Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC PLOT NO 3 DIVINE SCHOOL ROAD NEAR BJP KARYALAY PORBANDAR KHAMBHALIYA HIGHWAY BOKHIRA PORBANDAR 360 579 | PORBANDAR | GUJARAT | 360579 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹39.8 L+₹1.5 L (3.98%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹43.7 L+₹5.4 L (14.2%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹44.4 L+₹6.2 L (16.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹44.6 L+₹6.3 L (16.6%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹79,000
Closing Date
29 May 2023, 6:00 pmClosed
Shri Prahalad Meena, Offg Garrison Engineer
GE Navy Porbandar Tija Mile Porbandar
SPECIAL REPAIR TO WIRING AND CABLES AT WARD ROOM COMPLEX AT NAVAL BASE AND FWC AND SHOPPING COMPLEX AT NAUSENA BAGH UNDER GE NAVY PORBANDAR
2023_MES_593493_1
9173/PBR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹79,000
Yes
31 Aug 2024
5 May 2023
30 May 2023
5 May 2023
29 May 2023
22 May 2023
6 May 2023 - 19 May 2023
Amount
Taking down old point wiring complete for (light, fan, socket 5/15 amps, bell point etc) complete with all light fittings accessories, such as switches,sockets 5/15 Amps, ceiling roses, pendents, regulators, sockets etc removing materials for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer -In-Charge.
M & L for point wiring with PVC insulated unsheathed stranded copper conductor cable FRLSH of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm width/in concealed conduit non metallic , rigid PVC conduit of adequated size with all fittings and conduit accessories including suiitable size modular metal flush box and modular white cover plate with frame for housing the switches,socket outlets ,including all necessary wall cutting and making good disturbed surface complete all as specified and directed by Engineer -In-Charge. Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate.
(a) One light point controlled by one, one way switch
(b) One ceiling /exhaust fan point controlled by one switch and regulator
Ditto all as per Item No. 2.00 2 but wire 2.5 sqmm One 3 pin 5 amp socket out point on the independent board complete all as specified and directed by Engineer -In-Charge.
Ditto all as per Item No. 2.00 but wire 2.5 sqmm One3 pin 5 amps socket outlet point on same board with other switches complete all as specified and directed by Engineer -In-Charge.
Ditto all as per Item No. 2.00 above but for one socket outlet 15 amp on independent board with 4.0 Sqmm cable and 4.0 Sqmm earth wire complete all as specified and directed by Engineer -In-Charge.
S & F Modular switch 1 way 6A, 1 module complete all as specified and directed by Engineer -In-Charge.
S & F Ceiling rose surface bakelite 65x50 mm three terminal complete all as specified and directed by Engineer -In-Charge.
S & F modular socket, Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed by Engineer -In-Charge.
S & F Modular switch 1 way 16A, 1 module complete all as specified and directed by Engineer -In-Charge.
S & F modular socket 16A - 2/3 pin combined 2 module complete all as specified and directed by Engineer -In-Charge.
S & F Modular fan regulator 120 Watt, 2- module, AC 240 Volts complete all as specified and directed by Engineer -In-Charge.
Taking down fan of any make / type / sweep, sealing cable end, dismantling of blades and for repair / overhauling complete all as specified and directed by Engineer -In-Charge.
M &L for Overhauling of ceiling fan /wall fan of any make and sweep after opening and cleaning rotor bearing and stator properly and oiling / greasing of bearing / bushes, replacing fan capacitor including painting of fan, reassmbling the same, fixing and connecting on its existing position and testing on completion complete all as specified and directed by Engineer -In-Charge.
Fixing or hanging only ceiling fan after overhauling/repair of winding above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan (max up to 1m length) complete all as specified and directed by Engineer -In-Charge.
S & F in replacement LED tube light fittings 4 feet 1x22 Watt, 220V, AC Decorative ultra slim polycarbonate LED lighting fixture with high lumen output, environmental friendly, energy efficient including LED Tube light connecting up with 3 core flexible cppper conductor cable with sutable size from ceiling rose complete all as specified and directed by Engineer -In-Charge.
S & F in replacement LED tube light fittings 4 feet 1x36 Watt, 220V, Warm white AC Decorative ultra slim polycarbonate LED lighting fixture with high lumen output, environmental friendly, energy efficient including LED Tube light connecting up with flexible cppper conductor cable with sutable size from ceiling rose complete all as specified and directed by Engineer -In-Charge.
S & F in replacement LED tube light fittings mirror type with high output diffuser 2 feet, 1x10 Watt, 220V, AC decorative box type with driver,holder including LED Tube light connecting up with flexible coppper conductor cable with sutable size from ceiling rose complete all as specified and directed by Engineer -In-Charge.
S & F in replacement LED down light 1x15 Watt 220V, Slim, compact, aluminum die cast edge lit panel. recess mounted square fixture with opal diffuser and separate electronic driver connecting up with 3 core flexible copper conductor cable with sutable size from ceiling rose / junction complete all as specified and directed by Engineer -In-Charge.
S & F in replacement LED luminaire 595 mm x 595 mm 36 watt , 220 V AC Ultra modern Slim recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling (35mm height), including connecting up with 3 core flexible cppper conductor cable with suItable size complete all as specified and directed by Engineer -In-Charge. Havells Cat Part No:- VENUSNEO2X2PLR36WLED857STTR or its equivalent model of make specified in Appx 'B' here-in-before.
S & F in replacement earth enclosure with 2 pin earth plug sokcet complete with MCB SP 25 amp, flush mounting type complete all as specified and directed by Engineer -In-Charge.
S & F in replacement MCCB DB VERTCLE TYPE made of sheet steel, powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade, Glazed door 415 Volts TPN with 8 way Double door complete all as specified and directed by Engineer -In-Charge.
S & F in replacement MCB DB made of sheet steel, powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade, 415Volts TPN with 4 way Double door complete all as specified and directed by Engineer -In-Charge.
S & F in replacement MCB DB made of sheet steel, powder painted with NUTRAL bus bar 200 A, neutral link, earth bar and Din rail, 240Volts SPN with 4 way Double door, IP-43-IK09 protection complete all as specified and directed by Engineer -In-Charge.
S & F in replacement MCB DB made of sheet steel, powder painted with NUTRAL bus bar 200 A, neutral link, earth bar and Din rail, 240Volts SPN with 8 way Double door, IP-43-IK09 protection complete all as specified and directed by Engineer -In-Charge.
S & F in replacement MCB DB made of sheet steel, powder painted with NUTRAL bus bar 200 A, neutral link, earth bar and Din rail, 240Volts SPN with 12 way Double door, IP-43-IK09 protection grade complete all as specified and directed by Engineer -In-Charge. Note for item No. 21.00 to 25.00 :- (a) The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall / DB to be fixed on wall. (b) The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface. (c) Rate is inclusive of cutting chase S & F in replacementin repair lush to wall & making good to the disturbed surfaces of walls etc to match with existing surfaces including white washing/colour washing/distempering to match with existing wall/floor/ceiling finishes making good disturbed surfaces of walls, etc.
S & F in replacement MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 40 to 63 Amps complete all as specified and directed by Engineer -In-Charge.
S & F in replacement MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 25 to 63 Amps complete all as specified and directed by Engineer -In-Charge.
S & F in replacement MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 40 to 63 Amps complete all as specified and directed by Engineer -In-Charge.
S & F in replacement MCB SP 240 Volts 'C' series, breaking capacity 10 KA of rating 6-32 Amps complete all as specified and directed by Engineer -In-Charge.
S & F in replacement MCCB TPN 125 Amps, 415Volts, 16-18 KA complete all as specified and directed by Engineer -In-Charge.
M & L for Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00 mm dia by means of bolts, nuts, check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit, charcoal common salt, earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe, G.I. protection pipe 15 mm dia up to 7.5m long, PCC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, PCC pit cover including earth work complete all as shown in electrical plate No. 3 of SSR 2009 (part-I) complete all as specified and directed by Engineer -In-Charge.
S & F in replacement Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 4 Sqmm, earth continuity conductor of size 4.0 Sqmm to be drawn through and including PVC CASING CAPING/PVC Conduit not less then 25mm dia medium Grade fixed on walls/roof/floors complete all as specified and directed by Engineer -In-Charge. Note :- Two wires of 4 sqmm and one wire of 4.0 sqmm and one run of PVC casing caping/Conduit shall be measured as one unit.
S & F in replacement Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through and including PVC CASING CAPING/PVC Conduit not less then 32mm dia medium Grade fixed on walls/roof/floors complete all as specified and directed by Engineer -In-Charge. Note :- Two wires of 6 sqmm and one wire of 6.0 sqmm and one run of PVC casing caping/Conduit shall be measured as one unit.
S & F in replacement Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 4 Single core of size 10 Sqmm, earth continuity conductor of size 1X 10 Sqmm to be drawn through and including PVC casing caping/PVC Conduit not less then 32mm dia medium Grade complete all as specified and directed by Engineer -In-Charge. Note :- Four wires of 10 sqmm and one wire of 10 sqmm and one run of PVC conduit /casing caping shall be measured as one unit.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 10 sqmm 4 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 16 sqmm 4 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 25 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along polecomplete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 35 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 50 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 95 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 120 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed.
Supply, laying and jointing Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric underground power cable with stranded aluminium conductor cross sectional area 240 sqmm 3.5 core suitable for working on 1100 Volts, confirming to IS-1554 laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note for item No. 35.00 to 42.00 :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe shall be measured and paid for separately.
Excavation in trenches in hard /dense soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete all as specified and directed by Engineer-In-Charge.
Returning, filling in including spreading, leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays, struts have been erected and tested complete all as specified and directed by Engineer-In-Charge.
Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-In-Charge.
M & L for Double Walled Corrugated (DWC) HDPE pipe of size 50 mm outer dia and 38 mm inner dia conforming to IS 16205 Part - 24 Including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable fixed in repair / replacement complete all as directed by Engr-In-Charge.
M & L for Double Walled Corrugated (DWC) HDPE pipe of size 63 mm outer dia and 50 mm inner dia conforming to IS 16205 Part - 24 Including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable fixed in repair / replacement complete all as directed by Engr-In-Charge.
M & L for Double Walled Corrugated (DWC) HDPE pipe of size 90 mm outer dia and 75 mm inner dia conforming to IS 16205 Part -24 Including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable fixed in repair / replacement complete all as directed by Engr-In-Charge.
S& F in replacement of LED Bollard light inverted Pyramid Tripod Type LED Bollard with soft 360 degree distribution with neceesary mounting foundation and connecting with flxible copper cable of suitable size complete all as directed by Engr-In Charge. Make : CROMPTON / BAJAJ / WIPRO
Supply & fix PVC insulated 3 core 1.5 sqmm multistranded Copper conductor complete all as specified and directed by Engineer-In-Charge.
Taking down old u/s LT panel of any size/ make/ including all unserviceable parts removing from site complete all as specified and directed by Engineer-In-Charge.
Supply, install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 200 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 100X5 - 3 Nos (f) MCCB 160A TPN 25 kA with thermal magnetic release ( Legrand Cat No 420057) -01 Nos (g) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- MCCB 63A TP 16 kA with thermal magnetic release ( Legrand Cat No 4200 03) -02 Nos (b) All out going LT feeders name with radium stickers -02 Nos Note:- MCCB
Supply, install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 200 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 100X5 - 3 Nos (f) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- (a) Onload Manual Change Over Switch Open execution type (L &T Model No- CO21600OOOO)
Supply, install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
(A) Incoming:- (a) Copper bus bar TPN 200 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 100X5 - 3 Nos (f) MCCB 160A TPN 25 kA with thermal magnetic release ( Legrand Cat No 420057) -01 Nos (g) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- (a) MCCB 63A TP 16 kA with thermal magnetic release ( Legrand Cat No 4200 03) -02 Nos , (b) MCCB 40A TP 16 kA with thermal magnetic release ( Legrand Cat No 4200 02) -01 Nos (c) All out going LT feeders name with radium stickers -03 Nos Note:- MCCB Make:- Legrand/L&T(d-sine series) /Schenider (d) One Separate compartment will be provided for mounting 3 Phase Energy meter (Energy meter will be provided by department)
M&L Earthing with 600X600X6 mm thick , galvanised steel earth plate electrode buried vertically in ground (Earth pit not less than 2.25 meter deep below normal ground level ) with top edge of plate vertically at a depth ,not less than 1.5 m below ground level connected to and including GI strip of size 32X6 mm by means of bolts,nuts,check nuts, And washer of galvanised steel, Gi shrip to be provide upto the extent of 7.5 m GI strip to be duly connected to metalic bodies of HT/LT equipment with provision of mixture of charcoal dust & common salt packed all ground the earth plate upto MS funnel with wire mesh provided inside concrete earth pit for watering arrangement,complete all as shown on electrical plate no.3 of SSR Part I (2009) and testing on completion complete all as specified and directed by Engineer -In-Charge.
Material and labour point wiring with 1.5 sqmm (nominal cross section area) single core PVC insulated unsheathed cable of 1100 Volts grade (FRLS) multistrand with copper conductor drawn through and including non metallic, rigid PVC conduit of adequate size with all fittings and conduit accessories surface/concealed in wall/ceiling/floor/roof etc. including 1.6 mm thick sunk mild steel terminal box with 3mm thick plastic laminated sheet top cover,modular plate and top cover, cadmium plated iron screws for housing the switches, socket outlets including provision of 1.5 sqmm green in colour PVC insulated copper conductor single core multistrand (FRLS) for earth continuity conductor and connected to common earth duly all as specified for the following:-
(a) One light point control by one switch
(b) One ceiling fan/exhaust fan control by one switch
(c) One light point controlled by two 2 way switches.
(d) Switch socket same board outlet 3 pin 5 amps with 1.5 sq mm cable as earth continuity conductor.
(e) Switch board of independent 5 Amps socket.
Ditto all as per Item No. 56.00 above but wire 2.5 sq mm cable for switch socket outlet 3 pin 15 Amps with 2.5 sqmm as earth continuity conductor complete all as specified and directed by Engineer -In-Charge.
S & F modular switch 2 way 6A, 1 module including cover plate complete all as specified and directed by Engineer -In-Charge.
Supply and fixing modular fan regulator electronic stepped type with cover plate, AC 240 Volts complete all as specified and directed by Engineer -In-Charge.
Taking down old u/s exsiting ceiling/wall mounted/exhaust fan of any size and refixing the same after cleaniing, painting complete all as specified and directed by Engineer -In-Charge.
Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed by Engineer -In-Charge.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm complete all as specified and directed by Engineer -In-Charge.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed by Engineer -In-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer -In-Charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer -In-Charge.
Supply and fixing LED lights fitting 1x 16W, 220V,AC decorative box type with driver, holder including LED light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer -In-Charge.
Supply and fixing LED lights fitting 1x28 box type with driver, down light type ,holder including LED light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer -In-Charge.
Supply, Installation, Testing and commissioning LT Panel board suitable for working on 3 phase, 4 wire, 415 Volts, AC, 50 HZ,outdoor type , floor monted, free standing, dust and vermin proof, air ventilation with IP -54 protection fabricated out of 3.15 mm thick CRCA sheet powder coated painting, CPRI approved, separate compartment for MCCB /metering equipments/cable gallay etc, front and rear hinged door with locking arrangement, copper bus bar duly covered with heat shrinkable sleeves colour coaded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing calbes and connecting the outgoing MCCBs/switch gears with main bus bar by using copper bus links or copper conductor cable of suitable rating and connecting with terminal blocks of appropriate rating terminated by cabl lugs, thimbles etc, earthing terminals, affixing danger notice plate, control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement. Angle iron of size 50mm x 50mm x6mm for mounting of LT panel 40cm above floor level complete including necessary PCC foundation all as specified and directed by Engineer -in-Charge comprising of followings:-
(a) 300 Amps rated copper bus bar with colour coded heat shrinkable sleeve -01 Job (b) MCCB 200 Amps 415V 16 kA 4 pole - 1 No. (Main Incomer) (c) MCCB 160 Amp 415V TP 25kA- 3 No (KG school panal,FWC, Shopping). (d) MCCB 125 Amp 415V TP 25kA- 1 Nos (Spare) (e) MCCB 63 Amp 415V TP 25kA- 3 No (Street light,Family clinic, spare). (f) Ammeter,Digital type, with suitable CTs (g) Voltmeter,Digital type - 01 set (h) R-Y-B phase indicating lamp -01 set
Supply, Installation, Testing and commissioning LT Panel board suitable for working on 3 phase, 4 wire, 415 Volts, AC, 50 HZ,outdoor type , floor monted, free standing, dust and vermin proof, air ventilation with IP -54 protection fabricated out of 3.15 mm thick CRCA sheet powder coated painting, CPRI approved, separate compartment for MCCB /metering equipments/cable gallay etc, front and rear hinged door with locking arrangement, copper bus bar duly covered with heat shrinkable sleeves colour coaded fixed on DMC/SMC insulators bottom cable entry holes for incoming and outgoing calbes and connecting the outgoing MCCBs/switch gears with main bus bar by using copper bus links or copper conductor cable of suitable rating and connecting with terminal blocks of appropriate rating terminated by cabl lugs, thimbles etc, earthing terminals, affixing danger notice plate, control wiring with flexible copper conductor cables of suitable size and adequate length, control fuses/MCBs and PCC foundation as per site requirement. Angle iron of size 50mm x 50mm x6mm for mounting of LT panel 40cm above floor level complete including necessary PCC foundation all as specified and directed by Engineer -in-Charge comprising of followings:-
(a) 220 Amps rated copper bus bar with colour coded heat shrinkable sleeve -01 Job (b) MCCB 160 Amps 415V 16 kA 4 pole - 1 No. (Main Incomer) (c) MCCB 100 Amp 415V TP 25kA- 2No. (d) MCCB 63 Amp 415V TP 25kA- 3No. (e) Ammeter,Digital type, with suitable CTs (f) Voltmeter, Digital type - 01 set (g) R-Y-B phase indicating lamp -01 set
Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 Amps complete all as specified and directed by Engineer -In-Charge.
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer -In-Charge.
S & F cable route indicator made out of CI die cast 100mm round disc min 2 mm thick including excavation, earth work and embedding in PCC 1:2:4 type B-1 of size 200 x 200 x 200 mm, 2 feet in height complete all as specified and directed by Engineer -In-Charge.
BABUBHAI BHIMABHAI PANDAVADRA
JAY BHARAT METAL SUPPLIERS
SANVI ASSOCIATES
RAJ ENTERPRISE
SURESH ELECTRICALS
Leo Elevator Company
shree chamunda enterprise
SHREEJI ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .