Loading…
Loading…
Tender ID
Tender Value
₹17.6 L
EMD Value
₹35,118
Closing Date
13 Apr 2026, 4:00 pmClosed
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX RAJ BAGH
Maintenance of Electrical Works in DMFT Office Administrative Complex Pulwama Phase I First and second floor
2026_PWDJK_307384_1
NIT No.01//2026-27 Dt/04/04/2026
Open Tender
Electrical Works
Percentage
20 days
PULWAMA
Please refer Tender documents.
4 documents required · 4 mandatory
₹800
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹35,118
6 Apr 2026
6 Apr 2026
14 Apr 2026
6 Apr 2026
13 Apr 2026
6 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/ Anchor/equivalent as directed by engineer incharge.) single core cable in surface / recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit/ duct( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.), with modular switch ( Legrand Mylinc/Legrand Alzy /ABB Tivishi/schneider Zencelo /Crabtree athena/ Eq. make.), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. | 15 | Point | - | - |
| - | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/ Anchor/equivalent as directed by engineer incharge.) single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. | 20 | Point | - | - |
| - | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/ Anchor/equivalent as directed by engineer incharge.)single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. | 45 | Point | - | - |
| - | Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/Anchor make ) single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit ( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.) | 210 | Mtr | - | - |
| - | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Modular Switch & Socket:- ( Legrand Mylinc/Allzy /ABB Tivisha/schneider Zencelo /Crabtree athena make.) | 30 | Each | - | - |
| - | Wiring for 6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ paraflex/Anchor make) single core cable in surface/recessed (cutting the wall and making good the same in case of recessed conduit ) medium class PVC conduit ( Anchor/ Polycab /Ravindra/equivalent make as directed by engineer incharge.) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 550 | Mtr | - | - |
| - | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Legrand Mylinc/Legrand allzy /ABB Tivisha/schneider Zencelo /Crabtree athena make.) | 30 | No. | - | - |
| - | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. | 30 | No. | - | - |
| - | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. For AC's | 4 | Each | - | - |
| - | Supplying and fixing following modular switch/ socket ( Legrand Mylinc /ABB Tivisha/schneider Zencelo /Crabtree athena make.) with modular plate and cover including switch box and connections etc. as required. | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.10 MB
BOQ_997273.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .