Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BID | |
| 2 | L2₹58.4 L+₹3.4 L (6.28%)Rejected-Finance | L2 | Rejected-Finance SECOND LOWEST | |
| 3 | L3₹68.5 L+₹13.6 L (24.8%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L3 | Rejected-Finance THIRD LOWEST | |
| 4 | L4₹87.8 L+₹32.9 L (59.9%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L4 | Rejected-Finance FOURTH LOWEST |
Tender Value
Refer Docs
EMD Value
₹1.8 L
Closing Date
14 Jan 2021, 5:30 pmClosed
SE PWD CEC
Office of The Superintending Engineer Central Electrical Circle P.W.D. 184 C.R.Das Road Berhampore Murshidabad PIN-742101
Construction of Composite Court Building at Domkal Murshidabad----SITC of Air Conditioning arrangement.
2020_WBPWD_309486_1
WBPWD/CEC/NIT/09/Q/20-21
Open Tender
A/C ORG
Item Rate
45 days
DOMKOL
Please refer Tender documents.
4 documents required · 4 mandatory
₹1.8 L
on virtual platform
18 Mar 2021
17 Dec 2020
16 Jan 2021
17 Dec 2020
14 Jan 2021
24 Dec 2020
23 Dec 2020
Amount
Sub Head1: Ductable Air Conditioner Unit Supply and Delivery of Ceiling Suspended Ductable type Split Airconditioners having Microprocessor Based Control System and the following specification Capacity- 8.5 Tonnage (upto +1 TR acceptable) Rated cooling Capacity- 102000 BTU/Hr. No of IDU--1 No Air-flow/ IDU- 3400CFM No of ODU- 1 or 2 Nos Compressor-Twin Scroll Compressor Refrigerent- R410A Condenser and Cooling Coil: Copper Coil Power Supply : 415V, 50Hz, 3 Ph AC (with applicable tolarance)
Make- Carrier/ Voltas/ Blue Star/ Mitsubishi Electric/ Hitachi/ Trane/York/Daikin
Supply and Delivery of Ceiling Suspended Ductable type Split Airconditioners having Microprocessor Based Control System and the following specification Capacity- 11 Tonnage (upto +1 TR acceptable) Rated Cooling Capacity- 132000 BTU/Hr. No of IDU- 1 No Air-flow/IDU-4400 CFM No of ODU- 1 or 2 Nos Compressor- 2 Nos Scroll Compressor Refrigerent- R 410 A Condenser and Cooling Coil: Copper Coil Power Supply : 415V, 50Hz, 3 Ph AC (with applicable tolarance)
Make- Carrier/ Voltas/ Blue Star/ Mitsubishi Electric/ Hitachi/ Trane/York/Daikin
Installation Testing and Commissioning of Ductable Split AirConditioners by making scaffolding arrangement as per site condition, Supply of necessary Refrigerant, connecting Control and power cabling and other necessary materials to complete the job. 8.5 TR Ceiling Suspended Ductable Type Split AC
11 TR Ceiling Suspended Ductable Type Split AC
Sub Head 2 : Refrigerent Piping Supply and fixing of following sizes of refrigerent pipe made out of hard drawn copperincluding accessories, jointing/brazing etc duly insulated with Class-O nitrile tubular rubber sections to prevent condensation with suitable adjustable type hanger supports etc complete as required. 22.20 mm , 1.00 mm thick with 19mm thick insulation
15.90 mm , 1.00 mm thick with 19mm thick insulation
12.70 mm, 0.80mm thick with 19mm thick insulation
9.50 mm, 0.8 mm thick with 19mm thick insulation
Supply & Installation of 6mm Nitrile Rubber insulated PVC / HDPE pipes of following sizes with fitting, accessories, bends, elbows, tees, flanges, U-trap, wall sleeves, hangers, supports, anchors etc for draining condensate water from indoor unit to the nearest drain point. 25 mm.Dia
32 mm.Dia
40 mm.Dia
Sub- Head 3- Ducting Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal ( Make-Tata Steel/Sail/Jindal ) rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc as per approved drawings and specifications of following sheet complete as required 24G
Duct tharmal insulation by supplying and fixing of following thickness duly laminated aliminum foil of mat finish closed cell Nitrile rubber (Class 'O') insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per sepcification and as required a) 13mm
Supplying and fixing of acoustic insulation inside ducting with 10mm thick open cell nitrile rubber (class O) of density 140Kg/Cum-160 Kg/ Cum insulation with bolts nuts GI washers etc as required.
Supply and Fixing of underdeck insulation with 50mm thick TF quality Expanded polysterene slab complete with all accessories, required materials etc. [Make- Beardsell/Astha/Thermowell]
Supplying and fixing of Thermal insulation of the duct running in non AC with 75mm thick expanded polysterne finished with 12mm thick sand cement plaster. (Make- Beardsell/Astha/Thermowell)
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supply Installation testing and commissioning of Flexible Canvas Connection as per direction of the EIC.
Supplying fixing testing and commissioning of fresh air provision as per direction of the EIC incl. filter, damper, bird screen etc complete as required.
Sub Head 2:- Room Air Conditioner Hi- Wall split Supply and Delivery of Hi wall Split Air Conditioner having following specification Cooling Capacity (BTU/Hr)- 24000 BTU/Hr ISEER- As per 3 Star/2018-19 of BEE/BIS IS compliance - IS 1391 Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condensor Coil : Copper Operating, Condencer burst proof P2 type, Outdoor Temparature = 50°C
Power Supply - 230V,50Hz ( +Tolerrance as per applicable standard) The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrial rubber insulation - 3 mtr (ii) necessary copper cable (FRLS type - make :Finolex/RR Kable/Polycab/Havells/Gloster) - 3mtr [Make: Mitsubishi Electric / O-General / SHARP/Hitachi/Daikin]
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including Supply of required Refrigerant, S&F of necessary fixing arrangement for indoor and 40 x 40 x 5 mm MS angle iron frame for outdoor unit, duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of the EIC.
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of above AC machines. i) Supply and Fixing of extra refrigerand pipe with insulation foam insulation (as requisite dia)
ii) 3 core PVC insulated FRLS grade copper cable (make: Finolex/RR kable/Polycab/Havells/Gloster)
Supply and Fixing of PVC drain pipe (make approved by EIC)
Sub- Head 4--Misceleneous Items Supply, fabrication and fixing 3 nos M.S. u-channel of 6mm thick of size (100mm x 40mm x 40mm) of 1 mtr length for making platform for installation of outdoor unit of ductable packaged split AC incl. drilling 2 Nos. holes in each channel including cutting holes the wall & grouting the same with Cement concrete (1:11/2 :3) etc. fabricated with horizontal angle of 50mm x 50mm X 6mm 6mm of 2 Mtr length including supporting angle 50mm x 50mm x 6mm in each platform in outer edge for transmitting the load centrally through 2Nos.(50mm x 50mm x6mm) Angle inserted into the exiting wall. The platform should be baricated with verticle angle of 25mm x 25mm x 6mm of 1 mtr. length, abricated on the surface of each Horizontal channel & Angles & interconneed by 25mm x 25mm x 5mm MS patti. Area of platform is 3Mtr. x 1 Mtr.
Supply , laying and termination of 1.1 kv grade following size PVC insulated PVC sheathed unarmoured Copper Cable (Make- Finolex/RR Kable/Polycab/Havells/Gloster) 3C X 2.5 SqMM
4C X 2.5 SqMM
M.F suspended ceiling made with 12.5 mm thick Gypsum plaster board including GI perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27mm) along with perimeter of ceiling with GI intermediate channel of 0.9 mm thick size 45mm x 15mm placed at 750 mm c/c with GI ceiling angle of size 25mm x 10mm x 0.55mm thick fixedto the ceiling with GI Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50mm x 26mm fixed to the intermediate channels with the help of connecting clip and in the direction of perpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and finished with jointing compound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes, cost of accessories, fittings and fixtures, scaffolding and labour charges etc. complete)
Supply & installation of trap door for indoor unit covering and with made of fixing boiling water resistant ply 12 mm conforming to IS 303/1989 bonded with phenol formaldehyde synthetic resin of approved make and brand fitted and with hard wooden frame work of approve quality with necessary support angle iron , lock and key fixed as per design as per approval and direction of Engineer -in - charge.
Supply & Fixing of plenum chamber outer boxing made of Aluminium Composite Panel (ACP) with frame work of aluminium hollow section and other accessories including inside acoustic insulation with 10mm thick open cell nitrile rubber(class 0) of density 140Kg / Cum-160 Kg / Cum insulation.
Terms and condition The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Release of security will be as per PWD notification no.5784-PW/L&A/2M-175/2017 dated:12.09.2017
JASODA REFRIGERATOR SERVICING CENTRE
SKY DECORATIONS PRIVATE LIMITED
Lyric International
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .