Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 CrAdmitted-Finance | ₹13.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹13.9 CrAdmitted-Finance | ₹13.9 Cr | L2 | Admitted-Finance |
| 3 | L3₹14.4 CrAdmitted-Finance | ₹14.4 Cr | L3 | Admitted-Finance |
| 4 | L4₹15.6 CrAdmitted-Finance 101 DDA MARKET PHASE III PKT B ASHOK VIHAR NORTH WEST DELHI 110052 | NORTH WEST | DELHI | 110052 | ₹15.6 Cr | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M.C Construction Company L4 | SATISH BUILDERS L3 | S K Integrated Consultants L2 | KALYAN CHANDRA GOYAL AND COMPANY L1 |
|---|---|---|---|---|---|---|---|
| 1.00Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge | |||||||
| 2.00 | All kinds of soil | 2,004.83 | CUM | 2,50,603.75 ₹3.0 L | 3,00,724.5 ₹3.0 L | 3,90,941.85 ₹3.9 L | 4,00,966 ₹4.0 L |
| 3.00Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. | |||||||
| 4.00 | All kinds of soil | 2,004.83 | CUM | 2,10,507.15 ₹2.5 L | 1,00,241.5 ₹1.0 L | 1,94,468.51 ₹1.9 L | 2,00,483 ₹2.0 L |
| 5.00Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : | |||||||
| 6.00 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural
sources : 8 graded stone aggregate 40 mm nominal size
derived from natural sources) | 91.37 | CUM | 4,93,398 ₹5.8 L | 3,65,480 ₹3.7 L | 5,42,280.95 ₹5.4 L | 5,48,220 ₹5.5 L |
| 7.00 | Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up
to 50 m and lift upto 1.5 m. | 1,281.19 | CUM | 1,92,178.5 ₹2.3 L | 64,059.5 ₹64,059.50 | 3,07,485.6 ₹3.1 L | 3,20,297.5 ₹3.2 L |
| 8.00Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. | |||||||
| 9.00All works upto plinth level | |||||||
| 10.00 | Concrete of M35 grade with minimum cement content of 370 kg /cum | 677.78 | CUM | 44,05,570 ₹52.0 L | 61,00,020 ₹61.0 L | 59,30,575 ₹59.3 L | 50,83,350 ₹50.8 L |
Tender Value
₹14.3 Cr
EMD Value
₹28.8 L
Closing Date
4 Jul 2024, 5:00 pmClosed
Principal
PRINCIPAL MATA SUNDRI COLLEGE FOR WOMEN (UNIVERSITY OF DELHI) MATA SUNDRI LANE NEW DELHI-110002
CONSTRUCTION OF GIRLS HOSTEL BUILDING AT MATA SUNDRI COLLGE FOR WOMEN UNIVERSITY OF DELHI
2024_DU_807580_1
MSC/ADMN/325/2024-25/334
Open Tender
Construction Works
720 days
MATA SUNDRI LANE NEW DELHI
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Principal Mata Sundri College for Women
₹28.8 L
MATA SUNDRI COLLEGE FOR WOMEN
7 Aug 2024
16 May 2024
5 Jul 2024
16 May 2024
4 Jul 2024
17 May 2024
24 May 2024
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge
All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level
Concrete of M35 grade with minimum cement content of 370 kg /cum
All works above plinth level upto floor V level
Concrete of M35 grade with minimum cement content of 370 kg/cum
Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for
Suspended floors, roofs, landings, balconies and access platform
Columns, Pillars, Piers, Abutments, Posts and Struts
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :
cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means.
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
CEMENT PLASTER (IN FINE SAND)
12 mm cement plaster of mix :
1:6 (1 cement: 6 fine sand)
1:3 (1 cement : 3 fine sand)
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
25 mm thick
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
Finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Double charge vitrified tile polished finish of size
Size of Tile 600 x 600 mm
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.,complete
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitre and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
35 mm thick
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge),minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Frame size 65 x 150 mm
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in?charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry
Finishing walls with water proofing cement paint of required shade :
New work (Two or more coats applied @ 3.84 kg/10 sqm)
Finishing walls with textured exterior paint of required shade :
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Two Coats
Providing and fixing of GRC (glass fibre jaali) 50mm thick of required size, pattern,design and colour with 50% area covered to be fixed on/Between RCC/ blockwork column or structural steel work with dry fixing method
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
7.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Providing, detailing and fabricating as per specification, transportation to site and erecting MS openable/Sliding/ ornamnetal entrance gate including track and whel, locking arrangement, fixing bolts, nuts, washers,cleats stiffners, gussets decorative balusters, arrow heads, etc all necessary operations like starightening, bending cutting, drilling, grinding , machining if specified, welding etc complete weighing 25 to 30 kg/sqm, including cleaning, grinding and removing the welding burr and prepaing surface and applying one coat of synthetic enamel paint after fabrication and second coat of synthetic enamel paint after erection, with approved colour, shade and brand etc. including touching up with primer etc complete as directed by Engineer in charge
Providing and fixinf toilet cubicle (of followingstandard dimension which includes 600 mm door size width) made of heat, bacteria, water , chemcical, scratch, impact and anti bacterial resistant 12mm thick solid compact laminate panels. Finish of the compact laminate should be rawsilk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (indian standard) and as per fire retardant BS 476/97 standard. This also includes providing and fixing in position necesarry hardware as per manufacturer's specification and EIC instructions like 1) Door knob, 2)Gravity hinges 3) Thumb tum lockset indicators 4) Coat hooks 5)u channels 6)Rubber noise deafening tape 9) screws and wall plugs
Supplying and fixing rollimng shutters of approved make, made of required size M>S laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside with push and pull operation complete, including the cost of providing and fixing necesarry 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 part 1 and MS top cover of required thickness of rolling shutters.
80x1.25mm M.S laths with 1.25 mm thick top cover
Disposal of moorum/building rubbish/malba/similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge
Sanitary Fixtures
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mmsizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, includingpainting of fittings and brackets, cutting and making good the walls wherever required:-
(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
17.10.1 Kitchen sink with drain board
510x1040 mm bowl depth 250 mm
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Flexible pipe
40 mm dia
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge
Providing and fixing brass bib cock of approved quality
15 mm nominal bore
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Rectangular shape 453x357 mm
Providing and fixing toilet paper holder :
C.P. brass
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
15mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing C.P cast brass Double coat hook fixed to PVC cleats with C.P. brass screws complete as per instructions of the engineer-in-charge (Make: Jaquar Cat No: ACN 1161 N or equivalent model of other preferred makes)
Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length 15 mm nominal bore
Providing and fixing brass soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
(a) 15 mm nominal dia
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
150 mm diameter
Providing and fixing brass liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing brass towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Internal Drainage (Rainwater, Soil, Waste & vent Pipes & Fittings)
Providing and fixing Upvc SWR pipes ( Class B Heavy Type) including all fittings (plain or door) e.g. bends, junction, cowls, offsets, access pieces, jointing with rubber ring/solvent cement joints,jali,clamps including cutting chase or holes in walls and floors and making good where required.( Inside the building)
50 mm dia
75 mm dia
110 mm dia
Providing and fixing Upvc SWR pipes Class B Heavy Type) including all fittings (plain or door) e.g. bends, junction, cowls, offsets, access pieces, jointing with rubber ring/solvent cement joints,jali,clamps including cutting chase or holes in walls and floors and making good where required.(in vertical stacks inside the building)
110 mm dia
Providing & fixing in position pipe trap of self cleaning design of following sizes for the embedded areas. Making proper connection with , cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors where required. Make :
P-trap 110 mm dia
Nahani trap 110 mm dia with grating(Outlet 75MM dia)
Floor trap 110 mm Dia with grating(Outlet 75MM dia)
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
Making Tarrace Rain Colletion khurras (slope) Near Rain Water stack 230x230 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size). Complete with Grating Cover
INTERNAL /EXTERNAL Water Supply
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall / Terrace
25 mm nominal dia Pipes
32 mm nominal dia Pipes
40 mm nominal dia Pipes
50 mm nominal dia Pipes
65 mm nominal dia Pipes
80 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
20 mm nominal dia Pipes
25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
32 mm nominal dia Pipes
40 mm nominal dia Pipes
50 mm nominal dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
65 mm nominal bore
80 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end) :
25 mm nominal bore
Vertical
40 mm nominal bore
Horizontal
50 mm nominal bore
Horizontal
Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately).
Providing and fixing 600 mm long MS hot dip galvanized PUDDLE FLANGES fabricated out of 6 mm thick MS plates of suitable size and IS:1239 heavy class pipes properly fixed in walls & top slab of tanks. The entire fittings shall be hot dipped galvanized after fabrication. Length shall be minimum 600 mm or wall thickness plus 200 mm on either side (which ever is more).
32 mm dia (screwed / Flanged Ends AS per Plan)
50 mm dia (screwed / Flanged Ends AS per Plan)
80 mm dia (screwed / Flanged Ends AS per Plan)
100 mm dia (screwed / Flanged Ends AS per Plan)
150 mm dia (screwed / Flanged Ends AS per Plan)
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :
With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
External Sewer/Rain water Drainage
Fixing, jointing and testing in position the following UPVC pipes( 6Kg/sq cm) conforming to IS: 4985 for drainage cut to required lengths including all necessary fittings and specials such as bends, junctions, offsets, making proper connections. Including providing PCC thrust block at 2 mtr. centre to centre. Pipe to be laid below ground level in trenches upto required depth including excavation in all kind of soil, dewatering, refilling, watering, ramming & removing the surplus excavated material and making good the same complete as required.Cost shall include making connection with municipal sewer manhole including all associated civil & cost of all liasion works for getting approval. Make: Supreme
110 mm dia
160 mm dia
200 mm dia
Laying of 150 mm thick cement concrete 1:4:8 (1 cement:4 fine sand:8 graded stone aggregate 40mm nominal size) allround pipes including 100 mm thick bed concrete as per standard design.
110 mm dia
160 mm dia
200 mm dia
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
180x150 mm size P type
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry road gully chamber 50x45x60 cm wit hbricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design
Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes :
Size 90x80 cm
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Rain Water Harvesting
a .Construction of tubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with "code of practice for construction and testing of tubewells with supply of bail plug if necessary. housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemed completed only after obtaining sound free water during pumping 250 mm nominal bore (20Meter) b.Supply & lowering air line of 25mm dia, G.I. pipe 'B' class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. c.Supply and lowering vent air pipe 63mm dia rigid PVC pipe mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. d.Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids Size 9 to 12mm( 6CUM) e.Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. (6CUM)
Size of Harvesting Pit :- 3.5M(L) x 2.4M(W)x3 M Effective Depth
DE-STILTING PIT SIZE-1.2 M(L)X1.2M(W)X1.5 M(D)
PUMPS
SITC of Solar Panels & Heat Pump Combined System. Ambient Cold water inlet to 6 Nos. Solar Panels and after Solar panels water goes to Heat pump. Each Solar panel Size 2M x 1M, capacity 125 Liters. Heat Pump at terrace level 1031 liter/HR Heating Capacity 48KW & INPUT POWER 9.97 KW, MINIMUM COP 4.81 with 3500 liters 4mm thick MS Storage Tank with Glass lining on tanks internal surface . . All kind of work Connections, valves, placements etc included.
Supply Installation testing & Commissioning of ISO certified manufacturer made Pressure boosting pump with 100 Ltr. MSTank, pressure switch, pressure gauge, and all standard fittings fully automatic ON/OFF system, 2900 RPM with stainless steel casing,& impellor suitable for following capacity complete in all respect. Appropriate type test certificate/ OEM test report shall be submitted. All as per pre approved by Engineer in charge
30 Mtr, 6000 LPH
SITC of Hot water Return pump Horizontal Multistage pumpset.
Flow-3500 LPH
Head - 20 mtr
MOC- SS Casing, SS impeller, SS Shaft
2 pole , 3 phase , 1 HP
1W + 1S DOL Timmer base control panel
Location of Pump - Terrace floor
SITC of ISI marked Submersible Cutter pump set minimum 30 mm solid handling 2900 RPM , three phase, 415 V, 50 Hz, having following capacity.
1 HP, ( 8 ) Mtr. (50) LPM
2 pole , three phase , 3.0 HP
Local panel 1W +1S DOL, 2.2 KW with Float switch
SITC of ISI mark( IS:8472) self priming monoblock pump set of approved make, TEFC, permanent split capacitor type (PSC), fitted with thermal overload protection, mechanical seal, 1440/1500 RPM, single phase(180 to 240 V). Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively. The rate will include electrical panel with cyclic operation as supplied by the manufacturers) Panel shall be BMS compatible.
Capacity of 70 lpm against a total Minimum head of 40 m (1 Working + 1 Stand by) for STP Recycale Tank to Over Head Flushing Water Transfer
Providing & Fixing of Single Stage, water cooled, High Speed (2880RPM), Horizontal, Centrifugal , Openwell Submersible pumps set pre filled with coolent water and fitted with mechanical seal-T/CVsT/C, Thrust bearing shall be of carbon+S.S. The stator body of single phase pump shall be of SS and rest of all shall be of cast iron. All casting parts should be cathod electrode position (CED)coated and other construction material should be confirming to IS:14220:2018. The over all performance of pump shall confirm to BEE energy efficiency level of 3star. Valid BEE certificate from OEM must be submitted for the same. Motor should be IE2 class as per IEC60034-2-1:2007, IEC60034-30:2008,& IS12615:2011, including making connection etc as required complete in all respect. All as per preapproved by Engineer incharge.
Capacity of 125 lpm against a total Minimum head of 40 m (1 Working + 1 Stand by) for UGT Tank to Over Head Domestic Water Transfer
FRP Underground Packaged Sewage Treatment Plant of Capacity ENVI-50 KLD & Intermediate (Filter Feed) Tank Cum Treated Water Storage Tank of 25 KL (With Partition)
Supply, Installation and commissioning of Underground Packaged sewage treatment plant based on “MBBR Technology” having: a. FRP tank for Anaerobic, Anoxic, MBBR Media Aeration zone & Final sedimentation zone of size 9.65 m (L) X 2.2 m (dia)- 1 No. b. FRP tank for Intermediate Cum Treated Water Storage Tank (With Partition) of size 4.26 m (L) X 2.2 m (dia)- 1 No. Along with 1 (one) No. Sludge Re-circulation pump (submersible pump), 2 (two) no. Air Blowers, uPVC return sludge pipe 40mm dia, PVC inlet outlet pipe 160mm dia, PVC interconnection pipe of 160mm dia, Control panel, Nylon Belt as per the diameter of the tank, RCC blocks, Manhole cover as per the drawing, uPVC air vent nozzle of dia 50mm, manhole cover of size 600mm dia etc. complete. Note:- Arvind Envisol or equivalent.
Tertiary Treatment Plant - 3.0 Cum/hr
a. Multi Grade Filter Capacity: 3.0 cum/hr; MOC: FRP; Filter Media: Pebbles & Filtering Sand; Piping: PVC – 1 No. b. Activated Carbon Filter Capacity: 3.0 cum/hr; MOC: FRP; Filter Media: Activated Carbon 1200 I/V; Piping: PVC – 1 No. c. Chlorine (Sodium Hypo-Chlorite) Dosing System; Pump Make: E-Dose/Kai/Equiv.; Dosing. Pump: 0-6 LPH; Dosing Drum: 50 Lit (HDPE Drum) 1 No. d. Filter Feed Pump: Make: Lubi/Equiv.; Capacity: 1.0 HP, Type: Non-clog submersible Sewage.
Installation of FRP Underground Package Sewage Treatment Plant and Intermediate & Treated Water Storage tank (with Partition)
VENTILATION WORK
Axial Flow Fan Exhaust Fans - Axial Flow Type Filw rated : 250 deg for 2 Hrs.
Providing, fixing, testing and commissioning of AMCA Certified (For Air and Sound Performance) tube axial flow fan of different capacity as mentioned below in standard M.S.contruction. Entire fan model & AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-2 type) confirming to IS - 325-IP - 55 with class `H' insulation. Motor shall be of high temperature resistance "Class H Smoke Spill" 250° C for 2 hrs. Fan shall be EN 12101-3 Certified & CE/UL Listed for high temprature. Fan efficiency should not be less than 65 %, noise levelof car parking ventilation system shall be 70 dB(A) at 1 meter from the fan room in case of normal operation. Max. fan outlet velocity for Normal mode 10.2 m/sec (2000 fpm). Fan Speed Not more than 1450 RPM.Fans should be as per specification and drawings. All necessary accessories, as below, shall be provided for proper installation: a) Vibration isolators for the axial fans; b) Double canvas connection (of fire retardant material) at the outlets of each fan; c) Acoustic silencers at inlet and outlet of the fan as per manufacturers instructions; and d) Bird screen for the protection from extraneous elements, specially at fresh air intake and at exhaust outlet to outdoor.
Motor make shall be same as mentioned on the fire certificate.
Fresh Air Fans - Axial Flow Type : (Non Fire Rated)
Providing, fixing, testing and commissioning of AMCA Certified (For Air and Sound Performance) tube axial flow fan of different capacity as mentioned below in standard M.S.contruction. Entire fan model & AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-2 type) confirming to IS - 325-IP - 55 with class `F' insulation. Fan efficiency should not be less than 65 %, noise levelof car parking ventilation system shall be 70 dB(A) at 1 meter from the fan room in case of normal operation. Max. fan outlet velocity for Normal mode 10.2 m/sec (2000 fpm). Fan Speed Not more than 1450 RPM.Fans should be as per specification and drawings. All necessary accessories, as below, shall be provided for proper installation: a) Vibration isolators for the axial fans; b) Double canvas connection (of fire retardant material) at the outlets of each fan; c) Acoustic silencers at inlet and outlet of the fan as per manufacturers instructions; and d) Bird screen for the protection from extraneous elements, specially at fresh air intake and at exhaust outlet to outdoor.
Basement-1 & 2 Normal Mode
10000 CFM ESP 25MM (WC)
Pressurization Fans - Axial Flow Type : (Non Fire Rated)
Providing, fixing, testing and commissioning of AMCA Certified (For Air and Sound Performance) tube axial flow fan of different capacity as mentioned below in standard M.S.contruction. Entire fan model & AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-2 type) confirming to IS - 325-IP - 55 with class `F' insulation. Fan efficiency should not be less than 65 %, noise level should not be more than 70 db @ 1 m distance. All necessary accessories, as below, shall be provided for proper installation: a) Vibration isolators for the axial fans; b) Double canvas connection (of fire retardant material) at the outlets of each fan; c) Acoustic silencers at inlet and outlet of the fan as per manufacturers instructions; and d) Bird screen for the protection from extraneous elements, specially at fresh air intake and at exhaust outlet to outdoor.
10500 CFM ESP 20MM(WC) Lift Well Press.
Air Scrubber
Modular Double skin Floor mounted air scrubber units made of 23+2mm thick PUF insulated panels extruded aluminum hollow profiles with 0.8mm thick pre-coated GI Outer Sheet & 0.8mm thick Plain GI (270gsm) inner sheet comprising of Intake section for duct connection, Al Wiremesh filter section, Wet section made of 20g SS Tank, Three Phase Pump (1w+1s), GI internal piping, Single Bank Spray Nozzles and 2bend PVC eliminators. Blower section with DIDW Aerofoil/ Backward/ Forward curved fans, drive set with V- belts, Spring type vibration isolators, wire guard on Fan section access door, fire retardant canvass connection at fan outlet, IE-2 motor (TEFC type & suitable for VFD operation) & LED lamps for blower section, limit switch for the fan section access door with a view port and damper at the outlet of unit. All dampers shall be low leakage aluminum aerofoil design and suitable for manual / motorised operation. Units exposed to open sky shall have weather proof canopy. The End Plates/Casing/blank offs of Eliminators shall also be made of SS.
12000 CFM (65mm of wg Total St. Pressure)
4000 CFM (65mm of wg Total St. Pressure)
Air Washer
Modular Double skin Floor mounted air washer units made of 23+2mm thick PUF insulated panels extruded aluminum hollow profiles with 0.8mm thick pre-coated GI Outer Sheet & 0.8mm thick Plain GI (270gsm) inner sheet comprising of Al Wiremesh filter section, Wet section made of 20g SS Tank, Single Phase Pump (1w+1s), PVC internal piping, Distribution system, 200mm deep Cellulose Pads & 2 bend PVC eliminators. Blower section with DIDW Aerofoil/ Backward/ Forward curved fans, drive set with V- belts, Spring type vibration isolators, wire guard on Fan section access door, fire retardant canvass connection at fan outlet, IE-2 motor (TEFC type & suitable for VFD operation) & LED lamps for blower section, limit switch for the fan section access door with a view port and damper at the outlet of unit. All dampers shall be low leakage aluminum aerofoil design and suitable for manual / motorised operation. Units exposed to open sky shall have weather proof canopy. The End Plates/Casing/blank offs of Pads & Eliminators shall also be made of SS.
3600 CFM (50mm of wg Total St. Pressure)
10000 CFM (50mm of wg Total St. Pressure)
DUCTING, GRILLS, DIFFUSER AND INSULATION
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required
Thickness 0.80 mm (22G) sheet
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required
Thickness 0.80 mm (22G) sheet
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Exhasut Air Grills with louvers but without volume control dampers complete as required.
Supplying & fixing of opposed blade volume control dampers in supply air duct collars as per approved drawings and specifications. Volume control damper shall be provided at the junction of each branch duct with main duct. Dampers shall be 2 gauge heavier than the gauge of large duct but should not be less than 20 gauge, and shall be rigid in construction so as not to flutter with the passage of air.
Supply, installation, testing and balancing of Powder coated/Anodised extruded aluminium construction. inlet air louvers with bird screen and volume damper for fresh air as per specifications and approved shop drawings.
Supply, installation, testing and balancing of Powder coated/Anodised extruded aluminium construction. louvers with bird screen for exhaust air as per specifications and approved drawings.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
THERMAL INSULATION FOR KITCHEN DUCTS
SITC of Glass Fibre Blanket Insulation material bonded with Thrmosetting Resin, with factory applied laminated aluminium foil of 22 micrns with fibre glass backing. Nominal density : 48 Kg/CuM. Thermal conductivity, < 0.033 W/m.K at 24 degreeC. All Insuation material and adhesives shall be as per Class I for surface spread and in accordance with BS 476, & Class O for non-combustible grade.
Supply, installation, testing and commissioning of Ceiling Mounted Exhasut Air fans. Suitable to Connected with duct from discharge side. inbuilt differs/grill at suction side. Fan efficiency should not be less than 70 %, noise level should not be more than 55 db @ 1 m. complete with canvas connection & NRV Damper.
Supply, installation, testing and commissioning of Exhasut/Fresh Air Inline fans. Fan efficiency should not be less than 70 %, noise level should not be more than 60 db @ 1 m. complete with canvas connection.
installation charges for above 1.50 Tr split A/c including 5.0 RMT copper tubing, drain pipe and electrical wiring connection etc complete
WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
Group C
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 10 sq. mm earth wire
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
3 pin 5/6 amp socket outlet
Telephone socket outlet
TV antenna socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
6 Module (200mmX75mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module
3 Module
6 Module
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
510 mm sweep
Supply & drawing of UTP 4 Pair CAT-6 LAN Cable in the exisitng surface/recessed steel/PVC Conduit as required.
1 run of cable
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
MCCB, MCB & DB'S: Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator
8 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
6 way (4 + 18), Single door
8 way (4 + 24), Single door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note :Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
CABLE TRAYS
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 62.5 mm depth X 2.0 mm thickness
600 mm width X 62.5 mm depth X 2.0 mm thickness
750 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required
450 mm width X 62.5 mm depth X 2.0 mm thickness
EARTHING
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal/ coke and salt ) as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
LIGHTNING CONDUCTOR
Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductorcomplete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductorcomplete as required.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
MV CABLE LAYING & SUPPLY
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
90 mm dia (OD-90 mm & ID-76 mm nominal)
Supply, Testing & Cominsioning of XLPE insulated & sheathed cable of 1.1 kV grade with Copper/ Aluminium conductor of approved makeon wall / Cable Tray with GI Saddles ,making necessary connections including testing etc. as required
4.0 Sq.mm 3.0 core Armoured Al. Cable
185.0 Sq.mm 3.5 core Armoured Al. Cable
16.0 Sq.mm 4.0 core Unarmoured Al. Cable
35.00 Sq.mm 4.0 core armoured Al. Cable
10.00 Sq.mm 4.0 core armoured Al. Cable
10.00 Sq.mm 4.0 core unarmoured Al. Cable
MV CABLE JOINTING & END TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 185 sq. mm (57mm)
4 X 10 sq. mm (25mm)
4 X 16 sq. mm (28mm)
4 X 35 sq. mm (28mm)
FIRE ALARM NETWORK
CONVENTIONAL TYPE FIRE ALARM SYSTEM
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDS metac cover complete with all connections etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.
PUBLIC ADDRESS SYSTEM (For Conference Hall, Offices Areas)
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
TELE-COMMUNICATION & SERVER
Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specifications GR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
P & F Krone module with base frame in the recess / surface made out of 1.2 mm thick sheet steel box, front openable, having locking arrangements duly powder painted,including dressing, ferruling and punching of telephone cable with krone tool etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
10 Pairs
Supply & laying of RG-6 cable for TV in existing conduit/ raceway complete as required.
Supply & Installation of RJ-45 Information outlets Jack ABS FR grade with spring loaded collapsible shutters in jack recess suitable for Cat 6 application with terminator caps for tooless termination .
Single Outlet
Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors as per ANSI/TIA/EIA 568 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568, minimum requirement for 1G BASE-T/ 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, Minimum 750 to 1000 mating cycles in plug contacts for long durability complete in all respect. All as per pre approved by Engineer in charge.
1 Mtr/3 ft
SITC of 10/100 MBPS Unmanaged Switch
Supply , Installation, Testing and Comissioning of Rack mounted 19", Cat 6 UTP,1.5-1.6 MM CRS chasis , powder coated Modular Patch Panels with collapsible shutters on jacks to support latest ammendments of TIA / EIA Cat 6 Specifications in Existing Communication Rack along with necessary connections of Cat 6 UTP Cables, With Rear Cable management trays and clamps.
24 Ports Patch Panel
16 Ports Patch Panel
8 Ports Patch Panel
Supply, Drawing and Testing, of stranded Single mode (9/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1- 2, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect. All as per pre approved by Engineer in charge.
6Fiber
Supply, Drawing and Testing, of stranded Single mode (9/125 µm) glass optic fiber SFP Module as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1- 2,
Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Singlemode Pigtail (9/125 µm) made of glass fiber optic, should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc. with IEC 61754-20, as per latest ammendments of TIA/EIA 569 Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge.
Supply, Installation, & Testing of Indoor duplex Singlemode patch cord (9/125 µm made of glass fiber optic with LSZH jacket, Multimode G652.D Mounted on both sides with ST/E-2000/SC/LC/MT-RJ/PC type Duplex connectors in acc. with IEC 61754-20 as per latest ammendments of TIA/EIA 569B.3, as per requirements complete in all respect. All as per pre approved by Engineer in charge.
Ceiling Design Access Point 2.4G 450Mbps & 5.8G 1300Mbps Compliant with PoE 802.3 at Centralized management for WI-FI
Supply , Installation, Testing and Comissioning of Wall mounted Communication rack with glass doors, handles ,lock , Top and Bottom Cable entries, Supports for mounting rack on wall , Cable managers, one Fan, Equipment mounting hardware, power supply box for supplying power to switches, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable .
9U(44 mm ) wall mounted
CCTV NETWORK
Supply of 2 Megapixel Fixed Lens Camera IR Dome Type: 1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8mm Fixed lens, 0.028 Lux at F1.2, ICR, ONVIF, support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 128 GB (SD card not included), IP67, IK10, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, video tampering, UL, CE, FCC certified.
Supply of 2 Megapixel Fixed Lens Camera IR Bullet Type: 1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.01 Lux at F1.2, 0 Lux with IR, ICR, ONVIF (PROFILE S, PROFILE G), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 128 GB (SD card not included), IP67, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Video tampering, UL, CE, FCC certified.
Supply of NVR 32 Channel: Connect Up to 32 IP Cameras, Dual OS, Up to 8 Megapixels Resolution, HDMI output with 4k output and VGA output with 2MP Output , Support H.265,H.264, MJPEG, Incoming Bandwidth 256 Mbps, 4 SATA Hard Disks, ANR Technology, 4 SATA interfaces for 4 HDDs and capacity of each HDD upto 6TB, 2 USB at least 1 × USB with 3.0, Serial interface:1 RS-485, 1 RS-232, Alarm I/O 16/4, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified.
Supply of 16 Port Network Switch Gigabit POE: 16 × gigabit PoE ports, 1 × gigabit RJ45 port, and 1 × gigabit SFP fiber optical port, IEEE 802.3at/af standard
Supply of connector
Supply of Hard Disc 4 TB
Supply of high resolution led monitor 32" complete as required.
Installation, Testing and Comissioning Charges
Supply and laying of HDMI Cable
INTERNAL LIGHTING FIXTURES
Providing of IP20 LED batten type light fixture made from CRCA sheet steel housing suitable for moutning LED tube system (integral driver), Power Consumption of 18W / 36W 1500-3000 lumens, system lumen efficiency 80 lm/Watt output, life time of 50,000 burning hours with 70% initial lumen maintained. CCT 3000°K, 4000°K & 6000°K..
Providing of IP20 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Downlight with die-cast aluminum housing & Heat Sink for heat dissipation, high purity reflector with external driver having efficiency > 85% and in compliance to IEC standards. Power Consumption of ≤ 15W / 18W with ~ 1100 / 1250 lumens, System Lumen efficacy of 70 lm / watt output suitable to replace 1x18W / 2x18W / 2x 26W CFL Downlights, life time of 50000 Burning Hours with 70% of intial Lumen maintaned. CCT 3000°K , 4000°K & 6000°K. Fixture shall be CE compliance. Note:- fixture Wattages are
Provide of Aesthetically Designed linear LED mirror light with a high output PMMA Diffuser for glare free output including making connection testing etc. as required Dimension-300mm
Provide of energy efficient / energy saving direct fit (Retrofit) Inverter LED Bulb .
12 Watt LED LAMPS
Provide of Heavy duty capacitor start 900/1400 RPM single phase ISI marked Exhaust fan,IS:2312 marked in existing opening including making connections testing etc. as required. 300 mm Sweep 9 900 RPM)
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Provide & Fixing of capacitor start, wall mounting fan of following sweep with the help of anchor bolts including making connection testing etc. as required.
400 mm sweep( oscillating type)
DISTRIBUTION PANEL
Supply, Installation, Testing & Commissioning of LT Panel of cold rolled sheet metal construction, floor mounting, free standing, totally enclosed, dust and vermin proof conforming to IP42 degree of enclosure protection with base channel of min ISMC-75N channel. The panel shall be extendable from either side.The panel shall be single front type.Cable entry shall be from bottom.Final paint shade shall be RAL-7035.The panel shall have direct type fire suppression system. The sheet steel used for said construction shall have following thickness: a. Load bearing members : 2 mm b. Rest : 1.6 mm c. Gland plate : 3.0 mm
MAIN DISTRIBUTION PANEL
TERRACE FLOOR PANEL
FAÇADE LIGHTING
Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge.
Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge.
Single arm overhang
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.
42Watt LED Street Light fixture with Minimum lumen output 7500 lm
FIRE FIGHTING
(A)Supply installation testing & comisning of Electrical driven Terrace Pump Suitable for automatic opration & consisting of following. Complete in all respect as required. (B) Horizontal type multistage, centrifugal, split casing pump of cast iron body 7 bronze impeller with ss shaft mechanical confirming to is:1520. (C) Suitable HP Squirell cage induction motorTEFC type Suitable for opration on 415 V 3 phase 50 HZ AC supply with IP55 class of protection of enclosure, Horizontal foot mounted type with class F insulation confirming to is 325 (D) MS Fabricated comon base plate. coupling, coupling gaurd, foundation bolts etc as required. (E) Suitable cement concrete foundation duly plastered and with anti vibration pads.
900 lpm with 35 M Head
PIPES & ACCESSORIES
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
25 mm. Dia
32 mm. Dia
40 mm. Dia
50 mm. Dia
65 mm. Dia
80 mm. Dia
100 mm. Dia
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
Single headed Gunmetal
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed Gunmetal
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
100mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm
100mm dia
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Gun Metal
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket
30 Meter
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required.
Gun Metal
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required
2 way-100 mm dia M.S. Pipe
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Pendent Sprinkler
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing & fixing flow switch in following sizes M.S.pipe including connection etc as required.
100mm dia
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
Providing & fixing (1.0 M x .45 M x 0.6 M ) OUTDOOR HOSE CABINET suitable for accommodating hydrants made of not less than 16 swg. M. S. sheet having central opening glazed door including necessary locking arrangement, painting (one coat primer & two coats of paint ) and housing 2 Nos. RRL hose pipe, 1 No branch pipe.
Providing & fixing ( 0.9 M WIDE x 1.8 M HEIGHT ) INDOOR HOSE CABINET suitable for accomodating hydrants made of TUBULAR pipe having central opening glazed door including necessary locking arrangement, painting (one coat primer & two coats of paint) and housing 2 Nos. RRL hose pipe, 1 no branch pipe.
Providing and fixing with bracket/ supports etc wall/floor mounted fire extinguishers as per details below:
Carbon Dioxide type fire extinguisher with cylinder fully charge of 4.5
Providing and fixing charged ABC type fire extingusher including the
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
25 mm dia
S K Integrated Consultants
SATISH BUILDERS
M.C Construction Company
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
mscetendermay24.pdf
Tender Documents • 1.04 MB
NITHOSTEL.pdf
Additional Documents • 0.32 MB
BOQ_848763.xls
BOQ • 0.82 MB
Download all tender documents and submit your bid