Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance S M C ROAD GHUNGOOR SILCHAR DIST CACHAR ASSAM PIN 788014 | SILCHAR | CACHAR | ASSAM | 788014 | Admitted-Finance |
| 2 | Admitted-Finance HOUSE NO 43 SILCHAR HOUSE NO 43 VIVEKANANDA ROAD LANE NO 28 VILLAGE TOWN SILCHAR CITY SILCHAR CACHAR ASSAM 788007 INDIA | CACHAR | ASSAM | 788007 | Admitted-Finance |
Tender Value
₹1.4 L
EMD Value
₹2,811
Closing Date
12 Sept 2024, 11:00 amClosed
EXECUTIVE ENGINEER
ENGINEERING SECTION, ASSAM UNIVERSITY SILCHAR
Electrical repairing and replacement of UG power cable and necessary lab power points at ECE (TSSOT) department, AUS.
2024_AUS_824785_1
AU/Engg/Maint/Elect/65/2022
Open Tender
Electrical Works
Works
20 days
ASSAM UNIVERSITY SILCHAR
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Assam University Silchar
₹2,811
20 Sept 2024
6 Sept 2024
13 Sept 2024
6 Sept 2024
12 Sept 2024
6 Sept 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 3 x 2.5 sq. mm(RR kable/Havells/Finolex )
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire(RR kable/Havells/Finolex )
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch (L&T /Legrand/Havells)
3 pin 5/6 A socket outlet (L&T /Legrand/Havells)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Single pole
Double pole (L&T /Legrand/Havells)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Wiring to 2 X 5 A pin 6 Amps modular plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Havells or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including two nos 5 pin 6A Modular type (2M) type plug socket and two nos 6 Amps modular(1M) switch (Legrand/havellls/L&T/Indo asian Glint) or equivalent make as approved by the Deptt.), PVC surface box (6M) switch board with required face plate complete (Legrand/havellls/L&T/Indo asian Glint) with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere.
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conducto U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 150.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.35/36 KA 415V 50 Hz 3P MCCB (ABB(S6) , Schneider, legrand, Siemens, L&T D-shine make) 250 A (L&T /Legrand/Havells)
Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
Sib Shakti Electricals
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .