Tender Value
Refer Docs
EMD Value
₹95,000
Closing Date
11 Jan 2021, 6:00 pmClosed
GE IMA DEHRADUN
GE IMA DEHRADUN
SPECIAL REPAIR TO BLDG NO P-58 SPECIAL REPAIR TO SEWAGE LINE SEPTIC TANK AND SOAKAGE WELL IN BAND LINE PROVN OF TILLING IN PHYSICS LAB PROVN OF HARDSTADING NEAR CHETWOOD BLDG AND CERTAIN MINOR WORK AT IMA DEHRADUN
2020_MES_401869_1
GE/IMA/79/2020-21 9026/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE IMA DEHRADUN
Refer NIT
8 documents required · 8 mandatory
₹500
Yes
GE IMA DEHRADUN
₹95,000
Yes
28 Jan 2021
8 Dec 2020
13 Jan 2021
9 Dec 2020
11 Jan 2021
23 Dec 2020
Amount
Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (below or above) ground level complete all as specified and directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frames) area exc 1.5 Sqm but n.exc 4.0 Sqm each including opening of joints of brick work or masonary for taking out old hold fast and cleaning,pinning and making good the existing hold fast complete all as specified and directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frames) area n.exc 1.50 Sqm each including opening of joints of brick work or masonary for taking out old hold fast and cleaning,pinning and making good the existing hold fast complete all as specified and directed.
Taking down shutters of any description.exc 1 Sqm and n.exc 2 sqm each complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n' exc. 1.5 m in depth and getting out in any type of soil complete all as specified and directed.
Excavation in trenches exc 1.5m wide and n.exc 3.00m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and and getting out in any type of soil complete all as specified and directed.
Excavation in post holes each n.exc 0.5 cum and getting out returning, filling in and ramming earth or broken rubble mixed with earth around in layers watering & removing surplus soil to a distance n.exc 50m & making good surface in any type soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in soil complete all as specified and directed.
Removing surplus excavated soil to a distance n.exc 50 metre & depositing where directed at a level n.exc 1.5 metre above the starting point complete all as specified and directed
PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation filling, mass concrete and sub base of floor etc including demolition of existing old cement concrete complete all as specified and directed.
PCC 1:5:10 type E-2 using 40mm graded crushed stone aggregate as in foundation filling, mass concrete and sub base of floor etcincluding demolition of existing old cement concrete complete all as specified and directed.
PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation filling, mass concrete and sub base of floor etcincluding demolition of existing old cement concrete complete all as specified and directed
PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in coping, benching, cills, PCC gola, holdfast and the like including weathering, slightly rounded or chamfered angles and throating, including necessary from work etc complete all as specified and directed.
RCC M-25 , using 20mm graded crushed stone aggregate as in beams, cantilever bressummers lintel over 1.5 m span etc including demolition of existing old RCC complete all as specified and directed.
RCC M-25 using 20mm graded crushed stone aggregate as in slab supported on walls beams and columns in floor, roof, landing and in shelves and the like including demolition of existing old RCC complete all as specified and directed
Brick work with fly ash’ bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:6) including demolition of existing old brick work built in cement mortar complete all as specified and directed.
Brick work with fly ash’ bricks , straight or curved on plan to any radius in half brick thick walls built in CM 1:4 including demolition of existing old brick work built in cement mortar complete all as specified and directed complete all as specified and directed.
Use and waste of formwork to sides and soffits of floors or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports etc. and similar work of fair finished flat surface of concrete complete all as specified and directed.
Use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick for fair finish surface complete all as specified and directed.
2nd class hard wood (SAL) as in wooden scantling clean swan including dismantling of old scantling complete all as specified and directed.
35mm thick 2nd class H.W. factory made plain framed panelled shutters (any number of panel) with lock rail and panel of 12 mm thick BWR grade veneered particle board medium density wood particle board with commercial face veneers size of members as specified in clause 8.20 (a) of MES schedule Part-1 Section -8 complete all as specified and directed
35mm thick 2nd class H.W. factory made glazed and skeleton door shutter, open rebated and prepared to receive glass, gauge etc (with out sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass/gauze etc, sizes of members of shutters as specified in SSR part I section 8 clause 8.24 (a) complete all as specified and directed.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube & edges will be painted to match with printed sheets complete all as specified and directed.
Factory made solid panel PVC door shutter 30mm thick(style) consisting of frame made out of MS tubes for top & bottom rails ms frame shall be covered with heat moulded plain colour PVC "C" channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side and as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement suppling & fixing in the frame at site as per specification & drawing in SSR etc complete all as specified and directed.
150 mm long aluminium anodised barrel tower bolt extruded section complete all as specified and directed
Extruded aluminium alloy handle 150 mm long fabricated type anodised complete all as specified and directed
250mm long aluminium anosized sliding door bolt with hasp staple (bolt type) and fixing clips to sheet cast or extruded section of cast aluminium complete all as specified and directed
Extruded aluminium alloy handle 100 mm long fabricated type anodised complete all as specified and directed
Mild steel 300mm ordinary rat tail rod pattern spring including roller and roller plate complete and necessary welding to frame as required at site complete all as specified and directed.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
Butt hinges, 100 mm long, medium weight, cold rolled, mild steel and fixed to frame including necessary welding if required complete all as specified and directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
Mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild steel TMT bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Mild steel works as in bands, straps, hold fast, wall/wind ties, angle cleats cross arms bracing and similar articles with and including two coats of synthetic enamle paint over a coat of redoxide primer etc complete all as specified and directed
Milled steel framed brackets of angles ore tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles, as necessary gusset plates riveting etc exc 10 kg each bracket over 10 kg each to be measured under Structual steel complete all as specified and directed
Mild steel framed work such as grills, grating etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing framed work of water tanks and similar work including pintal hinges, stops hand made sliding bolts etc complete all as specified and directed.
Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
Rolled mild steel in roof trusses (framed), trussed, purlin crane gantries, rails and fastenings etc including distance pieces plates cleats etc complete all as specified and directed.
Steel window factory made with side hung shutter including projecting type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded including cutting holes in wall for inserting holdfast and making good the dismantled portion in cm 1;3 or cement concrete 1;2: 4 as required as per TD Drg No TD032 sh 1/10 to 10/10complete all as specified and directed.
Steel window factory made with side hung shutter including projecting type hinges with steel handle and steel peg stay complete with out glazing bars dovetailed or welded including cutting holes in wall for inserting holdfast and making good the dismantled portion in cm 1;3 or cement concrete 1;2: 4 as required as per TD Drg No TD 032 sh 1/10 to 10/10 complete all as specified and directed.
Pre- painted galvalume aluminium Zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc including dismantling existing sheet complete all as specified and directed.
Pre- painted galvalume aluminium Zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge etc fixed with self tapping screws including dismantling existing sheet complete all as specified and directed.
600x600mmx4mm thick 'E' board classic factory finish as in false ceiling including supply and fixing 'Tee" grid frame work made of special section of MS galvanized sheet 0.30mm thick, bottom portion painted with cellular nitro painting, consisting angle cleats of size 25mm wide 1.6mm thick with flange fixed to RCC/CGI roofing with dash fastener or wraping the suspending wire around the existing wooden/steel purlin/rafter for suspending grid frame work of size 605mmx605mm suspended with 02 Nos, 1.60mm dia GI wire @ 600mm C/C on main Tee and fixed to T-grid with the help of level clip or as per manufacturer direction. The section consisting of main Tee 36.5 mm x25mmx1.40mm thick, cross runner tee 23.5mm x26.5 mmx1.4 mm and perimeter angle 40mmx 25mmx2.0 mm thick shall be fixed to wall with GI screw of 40mm long @ 450mm C/C along the perimeter of wall all as per manufacturer's instruction and including taking down existing boards complete all as specified and directed.
Vitrified ceramic jointless tiles light shade 10 mm thick (square/ rectangular) polished, area of each tile exc 0.18 Sqm but not exceeding 0.36 sqm, as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including 15 mm thick screed bed or bedding layer in CM 1:4 complete all as specdified and directed.
Vitrified ceramic jointless tiles Light shade 10 mm thick (square/ rectangular) polished, cut to size as required, as in vertical surfaces such as dado, skirting, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including 10 mm thick rendering in cement mortar 1:4 finished rough to receive tiles complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including laying of 15 mm thick screed bed or bedding layer in CM 1:6 including dismantling of existing wall tiling and removing rubbish off the premises complete specified and directed.
Glazed ceramic coloured tiles of size 300 mm x 200 mm x 7mm thick, as in vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tile with and including 10 mm thick rendering in cement mortar 1:4 finished rough including dismantling of existing wall tiling and removing rubbish off the premises complete specified and directed.complete all as specified and directed
25mm thick PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in floors and finishing the concrete surface fair and rough complete all as specified and directed
100 mm thick PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregate as in flooring finished even and smooth without using extra cement including demolition of existing old concrete complete all as specified and directed
Granite stone 12-16 mm thick machine cut, in cooking plateform and including 15 mm thick screeding in CM (1;4) and jointed with grey cement slurry, and pointed in white cement with admixture of pigment to match with shade of granite stone including grinding and polishing including dismantling old existing stone slabe complete all as specified and directed
Machine cut kota stone slab flooring 18-20mm thick over and including 20mm thick cement sand screed in CM (1:6) as base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and polishing including dismantling old existing stone slabe complete all as specified and directed
Machine cut Kota stone slab 18-20 mm thick as in riser of steps, skirting, dado and pillars etc laid over and including 15 mm backing coat in CM 1:4 on brick or concrete surface base and jointed with grey cement slurry mixed with pigment to match the shade of slab including grinding, rubbing and polishing etc including dismantling old existing stone slabe complete all as specified and directed.
Rendering 15mm thick plaster on fair faces of block/brick masonary or concrete surface in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick plaster on other than faces of block/brick masonary or concrete surface in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed
Rendering 10mm thick plaster on fair faces of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement and mixed with water proofing compound as per manufactures instructions, (work to be carried upto 7.5 Mtr height) complete all as specified and directed. Note- WPC will be measured paid as supply only under respective items separetely
Preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of snowcem (cement base paint) over a coat of cement primer on walls complete all as specified and directed.
Preparation of old plastered surfaces of wall and applying one coats of snowcem (cement base paint) on walls complete all as specified and directed.
Complete removal of existing treatment of walls and applying two coats of oil emulsion distemper over a coat of primer over a coat of wall putty complete all as specified and directed
Preparation of new plastered or unplastered surface of wall and apply three coat of white wash complete all as specified and directed.
3 mm thick sheet glass, ordinary quality and glazing with oil putty or fixed with wooden beads in squares not exc 0.5 Sqm in each pane complete all as specified and directed.
Preparation of new woodensurfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
Preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Vitreous china wash down water closet pan (pedestal pattern) white including seat cover of plastic, CP jet and pipe etc complete including necessary PVC pipe fittings complete all as specified and directed.
PVC low level flushing cistern 10 Ltr capacity symphonic action type white including ball valve, float valve and handle including bracket and PVC flush pipe fixed in repair complete all as specified and directed.
Vitreous china squatting pan 'Orissa' pattern water closet pan of size 580 x 440 mm white, with integral foot rests including connection to trap, and to flushing pipe, anti-syphonage pipe, and concrete bedding etc. fixed in repair complete all as specified and directed
110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenches with MS clamp etc fixed in repair complete all as specified and directed
PVC (SWR) bends any radius 110mm bore fixed in repair complete all as specified and directed
110mm dia PVC (SWR) sanitary short connection socket to fit WC outlet fixed in repair complete all as specified and directed
PVC conections 15mm size with PTMT nuts of 450 mm long fixed in repair complete all as specified and directed
500 Litres capacity rotational moulded polyethylene water storage tanks, three layered, ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including 20mm dia GI light grade washout pipe 50mm long with plug and 20mm dia GI light grade over flow pipe 600mm long with fitting including dismantling existing old tank complete all as specified and directed.
Ball valve 20mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball min weight 210 gms fixed in repair complete all as specified and directed.
15mm bore PTMT bib tap screwed for iron pipe or for brass ferrule and fixed(min weight 90 gms) complete all as specified and directed
15mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc including taking down old tubing complete all as specified and directed.
20 mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc including taking down old tubing complete all as specified and directed.
15mm bore long body bib tap chromium plated with wall flange and aerator fixed in repair complete all as specified and directed. Make- Jaguar ESSCO cat part No SQT-512 KN or equivalent of Cera/Hindware
15mm bore stop valve chromium plated male end screwed both end for iron pipe fixed complete all as specified and directed. Make- Jaguar ESSCO cat part No SQT-513A or equivalent of cera/Hindware
75 mm cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded crushed stone aggregate complete all as specified and directed
100 mm cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded crushed stone aggregate complete all as specified and directed.
Sink made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement morter on to dwarf wall or inclulding fixing cantilver brackets and connecting union to pipe overall size 405mm x 460mm x 203 mm bowl size 405 mm x354mm x 203mm fixed in repair complete all as specified and directed. Make:- Prayag Cat part No.1216DM or equivalent in Blue star/Nirali.
150 mm bore, salt glazed stone were (SGSW) drain pipe, grade 'A', laid to slope in trenches and jointed in cement mortar 1:1 including necessary testing including demolition and breaking up drain complete all as specified and directed.
PCC 1:4 ;8 type D-2 using 40mm graded crushed stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested suitable for 150mm bore of pipe complete all as directed.
200 mm bore, salt glazed stone were (SGSW) drain pipe, grade 'A', laid to slope in trenches and jointed in cement mortar 1:1 including necessary testing including demolition and breaking up drain pipe complete all as specified and directed.
PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested suitable for 200mm bore of pipe complete all as directed.
300 mm bore, reinforced concrete pipe class NP-3 laid and jointed with collars laid to slope in trenches and jointed in cement mortar 1:1 including necessary testing including demolition of existing pipe complete all as specified and directed.
PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested suitable for 300mm bore of pipe complete all as directed.
Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends etc complete all as specified and directed.
Supply only waterproofing compound complete all as specified and directed.
Brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in cement mortar (1; 4) including dimolition of existing brick work built in cement mortar complete all as specified and directed.
Brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:6) including dimolition of existing brick work built in cement mortar complete all as specified and directed.
PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) as in coping, benching, cills, PCC gola, PCC block for holdfast and the like including weathering, slightly rounded or chamfered angles and throating, including necessary from work etc complete all as specified and directed.
Pre-cast RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in cover slabs (for manhole, drain etc) and simililar articles with plain faces including necessary form work and including demolition of existing cover slab etc, set in cement mortar 1:4 complete all as specified and directed. (Note: Reinforcement shall be measured and paid separately under respective items of BOQ)
Preparing steel surfaces and treating small articles such as hold fast etc area n. exc 0.1 Sqm each and treated with tar or coal tar black paint complete all as directed.
Construction of septic tank suitable for 200 users, excavation in any type of soil, foundation in PCC 1:2:4 type B-2, brick work in CM 1:4, internal plaster 12mm thick in CM 1:3 mixed with water proofing compound, external and bearing plaster shall be 15mm thick in CM 1:4, RCC slab in M-25 design mix concrete including RCC precast manhole cover reinforced with 8mm dia bars with angle iron frame, vent shaft and sludge chambers etc complete all as specified and shown on Drg TD brick-217 sheet 1/7 to 7/7.
Construction of soakage well of size 3.00 M dia X 6.00 M deep, excavation in any type of soil, foundation in PCC 1:3:6 type C-2, walls of honey combed and solid in M-25 (design mix) concrete, including intercepting chamber, screen chamber, brick work in CM 1:4, plaster where shown on drg shall be 12mm thick in CM 1:6, bearing plaster 15mm thick in CM 1:4, RCC cover slab In M-25, filling with brick bats of gauge 80 to 150mm complete all as specified and shown Drg TD-309 sheet 1/4 to 4/4
Machine pressed precast coloured concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-30 Grade laid, jointed and pointed in grey cement with pigment to match the shade of tile with and including 25mm thick sand cushioning layer etc complete all as specified and directed.
Taking down carefully existing aluminum/copper surface/concealed point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and removing material from site for offring schedule of credit except fans etc which shall be re-used in work and making good the disturbed surfaces in CM 1:3 of walls, floors, ceiling etc including distempering to match with existing surfaces complete all as specified and directed
Supply and laying or fixing or passing through pipe XLPE insulated, armoured, heavy duty electric cables 1100 volts grade with stranded aluminum conductor of size 25 sqmm 4core including taking down existing old cable complete all as specified and directed.
Point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLS having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area drawn in and including concealed non metallic rigid PVC conduit 25mm dia or higher with all fitting and fixing accessories and 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes 1.6mm thick, 60mm deep of required size factory made for mounting switch, regulators etc with and including 3mm thick plastic hylam laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches, sockets etc complete for the following:- Note:- (i) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs. (ii) Point wiring & earth wire shall be connected to each & every sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
One light point controlled by one, one way 6 Amp switchs.
One fan/exhaust fan point controlled by one, one way 6 Amp switch.
One 5 pin 5/6 Amps socket outlet point on the same board with other switch.
One 5 pin 5/6 Amps socket outlet point on independent board controlled by one, one way switch.
One bell point controlled by one, one way 6 Amp button switch.
Description all as per item No 102 here in before but point wiring with 2.5 sqmm multistrand copper conductor cable for one 5 pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm PVC insulated multi strand copper conductor cable as continous earth wire.
Switch piano, flush type, single pole one way, 5 Amp complete all specified and as directed
Switch piano, flush type, single pole one way, 15 Amp complete all specified and as directed
Bell push flush type, 5 Amps complete all specified and as directed
Socket outlet, multipurpose, 2 in 1, 5 pin, 5 Amp complete all specified and as directed
Socket outlet, multipurpose, 2 in 1, 5 pin, 15 Amp complete all specified and as directed
Electronic step rotary type fan regulator 100W 230 volts AC 50Hz complete all as specified and directed
Electronic step rotary type fan regulator 100W 230 volts AC 50Hz fixed in repair complete all as specified and directed
Ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate /isolated body complete all as specified and directed
Lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Extruded Aluminium batten for continuous operation and available in 4 ft run length, suitable for Surface, Wall & Condutit mounting (With accessories) 40 Watt high brightness LED's and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to walls including taking down existing fitting complete all as specified and directed Make- Philips cat part NO BN100C LED40S -6500 PSU L120 GR or equivalent to Havells/ Wipro
Environmental friendly, ultra modern, energy saving surface mounted decorative oval bulk head edge-lit LED luminare comprising and including 10 Watt high brightness LED's and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to walls including taking down existing fitting complete all as specified and directed. Make: Havells Cat part No. RUGBYNEONFT10WLED860SSYMTOPC or equivalent to Philips/Wipro
Ceiling Fan 1200 mm sweep, with electronic type regulator and accessories 5 star rated and connecting up including provision of cable from ceiling rose to fan, fixed in repair complete all as specified and directed Make- Havels Model No ES-50 Premix or equivalent of Bajaj//Usha
Ceiling fan 1200 mm sweep, with electronic type regulator and accessories 5 star rated and connecting up including provision of cable from ceiling rose to fan, complete all as specified and directed Make- Havels Model No ES-50 Premix or equivalent of Bajaj//Usha
Sub main wiring with two single core PVC insulated unsheathed FR cable 1100 Volt grade, 6.0 Sqmm size with multi stranded copper conductor drawing into and including conduit in surface/concealed as required including one run single core PVC insulated unsheathed 6.0 Sqmm cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB including taking down and unserviceable sub main wiring complete all as specified and directed. NOTE: (i) Two run of 6 sqmm cable , one run 6.0 sqmm cable and one run PVC conduit will be measured as one unit.
Sub main wiring with two single core PVC insulated unsheathed FR cable 1100 Volt grade, 4 Sqmm size with multi stranded copper conductor drawing into and including conduit in surface/concealed as required including one run single core PVC insulated unsheathed 4Sqmm cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB complete all as specified and directed. Make of wire : Finolex, Plaza, Havells, Polycab NOTE: (i) Two run of 2.50 sqmm cable , one run 2.50 sqmm cable and one run PVC conduit will be measured as one unit.
MCB DB, sheet metal enclosures double door SPN 4 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter (METAL DOOR) type with blanking plates where required and IP 43 degree protection fixed in repair complete all as specified and directed.
Distribution boards epoxy powder coated TP & N 8 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 250 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one FP-MCCB 100/125 Amps as incomer and 24 SP MCBs or 4/8/ 12 TP MCBs (or any combination of SP/TP MCBs) outgoings complete including disconnecting and taking down existing DB complete all as specified and directed. Make : Legrand CAT PART No 507750 or equivalent of, L&T, ABB, Schneider. Note- Suitable MCCB and outgoing MCB's will be mearued and paid separately under relevent item of this schedule
MCB SPN 63 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete all as specified and directed
MCB TPN 40 to 63 Amps, 415 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete all as specified and directed .
LED ball lamp 15 watt suitable for angle holder pendant fitting complete all as specified and directed.
MCCB, 125 Amps, 4 pole, 415 volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting having including taking out existing unserviceable MCCB complete all as specified and directed.
Sheet metal enclosure, single pole and neutral with two pin and earth plug and socket with and including one single pole MCB 20 Amps, 240 volts,10 KA complete all as specified and directed.
MCB SP 6 to 32 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete all as specified and directed
Un-reinforced precast concrete cable cover class LV type1 flat size250 mmx 150 mm x40 mm as protection to under ground cable laid dry flat adjjoining each other complete all as specified and directed.
Supply and filling sand with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. NOTE: - Punned thickness shall be measurement & paid.
GI pipe light grade ISI marked 40mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah with calmps, bolts, nuts & washers etc fixed in repair complete all as specified and directed.
Water heater (Geyser) storage type, electric,capacity 25 litres.five star rated AC SP 230 volts, 50 Hz, vertical mount type, shockproof and rustproof metal body, stainless steel inner container, high efficiency heating element, autocut thermostate, pressure release safety system, fire retardent cable with 3 pin plug top, white colour including fixing accessories like fastensers, nuts, washers complete all as specified and directed. Make: Havells cat part No. GHWAMGTWH025or equivalent in Bajaj/Usha/Recold
Earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI light grade earth lead protection pipe etc complete all as specified and directed. NOTE: (i) Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted. (iii) If the desired earth resistance is not found within permissible limit shall be re done by contractor at no extra cost.
M/s Vinod Singh Negi
ACE BUILDERS AND CONTRACTORS
M/S RAJESH KUMAR GOYAL
JAIN BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .