Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC PSRA 146 A PULIMOOTTIL ROAD PADAMUGAL INDRA JUNCTION KAKKANAD PO KOCHI 682030 | KOCHI | ERNAKULAM | KERALA | 682030 | L1 | Accepted-AOC lowest tenderer | |
| 2 | L2₹40.5 L+₹6.2 L (18.2%)Rejected-Finance 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | L2 | Rejected-Finance other than lowest tenderer | |
| 3 | L3₹44.5 L+₹10.2 L (29.7%)Rejected-Finance | L3 | Rejected-Finance other than lowest tenderer | |
| 4 | L4₹46.5 L+₹12.2 L (35.7%)Rejected-Finance | L4 | Rejected-Finance other than lowest tenderer | |
| 5 | L5₹46.7 L+₹12.4 L (36.2%)Rejected-Finance 66 102 ARUN JYOTHI MULLASSERY CANAL ROAD ERNAKULAM KOCHI 682 011 | KOCHI | ERNAKULAM | KERALA | 682011 | L5 | Rejected-Finance other than lowest tenderer |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
21 Mar 2022, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
SPECIAL REPAIRS TO REPLACEMENT OF LT PANELS AND CONNECTED ITEMS AND EXISTING STREET LIGHT CONNECTED LT CABLES AT INS GARUDA, NAVAL BASE KOCHI
2022_MES_509885_1
8887/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
KOCHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹98,000
Yes
6 May 2022
23 Feb 2022
23 Mar 2022
23 Feb 2022
21 Mar 2022
5 Mar 2022
23 Feb 2022 - 4 Mar 2022
Amount
Supply and Lay UG cable in trenches/passing through pipes/fixed on walls or poles cable XLPE insulated, screened, PVC bedded, steel strip or wire armoured electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 300 sqmm with suitable cable gland including taking down of unserviceable Cable complete all as specified and directed.
Ditto all as per Serial Item No 1, but Cable of size 3.5 core 240 Sqmm
Ditto all as per Serial Item No 1, but Cable of size 3.5 core 185 Sqmm
Ditto all as per Serial Item No 1, but Cable of size 3.5 core 120 Sqmm
Ditto all as per Serial Item No 1, but Cable of size 3.5 core 95 Sqmm
Ditto all as per Serial Item No 1, but Cable of size 3.5 core 70 Sqmm
Ditto all as per Serial Item No 1, but Cable of size 3.5 core 50 Sqmm
Ditto all as per Serial Item No 1, but Cable of size 3.5 core 25 Sqmm
Ditto all as per Serial Item No 1, but Cable of size 4 core 16 Sqmm
Ditto all as per Serial Item No 1, but Cable of size 4 core 10 Sqmm
Supply & install, testing and commissioning in replacement of outdoor type floor mounted LT panel suitable for 415 volts, 3 Phase 4 wire, 50 Hz AC supply system conforming to IS : 8623/93, floor mounted, factory made, weather and vermin proof, fully ventilated and fabricated out of angle iron 40mm X 40mm X 6mm thick frame work and CRCA sheet 2mm thick having Aluminum bus bar of rating 600 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The size of the outer shell should not less than 1000mmX750mmX 500mm, mounted on angle iron stand made out of size 40mmX40mmX 6mm grouted of digital Volt meter & Amps meter with CTs including foundation along with painting and taking down of old existing panel complete all as specified and directed:- (a) Bus bar chamber of 3 phase and 1 neutral 4 strip 415 volts with 600 Amps aluminium strip - 1 Set. (b) MCCB 400 Amp 35 KA 4 pole - 01 No (Incoming) (c) MCCB 200 Amp 35 KA 4 pole - 01 No (Outgoing) (d) MCCB100 Amp 25 KA 4 pole - 03 Nos (Outgoing) (e) Volt meter digital 0-500 volt - 01 (f) Amp meter digital 0-300 Amp - 01 (g) Indicator lamp Yellow, Red, Blue - 01 Set
Supply & install, testing and commissioning in replacement of outdoor type floor mounted LT panel suitable for 415 volts, 3 Phase 4 wire, 50 Hz AC supply system conforming to IS : 8623/93, floor mounted, factory made, weather and vermin proof, fully ventilated and fabricated out of angle iron 40mm X 40mm X 6mm thick frame work and CRCA sheet 2mm thick having Aluminum bus bar of rating 400 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The size of the outer shell should not less than 750mm X 750mmX 500mm, mounted on angle iron stand made out of size 40mm X 40mm X 6mm grouted of digital volt meter & Amps meter with CTs including foundation along with painting and taking down of old existing panel complete all as specified and directed:- (a) Bus bar chamber of 3 phase and 1 neutral 4 strip 415 volts with 315 Amps aluminium strip - 1 Set (b) MCCB200 Amp 35 KA 4 pole - 01 No ( Incoming) (c) MCCB 63 Amp 25 KA 4 pole - 04 No (Outgoing) (d) Volt meter digital 0-500 volt - 01 (e) Amp meter digital 0-300 Amp - 01 (f) Indicator lamp Yellow, Red, Blue - 01 Set
Supply & install, testing and commissioning in replacement of outdoor type floor mounted LT panel suitable for 415 volts, 3 Phase 4 wire, 50 Hz AC supply system conforming to IS : 8623/93, floor mounted, factory made, weather and vermin proof, fully ventilated and fabricated out of angle iron 40mm X 40mm X 6mm thick frame work and CRCA sheet 2mm thick having Aluminum bus bar of rating 400 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The size of the outer shell should not less than 1000mm X 750mmX 500mm, mounted on angle iron stand made out of size 40mm X 40mm X 6mm grouted of digital volt meter & Amps meter with CTs including foundation along with painting and taking down of old existing panel complete all as specified and directed:- (a) Bus bar chamber of 3 phase and 1 neutral 4 strip 415 volts with 315 Amps aluminium strip - 1 Set (b) MCCB200 Amp 35 KA 4 pole - 01 No ( Incoming) (c) MCCB 100Amp 25 KA 4 Pole - 02 Nos (Outgoing) (d) MCCB 63 Amp 25 KA 4 pole - 03 Nos (Outgoing) (e) Volt meter digital 0-500 volt - 01 (f) Amp meter digital 0-300 Amp - 01 (g) Indicator lamp Yellow, Red, Blue - 01 Set
Supply & install indoor LT Panel made out of modular polycarbonate thermoplastic environment friendly, recyclable, UV resistant, halogen and silicon free, anti acid, anti corrosive enclosure having type test report tested at CPRI including mounting frame with following accessories suitable for incoming/ outgoing arrangements including foundation along with painting and dismantling of existing panel and shifting to MES store :- (a) MCCB 400 Amp 36 KA 4 pole with rotary handle (Adjustable thermal & Adjustable magnetic) - 01 No (b) MCCB 200 Amp 25 KA 4 pole (Adjustable thermal) with rotary handle - 02 Nos (c) MCCB 100 Amp 25 KA 4 pole (Adjustable thermal) with rotary handle - 02 Nos (d) MCCB 63 Amp 25 KA 4 pole (Adjustable thermal) with rotary handle - 01 Nos (e) Copper bus bar 600 Amp TPN -01 Set(f) LCD multi function meter - 01 Nos (g) Indicator lamp (RYB) - 03 Nos (h) CT of suitable ratio 400/5A - Set of 3 Nos Notes: Outgoing terminals for 200Amp & 100 Amp should be suitable for connecting 3.5 x 240 Sqmm Cable. External terminals may be used.
Material & Labour for straight through joint 3.5 core 300Sqmm with all accessories complete all specified and directed.
Material & Labour for straight through joint 3.5 core 185 to 240 Sqmm with all accessories complete all specified and directed.
Material & Labour for straight through joint 3.5 core 95 to 120 Sqmm with all accessories complete all specified and directed.
Material & Labour for straight through joint 3.5 core 25 to 50 Sqmm with all accessories complete all specified and directed.
Material & Labour for earthing complete with galavanised steel earth plate electrode 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of earth plate not less than 1.5 metre below the ground level, connected to galvanised iron strip 32 x 6mm as earthing lead by means of bolts, nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80mm thick RCC pit cover 320mm x 320mm of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR part -I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point/ transformer neutral/body/ LT panel etc. and testing on completion, complete all as specified & directed by Engineer-in-charge.
Taking down old unserviceable LT Panel including dismantling of cable complete all as directed by Engineer in charge.
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth for foundation of pole and laying of underground electric cable in soft/loose soil complete all specified and directed.
Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm complete all specified and directed.
Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point complete all specified and directed.
Supply and spread River Sand for cushioning and covering of UG cables in trenches complete all specified and directed. (Note : For measurement purpose only punned thickness shall be measured and paid)
Supply and laying un-reinforced precast concrete cable cover class LV type-I flat size 250mm x 150mm x 40mm complete all specified and directed.
Supply, installation, Testing and Commissioning of 9M GI Octagonal pole single section with bottom dia 155mm, top dia 70mm having sheet thickness 3mm. The door height cutout should not be more than 500mm with door elevation 500mm. The size of the reinforced rod should be 30x4mm. Size of the base plate should be 250 x 250 x 16mm with thickness of base plate 16mm(Minimum). PCD for the holes should be 260mm with foundation bolt dia M24, length of the foundation bolt 750mm with four foundation bolts .Pole should have arm to mount Single Flood light with 15-degree Arm bracket and the total height of the pole should be 9000 mm above the finished Ground level including PCC foundation, J Bolt, nuts and washers as per the drawing of Manufacturer's instructions complete all as specified and as directed.
Supply and fix 90 Watt LED Street light with pressure dia cast Aluminium housing and toughened glass with high power LED, Efficiency should be more than 110 lumen/watt, The luminaries should be of IP-66 Protection and should have 10KV external surge protection and 4KV Internal surge protection complete all as specified and directed.
Material and Labour for earthing complete with galavanised steel earth plate electrode 60cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of earth plate not less than 1.5 metre below normal ground level, connected to galvanised iron wire 4mm as earthing lead by means of bolts, nuts, washers of galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point including excavation and earth work, PCC chamber, RCC chamber cover, watering pipe, funnel etc including testing on completion.
Supply and fixing isolator TPN 415V, 50Hz of capacity 32A complete all directed.
Material & Labour wiring along with earth wire 2 x 4Sqmm + 1 x 4 Sqmm PVC insulated copper conductor single core cable in PVC conduit for connecting street light from isolator complete all directed.
Supply and fixing streetlight timer panel 3 phase, 415V, 50Hz digital 24hours with contactor 32A TP with all accessories complete all directed.
Dismantling of concrete pole any size complete all directed by Engineer in charge.
Dismantling/ taking down streetlight fitting of any size complete all directed by Engineer in charge.
Dismantling and removing UG cable of any size complete all directed by Engineer in charge.
Supply and Fix LED decorative street Lantern, with system wattage of 30 Watt, electrical class I, with a grey painted top and frame made of die casted aluminium, and a structured acrylic protector (for optimal luminous flux and IK06 impact resistance) permanently sealed onto the body to achieve separate IP 66 optical & IP 65 control gear compartments with direct access to control gear, each LED with a special lens for uniform photometric distribution. The luminaries shall have a CCT of 4000K and colour Rendering Index ≥70, a driver (efficiency ≥85%) with internal surge protection of 4/4 Kv and external surge protection of 10/10 kV 70% (L70) @ 50000hours complete all as directed.
Supply and Fix 2.05 metre height tubular pole made of hot dipped galvanized iron, having two sections, bottom section of minimum 750mm (Length) & 114mm dia and the top section with minimum of 1300mm (Length) & 76mm dia, in built junction looping box at bottom section with 32 A heavy duty 4 way connector for loop in & loop out and with MS base plate dimension of 200x 200x 12mm thickness, The pole should be given with two coats of epoxy primer and above that it should be given with polyurethane UV resistant coating, The complete system should be hot dipped Galvanised treated with average GI thickness 65mm including PCC foundation, J Bolt, nuts and washers as per the drawing of Manufacturer's instructions complete all as specified and as directed.
Material & Labour for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation, filing and mass concrete with and including necessary form work complete all as directed by Engineer In Charge.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
WELTRONENGINEERINGSERVICES
P N Enterprises
V V BHARATH ENTERPRISES
National Electric Co
M/s.Rejoy Constructions
ABM ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .