EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Electrification of Wellness Health Centre Brariangan-A
2025_PWDJK_292057_1
NIT No.141/2025-26 Dt/14/10/2025
Open Tender
Electrical Works
Percentage
10 days
Brariangan
Please refer Tender documents.
4 documents required · 4 mandatory
₹200
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹2,000
14 Oct 2025
14 Oct 2025
31 Oct 2025
14 Oct 2025
30 Oct 2025
14 Oct 2025
Wiring for lighting points/fan points/ exhaust fan points/call bell points with 1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch , modular plate, etc. as required. (Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent make ) excl. cost of conduit.
Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, etc. as required. (Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or eq. ) excl. cost of conduit
Supplying and fixing of modular sockets/ indicators/switches on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent)
i.3 pin 5A - 10A socket.
ii. indicator.
iii.6 pin 15/16A socket.
iv. 15/16A switch.
v. 5A - 10A switch.
Point wiring for 5A -10A socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires in recessed or surface conduiting system,(Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent) excl. cost of conduit
Supply, installation, testing and commissioning of Angle / batten holders including cost of base block , 9 Watt LED bulb and necessary connections as required. (Havells/ Philips or eq. make).
Supply, installation, testing and commissioning of1200 mm sweep ceiling fans of Havells/ Crompton Greaves/Bajaj/ Anchor or eq. make to be approved by EIC, incl. cost of ceiling rose (if required) and making of necessary connections.
Supply and fixing of single module stepped type electronic type fan regulator on the existing modular plate switch box including connections, but excluding modular plate etc. as required. (ABB/Schneider/SSK/Anchor /Havells or eq. make to be approved by EIC)
Supply, installation, testing and commissioning of 200 mm sweep shutter type exhaust fans, incl. cost of ceiling rose and making of space in walls/ windows as per site and necessary connections. (Havells/ Philips/ Crompton/ Anchor or eq. make to be approved by EIC).
Supply and fixing of 25 mm dia./25 mm wide Medium grade PVC conduit including its allied accessories like bends and concealed deeps, etc. for laying of wires, recessed in RCC slab/walls incl. resurfacing of walls or fixed with clips and rowel plugs complete.
Supply and fixing of fan deep made of heavy gauge sheet in RCC slabs
Supply and fixing of 16 way , Double door surface/ recess mounting , Horizontal type, 240 V, SP&N MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excl. cost of MCBs and Incomer.
Supply, installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T or eq. make to be approved by EIC suitable for inductive load in the MCB distribution board complete with necessary connections.
Supply, installation, testing and commissioning of 32/40A double pole rating 240/415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T or eq. make to be approved by EICsuitable for inductive load in the MCB distribution board complete with necessary connections.
Supply, installation, testing and commissioning of 63A double pole rating 240/415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T or eq. make to be approved by EIC suitable for inductive load in the MCB distribution board complete with necessary connections.
Supply, laying, connecting and commissioning of 25 sq. mm 2 core PVC insulated and steel armored 1.1 KV grade Aluminum LT cable , incl. cost of required al. thimbles duly crimped. (Over head/ under ground).
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.93 MB
BOQ_941241.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .