| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.7 L+₹326.11 (0.07%)Rejected-AOC 79 7561 J K ROY CHOWDHURY LANE HALISAHAR ARABINDA PALLY P O HALISAHAR NORTH 24 PARGANAS | HALISAHAR | NORTH 24 PARGANAS | WEST BENGAL | L2 | Rejected-AOC L2 | |
| 3 | L3₹4.7 L+₹559.04 (0.12%)Rejected-AOC 96 A KALYANI SIMANTA P O P S KALYANI NADIA PIN 741235 | KALYANI | NADIA | WEST BENGAL | 741235 | L3 | Rejected-AOC L3 |
Tender Value
₹4.7 L
EMD Value
₹9,317
Closing Date
18 Feb 2026, 9:00 amClosed
Chairman of Halisahar Municipality
Halisahar Municipality PO. Halisahar, PS. Halisahar, North 24 Parganas, Pin-743134
RENOVATION WORK OF COMMUNITY HALL NEARBY HARI MANDIR (9M X 9M). WARD NO. 13, UNDER HALISAHAR MUNICIPALITY.
2026_MAD_1001764_51
WBMAD/ULB/HM/APAS-12 (2025-26)
Open Tender
CIVIL WORKS
Percentage
30 days
HALISAHAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹9,317
22 Apr 2026
10 Feb 2026
20 Feb 2026
10 Feb 2026
18 Feb 2026
10 Feb 2026
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) (P.No.42, T/36/a) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. (d) Extra for works beyond the roof of ground floor per additional floor (i) upto 4th (per floor) and in basement. 1ST FLOOR
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(Ground floor) (a) Pakur/Chandil variety. (P.No.26 T/10(i)), 3rd corrigenda, In first floor. Addextraover the rateof ground floor forbasement andeachadditional floor above ground floor for items 1, 4 to 22 of subhead B (i) upto 4 th floor.(1st floor)
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (P-43, T/40), 9 th corrigenda, (b)Add extra over the rate of ground floor /initial 4m for each basement floor and each additional floor below/ above ground floor (i) Upto 4 th floor roof in each addl. floor (ii) Tor steel (12 ,10 ,8 mm) 1.10 % of Concrete Volume
Brick work with 1st class bricks in cement mortar (1:6) Add extra for each additional floor over the rate for ground floor on items from In Superstructure 1st floor 3rd corrigenda, (P.no-15,T/8)
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.(1st floor) P.no. 16, T/16) Add extra for each additional floor over the rate for ground floor on items from
M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1957 & IS: 1161- 1958 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816-1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. /2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. eyond the initial 8 m. or part thereof. (P.No.100, T/2 )3rd corrigenda, i) For trusses spanning up to 12.00 m 40 mm.
Supplying, fitting & fixing Industrial Troughed Aluminium sheet (excluding the supporting frame work) of approved make & brand in alloy 3105 conforming to IS: 1254-1991 fitted and fixed with 75 mm & 25 mm Self tapping screw , EPDM Washer 16 mm dia & 3 mm th washer etc complete with 150 mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work) (Aluminium sheet to be supplied by contractor). P.no. 83, T/17 (i) (a)) i) In Roof:- a) With 0.65 mm thick sheet
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] 3rd corrigenda (P.No.107, T/20)
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(1st floor) (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. (Addextra@1%foreachaddl. [email protected]% for each addl. floor above 4th floor) (In 1st floor) (P.No.104 T/13(I)),
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps.(The quantum should be correted upto three decimals). (d) Sal : Local. P.no. 114, T/1/d)
Supplying, fitting and fixing M.S.clamps for door and window frame made of flat bent bar,end bifurcated with necessary screws etc.by cement concrete (1:2:4) as per direction. (Cost of concrete will be paid separately) (b) 40mm X 6mm, 200mm Length (P-140, T-4/B)
Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and theentire frame fitted with 27.5mm wide batten splaces bothways inorder to made the door of solid core and internal lippingwith teak, mahogony or rose wood approved decorative veneersusing phenol formaldehyde as glue etc.complete, including fitting, fixing the shutters inposition but excluding the cost of hinges andother fittings in ground floor: (a) 35mm thick shutters (single leaf) P.no. 124, T/12/a)
Iron butt hinges of approved quality fitted and fixed with steel screws,with ISI mark. (viii) 100mm. X 75mm. X 3.50mm. (P-140, T-05)
Anodised aluminiumbarrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fittedand fixed with cadmium plated screws: (x) 300mm long x 12mm dia. bolt. (P-144, T-26/X)
ii)Brass hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.(c) 300mm long. (P-140, T-6)
Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5 mm th. both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in-Charge. In ground floor. (P-125, T/15)
Labour for Chipping of concrete surface before taking up Plastering work. (P-192, T-1)
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary .[Excluding cost of chipping over concrete surface] A) In Ground floor 10mm thick plastering at ceiling of roof slab beam etc. with cement mortar (1:4) at 1st.floor P.no. 189, T/ii/c) (P-189, T-1) 3rd corrigenda,
Extra for each additional floor over the rate for ground floor items : 1 to 3 of subhead A :(1st floor) (a )With 1:6 cement mortar a) 15 mm thick plaster 1ST floor (out side plaster)
With 1:6 cement mortar (b) 20 mm thick plaster in 1st floor Extra for each additional floor over the rate for ground floor items
1 to 3 of subhead A : (i) External plaster & (ii) Internal plaster
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m. (P-192, T-15)
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative (P-64, T-35)
Supplying and laying true to lineand level vitrified tiles of approved brand (size not less than 600mmX600mmX10 mmthick) in floor, skirting etc. set in20mm sand cement mortar (1:4)and 2mm thick cement slurry back side of tiles using [email protected]./sq Morusing polymerised adhesive (6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurryusing1.75Kgof cement per sqMbelow mortar only, joints grouted with admixture of white cement and colouring pigment tomatch with colour of tiles / epoxy grout material so fapproved make as directed and removal of wax coating of top surface of tiles withwarmwater and polishing the tile susing soft and dry cloth upto mirror finish complete including thecost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement , synthetic adhesive and grout material to be supplied by the contrr]e (I) With application slurry @1.75kg/ Sq.m, 20mm sand cement mortar(1:4)&2mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (B) Light Colour (P-66, T-36) 3rd CORRIGENDA & ADDENDA
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (P-200, T/1 a)
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (P.200, T/1 (B)) Timber surface area
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. Including using of approved putty etc. on the surface, if necessary : (P-200, T/2 b, iv) (a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white) (Timber area)
(b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats (P-196, T/10)
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (a) One Coat (P-196, T/8(a))
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. Two Coats / In Ground floor (Two Coat) a) Normal Acrylic Emulsion (P-197, T/8)
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (ii) 550 mm X 400 mm size (P-41, T/2 (ii) )SANITARY & PLUMBING WORKS 2017
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.(iv) 1050 mm long (P-43, T/10)SANITARY & PLUMBING WORKS 2017
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) PVC Pipes (P-12, T/19 (I) )SANITARY & PLUMBING WORKS 2017 (a) For Exposed Work (i) 20 mm. Dia.
(ii)15 mm Dia
(ii) 40 mm Dia
Supplying, fitting and fixing bib cock or stop cock (e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm (P-6, T/7 (e) )SANITARY & PLUMBING Bib Cock
Stop Cock
(c) (i) Chromium plated Bib Cock (angular shape with wall flange) (Equivalent to Code No. 5037 & Model- Florentine of Jaquar or similar brand).
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. (P-36, T/2 )SANITARY & PLUMBING WORKS 2017
Supplying,fittingand fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.(iii) 600 mm long (P-43, T/9)SANITARY & PLUMBING WORKS 2017
Suppling, fitting and fixing WALL HUNG TYPE water closet (European type) size - 500x360x350 mm of white glazed vitreous chinaware of approved make and brand in position complete with necessary nut and boalts (MODEL CARAT of CERA or equivalent.) (P-83, T/27)SANITARY & PLUMBING WORKS 2017
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. (P-212, T-21/A/2) 3rd corrigenda, (ii) 110 mm. Dia.
B) UPVC Fittings: a) Plain Tee (ii) 110 mm. Dia.
Labour for hoisting plastic water storage tank. (ii) Above 1500 litre upto 5000 litre capacity.(a) Upto 2nd story from G.L (P-37, T/10)SANITARY & PLUMBING WORKS 2017
Labour for punching hole in plastic water storage tank upto 50 mm dia (P-38, T/13)SANITARY & PLUMBING WORKS 2017
Add GST @ 18%
Add Cess 1%
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.40 MB
Tendernotice_2.pdf
PDF • 1.16 MB
BOQ_2454948.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .