Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance NEW GENERAL STORE PERINJANAM P O THRISSUR 680686 | THRISSUR | THRISSUR | KERALA | 680686 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹2,400
Closing Date
12 Feb 2026, 2:00 pmClosed
DIVISIONAL MANAGER
OFFICE OF THE DIVISIONAL MANAGER, MUNNAR DIVISION MATTUPETTI ROAD, MUNNAR-685 612
E TENDER FOR SUPPLYING MATERIAL ERECTING SOLARFENCING IN MANKULAM SUBUNIT -KOOTAKUZHY- OF MUNNAR DIVISION OF KERALA FOREST DEVELOPMENTCORPORATION DURING THE YEAR 2025-26
2026_KFDC_831357_1
DM/MNR/SF/1914/2022
Open Tender
Miscellaneous Works
Item Rate
60 days
KFDC MUNNAR KOOTTAKUZHY
Please refer Tender documents.
7 documents required · 7 mandatory
₹710
Yes
₹2,400
Yes
13 Feb 2026
28 Jan 2026
13 Feb 2026
28 Jan 2026
12 Feb 2026
28 Jan 2026
28 Jan 2026 - 12 Feb 2026
Supply of power fence Energizer (10KV)of standard make conforming ton impulse repetition period greater than or equal to 1 second and impulse duration with 500 ohm load of about 5 joules and capable of energizing over a distance of 2 kilometres
Supply of crystalline silicone terrestrial photo voltanic module conforming to ILC 612115/IS 14286 with peak wattage of 150 watts carrying the name of the manufacture of Pvmodule and manufacturer of solar cells
Supply 12 V battery to be charged with solar photo voltanic module with rated capacity of 100 AH generally lead acid tubular battery for energizing the energizer. - 5 year warranty
Supply of charge controller unit(10 Amp) of standard make suitable to control the charging of the tubular battery. Automatic system
Supply of lightning diverter of standard make having capacity to divert up to 20 KV
Supply of Intermediate posts including cost of T Angle,cutting, welding and painting charges (8 ft, 25mmx25mmx3mm)
Supply of Corner posts assembly including cost of GI pipe, cutting, welding and painting charges (8ft GI 2" 14 guage)
Supply of support post to the corner post made of GI pipe, cutting,welding and painting charges (8 ft GI 1.5'')
Supply of HT wire of standard make 2.59 mm size (12gauge) zinc coating for use as conducting wire.
Supply of 14gauge wire, high tensile, zinc coated for winding the PP reel insulator etc. (14 gauge)
Supply of Lead out cable-double insulated inner core wire of withstanding 15 KV voltage for connecting purpose Super strain insulator made of virgin polymer UV stabilized eire resistant
Supply of Super strain insulator made of vergin polymer UV stabilized fire resistant and suitable to withstand 15 kv voltage.
Supply of PP reel insulator madeof virgin high density poly propylene with break down voltage of 15 KV
Supply of tension spring made of hot dipped steel of standard make
Supply of Wire tightner made of Aluminium-silicon alloy
Supply of Joint clamp, zinc coated, 60 micron thick
Supply of clamp for fastening conducting wire around posts hot dipped galvanized.
Supply of Warning signs made of long standing polymer sheet of yellow colour with black lettering
Supply of rope gate set consisting of steel rope of 5 meters along with one super strain insulator, insulated handle and hook assembly.
Supply of Earth Device consisting of steel rod with earthing mixture - bentonite clay (1.5"pipe) 5 feet length.
Supply of Base unit box for housing energizer battery, charge control unit etc. Body of which is made of Alumminium plate, painted coated provided with stand of 1 meter height made of four legs of Ms pipe of 25mm or MS 25mm x25mm x 3mm or single leg of painted MS pipe of 50 mm diameter.
Supplyof Digital voltmeter of standard make
Supply of Tool kit consisting of wire tighter rod, double headed spanner, high tensile wire cutter and cutting player.
Supply of Neon tester for testing line voltage
Cost of installation including boundary clearance and transportation (1000 m x 5 line = 5000 mtr) Cost of installation including boundary clearance (1000 m x 6 line = 6000mtr x Rs 7/- (Aligning the fence in the field asper the direction of departmental officers, clearing the fence line of all weeds to a 1.5 mtr, fixing corner posts at an approximate distance 50m inputs of size 30 cmx30 cm x45 cm in hard soil consolidated by ramming gravel and jungle stone pieces and supported by support posts by hammering the same into hard earth to a depth of 45cm,drawing the conducting wire through PP reel insulators tied to the intermediate posts using winding wire and stretching to required strength by connecting the ends to super strain insulators tied to the corner post in 6 strands, the bottommost line at an average height of 15 cms from the ground and the other strands at an approximate intervals of20 cm,25cm, 30 cm and 40 cm connecting conducting wire in every strand across each corner post by means of jointing clamps, fixing wire tightner in every strand at approximate interval of 200 m, providing flood chainset and flood control unit at river cross points, connecting super earth kit to the earth conductor by means of lead out cable and joining clamp, fixing vertical conducting, wire in the forest side of the fence supported by semi-circular conducting wire loop fixed to the conducting wire strand by means of joining clamp for protecting the post from wild animals providing gate assembly at places as decided by the departmental officers by means of rope gate set fixed to corner post acting as gate posts by means of super strain insulators at the fixed end and conducting hook at detachable end providing line connection at the gate point through lead out cable laid underground and energising the live conductors of the fence by means of the energizer fixed at suitable locations at approximate distance of 1.000 km along the fence, connected to the live wire earth wire by means of lead out cable providing sufficient number of earth kits in the line to the tubular battery to the energizer through lead out cable and connecting the solar panel to the battery by means of 2 core wire through charge control unit and fixing lightning diverter in the circuit at appropriate location to protect the energizer from lightning voltage providing and fixing strands for the solar panel and metallic box for safe storage of energizer and battery testing the circuit for required current Voltage and commission
finance_1396955.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
prelimanaryAGREEMENTKTKZY.pdf
Tender Documents • 0.06 MB
decl3.pdf
Tender Documents • 0.03 MB
decl4.pdf
Tender Documents • 0.43 MB
BOQ_1396955.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .