| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 CrAccepted-AOC KANNUR | KERALA | 670001 | ₹7.3 Cr Quoted ₹7.4 Cr | L1 | Accepted-AOC Contract value of L1 bidder |
| Sl No | Description | Qty | Unit | THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY L1 |
|---|---|---|---|---|
| 1.00CIVIL WORKS | ||||
| 1.01 | 2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared | 350 | sqm | 15 ₹5,250 Lowest |
| 1.02 | 2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. | 350 | sqm | 7 ₹2,450 Lowest |
| 1.03 | 2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth | 3 | each | 545 ₹1,635 Lowest |
| 1.04 | 2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil | 33.2 | cum | 191.1 ₹6,345.48 Lowest |
| 1.05 | 2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock | 205.98 | cum | 505 ₹1,04,018.89 Lowest |
| 1.06 | 2.7.2 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (requiring blasting) | 5.29 | cum | 875 ₹4,630.5 Lowest |
| 1.07 | 2.7.3 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited | 20.46 | cum | 1,466 ₹29,994.36 Lowest |
| 1.08 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | 221.68 | cum | 283 ₹62,734.59 Lowest |
| 1.09 | 2.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock | 301.38 | cum | 646 ₹1,94,693.42 Lowest |
Tender Value
₹6.4 Cr
EMD Value
₹2 L
Closing Date
31 Mar 2025, 3:00 pmClosed
Managing Director
KITCO Ltd M M Gardens, Church Landing Road Pallimukku Ernakulam
Civil ELV works of Substation and Electromechanical Works Electrical ELV Fire Protection System Elevator for Girls Hostel and Teaching Quarters at Govt Medical College Kasaragod
2025_KITCO_752530_1
RE01/HFWD/KITCO/CL/26/2024-25
Open Tender
Civil Works - Buildings
Item Rate
360 days
Kasaragod
As per NIT
7 documents required · 7 mandatory
₹11,800
Yes
₹2 L
Yes
30 Sept 2025
20 Mar 2025
2 Apr 2025
20 Mar 2025
31 Mar 2025
20 Mar 2025
20 Mar 2025 - 22 Mar 2025
Amount
CIVIL WORKS
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock
2.7.2 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (requiring blasting)
2.7.3 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
2.9.3 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (blasting prohibited)
2.10.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soilPipes, cables etc, not exceeding 80 mm dia
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
2.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
od210281/2022_2023 : Carriage of materials by mechanical transport including loading,unloading and stacking beyond 50 m initial lead up to 1km, including all lifts involved as directed by the Engineer-in-Charge.Excavated Earth/ rock.
od241520/2019_2020 : Providing and applying Antitermite treatment by injecting chemical emulsion Imidacloprid emulsiable concentrate .075% for pre-constructional treatment and creating a chemical barrier as per IS 6313 (Part II) 2001 for wall trenches, foundation, top surface of plinth filling, foundation of wall and floor, along the external perimeter of the building, etc. complete conforming to manufacturers specification and as directed by the Engineer-in-Charge. (Plinth area only to be measured for the payment )
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)
od204161/2022_2023 : Providing and applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
od186765/2022_2023 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note: - Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting, nothing extra shall be paid on this account).All work upto plinth level
od186950/2022_2023 : Providing and laying in position machine batched, machine mixed and machine vibrated design mix M-30 grade cement concrete for reinforced cement concrete using cement content as per approved design mix including pumping of concrete to site of laying but, excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportion (as per IS 9103) to accelerate,retard setting of concrete to improve workability without impairing strength and durability as per direction of Engineer-in-Charge .(Note :- Minimum Cement content considered in this item is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting)All work above plinth level upto floor V level.
od242689/2019_2020 : Providing ,hoisting and fixing upto floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, slabs,brackets etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete but excluding the cost of reinforcement with design mix cement concrete of M-25 grade conforming to IS 456 or IS 10262.
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
50.6.7.1 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
50.6.7.2 : Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
6.15 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
9.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.
9.139 : Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately.
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).
9.165.1 : Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm
od206396/2022_2023 : Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC/ Aluminium sliding window with necessary screws etc. complete.
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
10.7 : Providing and fixing ball bearing for rolling shutters.
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
10.27.1 : Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10 x 60 mm
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
od206337/2022_2023 : Providing and laying Antiskid Ceramic floor tiles 300x300x7 mm of Ist quality conforming to IS : 15622 of approved make,shade,and pattern laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.including cost and conveyance of all materials,labour charges,lead,lift etc, complete as directed by the Engineer-in-Charge at all levels.
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matchingshade complete.
11.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick
od209921/2022_2023 : Providing and laying top layer of 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.8.1 : 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix:1:3 ( 1 Cement : 3 fine sand)
13.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge.
22.23A : Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatiouswaterproofing polymer(dilution with water in the ratio of 1:1) and two coats ofcementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick inlinear meter (expansive nature) for construction joints treatment of RCC structuresuch as raft slab, retaining walls, water storage tank and at the junctions of raftslab with the retaining walls etc.. After cleaning the surface, one coat of requiredprimer for swellable water stop tape shall be applied throughout the length of thejoint @3.78 litre per 240 running meter. Over the primed surface swellable typewater stop tape shall be placed. The work shall be carried out all complete as perspecification and the direction of the engineer-in-charge. The product performanceshall carry guarantee for 10 years against any leakage.
19.16 : Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)Complete as per design
22.4.1 : Providing and Placing in position suitable PVC water stops conforming to IS : 12200 for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete:Serrated with central bulb ( 225 mm wide, 8-11 mm thick)
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.
od210284/2022_2023 : Providing and constructing soak pit 1.5 m x 1.5 m x 2 m size with honey comb brick work on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.
od210940/2022_2023 : Supplying and fixing C.I. cover with frame for manholes : 600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge
od243725/2019_2020 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.: 250 mm dia RCC pipes.
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30
16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.
16.91.1 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design& pattern.
FIRE HYDRANT AND SPRINKLER SYSTEM
od148645/2023_2024 : Supply, installation, testing and commissioning of electric driven pump set (terrace pump) suitable for automatic operation and consisting of following: complete in all respect as required and as per the technical specification. Monoblock Pump rated for 900lpm, 40 m head C.I body, bronze impeller,SS shaft with mechanical seal, volute type with suitable HP SQ cage induction motor, suitable for operation on 415V, 3phase 50Hz, AC with IP 55 class of protection for enclosure, horizontal foot mounted type with class F insulation.M.S. fabricated common base plate, foundation bolts, anti vibration pads etc. including all necessary accessories and cabling required for successful automatic operation of pump as per technical specifications.
od148098/2023_2024 : Supply, installation, testing and commissioning of electric driven pump set (terrace pump) suitable for automatic operation and consisting of following: complete in all respect as required and as per the technical specification. Monoblock Pump rated for 450lpm, 40 m head C.I body, bronze impeller,SS shaft with mechanical seal, volute type with suitable HP SQ cage induction motor, suitable for operation on 415V, 3phase 50Hz, AC with IP 55 class of protection for enclosure, horizontal foot mounted type with class F insulation.M.S. fabricated common base plate, foundation bolts, anti vibration pads etc. including all necessary accessories and cabling required for successful automatic operation of pump as per technical specifications.
od148584/2023_2024 : Supply, installation, testing and commissioning of pressure gauge 0-200 PSI (0 - 14 Kg/sq.cm ) range, 3/8" BSP bottom entry, 100 mm dial weather proof with stainless steel internals including fittings, ball valves etc. complete as required as per technical specification.
od148587/2023_2024 : Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection with IP rated enclosure protection, phosphor bronze bellows as sensing element, SPDT contact system, switch rating 6A Inductive/10A resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC, with ball valve etc. complete as required as per technical specification.
od148596/2023_2024 : Supply, Installation, Testing and Commissioning of 100 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.
od148598/2023_2024 : Supply, Installation, Testing and Commissioning of 80 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.
od148602/2023_2024 : Supply, Installation, Testing and Commissioning of 40 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.
od148603/2023_2024 : Supply, Installation, Testing and Commissioning of 32 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.
od148604/2023_2024 : Supply, Installation, Testing and Commissioning of 25 mm nominal dia MS(Heavy C' Class) pipe IS:1239 marked including Welding, all fittings and accessories such as elbows, flanges, tees, reducers etc. conforming to IS standards complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required. (for fire hydrant and sprinkler system). The pipe shall be painted with one coat of primer & two coats of post office red enamel paint. The pipe shall fixed on ceiling, walls, columns, truss etc for all heights with suitable hangers/ supports and fasteners etc including cutting the walls/means etc and making good the same complete as required as per the technical specification.
od148651/2023_2024 : Supply, laying, testing and commissioning of 'C' class heavy duty MS pipe of 100 mm diameter conforming to IS 1239 including welding, providing fittings like elbows, tees, tapers, flanges, nuts/bolts, gaskets etc., in ground at a depth of 1m from ground level including excavation & providing cement concrete blocks as supports at 3m intervals, anticorrosive wrapping coating of 4mm thickness as per IS10221, refilling the trench etc.complete as required as per the technical specification.
od148608/2023_2024 : Supply, installation, testing and commissioning of dual plate non-return valve of 100 mm diameter, PN16 conforming to API 594 with Cast iron/Cast steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required.
od148611/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 100 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.
od148614/2023_2024 : Supply, installation, testing and commissioning of butterfly valve of 40 mm diameter, PN 16, with Cast iron/Carbon steel body complete with all Accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification and conforming to IS 13095.
od149218/2023_2024 : Providing, installation, testing and commissioning of 100 mm dia Ystrainer with Cast iron/Carbon steel body, SS mesh complete with all accessories including flanges, rubber gasket, bolts, nuts, washers etc. complete as required as per the technical specification.
od148617/2023_2024 : Supply, installation, testing and commissioning single headed internal hydrant valve with instantaneous Gunmetal coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank cap and chain, complete as required as per technical specification.
od148618/2023_2024 : Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as requiredas per technical specification. (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585(b) 20 mm (nominal internal ) dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipments on wall. (d) Connections from riser with 25 mm dia stop valve (gun metal) & M.S. Pipe
od148619/2023_2024 : Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-1) as required as per technical specification.
od148620/2023_2024 : Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required as per technical specification.
od148621/2023_2024 : Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required as per technical specification.
od150048/2023_2024 : Supply, installation, testing and commissioning of 2-WAY FIRE BRIGADE inlet connection made of CI Body, 100mm dia. flanged inlet with 2 Nos. of inbuilt gunmetal, NRV (Body type) with PVC Blank cap & Chain complete with GI nuts, bolts, gasket etc as required as per technical specification.
od150367/2023_2024 : Supply, installation, testing and commissioning of UL listed Standard response, standard coverage sidewall type sprinkler;1/2" NPT, K -5.6, Chrome Finish; operating temperature at 68 deg C complete as required as per the technical specification.
od148629/2023_2024 : Supply, installation, testing and commissioning of Air release valve, 25 mm dia, complete as required as pet the technical specification.
PORTABLE FIRE EXTINGUISHERS
od148571/2023_2024 : Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018 with ISI mark.
od148578/2023_2024 : Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked ) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas, conforming to IS:15683:2018 complete as required as per the technical specification.
FIRE ALARM SYSTEM
od150128/2023_2024 : Supply installation Testing and commissioning of Conventional type Manual Call Point Resettable type via Special Key including back box complete as required as per the technical specification.
od150174/2023_2024 : Providing, installing, testing and commissioning of Conventional type Hooter including base box complete as required as per the technical specification.
od150421/2023_2024 : Supply, installation, testing and commissioning of wall/ceiling mounted 6W speaker including all necessary accessories complete as required as per the technical specification.
od148593/2023_2024 : Supply, installation, testing and commissioning of wall mounted talk back unit for two way communication of fire fighters including all necessary accessories complete as required as per the technical specification.
od148597/2023_2024 : Supply, Installation, Testing & Commissioning of Conventional Type, 10 zone manual operated Fire Alarm Panel including battery backup. The panel shall be microprocessor based with its own micro controller, memory, communication module etc. The panel shall have Keypad operation, LCD unit to indicate Fire Fault Signal of individual unit, etc complete in all respects as required as per the technical specification. The item shall also include 24 Volts sealed lead acid battery sufficient for 24 hrs back up.with battery charger.
od148599/2023_2024 : Supply and laying of 2x1.5 sq.mm armoured Copper FRLS cable ISI marked with proper clamping, supports and terminations appropriately above /below ground,on wall surface or recess as required as per the technical specifications.
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
SIGNAGES
od148573/2023_2024 : Supply and installation of photo luminescent glow signage such as Fire Duct/Fire Lift/Hose reel/Fire Staircase/No smoking etc. of standard size (500*225 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.
od148576/2023_2024 : Supply and installation of photoluminescent glow signage for FIRE ASSEMBLY POINT/ REFUGE AREA of standard size (500*225 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.
od148579/2023_2024 : Supply and installation of photo luminescent glow signage containing standard instructions to the occupants in case of Fire emergency (FIRE ORDER), of standard size (600*800 MM minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws &double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.
od148586/2023_2024 : Supply and installation of photo luminescent glow signage such as Exit/Fire Exit signage etc. of standard size (500*225 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.
od148588/2023_2024 : Supply and fixing (in appropriate location) of Fire Emergency Evacuation Plan (Color) printed in photo paper of Size A2 sand-witched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification and conforming to IS 9457, IS 12349, IS 12407 .Evacuation Plan shall be prepared by the contractor and got approved from Client/Consultant.
ELEVATOR SYSTEM
od168620/2022_2023 : Design, fabrication, supply, installation, testing, commissioning of machine room less electric traction type, 26 Pax (1768 Kg) Stainless steel Hospital elevator (including freight & landing charges ,insurance and all applicable taxes and duties in country of origin and in India etc. without GST) and type suitable for operation on 415 V±10%,, 3 phase , 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec ,electromagnetic brake system, simplex mode operation, operating panel with luminous buttons, over load warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook upto Purchasers EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman switch at initial landing floor, LCD/LED car positions and direction indication in car and landings and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, audio announcement along with pre recorded message as approved by Engineer-in-Charge, all accessories including Automatic Rescue Device (ARD) with dry maintenance free sealed batteries, Safe landing device and Battery operated Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door as required. The drives of elevator shall meet the requirements of IEEE 519/2014. The PMSM traction motor( IE 3 or better efficiency) of machine room less elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification having automatic centre/side opening SS door, Matt finish stainless steel car enclosure provided with stainless steel handrails on two sides, 2mm fluted SS sheet flooring as applicable in accordance of following details:-4 stops & 4 openings and entrance & exit at same side and suitable for travel height of 9.9 mtrs. (Shaft Size 2600 mm (width) x 3300 mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1), door opening of 1200 mm (width) and 2100 mm (height). The equipment should be BMS compatible. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All components ,fabrication, design, installation, testing and commissioning procedures of elevator system shall comply with the latest edition of all applicable standards issued by the Bureau of Indian Standards and complete in all respects as per technical specifications
od168637/2022_2023 : Design, fabrication, supply, installation, testing, commissioning of machine room less electric traction type, 26 Pax (1768 Kg) Stainless steel Hospital elevator (including freight & landing charges ,insurance and all applicable taxes and duties in country of origin and in India etc.without GST) and type suitable for operation on 415 V±10%,, 3 phase , 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1.00 Mtr/sec ,electromagnetic brake system, simplex mode operation, operating panel with luminous buttons, over load warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook upto Purchasers EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman switch at initial landing floor, LCD/LED car positions and direction indication in car and landings and at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, audio announcement along with pre recorded message as approved by Engineer-in-Charge, all accessories including Automatic Rescue Device (ARD) with dry maintenance free sealed batteries, Safe landing device and Battery operated Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door as required. The drives of elevator shall meet the requirements of IEEE 519/2014. The PMSM traction motor( IE 3 or better efficiency) of machine room less elevator shall be of gearless type and placed inside the elevator hoist way complete as per technical specification having automatic centre/side opening SS door, Matt finish stainless steel car enclosure provided with stainless steel handrails on two sides, 2mm fluted SS sheet flooring as applicable in accordance of following details:-9 stops & 9 openings and entrance & exit at same side and suitable for travel height of 24 mtrs. (Shaft Size 2600 mm (width) x 3000 mm (depth) ) with suitable car dimensions (complying with the net inside car area as per IS 14665 part 3/1), door opening of 1200 mm (width) and 2100 mm (height). The equipment should be BMS compatible. All electrical components with wiring from the single point power supply provided in last landing near the elevator door. All components ,fabrication, design, installation, testing and commissioning procedures of elevator system shall comply with the latest edition of all applicable standards issued by the Bureau of Indian Standards and complete in all respects as per technical specifications
STRUCTURED CABLING AND ACTIVE DEVICES
od163701/2022_2023 : Supply, Installation, Testing and Commissioning of U/UTP cable - Category 6, 4 pair, 23 AWG solid copper conductor, 250 MHz, LSZH - with Fluke Cable Analyser through existing conduits including termination, numbering tags, Cable ties, ferrules and all accessories required at site as per technical specification.
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
od163703/2022_2023 : Supply, Installation, Testing and commissioning of concealed Metal Back Box with all accessories required at site complete as per technical specification
od163704/2022_2023 : Supply, installation, testing and commissioning of PVC backbox with all accessories as required at site complete as per technical specification.
od163705/2022_2023 : Supply, Installation, Testing and Commissioning of CAT6 information Outlet, RJ 45 with all accessories required at site including termination complete as per technical specification
od163706/2022_2023 : Supply, Installation, Testing and Commissioning of CAT6 24 port patch panel, fully loaded, with all accessories required at site including termination complete as per technical specification.
od190599/2022_2023 : Supply, Installation, Testing and Commissioning of CAT6 8 port patch panel, fully loaded, with all accessories required at site including termination to complete the work as per technical specification.
od163707/2022_2023 : Supply, Installation, Testing and Commissioning of Single or Dual Shuttered Face Plate with all accessories required at site complete as per technical specification.
od163708/2022_2023 : Supply, Installation, Testing and Commissioning of Cat6 Patch Cord - 1m with end termination for both data and voice with all accessories required at site complete as per technical specification.
od163709/2022_2023 : Supply, Installation, Testing and Commissioning of Cat6 Patch Cord - 2m along with all accessories required at site complete as per technical specification.
od163710/2022_2023 : Supply, Installation, Testing and Commissioning of casing capping with all accessories required at site complete as per technical specification.
od163711/2022_2023 : Supply, installation, testing and commissioning of 12 port LC single mode rack mount Fiber enclosure LIU, fully Loaded (with LC Pigtails, adapters, Couplers, Splice Tray, Splice holder, etc.) with all accessories required at site complete as per technical specification.
od163712/2022_2023 : Supply, installation, testing and commissioning of Fiber patch cord assemblies, 3 meter, LC-LC Single Mode Duplex with all accessories required at site complete as per technical specification.
od163713/2022_2023 : Supply, installation, testing and commissioning of single mode 6 core, OS2 Fibre Optic indoor/outdoor Cable through existing cable tray/conduit/HDPE pipe with all accessories required at site complete as per technical specification.
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 50 mm dia
od163714/2022_2023 : Supply, installation, testing and commissioning of 32mm dia HDPE pipe in surface / ground complete with all accessories including trenching (75 cm deep)and re-filling etc as required at site complete as per technical specification.
od163715/2022_2023 : Supply, Installation, Testing and Commissioning of Wireless Access Point, Wi-Fi 6, dual-band, 2x2 MIMO, PoE, including mounting brackets and all accessories required at site complete as per technical specification.
od163716/2022_2023 : Supply, Installation, Testing and Commissioning of 24 port PoE+ Stackable switch - Layer 2, 24 x 10/100/1000Base-TX PoE+ ports with 2 x 10G SFP+ ports including all necessary hardware, software and accessories as required at site complete as per technical specification.
od163717/2022_2023 : Supply, Installation, Testing and Commissioning of 24 port Core switch - Layer 3, with minimum 20 x 10/100/1000Base-TX ports and 4 x 10G SFP+ ports including all necessary hardware, software and accessories required at site complete as per technical specification.
od190609/2022_2023 : Supply, installation, testing and commissioning of 8 Port PoE switch - Layer 2, 8 x 10/100/1000Base-TX ports with 2 x SFP ports with all necessary hardware & accessories, etc. as required at site to complete the work as per technical specification.
od163718/2022_2023 : Supply, installation, testing and commissioning of 10GBase-LR Transceiver module - 10G over single mode fiber, LC type with all accessories required at site complete as per technical specification.
od190611/2022_2023 : Supply, installation, testing and commissioning of 1GBase-LR Transceiver module - 1G over single mode fiber, LC type with all accessories required at site to complete the work as per technical specification.
od163719/2022_2023 : Supply, installation, testing and commissioning of next generation Firewall having a capacity of handling 1500 concurrent users with logs, monitoring, bandwidth management, security subscriptions, including software, licenses and all accessories required at site to complete the work as per technical specification
od163720/2022_2023 : Supply, installation, testing and commissioning of 27U Network Rack along with all necessary hardware and accessories, etc. required at site complete as per technical specification.
od163721/2022_2023 : Supply, installation, testing and commissioning of 15U Network Rack along with all necessary hardware and accessories, etc. required at site complete as per technical specification.
od190616/2022_2023 : Supply, installation, testing and commissioning of 9U Network Rack along with all necessary hardware and accessories, etc. required at site to complete the work as per technical specification.
IP SURVEILLANCE
od163700/2022_2023 : Supply, Installation, Testing and Commissioning of 2MP varifocal IP camera, PoE, IP66 rated with all accessories required at site complete as per technical specification.
od163702/2022_2023 : Supply, installation, testing and commissioning of 32 channel Network Video Recorder, RAID5 with SAS / Enterprise HDDs for 30 days storage, operator desktop, cabling and all accessories as required at site to complete the work as per technical specification
HT EQUIIPMENT
od73117/2022_2023 : 11kV Outdoor RMU panel-3 (Extensible Type) - Design, Fabrication, Supply, Installation Testing and Commissioning of 11KV electrically Operated 21kA for 3 sec, 630A SF6 Insulated,Ring Main Unit outdoor type (IP-54) with 2 nos motorised Load break switch as incomer and 3 no motorized VCB (fully rated earth switch) with fully encapsulated vacuum interrupter panel as outgoings, 630 Amp continously rated Cu busbar complete with all accessories, protective relays, indicators,battery and battery charger, Manometer for indicating SF6 gas pressure with green zone marked on the scale,provision for padlocking for open, close, earth and test position etc. on a existing foundation. The RMU must be both side extensible type .The rate quoted shall be inclusive mounting accessories, hoisting to its location,assembling of units,lining up, bolting the units and checking all control wiring complete as per single line diagram & technical specification.The LBS & VCB shall be enabled with VIPS and LBS shall be equipped with Fault passage indicator.
od299470/2023_2024 : UNITIZED SUBSTATION- 250KVA DRY TYPE: Design, fabrication, Supply, installation, testing and commissioning of outdoor type Unitized Substation including foundation for 250 kVA, 11kV/433V 3 Ph, 50 Hz, vector Dyn -11, dry type, Transformer with outdoor enclosure, winding temperature alarm and trip on transformer compartment and LV chamber suitable for termination of cable, complete with all standard fittings and accessories etc including necessary louvers and as per specifications attached in all respects as required. It shall includes all necessary control cabling for alarm, tripping & indication, all internal cabling as required. The rate shall be inclusive of all materials, lead, lift, necessary civil works etc. complete as per single line diagram & technical specification. HT Chamber 630A, 21kA ,11kV LBS with earth switch. Transformer Compartment: 250kVA, 11kV/433V 3 Ph, 50Hz, DRY type, vector Dyn -11 Transformer, copper wound, Class F insulation, indoor distribution Transformer (AN). Losses shall be as per ECBC guidlines amended upto date. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: + 10% to -10% in steps of 2.5%. The transformer shall have suitable enclosure for providing neutral CT of 70/5A 15VA 5P10 on earthed star point with connector for connection Earth Fault relay in HT/LT panel as per SLD "The transformer shall also have suitable enclosure including supply and fixing of neutral CT of 70/5A 10VA 5P10 on earthed star point with connector for connection to Earth Fault relay in LT side. LT Chamber: LT Chamber:400A FP thermal based MCCB and shall be suitable for terminating 2 RUN x185 sq.mm Al cable.
od112759/2022_2023 : Convertion of of existing 4P structure to 6 P structure Supply, Installation testing and commissioning of all necessary materials required for convertion of Existing 4P structure to 6P structure . The materials like 200x100 mm ISMB for poles, cross channel of ISMC 100x50mm ,supporting structure for 11 KV components with 65x65x6 mm MS angle bracings between existing and proposed structure, cross arms,11 KV pin,disc and stay insulators, supports, jumpering / interconnecting conductors with '0'SWG Cu, anticlimbig arrangement using barbed wire,earthing etc. on a suitable concrete foundation are considered in the item. It is exclusive of the civil foundation .The structure shall consists of the following Note:All the MS items shall be hot dip galvanised) 11 KV,400A ,TP,AB switch - 1 No. 11 KV Lighting Arrestor -1 set of 3 Nos 11 KV Do fuses-1 set of 3 Nos
DG SET AND ACCESSORIES
od341149/2023_2024 : 82.5 kVA DG Set: Supply, Installation, Testing and Commissioning of 82.5 kVA prime rated D.G Set with acoustic enclosure and Control panel, protection and digital metering, controls and interlocks, CTs and transducers for all metering and protection and suitable FP MCCB etc., including Anti-vibration mountings, exhaust silencer and exhaust pipe suitable thermal insulation with mineral wool or equal insulation coverd with Aluminium cladding for silencer and exhaust pipe, conforming to latest environment protection regulations for emission (CPCB IV+).and noise levels complete with , water/ coolant cooled, (radiator type) Engine: 82.5 kVA Prime rating four stroke, electric start conforming to BS: 5514, brushless, self excited, self regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 & IS: 4722. Alternator: 82.5 kVA Prime rated, as per the technical specification, Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards, Fuel tank for 8 hours suitable continuous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per the technical specifications.. The work should be as per Electrical Inspectorate/ Central Pollution control board standards applicable at the time of delivery.
LT PANEL BOARDS AND UPS
od300617/2023_2024 : UPS AND ACCESSORIES Supply , Installation, Testing and Commissioning of 1 kVA, single phase input, single phase output, true on-line UPS system with 15 minutes back up , output isolation transformer, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit andone set of battery bank . Fully digital controlled based on DSP Power factor corrected from end > 0.9 Pure sine wave output. Full time output voltage & frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch Auto temperaturecompensation
od301221/2023_2024 : TQ--2 BHK-Metering Panel 2,3,4,5, TYPICAL Supply, Installation, Testing & Commissioning of fully type tested 415V, 50Hz, LT switch board fabricated from CPRI/ERDA approved vendors. The enclosure shall be 2 mm thick CRCA sheet which shall be free standing with floor mounting base with following switchgears, metering instruments and accessories etc. as per drawing & specifications as required to complete installation. The IP rating shall be 42 or better and form of construction shall be form 3B or higher. The short circuit rating shall be suitable to with stand the SC rating of incomer breaker (the design calculation for the mechanical strength of busbar supports, spacing between supports, temperature rise etc shall be furnished). The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire. Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top/bottom cable entry. Incomer: 160A, 25kA, FP MCCB with thermal release and neutral link ( Ics = 100% Icu = 25kA) - 1 no. Busbar 160A TPN AL BUSBAR. Outgoings: 3 phase , 415V- flush mounted electronic type energy meter class1(as per K.S.E.B standards) - 8Nos. 25A HRC fuse with fuse link - 24 nos, Neutral link - 8 nos, 25A, FP MCB isolator - 8nos, 25A TPN/ 2.5 A SPN ACCL - 8 Nos (set at 0.5 kw for single phase load)-8 nos. All outgoing feeders should have glass window for meter reading and locking facility for KSEB.
od301222/2023_2024 : TQ--2 BHK-Metering Panel -1: Supply, Installation, Testing & Commissioning of fully type tested 415V, 50Hz, LT switch board fabricated from CPRI/ERDA approved vendors. The enclosure shall be 2 mm thick CRCA sheet which shall be free standing with floor mounting base with following switchgears, metering instruments and accessories etc. as per drawing & specifications as required to complete installation. The IP rating shall be 42 or better and form of construction shall be form 3B or higher. The short circuit rating shall be suitable to with stand the SC rating of incomer breaker (the design calculation for the mechanical strength of busbar supports, spacing between supports, temperature rise etc shall be furnished). The enclosure shall be powder coated after 7 tank process. The control wiring for voltage circuit shall be with 1.5 sq.mm and for current circuits with 2.5 sq.mm HFFR wire. Protections for control devices shall be with appropriately rated HRC fuses. The panel shall be suitable for top/bottom Cable entry. Incomer 40A, 25kA, FP MCCB with thermal release and neutral link ( Ics = 100% Icu = 25kA) - 1 no. Busbar 40A TPN AL BUSBAR. Outgoings: 3 phase , 415V- flush mounted electronic type energy meter class1(as per K.S.E.B standards) - 2No. 25A HRC fuse with fuse link - 6 nos. Neutral link - 2 nos. 25A, FP MCB isolator - 2nos. 25A TPN/ 2.5 A SPN ACCL - (set at 0.5 kw for single phase load)-2 nos. All outgoing feeders should have glass window for meter reading and locking facility for KSEB. Space provision for 2 sets of 25A metered outlets with HRC fuse, neutral link cutout and energy meter with glass window for meter reading , locking facility and ACCL
CABLES AND CABLING
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
7.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm
7.1.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm
7.4.1 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Upto 35 sq. mm
7.4.2 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Above 35 sq. mm and upto 95 sq. mm
7.4.3 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Above 95 sq. mm and upto 185 sq. mm
7.4.4 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Above 185 sq. mm and upto 400 sq. mm
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
7.5.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm
7.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
7.6.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia
14.14.1 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100 mm dia
14.14.4 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.300 mm dia
4.6.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.6.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.6.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.600 mm width X 50 mm depth X 2.0 mm thickness
4.6.1 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness Details of cost for 30 metres
4.6.3 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.225 mm width X 50 mm depth X 1.6 mm thickness
4.6.5 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.375 mm width X 50 mm depth X 2.0 mm thickness
4.6.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.450 mm width X 50 mm depth X 2.0 mm thickness
4.7.1 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
4.7.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.7.3 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.225 mm width X 50 mm depth X 1.6 mm thickness
4.7.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.7.5 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.375 mm width X 50 mm depth X 2.0 mm thickness
4.7.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
4.7.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness
4.8.1 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
4.8.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.8.3 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.225 mm width X 50 mm depth X 1.6 mm thickness
4.8.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.8.5 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.375 mm width X 50 mm depth X 2.0 mm thickness
4.8.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
4.8.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness
4.9.1 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray ?Cross member? ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
4.9.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray ?Cross member? ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.9.3 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray ?Cross member? ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.225 mm width X 50 mm depth X 1.6 mm thickness
4.9.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray ?Cross member? ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.9.5 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray ?Cross member? ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.375 mm width X 50 mm depth X 2.0 mm thickness
4.9.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray ?Cross member? ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
4.9.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray ?Cross member? ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness
4.10.1 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
4.10.2 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.10.3 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.225 mm width X 50 mm depth X 1.6 mm thickness
4.10.4 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
4.10.5 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.375 mm width X 50 mm depth X 2.0 mm thickness
4.10.6 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
4.10.7 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 50 mm depth X 2.0 mm thickness
od301910/2023_2024 : Providing, laying and fixing following dia RCC pipe NP4 class HEAVY duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (1.2 m deep) and refilling etc as required. 300 mm dia
od101075/2022_2023 : Laying of one no. PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in recess/ surface/ cable tray/ wall with saddles, clamps and all other accessories as required Above 120 sq. mm and upto 400 sq. mm
7.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
od300897/2023_2024 : Supplying and making end termination with brass compression gland and aluminium/Copper lugs for following size of XLPE insulated PVC sheathed cable of 1.1 kV grade as required." 4C 4 Sq.mm 1.1 KV grade Cu. Conductor
od301281/2023_2024 : Supplying and making end termination with brass compression gland and aluminium/Copper lugs for following size of XLPE insulated PVC sheathed cable of 1.1 kV grade as required. ;3C 4 Sq.mm 1.1 KV grade Cu. Conductor
od301116/2023_2024 : Supplying and making end termination with brass compression gland and aluminium/Copper lugs for following size of XLPE insulated PVC sheathed cable of 1.1 kV grade as required. ;2C 4 Sq.mm 1.1 KV grade Cu. Conductor
od101727/2022_2023 : Supply of 3.5C 120 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
od101729/2022_2023 : Supply of 4C 16 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
od101730/2022_2023 : Supply of 4C 35 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
od101731/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 4 Cu
od101732/2022_2023 : Supply of 2C 4 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.
od101733/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 3C 4 Cu
od101734/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 240 Sq mm
od101735/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 3C 10 Sq.mm 1.1 KV grade Al. conductor
od101812/2022_2023 : Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required
od73380/2022_2023 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 185 Sq mm
od101489/2022_2023 : Supply of 3.5C 95 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.
od164983/2023_2024 : Supply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV grade conforming to IS 7098 amended upto date. 3C X 300sq.mm.
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm
8.2.2 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etcAbove 120 sq. mm and upto 400 sq. mm
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm
8.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm
10.6.4 : Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm
WIRING AND ACCESSORIES
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
15.1 : Supplying,Installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.8 Mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming and site etc. complete as required
1.17.1 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.30 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
od215672/2024_2025 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
od215673/2024_2025 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable with earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable utilizing the existing surface/recessed PVC conduit and switch box as required. Group C
od215674/2024_2025 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable with 2 way modular switch, modular plate and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable utilizing the existing surface/recessed PVC conduit and switch box as required.
od215675/2024_2025 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable with modular switch, modular plate and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required utilizing the existing surface/recessed PVC conduit and switch box. Group C
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.2 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.3 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
1.28.6 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module
MCB AND DISTRBUTION BOARDS
2.3.8 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator2+12 way, Double door
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
od103126/2022_2023 : Supply and fixing of following 40-63A TP MCB, C-Curve rating, 10 KA, Miniature Circuit Breakers as required
od103127/2022_2023 : Supply, Installation, Testing & Commissioning of 63A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.
od145378/2022_2023 : Supply, Installation, Testing & Commissioning of 25A DP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
od147236/2023_2024 : Supplying and fixing following rating, 25 A four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
od147237/2023_2024 : Supplying and fixing following rating, 40 A four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
od301063/2023_2024 : Supply and fixing of following 40-63A FP MCB, C-Curve rating, 10 KA, Miniature Circuit Breakers as required
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
od300945/2023_2024 : Supply and fixing of 6-32A FP MCB, C-Curve following rating, 10 KA, Miniature Circuit Breakers as required
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.3.1 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.23.1 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 6 way, Double door SPN MCBDB
2.23.4 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 14 way, Double door SPN MCBDB
2.24.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB
od147591/2023_2024 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
LIGHT FIXTURES AND FANS
od103139/2022_2023 : Supply of 225 mm sweep,900 rpm light duty exhaust fan in metal body working on 230 V AC supply complete with all accessories as required.
od103140/2022_2023 : Supply of 400 mm size wall mounting oscillating type fan having three speed control, oscillation control at bottom and suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor, chrome plated front and rear gaurds and all accessories as required complete.
od103151/2022_2023 : Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.(Rate shall inclusive of supply and installation of remote/electronic regulator)
od103508/2022_2023 : Installation, testing and commissioning of Wall fan, including all the supports as required and wiring using 3 runs of 1.5 sqmm FR PVC insulated stranded copper conductor etc complete.
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.5 : Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
1.42 : Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
od153643/2023_2024 : Supply of 40W Surface/Suspended Mounted LED Batten with System efficacy of more than 120 lm/W and lumen output of luminaire greater than 4000 lumen. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with LM80 standard with Useful L70 life of 50000 Hrs tested at maximum current. The CRI of Minimum 80 and 4 KV internal surge protection. Power factor greater than 0.95 , ripple factor<5, CCT 5700+/-300Kand total harmonic distortion (THD) of less than 10% should be integral to the luminaire and EMI/EMC compatible
od153644/2023_2024 : Supply of 20W Surface/Suspended Mounted LED Batten of maximum wattage below 20W with System efficacy of more than 120 lm/W and lumen output of luminaire greater than 2000 lumen. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. The LED shall be compliant with LM80 standard with Useful L70 life of 50000 Hrs tested at maximum current. The CRI of Minimum 80 and 4 KV internal surge protection. Power factor greater than 0.95, CCT 5700+/-300K , ripple factor<5and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. EMI/EMC compatible
od301515/2023_2024 : Supply of IP 65 & IK 08 LED surface mounted Bulkhead fixture with System efficacy of more than 105 lm/W. Luminaire shall be made up of Die Cast Aluminium for efficient heat dissipation. Luminaire shall have Polycarbonate diffuser for Uniform illumination and wider light distribution. The LEDs used should be with CCT of 5700 K and CRI > 70, Power factor greater than 0.9 and total harmonic distortion (THD) of less than 10% including all accessories necessary as required to complete installation.
od303935/2023_2024 : Supply of 10W High efficient LED batten surface/wall mounted, System efficacy of more than 120 lm/W and lumen output of luminaire greater than 1000 lumen, designed extruded channel in thermally conductive material with plastic with HET diffuser. CRI >80, Power factor>0.9, CCT - 5000-6000 K, 50000 burning hours as per L 70 criteria and EMVEMC compatible
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
od98785/2022_2023 : Supply of 450mm sweep heavy duty exhaust fan in die cast aluminium with metal grill/ louvers working on 230 V AC supply complete with all accessories as required.>
od100411/2022_2023 : Supply, installation, testing and commissioning of indoor Architectural LED light fixture as per architects choice with base price of Rs. 2000.
EXTERNAL LIGHTING
90.15.3.5 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters
90.15.3.6 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
od218637/2024_2025 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing streetlight pole complete with connections, testing and commissioning etc. as required. 25 amps
od218059/2024_2025 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more (As per civil DSR 5.22.6)
od218060/2024_2025 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.(As per civil DSR 2.25. )
od218061/2024_2025 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2.(As per civil 50.18.8.4.2 )
od218062/2024_2025 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) (Civil DSR 13.16.1)
od218063/2024_2025 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete (As per Civil DSR 5.9.1)
od218748/2024_2025 : Centering and shuttering including strutting, etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts( As per civil DSR 5.9.6)
od218064/2024_2025 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work above plinth level upto floor level
od218065/2024_2025 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) ( As per Civil DSR 4.1.8 )
od218066/2024_2025 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil ( As per civil DSR 2.6.1)
90.12.1.3 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 10 sq mm
90.12.2.3 : Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)2 core 10 sq mm
90.6.5.11 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
9.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
90.16.1.11 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG)
EARTHING AND SAFETY EQUIPMENTS
od103693/2022_2023 : Supply and installation of maintenance free earthing system including 3 mtrs length,17.2mm dia or above 250 microns molecularly copper bonded steel rod with stainless steel connectors and fasteners for connecting earth strip, earth enhancing compound (12.5 kg mineral compound / 22.6 kg low resistivity graphite compound) and providing Heavy duty enclosure & cover plate as required complete.
od103717/2022_2023 : Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2 mm for 3.3kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound .
od104443/2022_2023 : Supply and fixing anodised aluminum glass framed shock treatment chart.
od104444/2022_2023 : Supply and fixing of First aid box .
od104446/2022_2023 : Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as required.
od104447/2022_2023 : Supplying and laying 8 SWG G.I. wire at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of nut bolt & spring washer spaced at 50mm)
od104448/2022_2023 : Providing and fixing 3.15mm (10SWG) copper wire on surface or in recess for connections etc. as required.
od104449/2022_2023 : Supplying and laying 3.15mm Cu (10 SWG) Copper wire at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of nut bolt & spring washer spaced at 50mm)
od104450/2022_2023 : Supplying and laying 50 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
od104451/2022_2023 : Providing and fixing 50 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required.
od104453/2022_2023 : Supply and fixing single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required complete on wall.
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
od98997/2022_2023 : Supply and fixing single line diagram, schematic diagrams etc. of A0 size including lamination etc. as required complete on wall.
od99001/2022_2023 : Supply and fixing single line diagram, schematic diagrams etc. of A1 size including lamination etc. as required complete on wall.
od99002/2022_2023 : Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of 1m x 1m x 2 mm for 3.3kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound .
od99005/2022_2023 : Supply and fixing of fire retardant/extinguishing electrical insulated synthetic mat of 1m x 1m x 2.5 mm for 11kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 11kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound
od99063/2022_2023 : Supply and fixing of First aid box
od99064/2022_2023 : Supplying of Rubber hand gloves suitable for 11 KV.
5.6 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
LIGHTNING PROTECTION SYSTEM
6.14 : Providing and laying G.l. tape 32 mm X 6 mm from earth. electrode directly in ground as required.
od302728/2023_2024 : Providing and fixing of test joint suitable for hot dipped galvanized steel tape 32 mm x 6mm and 8mm dia solid round aluminium conductor conforming to the requirements according to (IS/IEC 62305) with all accessories complete as required."
od302729/2023_2024 : Supply and Fixing of following height Airterminals as per IS-IEC -62305 part-3 with 16mm rod tapered to 10 mm aluminium rod with the required accessories like Fang Fix with base, clamps, Stone ,anchors etc . as required per IEC 62305-32Mtr Airterminal
od302730/2023_2024 : Supply and Fixing of following height Airterminals as per IS-IEC -62305 part-3 with 16mm rod tapered to 10 mm aluminium rod with the required accessories like Fang Fix with base, clamps, Stone ,anchors etc . as required per IEC 62305-3 4Mtr Airterminal
od303107/2023_2024 : Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3
od303402/2023_2024 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace with the required mounting clamps , cross connectors expansion piece and other accessories required as per IEC62305-3
od303403/2023_2024 : Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for Sheet roof with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .