) complete all as specified.
S&F in repair plate rack of size 100 cm x 80 cm x 300 mm made out of 1.00 mm thick stainless steel complete all as specified and as directed.
S&F in repairs stainless steel kitchen sinks with draining board ISI marked made of stainless steel 1 mm thick, with plugs, washers and wastes, including bedding lime cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified.
Demolition of reinforced cement concrete as in shelves, chajjas, slabs and similar work carefully and matching to adjoining disturbed surfaces complete all as directed.
M&L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and colums, in floors, roofs, landing balconies, canopies, deck slabs, chajja and in shelves and the like, complete all as specified and directed. Note : (i) The work will be carried out upto tripple storey builing (ii) The rate for scafolding is included in the quoted rate for item.
M&L for use and waste form work to soffits of suspended slab such as roof slabs, floor slabs, landing and similar works, not exceeding 200mm thick for fair finished surfaces of concrete complete all as specified and directed.
M&L for use and waste form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs, sides of RCC/PCC bands in walls, horizontal or sloping and similar works exc 10 cm but not exc. 20 cm wide for fair finished surfaces of concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in cills, copings, benching on chajjas, roof kerbs, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed.
S&F TMT MS bar 8 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia as complete all as specified.
S&F MS framed work such as grills,gratings,etc., with ends of bars shoulderedor riveted, or forged into spikes; framed guard bars;barred iron doors and similar work conforming to Fe 210,Gde E-165 complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair mild steel, plain, black sheet 1.60 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified.
S & F Acrylic PVC sheets 2-3 mm thick fixed with screw and washer in gate , wall etc complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing and connections including cleaning for refixing with all fittings for 15 mm bore GI tubing complete all as specified
Taking up or down steel tubing and connections including cleaning for refixing with all fittings for 20 mm bore GI tubing complete all as specified .
M&L cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting not exc 20cm girth complete all as specified .
Supply, fixing, laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Supply, fixing, laying & testing 20 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F in replacement rotational moulded polyethylene 500 Ltrs Capacity water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I including ball brass valve, with polythelene float three layer external and internal white and fly nut complete screwed down for iron pipe of 20 mm dia complete all as specified and ditected.
S&F in repair ball valve high pressure of PTMT with epoxy coated alum rod & high density plastic ball screwed for 15mm bore iron pipe and fixed ( minimum weight 20mm -210 gms) complete all as specified and directed.
S&F in repair CP toilet paper holder as approved by Engr-in-Charge complete all as specified .
S&F in repair CP brass wall mixer with provision of over head shower complete with 115mm long bend pipe complete all as specified.
S&F in repair CP brass wall mixer 3-in-1 system with provision of over head shower and telephonic shower complete with 115mm long bend pipe, complete all as specified.
S&F in repair 15 mm dia chromium plated brass central hole wash basin mixer (pillar tap) with accessories in wash basins for mixing hot and cold water, screwed down for 15 mm bore GI pipe complete all as specified and directed.
S&F in repair CP brass bib tap fancy type short body15mm bore screwed for iron pipe or for brass ferrule complete all as specified.
S&F in repair 15mm bore Bib taps long body, cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair 15 mm bore Angle cock/stop valves (2 in 1), cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified.
S&F in repair PVC Health Faucet with 1 mtr metalic Expandable tube & hook complete all as specified.
S&F in repair 20 mm dia brass chromium plated tubular towel rail, D type, 60 cm long between flanges fixed with rawl plug complete all as specified and directed.
S&F in repair brass chromium plated ovehead shower with shower arm complete all as specified and directed.
S&F in repairs vitreous china water closet (Padestal pattern) fancy type including fixing bolts, flushing cistern dual flush type of capacity 10 ltr incl PVC white Seat cover and incl lime concrete bedding including 100mm CI 'P' or 'S' trap complete all as directed.
S&F in repair 40mm outer dia of CPVC pipe class 1 on wall /ceiling or laying in floor incl of all fitting i.e elbow,tee and socket etc, complete all as specified.
S&F in repair vitreous china, white, oval shape wash hand basin, flat size 550 x 400 mm including MS brackets including 12 to 15mm thick prepolished mirror granite fixed on RCC slab 1:11/2:3, 50mm thick with steel reinforcement (paid separately) cutting for and pinning in ends of brackets but excluding Waste pipe & with 32mm (PTMT) waste coupling (half or full threaded) minimum weight 32gm-45gms) & 15mm bore CP pillar tap supply only 25mm dia PVC (LDPE) of pressure 6Kg/cm2 down pipe 75cm long complete all as specified and directed.
S&F in repair PVC connection 15mm size with PTMT nuts, of 450 mm length complete all as specified .
Taking down AC/Salt glazed ware /PVC pipes and fittings upto 110mm complete all as specified .
S&F in repairs for 100mm bore dia pipe Stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof complete all as specified and directed.
S&F PVC (SWR) pipes of 110 mm dia, single socketed fixed to walls complete all as specified and directed.
S&F PVC (SWR) pipes of 75 mm dia, single socketed fixed to walls complete all as specified and directed.
S&F PVC (SWR) bends of 110 mm dia, any radius complete all as specified and directed.
S&F PVC (SWR) bends of 75 mm dia, any radius complete all as specified and directed.
S&F PVC (SWR) junction single Tee equal or unequal 110 mm dia complete all as specified and directed.
S&F PV C (SWR) junction single Tee equal or unequal 75 mm dia complete all as specified and directed.
PVC (SWR) floor trap, plain with grating including jointed with solvent cement of 75 mm outlet dia complete all as specified and directed.
S&F in repairs PVC waste pipe not less than 60cm long with PVC coupler for kitchen sink, WHB, urinal, etc complete all as specified and directed.
S&F in repair stainless steel sink coupling with waste pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair CP steel Grating round with steel frame with hinge 100mm dia all as per sample approved by Engr-in-charge.
S&F in repairs fancy type 5.50mm thick looking mirror with PVC moulding 40mm wide all around with back 5mm thick PVC board of size 450x600mm complete all as specified and directed.
Excavation in post holes (or similar holes) in any type of soil each n.exc 0.50 cum getting out and removing surplus soil to a distance n.exc 50m and making good the disturbed surface complete all as specified.
M&L Cement concrete 1:2:4 type B2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed by the Engr-in-Charge.
S & F of mild steel work as in, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe – 290 Gde E -165 complete all as specified and directed.
Fixing only Chain link MS galvanised fencing of n exc. 4.0 kg per sqm plain GI wire any type mash size of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
Supply only chain link MS galvanised fencing any size or type complete all as specified and directed.
S & F of mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other or screwed both ends, each screwed ends to be fitted with washer and one hexagonal or square nut, exc. 5 cm and not exc. 10 cm long dia of neck 11 to 15 mm, complete all as specified and directed.
S&F mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 as directed by Engineer-in-charge.
M&L for Machine pressed precast concrete interlocking paver block with grey cement and no pigment of any shape and size confirming to IS 15658-2006 of 60 mm thickness, M 35 Grade laid over 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
S&F 3 mm thick ACP (Aluminium composite material) fixed with screw on existing mild steel frame complete all as specified and directed.
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator etc and removing from site and making good disturbed surfaces of walls/floors etc complete all as specified and directed by Eng-in-charge.
M&L for Point wiring with1100 Volts, grade 1.5 Sqmm. (nominal area) ,PVC insulated but unsheathed multistranded copper conductor single core FRLS cable drawn through and including non metallic medium duty rigid PVC concealed conduit (medium duty) 20mm dia or higher size complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc CI pressed terminal box with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly including cutting chases for conduits and making good to walls,floors etc as per existing one complete all as specified and directed by Engr.-in-charge one light/ fan point control by one way switch. Note :(1) The wiring to be done as per IE rule and maintain colour code accordingly. (2) Moduler combined cover plates with frame shall be paid separetely under respective items.
One light point/ ceiling fan point/ Exhaust fan point controlled with one-one way switch.
One bell point controlled with one-one way switch.
One three pin 5 Amp socket on same board with other switches.
One three pin 5 Amp socket on independent board.
All as per item No 122 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, and earth continuity coductor of size 2.5 Sq mm complete all as specified.
All as per item No 122 above but up to Sheet matel enclosure MCB DB with plug socket independent, with cable 4 Sq mm size, with earth continuity coductor of size 4 Sq mm complete all as specified .
S&F modular switch 1 way 6A,1 module,230 volts complete all as specified and directed.
S&F modular switch 1 way 16A,1 module, 230 volts complete all as specified and directed.
S&F modular socket 6A-2/3 pin, 2 module, 230 volts complete all as specified and directed.
S&F modular socket combination 6/16 A,6 pin,2 module ,230 volts complete all as specified and directed.
S&F modular Fan step regulator, 120W,2 module ,230 volts complete all as specified and directed.
S&F Modular Bell push 6A 1 module complete all as specified and directed.
S&F Bell Multi Music type complete all as specified and directed.
S&F modular white cover plate with frame,1 module ,230 volts complete all as specified and directed.
S&F modular white cover plate with frame,2 module ,230 volts complete all as specified and directed.
S&F modular white cover plate with frame,3 module ,230 volts complete all as specified and directed.
S&F modular white cover plate with frame,4 module ,230 volts complete all as specified and directed.
S&F modular white cover plate with frame,6 module ,230 volts complete all as specified and directed.
S&F modular white cover plate with frame, 8 module ,230 volts complete all as specified and directed.
S&F in replacement of sheet metal enclosure SPN with 3 pin earth metal plug and socket complete with one SPN MCB 20 Amps, 240 volts in repairs complete all as specified and directed by Engineer-in-Charge. Make L&T, ABB, Legrand, GE
S&F ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 250 V AC complete all as specified.
M&L lamp holder insulated body with back plate suitable for angle and batten fitting complete all as specified.
S&F in replacement of U/S Tamper Proof electronic single phase whole current energy meter (LCD Display) 10 Amp to 60 Amp, 240 volt class 1.03 and class 2.05 AC supply including cable connection, proper sealing with lead. The meter shall comply with the latest version of IS-13779 with atleast 2 anti tamper LED indication of line load reversal and earth loading indication including electrical connection with existing system and sealing properly including push fit type pvc box complete. The meter shall work satisfactory with guarantee accuracy as per limit of IS-13779. The meter shall be fixed on existing steel boxes on wall complete all as specified and directed. (Note: Old U/S Meter shall be deposited to E/M store yard). Make:- L&T/ Legrand/Secure/BHEL.
M&L in replacement sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC concealed conduit heavy duty accessories and fittings. PVC insulated unsheathed FRLS cable copper conductor multistranded of size 6 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
S&F in replacement sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 8 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and 06 MCB SP as out going complete all as specified and directed . Make Legrand/Schneider/ABB..
S&F in replacement sheet metal enclosures Triple pole and neutral double door 415 Volt 4 way DBs IP-43 IK- 09 Vertical type suitable for 200 Ams rated bus bar & one MCCB 100 Amp as incoming and 12 MCB SP as outgoing complete all as specified and directed . Make - Legrand/Schneider/ABB.
S&F MCB double pole 240 Volt 10 KA 40 Amp 'B' series conforming to ISI marked complete all as specified & directed.
S&F MCB single pole and 240 volt 10 KA 5-32 Amp 'B' series conforming to ISI marked all as specified and directed.
S&F MCCB 415 Volt 16 KA 4 pole 125 Amp magnetic trip release & setting as incoming with fixing arrangement complete all as specified and directed.
S&F in replacement wall mounted tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make: Philips cat part No TMC 501P1xT LED 22WP-3241(Tube Batten) and MAS LE$D 1200mm 18W-865-T-81 (Tube) / Wipro Cat part No WI0922208 (Tube Batten) LL13-181-65SE (Tube)/ Havells Cat Part No LUMILINEPLUSBS20WLED865SPCSS (Tube Batten)CRYSTAL1213T8DSTL20WLED865SGLASS(TUBE DOUBLE SIDE) or equivalent in Eveready
S&F in replacement mirror light decorative compact luminarious with decorative ends caps 9/10 Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size . Make Havells Cat No Edgelite or equilent in Philips/Wipro / Eveready
S&F in replacement LED light fitting WW decorative wall mounting SS brush finish fixture with frosted glass suitable for upto 1x40 watt mini glass lamp with and including one no 12 watt LED lamp. complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable sizeAs per Havells Cat Part NO LHFOAJE1TN1IO60 or equivelent of Bajaj/ Philips/ Eveready.
S & F high efficiency LED bulbs 1 X 12 watt that can be used as a ready replacement for existing GLS ad CFL direct fit in holder complete all as specified and directed.
S&F in replacement of ceiling fan 1200 mm sweep single phase 230 volts double ball bearing with down rod , canopy, blades etc BEE 5 star rated including connecting with twisted three cord flaxible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan comlete all as specified and directed .( Note: Old unserviceable ceiling fan will be deposited in E/M store yard. )
Cutting hole on the existing wall of any description round shape for fixing exhaust fan of 300mm sweep size complete with plastering the surface and matching with the existing surface complete all as specified and directed.
Supply and fix in replacement exhaust fan, steel body AC single Phase. 230V of size 300mm, 900 RPM, single phase, 230V AC with louver all as specified and directed 30 mm sheet. including connection with twisted white three core flexible copper multistranded conductor cabl from ceiling rose to connector all a directed by Engineer-in-charge. Make:- Havells cat part No. Ventil Air DXWHT, CG cat No. BRISKAIR or equivalent in crompton. ( Note: Old unserviceable fan will be deposited in E/M store yard. )
S&F in replacement air ventilation fan made of sturdy Engineering plastic complete with louvers shutter, 250 mm, 1200 RPM, single phase, 230V AC including necessary, M&L for making hole fixing arrangement on wall with frame holdfastner, bolt, washer etc including connection with twisted white three core flexible copper multistranded conductor cabl from ceiling rose to connector all a directed by Engineer-in-charge. Make:- Havells cat part No. Ventil Air DXWHT, CG cat No. BRISKAIR or equivalent in Orient. (Note: old unserviveable fan shall be deposite in E/M yard).
Supply, Fixing & Connecting in replacement wall mounted fan oscillating type 400 mm sweep single phase 230 Volt complete all as specified and directed. Make :- Havells/ Crompton/ Usha ( Note: Old unserviceable Exhaust fan will be deposited in E/M store yard. )
S&F in replacement of Geyser vertical mount type 25 Ltrs capacity five star rated , shockproof and rust proof metal body compact size including two nos PVC connection heavy duty and connecting with all fixing arrangement of nuts & bolts and fixing on wall complete all as specified & directed . MAKE: BAJAJ, RECOLD,/ HAVELLS . ( Note: old unserviceable Geyser will be deposited in E/ M store yard )
M & L in replacement DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 6/10/16 sqmm 2/3.5/4 core and fixed to the Steel Poles by means of suitable size of clamps with nut and bolts and incl provn for fixing 01 nos of single pole MCBs 6-32 amps,10KA and MCB TPN 6-32 amps, 10 KA = 01 No inside the box and all as spcd and directed. Make :- Sintex / Hensel or as approved.
S&F LED decorative post top lantern for Garden light 40 watt IP 65 protection resistance to impact and corrosion glare, free and better uniformity WW version as per CG cat part No LPTO40CDL/ Bajaj model No. BGCTW4LEDWW including taking down old unserviceable post top lantern complete all as specified.
M&L GI bracket made out of 40 mm GI pipe medium grade bend for fabrication to shape as required length of pipe 1.2 mtr with necessary fixing arrangement by means of MS clamps 02 Nos not less than 50x6 mm MS flat duly painted, nuts, bolts and washer complete all as directed (Make TATA/JINDAL/Swastik).
Supply and Fixing Integral LED Bldg security Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 45 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours, complete all as specified and directed. Make:- Crompton model No. LSTP-45-CDL/Havells model No. ENDURAPEARLNEOSL 40WLED757PASYTOPC /Philips Cat Part No BRP409LED CW036MRFGIPSUGRand syska SSK-ST-40W including taking out old unserviceable street light complete all as specified.
M&L for Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of underground cable, foundation of pole etc and getting out in any type of soil complete all as specified and directed.
M&L for Returning, filling in excavated soil in trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
M&L for Removing of excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for laying local dry clean sand filling for cushioning in trenches around under ground cable complete all as specified and directed.
M&L for laying well burnt brick, old size in trenches, as protection of under ground cable complete all as specified and directed.
Supply and laying cable, XLPE Insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables(heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core including all bare conductor of cable duly insulated PVC Heat shrinkable sleeve 1.1 KV grade, including lugs, CP brass cable gland etc complete all as directed.
All as per Item No 167 here-in-above but 6 Sq mm, 2 core complete all as directed.
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized steel earth wire 4 mm dia by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1, cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm c/c both ways, and with one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil and necessary testing complete all as shown on electrical plate No 3 of SSR Part –I (2009) and as directed.
M/s Pradeep Kumar
M/s Anil Kumar
VERDHMAN ASSOCIATES
M/S C S AITHANI
M/s RAM RATAN AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .