₹43.8 L
EMD Value
₹87,500
Closing Date
25 Oct 2022, 6:00 pmClosed
GE (NORTH) TEZPUR
GE (NORTH) TEZPUR, C/O 99 APO
SPECIAL REPAIR TO BLDG NO T-05, T-12, T-30 AND T-31 AT AGE CHARDUAR UNDER GE (NORTH) TAZPUR
2022_MES_554470_1
GE(N)/TEZ/2022-23/8655
Open Tender
Civil Works
Item Rate
180 days
GE (NORTH) TEZPUR
As per tender documents
8 documents required · 8 mandatory
₹500
GE (NORTH) TEZPUR
₹87,500
2 Jan 2023
27 Sept 2022
1 Nov 2022
27 Sept 2022
25 Oct 2022
11 Oct 2022
Amount
Dismantling of Asbestos cement(corrugated, semi corrugated etc.) sheet in roof coverings complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M & L for machine cut Kota stone slab flooring 20 to 25 mm thick over cement screed bed of 15 mm thick in cement mortar 1:3, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M & L for 20 to 25 mm thick machine cut Kota stone in risers of steps, skirting, dado and pillar laid on backing layer of 10 mm thick in cement mortar 1:3, laid and jointed, pointed with grey cement slurry, mixed with pigments to match the sheds including rubbing and polishing complete all as specified and directed.
M & L for screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed.
Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:3 finished even and fair complete all as specified and as directed.
Demolition of wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness including cover fillets of any description including all snap grids and hanging arrangements complete all as specified.
M & L 4 mm thick asbestos cement plain building boards, fixed to timber frame work with screw on walls complete all as specified and directed.
S&F for 6mm thick Cover fillets of standard hard board 40 mm wide and fixing with screws complete all as specified and directed by Engr in charge.
Dismantling wooden boarding, any description, fixed in any position with nails complete all as specified and as directed.
Dismantling timber scantlings in unframed works, 40 sqcm and over in section, in any position
S&F 2nd class Hard wood scanttlings, wrought in any position for framed work jointing wirh nails, screws, nut bolt etc. including necessary supports to existing truss including Dismantling of timber scanttlings 40 Sqcm & over in section, in any position for framed workcomplete all as specified and directed.
Dismantling wooden fillets, rails, posts, rafters, purlins, etc. under 40 sqcm in section in unframed works, in any position
S & F structural timbers of group B, first or second choice as per IS 3629: 1986, planed one side with butt joints in boarding fixed in roofs, ceilings, partitions, fascia, barge, soffit, etc. (except flooring and skirting), 15 mm thick fixed with nails in any situation complete all as specified and as directed.
S & F structural timbers of group B, first or second choice as per IS 3629: 1986, clean sawn with butt joints in boarding fixed in roofs, ceilings, partitions, fascia, barge, soffit, etc. (except flooring and skirting), 25 mm thick fixed with nails in any situation complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water etc, complete all as specified and as directed.
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M & L rendering 5 mm thick in cement plaster in cement mortar (1:4) mixed with integral water proofing compound @3%by wt of cement over 10 mm thick backing coat in cm (1:4) on fair faces of brick work or concrete surface complete all as specified and directed. Note : water proofing compound shall be measured and paid separately).
Supply only integral water proofing compound complete all as specified and as directed.
M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection/paving finish all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats cement base paint over one coat of primer complete all as specified and as directed.
M & L for preparation of old plastered surfaces of wall and applying two coats of cement base paint over alkali resistant priming paintq1a complete all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over putty to match the existing surfaces complete all as specified and as directed
Complete removal of existing treatment of wall and M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over 3 mm thick wall care putty to match the surfaces complete all as specified and as directed
M & L for preparation of old painted wood or wooden surfaces, of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Taking down and refixing in same opening wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
Taking down and refixing in same opening wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed
S & F flush door shutters, 35 mm thick, solid core of block boards construction, MR grade, commercial type with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood of type I as per IS 1328: 1996, internally lipped complete all as specified and as directed.
S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F 75 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 125 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 125 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
Supply & fix sheet glass, ordinary quality, 4 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge.
Dismantling of wrought or mild steel work of any description such as in ladder work, bracing/supporting agle iron, roof top MS sheets, railings etc.
S & F for steel work of grade-3 as per IS 10748 in tubular trusses including special shaped washer etc. complete using ERW or HRIW welded tubes conforming to IS 1161: 2014 (Yst 240 Grade) complete all as specified and directed.
Supply and fixing mild steel plates, plain or chequered, 5 mm thick or over in thickness in available sizes of grade E 250 quality C conforming to IS 2062: 2011
S & F mild steel screw bolts (machine made), diameter of neck 5 to 10 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5 cm but not exceeding 10 cm long complete all as specified and as directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
Preparation of old or previously untreated steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge.
Taking down plastering on lathing (other than wire-netting), without removing lathing, in cement lime or cement mortar (one side only measured in cases where both sides are plastered) complete all as specified and as directed.
S & F GI wire netting 0.90 mm dia and 13 mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified and as directed.
Material and labour for plastering 10 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed.
M & L for 20 mm thick machine cut granite tiles (any type) bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with granite stone shade laid over and including 20 mm thick screed in cement mortar 1:4 and grinding and polishing complete all as specified and as directed.
M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed.
S & F in repairs galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised steel wire staples complete all as specified and as directed.
Applying evenly a coat of blown type bitumen of grade 85/25 at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cum per sqm complete all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer complete all as specified and as directed
S & F flush door shutters, 35 mm thick, solid core of particle board construction, FAT-I or XPS designation, bonded with BWR adhesive with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed.
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
S & F ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed by the Engineer-in-Charge.
S & F 20 mm nominal size, screw down stop valves, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed.
Supplying and laying CPVC pipes for potable hot and cold water distribution, nominal size 16 mm, pressure class 1, SDR 11 including plain CPVC fittings of pressure class 1, SDR 11 in trenches complete all as specified and as directed.
Supplying and laying CPVC pipes for potable hot and cold water distribution, nominal size 20 mm, pressure class 1, SDR 11 including plain CPVC fittings of pressure class 1, SDR 11 in trenches complete all as specified and as directed.
Cutting chases in brick walls to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., exceeding 10 cm but not exceeding 20 cm girth and making good the same with cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate or cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 complete all as specified and as directed.
M & L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
S & F wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
S & F vitreous china squatting pan, 'Orissa" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S' trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
S & F vitreous china urinals, bowl (angle back) without flushing rim of size 465 mm X 355 mm X 265 mm with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and as directed.
S & F 15 mm nominal size, screw down bib taps, cast copper alloy body and body components with crutch handle, nickel-chromium plated finished complete all as specified and as directed.
S & F 15 mm nominal size, pillar taps, cast copper alloy body and body components with capstan heads, spindle, washer plate and nut, with screwed shanks and back nut, with or without lettered hot or cold, nickel-chromium plated finish complete all as specified and as directed.
S & F 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F towel rail 600 mm long of PTMT fixed with and including chromium plated brass screw and wooden/plastics cleats, minimum weight 190 gms complete all as specified and as directed.
S & F brass chromium plated toilet paper holder complete all as directed by EIC complete all as specified and directed.
M & L for PVC connections 15 mm size with PTMT nuts of length 300/450 mm complete all as specified and as directed.
S & F 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
Supply and fix PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed by Engineer in charge.
S & F grating doom 100 mm dia of PTMT (Minimum weight 25 gms) complete all as specified and as directed.
M & L for PVC (SWR ) gully trap 125/110 mm with grating or without grating and jointing with solvent cement and fixed in position complete all as specified and directed including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for concrete bed to drain pipes of internal diameter 150 mm, in cement concrete M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including packing under and haunching against the sides of pipes complete all as specified and as directed.
S & F PVC (SWR), type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 75 mm dia, fixed to walls complete all as specified and as directed.
S & F PVC (SWR), type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches complete all as specified and directed.
S & F PVC (SWR) bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed.
S & F PVC (SWR) Tee(87.5⁰) single, 75 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and as directed.
S & F PVC (SWR) bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed.
S & F PVC (SWR), type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 110 mm dia, fixed to walls complete all as specified and as directed.
S & F PVC (SWR), type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches complete all as specified and directed.
S & F PVC (SWR) Tee(87.5⁰) single, 110 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and directed.
S & F PVC (SWR) vent cowl, 110 mm dia conforming to IS 14735: 1999 complete all as specified and as directed.
Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed by Engineer in charge.
Providing and fixing 30 mm thick factory made solid panel PVC door shutter as per IS 15931: 2012 with 19 gauge thickness mild steel tube and tapering 20 mm in 45⁰ angle on both sides forming styles and on the inner side to form top and bottom rail and on both sides to form lock rail complete all as specified and as directed.
S & F butt hinges, extruded aluminium alloy with galvanised mild steel wire pin, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, hinge designation 150A22 as per IS 205: 1992 complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
Cutting galvanised mild steel pipe of nominal bore 40 mm or 50 mm for alterations or additions (each cut measured) complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M & L for cement concrete in surface channels and drains in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and as directed.
M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 75 mm thick finished even and smooth using extra cement complete all as specified and directed.
Material and labour for spike rolling to surface or making impressions of expanded metal, whilst the concrete is green complete all as specfied and directed
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed.
M&L Non-skid joint free coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceding 0.11sqm but not exceeding 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as directed.
M&L coloured glazed ceramic tiles 200x 300x7 mm thick, in vertical surfaces, skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 5 Amps switch socket combination outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket socket combination outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. (Cat No. AHESXXW061 of make Havells REO or equivalent in Anchor/Legrand)
S & F switch socket combination with (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 6 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F switch socket combination with (3 pin and 3 pin) having two earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed.
S&F in replacement of 10 watt LED new adore 10WB22 cool day light ball lamp complete all as specified and directed.
S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver type 20 watt 6000K 4 feet complete all as specified and as directed.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 4 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. (Cat No. LTSD04M of make L&T or equivalent in Schineder/Legrand)
S&F MCB SP 6-32 amps B series, single pole and neutral 10KA, 240V rating, to be housed in DBs catered here in before complete all as specified and as directed. (Make : L&T Cat No. BB20400C, Schneider, ABB, Havells or equivalent)
S&F MCB SP 240 volts 6 to32 Amps, 10 KA breaking capacity, ’C’ Curve including connection with suitable size aluminum/copper lugs complete all as specified and directed by Engr-In-charge. (Make: - L&T Cat no-BB10320C, BB10100C, BB10060C, Schneider, ABB, Havells or equivalent)
Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories and fixed on walls and 2.5 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 4 sqmm cable, one run of 2.5 sqmm cable and one run of casing/capping shall be measured and paid as one unit length. Cost of cutting chase and making good shall be included in the quoted rate.
S & F in repair fan hook made of mild steel of existing size for mounting ceiling fan of any size complete all as specified and directed.
M & L for house service bracket (hook type complete with 3.0 m long galvanised iron pipe 40 mm dia medium grade, two Nos 900 bends mild steel hook and stay or guy complete all as specified and as directed.
S & F exhaust fan, AC, 50 Hz, single phase, 230 V, 380 mm sweep, 4 pole, heavy duty, metal body, 4 Nos blades, Insulation Class A, ISI marked including capacitor to ensure power factor more than 0.9 including louvers complete all as specified and as directed.
Supply,fixing and connecting new generation energy saving environment friendly long life LED street light made up of pressure die cast aluminium housing with high power LEDs as light source and lens embedded PC cover with IP-66 protection and impact resistance of IK07 having 45 watt 5700K LED with prewired and necessary mounting GI bracket and making necessary electrical connection complete all as specified and directed.
Supplying and fixing PVC insulated cable for working voltages of 1100 V, PVC sheathed, unarmoured, 2 core, flat or circular nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 1554(Part-I): 1988 including cable glands, lugs etc. to suit the cable in service connections suspended by insulating hangers not more than 1 metre apart including 4 sqmm suspension wire and taking down complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Supply and Fix 25x4mm GI strip earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as directed including taking down of old unserviceable existing system.
S & F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50 mm height, 65 mm dia for 550 volts grade complete all as specified and as directed.
Supply and fix Air termination (vertical conductor), single pointed aluminium rod 12 mm dia and 300 mm long including suitable design of fixing components of gun metal as per fig 30 of IS 2309: 1989 all as specified and as directed.
S & F exhaust fan, AC, 50 Hz, single phase, 230 V, 300 mm sweep, 4 pole, heavy duty, metal body, 4 Nos blades, Insulation Class A, ISI marked including capacitor to ensure power factor more than 0.9 including louvers complete all as specified and as directed.
S & F ceiling fan, AC, 50 Hz, single phase, 230 V, 1200 mm sweep, 1350 rpm, 3 Nos metal blades protected with corrosion resistance paints, class I type with double insulation, including capacitor to ensure power factor more than 0.9, complete all as specified and directed by Engineer-in-charge.
Taking down ceiling fan 1200/1400 mm sweep / exhaust fans including disconnection of electric connection, dismantling blades and removing fan and blades to store complete all as specified and as directed.
S&F bracket for street light fitting fabricated with 1200mm long and 40mm bore medium grade GI pipe bent to shape as required and fixed in positon including necessary clamps, nuts, bolts & washer complete all as specified and directed.
Supply and fix LED street light 15 watt new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic driver. Make: Havells cat part LHETAXU7IN6W015/Bajaj/Philips/Crompton.
Supplying and fixing PVC insulated cable for working voltages of 1100 V, PVC sheathed, unarmoured, 2 core, flat or circular nominal cross sectional area of main conductor 6 sqmm, stranded aluminium conductor, ISI marked as per IS 1554(Part-I): 1988 including cable glands, lugs etc. to suit the cable in service connections suspended by insulating hangers not more than 1 metre apart including 4 sqmm suspension wire complete all as specified and as directed.
M/S IMRAN ALI
DRISTEE ASSOCIATES
M/s Brahamaputra Wood Industries
M/S Bishwanath Mahato
M/S SONITPUR BUILDERS
Anil Kumar Sarmah
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .